west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "主动脉瓣置换" 197 results
  • Advantages and related developments of self-expandable valves for transcatheter aortic valve replacement

    Transcatheter aortic valve replacement is an effective treatment for aortic stenosis currently, especially in elderly, surgical high-risk, and surgical procedures-intolerant patients with severe aortic stenosis. After several generations of updates in design and function, the self-expandable valves have shown significant efficacy in treating aortic stenosis patients with bicuspid aortic valve, bioprosthetic valve failure or small annulus, and superiority in terms of valve durability, and the favorable hemodynamic outcomes could translate into clinical endpoint benefit. This literature review summarizes the advantages and recent advances of the self-expandable valves in transcatheter aortic valve replacement.

    Release date:2023-12-25 11:45 Export PDF Favorites Scan
  • Progress in the care of complications after transcatheter aortic valve replacement

    In recent years, heart valve disease has been increasing year by year. Transcatheter aortic valve replacement (TAVR) has become the first-line surgical method for patients with severe aortic stenosis due to the advantages of small surgical trauma and rapid postoperative recovery. In the context of the rapid development of TAVR, the postoperative complications of TAVR seriously affect the surgical success rate and patient prognosis. Therefore, the prevention and nursing of complications after TAVR are particularly important. This article will review the assessment, prevention and care of the complications such as arrhythmia, vascular complications, perivalvular leakage, stroke, and acute renal failure after TAVR in combination with the current situation at home and abroad, in order to enhance the clinical medical workers’ understanding of the complications.

    Release date:2023-06-21 09:43 Export PDF Favorites Scan
  • A case of transcatheter aortic valve replacement with right-&-left coronary protection

    Transcatheter aortic valve replacement (TAVR) has become a common theraputic option for aortic stenosis, but the evidence for precise anatomy for TAVR is accumulating. This paper presents the case of an 71-year-old female patient who had an extremely high risk of coronary obstruction due to both coronary ostia lying too low. The patient underwent TAVR with the help of coronary protection successfully. During the procedure, the patient was protected with wires only for both coronaries. After deployment, angiofluoroscopy suggested that chimney stenting should be applied for left coronary. The whole procedure was unenventful and both coronaries were seen.

    Release date:2022-05-24 03:47 Export PDF Favorites Scan
  • Advances in transcatheter aortic valve replacement for pure aortic regurgitation

    Transcatheter aortic valve replacement (TAVR) for aortic stenosis has been confirmed to be safe and efficient, and its status has gradually increased with the continuous updating of guidelines. But for severe pure aortic valve regurgitation, it has long been considered a relative contraindication to TAVR. However, many elderly, high-risk patients with pure aortic regurgitation have also been treated with TAVR and prognosis was improved through off-label use of transcatheter heart valves due to contraindications to surgery or intolerance. But because of the complexity and challenging anatomic features, high technical requirements, limited device success rate, high rate of complications, and lack of randomized controlled studies to confirm its safety and efficacy, TAVR treatment of pure aortic regurgitation has been evolving in a debate. In recent years, with the application of new-generation valves and an increasing number of studies, some new insights have been gained regarding TAVR for severe aortic regurgitation, and this article will review the progress of research on TAVR for severe pure aortic regurgitation.

    Release date:2022-05-23 10:52 Export PDF Favorites Scan
  • Cardiovascular collapse caused by balloon pre-dilation during transcatheter aortic valve replacement: a case report

    Circulatory collapse is a common complication of transcatheter aortic valve replacement (TAVR), mainly due to new severe aortic regurgitation after balloon pre-dilation. This article reports the case of an 80-year-old female patient with severe aortic stenosis, who had a type 1 bicuspid aortic valve, with calcified aortic valve commissure between the right and left coronary cusps. During the procedure of TAVR, severe aortic regurgitation was caused by pre-dilation with 20 mm and 23 mm balloons. Then circulatory collapse and cardiogenic shock occurred. After the emergency deployment of the Venus A L26 valve, the cardiovascular hemodynamics was immediately improved. This case suggests that oversized balloon dilation should be avoided to prevent circulatory collapse caused by massive aortic regurgitation.

