west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "主动脉瓣反流" 32 results
  • The clinical effect of a combined technical system for bicuspid aortic valves repair

    ObjectiveTo summarize the clinical result of a combined technical system for bicuspid aortic valve (BAV) repair. MethodsPatients who diagnosed as BAV and sever aortic regurgitation (AR) underwent a strategy of combined repair technics including annuloplasty, sinus plasty, leaflet plasty, sinus-tubular junction (STJ) plasty depending on anatomy pathological characteristics between October 2019 and January 2021 were enrolled. The clinical data of the patients were analyzed.ResultsA total of 17 patients were enrolled. There were 11 males and 6 females with an average age of 18-49 (32.4±13.6) years. Fifteen patients had typeⅠand 2 patients had typeⅡBAV according to Sievers classification. Annuloplasty was applicated in 13 patients, sinus plasty in 8 patients, leaflet plasty in 17 patients, and STJ plasty in 11 patients, respectively. The cardiopulmonary bypass (CPB) time was 95 (84, 135) min, aortic cross-clamping time was 68 (57, 112) min, and the ICU stay time was 17 (12, 25) h. After the operation, mild AR was presented in 14 patients, moderate AR in 1 patient and severe AR in 2 patients. The latter 3 patients underwent second operation under CPB, after then, 1 patient had mild AR and 2 patients had moderate AR. The follow-up time was 13.1±4.6 months. At the latest follow-up, 12 patients had mild AR and 5 patients had moderate AR, and no patient had reoperation. ConclusionA combined technical system for BAV repair can be used effectively and safely with an acceptable short and middle-term result.

    Release date:2023-07-10 04:06 Export PDF Favorites Scan
  • Longterm Followup of Left Ventricular Function and Aortic Valve Regurgitation after Rapid Twostage Arterial Switch Operation

    Abstract: Objective To investigate the longterm complications and preventions of rapid twostage arterial switch operation through longterm follow-up. Methods We reviewed the clinical information of 21 patients of rapid twostage arterial switch operation from September 2002 to September 2007 in Shanghai Children’s Medical Center. Among them, there were 13 males and 8 females with an average age of 75 d (29-250 d) and an average weight of 5 kg (3.5-7.0 kg). The data of left ventricle training period and the data before and after the twostage arterial switch operation were analyzed, and the risk factors influencing the aortic valve regurgitation were analyzed by the logistic multivariable regression analysis. Results The late diameter of anastomosis of pulmonary and aortic artery were increased compared with those shortly after operation (0.96±0.30 cm vs. 0.81±0.28 cm, t=-1.183,P=0.262; 1.06±0.25 cm vs. 0.09±0.21 cm, t=-1.833,P=0.094), but there was no significant difference. The late velocity of blood flow across the anastomoses was not accelerated, which indicated no obstruction. The late heart function was better than that shortly after operation, while there was no significant difference between left ventricular ejection fraction(LVEF) during these two periods (62.88%±7.28% vs. 67.92%±7.83%,t=1.362,P=0.202). The late left ventricular end diastolic dimension(LVDd) was significantly different from that shortly after operation (2.16±0.30 cm vs.2.92±0.60 cm,t=-5.281,P=0.003). Compared with earlier period after operation, the thickness of left ventricular posterior wall thickness(LVPWT)was also increased (0.39±0.12 cm vs. 0.36±0.10 cm,t=0.700,P=0.500), but there was no significant difference. The postoperative aortic valve regurgitation was worsened in 4 patients (30.77%, 4/13), not changed in 7 patients and alleviated in 2 patients compared with that before operation. There was no severe regurgitations during the followup. The logistic regression analysis showed that the small preoperative diameter ratio of aortic valve to pulmonary valve and long follow-up time were two risk factors for the [CM(159mm]aggravation of aortic regurgitation. Conclusion There is a relatively high aortic regurgitation rate after rapid two stage arterial switch operation, but there is no later death or reoperation and the survival conditions are satisfactory. All patients must be followed up periodically to check the anastomosis of pulmonary and aortic arteries and the aortic valve.

    Release date:2016-08-30 06:03 Export PDF Favorites Scan
  • Advances in transcatheter aortic valve replacement for pure aortic regurgitation

    Transcatheter aortic valve replacement (TAVR) for aortic stenosis has been confirmed to be safe and efficient, and its status has gradually increased with the continuous updating of guidelines. But for severe pure aortic valve regurgitation, it has long been considered a relative contraindication to TAVR. However, many elderly, high-risk patients with pure aortic regurgitation have also been treated with TAVR and prognosis was improved through off-label use of transcatheter heart valves due to contraindications to surgery or intolerance. But because of the complexity and challenging anatomic features, high technical requirements, limited device success rate, high rate of complications, and lack of randomized controlled studies to confirm its safety and efficacy, TAVR treatment of pure aortic regurgitation has been evolving in a debate. In recent years, with the application of new-generation valves and an increasing number of studies, some new insights have been gained regarding TAVR for severe aortic regurgitation, and this article will review the progress of research on TAVR for severe pure aortic regurgitation.

