This paper discusses a female patient with severe aortic stenosis, who was preoperatively assessed to be at high risk of left coronary artery occlusion, but developed complete occlusion of the right coronary artery during the procedure of transcatheter aortic valve replacement, leading to hemodynamic disorder. Surgical treatment under emergency cardiopulmonary bypass played a critical role in rescuing the patient.
目的观察微创体外循环(minimal extracorporeal circulation,MECC)对主动脉瓣置换术临床效果的影响。 方法回顾性分析我院2010年3月至2012年10月共25例应用MECC方法行单纯主动脉瓣置换术(AVR)的临床资料,其中男15例、女10例,年龄40(19~58)岁。 结果总体外循环时间67(51~89)min、主动脉阻断时间42(33~63)min、转流中最低血红蛋白(Hb)9.6(8.3~12.6)g/dl、流转后Hb 9.5(7.7~12.6)g/dl,体外循环中无1例患者因Hb低而输入红细胞。所有患者均顺利拔除胸腔引流管,顺利出院,无院内死亡。 结论MECC系统应用于主动脉瓣置换安全可行,比传统心肺旁路系统具有更好的生物相容性和良好的临床结果,值得推广。
ObjectiveTo systematically review the predictive factors of new-onset conduction abnormalities(NOCAs) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) patients. MethodsThe CNKI, VIP, WanFang Data, PubMed, Cochrane Library and EMbase databases were electronically searched to collect the relevant studies on NOCAs after TAVR in patients with BAV from inception to December 5, 2022. Two researchers independently screened the literature, extracted data, and assessed the risk of bias of the included studies. Meta-analysis was then performed by using RevMan 5.4 software. ResultsSix studies involving 758 patients with BAV were included. The results of the meta-analysis showed that age (MD=−1.48, 95%CI −2.73 to −0.23, P=0.02), chronic kidney disease (OR=0.14, 95%CI 0.06 to 0.34, P<0.01), preoperative left bundle branch block (LBBB) (OR=2.84, 95%CI 1.11 to 7.23, P=0.03), membranous septum length (MSL) (MD=0.93, 95%CI 0.05 to 1.80, P=0.04), implantation depth (ID) (MD=−2.06, 95%CI −2.96 to −1.16, P<0.01), the difference between MSL and ID (MD=3.05, 95%CI 1.92 to 4.18, P<0.01), and ID>MSL (OR=0.27, 95%CI 0.15 to 0.49, P<0.01) could be used as predictors of NOCAs. ConclusionCurrent evidence shows that age, chronic kidney disease, LBBB, MS, ID, the difference between MSL and ID, and ID>MSL could be used as predictors of NOCAs. Due to the limited quantity and quality of included studies, more high-quality studies are required to verify the above conclusion.
Commissural misalignment of biological valve and autologous valve during transcatheter aortic valve replacement may affect the filling of coronary artery, reduce the feasibility of redo-aortic valve intervention and damage the valve function, which will adversely affect long-term prognosis of patients. Some studies have obtained achievement by changing the axial direction of valve and using individualized computer simulation technology to improve the alignment technology. However, there are still many unknown problems about the impact of commissural misalignment on patients, and accurate commissural alignment techniques still need to be further explored. This article systematically expounds the possible impact of commissural misalignment between biological valve and autologous valve in transcatheter aortic valve replacement, possibly effective accurate commissural alignment techniques and related research progress.
Biological valves can lead to structural valve degeneration (SVD) over time and due to various factors, reducing their durability. SVD patients need to undergo valve replacement surgery again, while traditional open chest surgery can cause significant trauma and patients often give up treatment due to intolerance. Research has shown that as an alternative treatment option for reoperation of thoracic valve replacement surgery, redo-transcatheter aortic valve replacement for SVD is safe and effective, but still faces many challenges, including prosthesis-patient mismatch, high cross valve pressure difference, and coronary obstruction. This article aims to review the strategies, clinical research status and progress of redo-transcatheter aortic valve replacement in SVD patients.
