ObjectiveTo summarize the indication and surgical experiences of valve replacement, high-risk factors and long-term results for aortic regurgitation and large left ventricle. MethodsWe retrospectively analyzed the clinical data of 42 patients with aortic regurgitation and left ventricle end-diastolic diameter (LVEDD) ≥70 mm and left ventricle end-systolic diameter (LVESD) ≥ 50 mm in our hospital from March 2004 through December 2012. There were 38 males and 4 females,aged 16-73 (45.86±14.99) years. The patients underwent aortic valve replacement, who were evaluated by echocardiography at pre-operation, pre-discharge and early follow-up. The follow up period was 12-132 months. ResultsEarly death occurred in one patient. And five patients died during the follow-up. One week after surgery in 41 patients, LVEDD (62.00±13.21 mm), LVESD (50.71±14.02 mm), indexed LVEDD (35.23±8.58 mm/m2), indexed LVESD (28.92±9.08 mm/m2), LVEF (46.41%±12.49%), were significantly smaller than those before the operation (P<0.01). Heart function grades, preoperative EF, LVEDD and indexed LVEDD were the predictors for left ventricular function recovery. One-year, 5-year, 10-year survival rate was 92.9%, 90.2%, 83.8%, respectively. ConclusionMost of patients with aortic regurgitation and large left ventricle still have indications for surgical treatment, but severe left ventricular dysfunction and ventricular arrhythmia are high risk factors for long-term survival.
ObjectiveTo investigate effectiveness and safety of transcatheter aortic valve replacement in the treatment of aortic regurgitation. Methods PubMed, EMbase, The Cochrane Library, Web of Science, CNKI, Wanfang Data and VIP were searched from inception to August 2021. According to the criteria of inclusion and exclusion, two reviewers independently screened the literature, extracted the data and evaluated the quality of the included studies. Then, Stata 16.0 software was used for meta-analysis. Subgroup meta-analysis of valve type used and study type was performed. ResultsTwenty-five studies (12 cohort studies and 13 single-arm studies) were included with 4 370 patients. Meta-analysis results showed that an incidence of device success was 87% (95%CI 0.81-0.92). The success rate of the new generation valve subgroup was 93% (95%CI 0.89-0.96), and the early generation valve subgroup was 66% (95%CI 0.56-0.75). In addition, the 30-day all-cause mortality was 7% (95%CI 0.05-0.10), the 30-day cardiac mortality was 4% (95%CI 0.01-0.07), the incidence of pacemaker implantation was 10% (95%CI 0.08-0.13), and the incidence of conversion to thoracotomy was 2% (95%CI 0.01-0.04). The incidence of moderate or higher paravalvular aortic regurgitation was 6% (95%CI 0.03-0.09). Conclusion Transcatheter aortic valve replacement for aortic regurgitation is safe and yields good results, but some limitations can not be overcome. Therefore, multicenter randomized controlled trials are needed to confirm our results.
ObjectiveTo assess clinical results of aortic cusps replacement with bovine pericardium for bicuspid aortic valve (BAV) and severe aortic regurgitation (AR). MethodsClinical data of 79 patients with BAV and severe AR who underwent aortic cusps replacement with bovine pericardium in Wuhan Asia Heart Hospital from June 2008 to December 2013 were retrospectively analyzed. There were 60 male and 19 female patients with their age of 38±14 years (ranged 12-78 years). All the patients were in NYHA class Ⅱ. There were 26 patients with ascending aorta and sinotubular expanding. ResultsNo early death or major complication was recorded. Intraoperative transesophageal echocardiography showed successful repair with normal coaptation of the aortic leaflets in all the patients. AR grade was less than mild in all the patients with peak aortic valve pressure gradients of 14.2±2.8 mm Hg. All the patients were discharged from the hospital within 15 postoperative days without any adverse symptom, and were followed up for 50±16 months (ranged 9-64 months). During follow-up, all the patients were in NYHA classⅠ. There were 57 patients without AR, 16 patients with mild AR, 5 patients with moderate AR and 1 patients with severe AR. The peak of aortic valve pressure gradient was 12.4±3.2 mm Hg. The average diameter of ascending aorta was 2.7 cm in the patients with ascending aorta and sinotubular expanding. The shape of sinotubular kept normal. The height of coaptation of aortic valve was 0.58 cm by echocadiography. None of the patients died or required reoperation. The structural valve degeneration was not observed during the follow-up. ConclusionThree aortic cusps replacement with bovine pericardium can produce good hemodynamics and midterm results for patients with BAV and severe AR. The ascending aorta and sinotubular should be reduced and fixed in the patients with ascending aorta and sinotubular expanding.
ObjectiveTo summarize and analyze the risk factors and management of artificial valve slippage in transcatheter aortic valve implantation (TAVI).MethodsWe retrospectively analyzed the clinical data of 131 patients undergoing TAVI surgery in our center from September 2017 to May 2019, including 62 patients through transapical approach and 69 patients through transfemoral artery approach.ResultsA total of 131 patients received TAVI surgery, among whom 4 patients had slipped during the operation, 2 patients via transfemoral artery approach, and another 2 patients via transapical. The average age was 77±9 years with one female (25%). Preoperative evaluation, higher position and poor coaxial were main risk factors for valve slip in TAVI.ConclusionValve slippage is also a serious complication in TAVI surgery. Reasonable and effective treatment can avoid thoracotomy.