    Release date:2022-05-23 10:52 Export PDF Favorites Scan
  • Midterm outcomes of valve-sparing aortic root replacement in patients with aortic root aneurysm and moderate to severe aortic regurgitation

    ObjectiveTo evaluate the midterm effect of valve-sparing aortic root replacement (VSRR) on aortic root aneurysm and moderate to severe aortic regurgitation (AR). MethodsThe clinical data of patients with aortic root aneurysm and moderate to severe AR undergoing VSRR and surviving from the operation from October 2013 to May 2020 were retrospectively analyzed. There were 31 males and 9 females, with an average age of 47.1±13.4 years. There were 30 patients with true aneurysm of aortic root and 10 patients with dissecting aneurysm of aortic root. There were 3 patients with bicuspid aortic valve, and 12 patients with Marfan syndrome. The AR measured by the echocardiogram was moderate in 18 patients and severe in 22 patients. The average diameter of aortic annulus was 27.0±3.9 mm, and the mean largest diameter of aortic sinus was 52.3±6.1 mm. ResultsA total of 32 patients underwent David technique and 8 patients underwent Yacoub technique, and 10 patients underwent aortic cusp repair simultaneously. All 40 patients completed the follow-up, and the follow-up period was 12-86 (45.7±18.9) months. During the period, 1 patient died of heart failure, 2 had reoperation due to new-onset Stanford B aortic dissection, and no patients had reoperation related to aortic valve. The postoperative New York Heart Association cardiac function classification (1.6±0.5 vs. 2.8±0.8), left ventricular end-diastolic dimension (52.2±7.8 mm vs. 61.4±10.6 mm) and left ventricular end-diastolic volume (136.0±58.8 mL vs. 193.3±83.9 mL) of the patients were significantly improved compared with preoperative ones (P<0.05). By echocardiography, 19 patients had no AR, 18 patients had mild AR, 3 patients had mild-moderate AR, and no patients had moderate or higher AR. ConclusionIn patients with aortic root aneurysm and moderate to severe AR, VSRR technique avoids prosthetic valves and anticoagulation-related complications, has lower rate of AR recurrence and reoperation, and improves the quality of life in the midterm period.

    Release date:2022-08-25 08:52 Export PDF Favorites Scan
  • Advances in transcatheter aortic valve replacement for pure native aortic regurgitation

    Transcatheter aortic valve replacement (TAVR) has been confirmed to be safety and efficacy for high-risk elderly aortic stenosis, and the clinical effect of TAVR for medium and low-risk aortic stenosis is not worse than that of surgery. The development of surgical techniques and instruments has made cardiologists attempt to broaden the surgical indications. Many elderly and high-risk patients with pure native aortic regurgitation have been treated “off label” with similar techniques, completing artificial valve replacement, restoring valve function and improving the prognosis. However, due to the high requirements of surgical techniques and surgical complications, there is a lack of randomized controlled studies to confirm its safety and effectiveness. Unlike aortic stenosis, native aortic regurgitation presents unique challenges for transcatheter valves. In this article, the authors review current advances in the treatment of aortic valve regurgitation with TAVR.

    Release date:2019-12-13 03:50 Export PDF Favorites Scan
  • 单纯主动脉瓣反流合并左心室血栓行经导管主动脉瓣置换术一例

    Release date:2025-04-27 01:50 Export PDF Favorites Scan
  • Mid-to-long term fate of neo-aortic root after arterial switch operation for Taussig-Bing anomaly: A retrospective study in a single center

    ObjectiveTo explore growth pattern of neo-aortic root as well as development of neo-aortic regurgitation after arterial switch operation (ASO) for Taussig-Bing anomaly. MethodsFrom 2002 to 2017, the patients who received ASO, and were discharged alive from Shanghai Children’s Medical Center and followed up for more than 3 years were retrospectively involved in this study. ResultsA total of 127 patients were enrolled. There were 98 (77.2%) males, the median age at ASO was 73.0 d and the average weight was 4.7 kg. Forty-five (35.4%) children were complicated with mild or mild-to-moderate pulmonary insufficiency (PI) before ASO. The average follow-up time was 7.0 years. During the follow-up, 14 (11.0%) children presented moderate or greater neo-aortic regurgitation (neo-AR). The diameter of neo-aortic annulus and sinus of Valsalva was beyond normal range during the entire follow-up. The average diameter of neo-aortic annulus was 18.0 mm at 5 years and 20.5 mm at 10 years. The average diameter of sinus of Valsalva was 25.9 mm at 5 years and 31.1 mm at 10 years. Neo-AR continued to develop over time. The diameter of children who developed moderate or greater neo-AR was constantly larger than that of children who did not (χ2=18.3, P<0.001). Preoperative mild or mild-to-moderate PI was an independent risk factor for the development of moderate or greater neo-AR during mid-to-long term follow-up (c-HR=3.46, P=0.03). ConclusionThe diameters of neo-aortic annulus and sinus of Valsalva of Taussig-Bing children who receive ASO repair continue to expand without normalization. The dilation of annulus correlates with the development of neo-AR. PI before ASO repair increases the risk of neo-AR development.