    Release date:2022-05-24 03:47 Export PDF Favorites Scan
  • Effectiveness and safety of transcatheter aortic valve replacement in treatment of aortic regurgitation: A systematic review and meta-analysis

    ObjectiveTo investigate effectiveness and safety of transcatheter aortic valve replacement in the treatment of aortic regurgitation. Methods PubMed, EMbase, The Cochrane Library, Web of Science, CNKI, Wanfang Data and VIP were searched from inception to August 2021. According to the criteria of inclusion and exclusion, two reviewers independently screened the literature, extracted the data and evaluated the quality of the included studies. Then, Stata 16.0 software was used for meta-analysis. Subgroup meta-analysis of valve type used and study type was performed. ResultsTwenty-five studies (12 cohort studies and 13 single-arm studies) were included with 4 370 patients. Meta-analysis results showed that an incidence of device success was 87% (95%CI 0.81-0.92). The success rate of the new generation valve subgroup was 93% (95%CI 0.89-0.96), and the early generation valve subgroup was 66% (95%CI 0.56-0.75). In addition, the 30-day all-cause mortality was 7% (95%CI 0.05-0.10), the 30-day cardiac mortality was 4% (95%CI 0.01-0.07), the incidence of pacemaker implantation was 10% (95%CI 0.08-0.13), and the incidence of conversion to thoracotomy was 2% (95%CI 0.01-0.04). The incidence of moderate or higher paravalvular aortic regurgitation was 6% (95%CI 0.03-0.09). Conclusion Transcatheter aortic valve replacement for aortic regurgitation is safe and yields good results, but some limitations can not be overcome. Therefore, multicenter randomized controlled trials are needed to confirm our results.

    Release date:2023-03-01 04:15 Export PDF Favorites Scan
  • Application of Minimal Extracorporeal Circulation in the Aortic Valve Replacement

    目的观察微创体外循环(minimal extracorporeal circulation,MECC)对主动脉瓣置换术临床效果的影响。 方法回顾性分析我院2010年3月至2012年10月共25例应用MECC方法行单纯主动脉瓣置换术(AVR)的临床资料,其中男15例、女10例,年龄40(19~58)岁。 结果总体外循环时间67(51~89)min、主动脉阻断时间42(33~63)min、转流中最低血红蛋白(Hb)9.6(8.3~12.6)g/dl、流转后Hb 9.5(7.7~12.6)g/dl,体外循环中无1例患者因Hb低而输入红细胞。所有患者均顺利拔除胸腔引流管,顺利出院,无院内死亡。 结论MECC系统应用于主动脉瓣置换安全可行,比传统心肺旁路系统具有更好的生物相容性和良好的临床结果,值得推广。

    Release date: Export PDF Favorites Scan
  • Clinical efficacy of transcatheter aortic valve replacement in elderly patients with aortic stenosis: A systematic review and meta-analysis

    ObjectiveTo compare the complications of transcatheter aortic valve replacement (TAVR) between aortic valve stenosis (AS) patients ≥90 years and patients <90 years, and to explore the efficacy and safety of TAVR in AS patients ≥90 years.MethodsDatabases including PubMed, The Cochrane Library, EMbase, Medline, CNKI, Wanfang Data and China Biology Medicine disc (CBMdisc) were searched by computer from inception to May 2019. Two reviewers independently screened the literature, extracted the data and evaluated the quality of the included studies. RevMan 5.3 and Stata 15.0 were used for meta-analysis.ResultsA total of 12 cohort studies were included, including60 186 patients (11 350 patients ≥90 years and 48 836 patients <90 years). Meta-analysis showed that compared with the patients <90 years, those ≥90 years had higher all-cause mortality in the hospital (OR=1.51, 95%CI 1.37 to 1.66, P<0.000 01),on postoperative 30 d (OR=1.68, 95%CI 1.50 to 1.89, P<0.000 01) and at postoperative 1 year (OR=1.36, 95%CI 1.25 to 1.48, P<0.000 01), and had higher incidence of stroke (OR=1.31, 95%CI 1.18 to 1.46, P<0.000 01), bleeding events (OR=1.14, 95%CI 1.07 to 1.20, P<0.000 01) and vascular complications (OR=1.31, 95%CI 1.18 to 1.46, P<0.000 01). ConclusionAll-cause mortality and the incidence of some complications after TAVR in AS patients ≥90 years are higher than those in patients <90 years, but this difference is clinically acceptable. Therefore, TAVR treatment is safe and effective for elderly patients.