ObjectiveTo investigate the feasibility and safety of transcatheter aortic valve replacement (TAVR) through apical approach for aortic regurgitation of large annulus.MethodsFrom November 2019 to May 2020, 10 male patients aged 64.50±4.20 years with aortic valve insufficiency (AI) underwent TAVR in the Department of Cardiovascular Surgery, Xijing Hospital. The surgical instruments were 29# J-valveTM modified and the patients underwent TAVR under angiography. The preoperative and postoperative cardiac function, valve regurgitation, complications and left ventricular remodeling were summarized by ultrasound and CT before and after TAVR.ResultsA total of 10 valves were implanted in 10 patients. Among them, 1 patient was transferred to the aortic arch during the operation and was transferred to surgical aortic valve replacement; the other 9 patients were successfully implanted with J-valve, with 6 patients of cardiac function (NYHA) class Ⅱ, 4 patients of grade Ⅲ. And there was a significant difference between preoperation and postoperation in left ventricular ejection fraction (44.70%±8.78% vs. 39.80%±8.48%, P<0.05) or aortic regurgitation (1.75±0.72 mL vs. 16.51±8.71 mL, P<0.05). After 3 months, the patients' cardiac function was good.ConclusionTAVR is safe and effective in the treatment of severe valvular disease with AI using J-valve.
Objective To analyze the early prognosis of repairing adult aortic insufficiency with the Florida sleeve procedure. Methods The patients with aortic insufficiency who underwent Florida sleeve repair in the Nanjing First Hospital, Nanjing Medical University between August 2020 and May 2024 were selected. Their general data, perioperative conditions, and echocardiographic data before, during, and after the procedure and at follow-up were analyzed. Results Fifteen patients were included, consisting of 12 males and 3 females, aged 33-71 (53.5±12.4) years. Preoperative echocardiography indicated that there was 1 patient of rheumatic disease, 7 patients of degenerative disease, 4 patients secondary to aortic aneurysm, and 3 patients of bicuspid aortic valve. The severity distribution included 2 patients of severe insufficiency, 4 patients of moderate-to-severe insufficiency, 5 patients of moderate insufficiency, and 4 patients of mild-to-moderate insufficiency. The mean cardiopulmonary bypass time was (135.0±40.0) minutes, the aortic cross-clamp time was (109.9±38.6) minutes, and the median ICU stay was 1.0 day. No mortality was recorded within 30 days postoperatively. Follow-up echocardiography showed that the valve regurgitation, left ventricular end-diastolic diameter, left ventricular end-systolic diameter, and sinus diameter all achieved the desired outcomes. Conclusion Florida sleeve repair for aortic valve in patients with a sinus diameter less than 50 mm not only effectively improves hemodynamics in adults with aortic insufficiency, but also has the advantages of low surgical risk and rapid postoperative recovery, making it a promising procedure for clinical application.
Objective To investigate the left ventricular reverse remodeling (LVRR) in patients with aortic valve insufficiency with reduced ejection fraction (AIrEF) and aortic valve insufficiency with preserved ejection fraction (AIpEF) after transcatheter aortic valve replacement (TAVR). MethodsThe clinical and follow-up data of patients who underwent TAVR in the Department of Cardiothoracic Surgery, Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from 2018 to 2021 were retrospectively analyzed. According to the guideline, the patients with left ventricular ejection fraction<55% were allocated to an AIrEF group, and the patients with left ventricular ejection fraction≥55% were allocated to an AIpEF group. ResultsA total of 50 patients were enrolled. There were 19 patients in the AIrEF group, including 15 males and 4 females with a mean age of 74.5±7.1 years. There were 31 patients in the AIpEF group, including 19 males and 12 females with a mean age of 72.0±4.8 years. All patients underwent TAVR successfully. Echocardiographic results showed that TAVR significantly promoted LVRR in the patients. Significant LVRR occurred in the early postoperative period (the first day after the surgery) in both groups. It remained relatively stable after the LVRR in the early postoperative period (the first day after surgery) in the AIpEF patients, while it continued to occur in the early postoperative period (the first day after surgery) to three months after the surgery in the AIrEF patients, and then remained relatively stable. Compared to preoperative values, AIrEF patients had a reduction in the average left ventricular end-diastolic volume index and left ventricular end-systolic volume index by 16.8 mL/m2 (P=0.003) and 8.6 mL/m2 (P=0.005), respectively, and the average left ventricular end-diastolic diameter index and end-systolic diameter index decreased by 2.5 mm/m2 (P=0.003) and 1.9 mm/m2 (P=0.003), respectively on the first day after the surgery. In comparison to the first day after the surgery, AIrEF patients experienced an average increase of 12.1% in the left ventricular ejection fraction three months after the surgery (P<0.001). ConclusionTAVR has achieved good therapeutic effects in patients with aortic valve insufficiency, significantly promoting the LVRR in patients, and has better curative effects in AIrEF patients.