find Keyword "三维重建" 100 results
  • ANATOMIC STUDY ON HOOK OF HAMATE BONE

    Objective To study the hook of hamate bone by anatomy and iconography methods in order to provide information for the cl inical treatment of injuries to the hook of hamate bone and the deep branch of ulnar nerve. Methods Fifty-two upper l imb specimens of adult corpses contributed voluntarily were collected, including 40 antisepticized old specimens and 12 fresh ones. The hook of hamate bone and its adjacent structure were observed. Twentyfour upper l imbs selected randomly from specimens of corpses and 24 upper l imbs from 12 healthy adults were investigated by computed tomography (CT) three-dimensional reconstruction, and then related data were measured. The measurement results of24 specimens were analyzed statistically. Results The hook of hamate bone is an important component of ulnar carpal canal and carpal canal, and the deep branch of ulnar nerve is located closely in the inner front of the hook of hamate bone. The flexor tendons of the forth and the l ittle fingers are in the innermost side, closely l ie next to the outside of the hook of hamate bone. The hamate bone located between the capitate bone and the three-cornered bone with wedge-shaped. The medial-, lateral-, and front-sides are all facies articularis. The hook of hamate bone has an approximate shape of a flat plate. The position migrated from the body of the hamate bone, the middle of the hook and the enlargement of the top of the hook were given the names of “the basis of the hook”, “the waist of the hook”, and “the coronal of the hook”, respectively. The short path of the basement are all longer than the short path of the waist. The long path of the top of the hook is the maximum length diameter of the hook of hamate bone, and is longer than the long path of the basement and the long path of the waist. The iconography shape and trait of the hook of hamate bone is similar to the anatomy result. There were no statistically significant differences (P gt; 0.05) between two methods in the seven parameters as follows: the long path of the basement of the hook, the short path of the basement of the hook, the long path of the waist of thehook, the short path of the waist of the hook, the long path of the top of the hook, the height of the hook, of hamate bone, and the distance between the top and the waist of the hook. Conclusion The hook of hamate bone can be divided into three parts: the coronal part, the waist part, and the basal part; fracture of the hamate bone can be divided into fracture of the body, fracture of the hook, and fracture of the body and the hook. Facture of the hook of hamate bone or fracture unnion can easily result in injure of the deep branch of ulnar nerve and the flexor tendons of the forth and the l ittle fingers. The measurement results of CT threedimensional reconstruction can be used as reference value directly in cl inical treatments.

    Release date:2016-08-31 05:47 Export PDF Favorites Scan
  • Using Spiral CT Three Dimensional Reconstruction in Chest Injury after Stereotactic Multiple Rib Fractures Treated by Internal Fixation with Small Incision

    目的探讨多发性肋骨骨折合理治疗方法。 方法回顾性分析山东省日照市岚山区人民医院心胸外科2010年1月至2013年10月115例胸部闭合性损伤患者的临床资料,其中男81例、女34例,年龄19~75岁,平均36.2岁。 结果CT三维重建能够准确判断肋骨骨折情况及胸廓变形情况,然后设置小切口选择性手术内固定肋骨骨折,患者经过手术治疗后全部痊愈,无死亡病例,患者术后疼痛明显减轻,胸廓形状基本恢复,呼吸功能及咳嗽功能基本恢复,住ICU时间8~72(10± 2)h,住院时间9~21(12± 1)d。随访6~18个月,随访率88.7%(102/115);患者对手术治疗效果满意度为95.1%(97/102)。 结论多发性肋骨骨折患者利用螺旋CT三维重建立体定位后采用小切口手术内固定治疗是一种安全且符合微创原则的治疗方法。

    Release date: Export PDF Favorites Scan
  • Proposal of a novel comprehensive classification for femoral intertrochanteric fractures