    Release date:2024-04-28 03:40 Export PDF Favorites Scan
  • Clinical feasibility of transfemoral transcatheter aortic valve replacement in the treatment of high-risk pure aortic valve regurgitation

    Objective To assess early clinical safety and efficacy of transfemoral transcatheter aortic valve replacement (TF-TAVR) for pure aortic regurgitation (PAR). Methods The clinical data of PAR patients who underwent TAVR in Wuhan Asia Heart Hospital and Wuhan Asia General Hospital from January 2018 to October 2022 were retrospectively analyzed. Patients were divided into a TF-TAVR group and a transapical transcatheter aortic valve replacement (TA-TAVR) group. The clinical data of the patients were analyzed. Results A total of 54 patients were enrolled, including 34 males and 20 females with an average age of 74.43±6.87 years. The preoperative N-terminal pro-B-type natriuretic peptide level was lower [808.50 (143.50, 2 937.00) pg/mL vs. 2 245.00 (486.30, 7 177.50) pg/mL, P=0.015], and the left ventricular end-diastolic diameter (56.00±6.92 mm vs. 63.07±10.23 mm, P=0.005) and sinus junction diameter (32.47±4.41 mm vs. 37.65±8.08 mm, P=0.007) were smaller in the TF-TAVR group. There was no death in the two groups during the hospitalization. Only 1 new death within postoperative 1 month in the TF-TAVR group (cerebral hemorrhage). A total of 2 new deaths in the TF-TAVR group (1 patient of sudden cardiac death and 1 of multiple organ failure), and there was no death in the TA-TAVR group within postoperative 3 months. There was 1 new death in the TA-TAVR group (details unknown), and there was no death in the TF-TAVR group within postoperative 6 months. There was no statistical difference between the two groups in the all-cause mortality and the cumulative survival rate during the follow-up period (P>0.05). The incidence of high atrioventricular block was 36.0% in the TF-TAVR group and 10.3% in the TA-TAVR group (P=0.024). There were no significant differences between the two groups in the perivalvular leakage (≥moderate), valve in valve, a second valve implantation, valve migration, cerebrovascular events, major vascular complications, complete left bundle branch block, new permanent pacemaker implantation or transferring to surgery (P>0.05). However, the incidence rates of complete left bundle branch block and new permanent pacemaker implantation were higher in the TF-TAVR group, accounting for 56.0% and 40.0%, respectively. Conclusion TF-TAVR is a safe and feasible treatment for PAR patients, which is comparable to TA-TAVR in the early postoperative safety and efficacy.

    Release date:2024-08-02 10:43 Export PDF Favorites Scan
  • Application of Ozaki operation in treatment of aortic regurgitation in children

    ObjectiveTo explore the early results of Ozaki operation in children with aortic regurgitation.MethodsWe retrospectively analyzed the clinical data of 15 patients with aortic regurgitation who received the Ozaki operation in our hospital from April 2017 to July 2019. There were 11 males and 4 females with an average operation age of 10.7±3.7 years. Besides preoperative evaluation, aortic regurgitation and cardiac function were evaluated on 1 day, 1 week, 1 month, 3 months, and 6-12 months after surgery.ResultsIn 14 (93.3%) patients , the aortic valve leaflets functioned well on 1 day, 1 month, 3 months, and 6-12 months, and the regurgitation grade was Ⅰ-Ⅱ, which was improved than before (P=0.001). The cardiac function of children recovered quickly after operation. There was no statistical difference in ejection fraction on 1 day, 1 month, 3 months, and 6-12 months after operation (P>0.05). No children died, and no other clinical event was found.ConclusionThe Ozaki technique of reconstructing a tricuspid aortic valve leaflet for the treatment of severe aortic regurgitation in children is effective in short term, and the persistence of its valve function remains to be determined in the long-term follow-up.

    Release date:2020-12-07 01:26 Export PDF Favorites Scan
  • Expert recommendations for standardized perioperative management after transapical transcatheter aortic valve implantation

    The technique of transcatheter aortic valve implantation has become increasingly mature. Although the transapical approach has a certain degree of minimally invasive trauma, it still has the characteristics such as heart beating without cardiopulmonary bypass, and the low technical requirements of catheter guide wire. In particular, the valve path is short and coaxial, which is easy to manipulate, and pure regurgitation and stenosis can be easily operated and are not subject to the limit of peripheral artery stenosis. It is still one of China's main approaches for transcatheter aortic valve replacement. Its perioperative management still has specific features and differs from the femoral artery approach. In addition, there is little relevant literature abroad. Therefore, domestic experts in this field were organized to discuss the development of perioperative management specifications to provide reference and techniques support for developing this field in China and further improve the quality of clinical operation and perioperative management. It will provide more safe and more effective medical services to these patients.

    Release date:2023-07-10 04:06 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content