Transcatheter aortic valve replacement has revolutionized the management of aortic stenosis and become the gold standard for the treatment of symptomatic and severe aortic valve stenosis in elderly patients. With the improvement in design and materials, newer generation transcatheter aortic valve prostheses had overcome the limitations of early-generation devices that were susceptible to paravalvular leak, atrioventricular block and vascular complications, to a certain extent. This review provides an update on the latest advances in transcatheter aortic valve prostheses.
ObjectiveTo systematically review the efficacy and safety of transfemoral transcatheter aortic valve replacement (TFTAVR) under local anesthesia (LA) and general anesthesia (GA). MethodsElectronic databases including PubMed, EMbase, The Cochrane Library, Web of Science, CNKI, WanFang and CBM were searched to collect randomized controlled trial and cohort studies on clinical outcomes of TFTAVR under LA and GA from inception to September 2020. Two authors independently screened literature, extracted data and assessed the quality of studies, and a meta-analysis was performed by using Stata 16.0 software. ResultsA total of 30 studies involving 52 087 patients were included in this study. There were 18 719 patients in the LA group and 33 368 patients in the GA group. The results of meta-analysis showed that the in-hospital all-cause mortality rate [RR=0.65, 95%CI (0.45, 0.94), P=0.021], 30-day all-cause mortality rate [RR=0.73, 95%CI (0.62, 0.86), P<0.001], 30-day stroke [RR=0.82, 95%CI (0.68, 0.98), P=0.025], cardiac arrest [RR=0.50, 95%CI (0.34, 0.73), P<0.001], ICU stay time [RR=−6.86, 95%CI (−12.31, −1.42), P=0.013], and total hospital stay time [RR=−2.02, 95%CI (−2.59, −1.45), P<0.001] in the LA group were all better than those in the GA group. There was no significant difference in the in-hospital stroke [RR=0.83, 95%CI (0.69, 1.00), P=0.053], in-hospital myocardial infarction (MI) [RR=1.74, 95%CI (0.43, 7.00), P=0.434], or 30-day MI [RR=0.77, 95%CI (0.42, 1.42), P=0.404] between the two groups. ConclusionLA provides a safe and effective way to induce sedation without intubation, and may be a good alternative to GA for TFTAVR.
An elderly female patient, with systemic multiple organ dysfunction, suffered from severe aortic valve stenosis, was to undergo transcatheter aortic valve replacement (TAVR). She was intolerance of the computed tomography examination before surgery. Bedside echocardiography was employed to evaluate the patient’s aortic valve stenosis, valve anatomy and type, the condition of aortic root, the distance from coronary to aortic root, and lower-extremity vascular access. Finally, the emergent TAVR was successfully performed under general anesthesia, and the aortic valve trans-prosthetic gradient met a remarkable decrease after surgery.
ObjectiveTo analyze the factors influencing the occurrence of subclinical leaflet thrombosis (SLT) after percutaneous aortic valve replacement using balloon-expandable valve (Sapien3, S3). Methods Retrospective analysis was made on 62 patients with severe aortic stenosis undergoing percutaneous aortic valve replacement using S3 in our center from September 2020 to June 2022. Patients with a history of vascular atherosclerosis or with significant increase or insignificant decrease of aortic valve flow or gradient pressure during follow-up were selected for CT examination. Results A total of 26 patients were finally included, with an average age of 70.31±8.90 years, and the male proportion was higher (n=15, 57.69%). Among them, 5 patients had SLT. Compared with the non-SLT group, patients in the SLT group were older (68.52±8.80 years vs. 77.80±4.66 years, P=0.007). The age factor (≥75 years) and the diameter of the ascending aorta were associated with SLT (both P<0.05). Conclusion The incidence of SLT is higher in the elderly patients. It is speculated that SLT is related to the characteristics of short balloon dilation valves and low blood flow dynamics of valve racks.