    Objective To introduce a novel comprehensive classification for femoral intertrochanteric fractures, and to accommodate the clinical requirement for the world-wide outbreak of geriatric hip fractures and surgical operations. Methods On the basis of reviewing the history of classification of femoral intertrochanteric fractures and analyzing the advantages and disadvantages of AO/Orthopaedic Trauma Association (AO/OTA) classification in different periods, combined with the current situation of extensive preoperative CT scan and three-dimensional reconstruction and widespread use of intramedullary nail fixation in China, the “Elderly Hip Fracture” Research Group of the Reparative and Reconstructive Surgery Committee of the Chinese Rehabilitation Medical Association proposed a novel comprehensive classification for femoral intertrochanteric fractures, focusing on the structure of fracture stability reconstruction during internal fixation. Results The novel comprehensive classification of femoral intertrochanteric fractures incorporates multiple indicators of fracture classification, including the orientation of the fracture line, the degree of fracture fragmentation, the lesser trochanteric bone fragment and its distal extension length (>2 cm), the posterior coronal bone fragment and its anterior extension width (involving the lateral cortex of the head and neck implant entry point), transverse fracture of the lateral and anterior wall and its relationship with the implant entry point in the head and neck, and whether the cortex of the anteromedial inferior corner can be directly reduced to contact, etc. The femoral intertrochanteric fractures are divided into 4 types (type A1 is simple two-part fractures, type A2 is characterized by lesser trochanter fragment and posterior coronal fractures, type A3 is reverse obliquity and transverse fractures, type A4 is medial comminution which lacks anteromedial cortex transmission of compression force), each of which is subdivided into 4 subtypes and further subdivide into finer subgroups. In a review of 550 trochanteric hip fracture cases by three-dimensional CT, type A1 accounted for 20.0%, type A2 for 62.5%, type A3 for 15.5%, and type A4 for 2.0%, respectively. For subtypes, A2.2 is with a “banana-like” posterior coronal fragment, A2.4 is with distal cortex extension >2 cm of the lesser trochanter and anterior cortical expansion of the posterior coronal fragment to the entry portal of head-neck implants, A3.4 is a primary pantrochanteric fracture, and A4.4 is a concomitant ipsilateral segmental fracture of the neck and trochanter region. ConclusionThe novel comprehensive classification of femoral intertrochanteric fractures can describe the morphological characteristics of fractures in more detail, include more rare and complex types, provide more personalized subtype selection, and adapt to the clinical needs of both fractures and surgeries.

    Release date:2022-09-30 09:59 Export PDF Favorites Scan
  • Application value of three-dimensional reconstruction for localization of pulmonary nodules in thoracoscopic lung wedge resection: A retrospective cohort study

    ObjectiveTo evaluate the safety and application value of three-dimensional reconstruction for localization of pulmonary nodules in thoracoscopic lung wedge resection.MethodsThe clinical data of 96 patients undergoing thoracoscopic lung wedge resection in our hospital from January 2019 to August 2020 were retrospectively reviewed and analyzed, including 30 males and 66 females with an average age of 57.62±12.13 years. The patients were divided into two groups, including a three-dimensional reconstruction guided group (n=45) and a CT guided Hook-wire group (n=51). The perioperative data of the two groups were compared.ResultsAll operations were performed successfully. There was no statistically significant difference between the two groups in the failure rate of localization (4.44% vs. 5.88%, P=0.633), operation time [15 (12, 19) min vs. 15 (13, 17) min, P=0.956], blood loss [16 (10, 20) mL vs. 15 (10, 19) mL, P=0.348], chest tube placement time [2 (2, 2) d vs. 2 (2, 2) d, P=0.841], resection margin width [2 (2, 2) cm vs. 2 (2, 2) cm, P=0.272] or TNM stage (P=0.158). The complications of CT guided Hook-wire group included pneumothorax in 2 patients, hemothorax in 2 patients and dislodgement in 4 patients. There was no complication related to puncture localization in the three-dimensional reconstruction guided group.ConclusionBased on three-dimensional reconstruction, the pulmonary nodule is accurately located. The complication rate is low, and it has good clinical application value.

    Release date:2021-10-28 04:13 Export PDF Favorites Scan
  • Three-dimensional reconstruction of carp brain tissue and brain electrodes for biological control

    In order to accurately implant the brain electrodes of carp robot for positioning and navigation, the three-dimensional model of brain structure and brain electrodes is to be proposed in the study. In this study, the tungsten electrodes were implanted into the cerebellum of a carp with the aid of brain stereotaxic instrument. The brain motor areas were found and their three-dimensional coordinate values were obtained by the aquatic electricity stimulation experiments and the underwater control experiments. The carp brain and the brain electrodes were imaged by 3.0 T magnetic resonance imaging instrument, and the three-dimensional reconstruction of carp brain and brain electrodes was carried out by the 3D-DOCTOR software and the Mimics software. The results showed that the brain motor areas and their coordinate values were accurate. The relative spatial position relationships between brain electrodes and brain tissue, brain tissue and skull surface could be observed by the three-dimensional reconstruction map of brain tissue and brain electrodes which reconstructed the three-dimensional structure of brain. The anatomical position of the three-dimensional reconstructed brain tissue in magnetic resonance image and the relationship between brain tissue and skull surface could be observed through the three-dimensional reconstruction comprehensive display map of brain tissue. The three-dimensional reconstruction model in this study can provide a navigation tool for brain electrodes implantation.