    Release date:2020-12-31 03:27 Export PDF Favorites Scan
  • Safety and effectiveness of the SAPIEN 3 transcatheter heart valve in the treatment of severe aortic stenosis: Early clinical outcomes of a multicenter study in China

    Objective To evaluate the safety and efficacy of transcatheter aortic valve replacement (TAVR) using the SAPIEN 3 system. MethodsThis was a prospective, multicenter, single arm study in 4 centers in China. The clinical data of 50 patients with high-risk symptomatic severe aortic stenosis who underwent TAVR using the SAPIEN 3 system from June 2017 to June 2019 were analyzed, including 27 males and 23 females aged 76.8±6.1 years. ResultsThe Society of Thoracic Surgeon score was 6.0%±2.8%. Totally, 20.0% of patients had severe bicuspid aortic stenosis. The operation time was 41.8±16.5 min and the hospital stay time was 8.5±5.0 d. At the postoperative 30-day follow-up, no all-cause mortality occurred and the device success rate was 89.5%. Major vascular complications occurred in one (2.0%) patient, stroke in one (2.0%) patient, new pacemaker implantation in one (2.0%) patient, as well as coronary artery obstruction in one (2.0%) patient. There was no moderate or moderate/severe paravalvular leak. The aortic pressure gradient was decreased from 49.2±16.2 mm Hg before the operation to 12.4±4.6 mm Hg at the postoperative 30-day follow-up, and the valvular area was increased from 0.6±0.3 cm2 to 1.3±0.3 cm2 (P<0.01). Moreover, the New York Heart Association classification in 83.7% of the patients was improved during the follow-up. ConclusionThis pre-marketing multicenter study has demonstrated the safety and effectiveness of transfemoral TAVR with the SAPIEN 3 transcatheter valve system in Chinese aortic stenosis patients at high risk for surgery.

    Release date:2022-05-23 10:52 Export PDF Favorites Scan
  • Investigation and analysis of operations, intraoperative instruments and nursing status of transcatheter aortic valve replacement in China

    ObjectiveTo investigate the operation of transcatheter aortic valve replacement (TAVR), the use of TAVR instruments and the current situation of TAVR-related nursing in our country, to reveal the characteristics of TAVR in various hospitals in our country, and to provide reference data for improving perioperative nursing and industry development of TAVR. MethodsA questionnaire survey was conducted among the head nurses of the cardiac catheterization laboratories of 51 hospitals in China that carried out TAVR operations, with a total of 5 items and 23 questions. The current situation of TAVR operation methods, intraoperative instruments and nursing care in China were analyzed. ResultsThe number of hospitals in China which started conducting TAVR and the beginning year were: 2 in 2010, 1 in 2012, 1 in 2013, 1 in 2015, 11 in 2016, 13 in 2017, 15 in 2018 and 7 in 2019; the number of transfemoral TAVR in 2019: 32 (62.75%) hospitals conducted on less than 20 patients, 7 (13.73%) hospitals 20-<50 patients, 6 (11.76%) hospitals 50-100 patients and 6 (11.76%) hospitals more than 100 patients; TAVR strategies adopted by most hospitals were: general anesthesia (90.20%), the use of vascular sealers (80.39%), backing by cardiac surgeon (74.51%) and using homemade prosthetic valves. Conclusion At present, the number of TAVR carried out in Chinese hospitals is still far behind that of developed countries in Europe and the United States. Our country has adopted the form of multidisciplinary cardiac team cooperation and formed a TAVR nursing model with Chinese characteristics.

    Release date:2022-02-15 02:09 Export PDF Favorites Scan
20 pages Previous 1 2 3 ... 20 Next

Format

Content