    Release date:2020-12-14 05:08 Export PDF Favorites Scan
  • Three-dimensional reconstruction of femur based on Laplace operator and statistical shape model

    Reconstructing three-dimensional (3D) models from two-dimensional (2D) images is necessary for preoperative planning and the customization of joint prostheses. However, the traditional statistical modeling reconstruction shows a low accuracy due to limited 3D characteristics and information loss. In this study, we proposed a new method to reconstruct the 3D models of femoral images by combining a statistical shape model with Laplacian surface deformation, which greatly improved the accuracy of the reconstruction. In this method, a Laplace operator was introduced to represent the 3D model derived from the statistical shape model. By coordinate transformations in the Laplacian system, novel skeletal features were established and the model was accurately aligned with its 2D image. Finally, 50 femoral models were utilized to verify the effectiveness of this method. The results indicated that the precision of the method was improved by 16.8%–25.9% compared with the traditional statistical shape model reconstruction. Therefore, the method we proposed allows a more accurate 3D bone reconstruction, which facilitates the development of personalized prosthesis design, precise positioning, and quick biomechanical analysis.

    Release date:2023-12-21 03:53 Export PDF Favorites Scan
  • Design of visualized medical images network and web platform based on MeVisLab

    With the trend of the development of "Internet +", some further requirements for the mobility of medical images have been required in the medical field. In view of this demand, this paper presents a web-based visual medical imaging platform. First, the feasibility of medical imaging is analyzed and technical points. CT (Computed Tomography) or MRI (Magnetic Resonance Imaging) images are reconstructed three-dimensionally by MeVisLab and packaged as X3D (Extensible 3D Graphics) files shown in the present paper. Then, the B/S (Browser/Server) system specially designed for 3D image is designed by using the HTML 5 and WebGL rendering engine library, and the X3D image file is parsed and rendered by the system. The results of this study showed that the platform was suitable for multiple operating systems to realize the platform-crossing and mobilization of medical image data. The development of medical imaging platform is also pointed out in this paper. It notes that web application technology will not only promote the sharing of medical image data, but also facilitate image-based medical remote consultations and distance learning.

    Release date:2017-04-13 10:03 Export PDF Favorites Scan
  • 先天性心脏病合并气管性支气管伴支气管狭窄一例

    Release date:2020-01-17 05:18 Export PDF Favorites Scan
  • Multi-Slice Spiral CT Angiography of Liver with Three-Dimensional Reconstruction Technique and Its Clinical Applications

    Release date:2016-09-08 11:52 Export PDF Favorites Scan
  • Study on Peribiliary Vascular Plexus of Hepatic Portal Bile Duct in Rats

    【Abstract】Objective To investigate the anatomic structure and experimental methods of peribiliary vascular plexus(PVP) in rat’s hepatic portal bile duct.Methods To observe the morphological structure of PVP in rat’s hepatic portal bile duct after the hepatic artery was perfused with Chinese ink and transparency management, performed and to make three dimensional reconstruction of PVP’s spacial structure in MoticBuaa3Dvol software.Results The microvascular distribution and plane structure of PVP in rat’s hepatic portal bile duct could be shown clearly through Chinese ink perfusion and transparency management. The three dimensional structure of PVP could be reconstructed effectively by MoticBuaa3Dvol software, its effect was verisimilitude. Conclusion Chinese ink perfusion and vitrification is a simple and easy method in PVP’s morphologic study of rat’s hepatic portal bile duct. MoticBuaa3Dvol software is useful in microvascular study of hepatic portal bile duct.

    Release date:2016-09-08 11:54 Export PDF Favorites Scan
10 pages Previous 1 2 3 ... 10 Next