west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "人工关节" 47 results
  • ARTIFICAL JOINT REPLACEMENT FOR FUNCTIONAL RECONSTRUCTION OF PATIENTS FOLLOWING SEGMEN TAL RESECTION OF BONE TUMOR

    From 1972 to 1990,121 cases of bone tumor were treated by segmental resection of tumor and followed by artifical joint re- placement. All of the prostheses were designed and manufactured by our hospital. One hundred and two cases were followed up for an average of 7.4 years and the curative rate with the affected limbs preserved was 85.28%. The indication, the advantages and disadvantages, the material and the type of artifical joints, and the assessment of functional reconstruction following operation were discussed.

    Release date:2016-09-01 11:34 Export PDF Favorites Scan
  • Application of shared decision-making in the extended care of artificial joint replacement

    Objective To evaluate the effectiveness of the shared decision-making scheme in postoperative out-of-hospital extended care for patients with total hip/knee arthroplasty (THA/TKA). Methods Patients who underwent THA/TKA in the Department of Orthopedic Surgery at West China Hospital of Sichuan University between October 2023 and April 2024 were included using convenience sampling. Patients were divided into the control group (odd-numbered dates) and the intervention group (even-numbered dates) based on the surgical dates. The intervention group was received care guided by a shared decision-making protocol, whereas the control group was followed the standard post-arthroplasty follow-up procedures. Differences between the two groups were compared in terms of decision-making capacity, decision satisfaction, and hip/knee function at the following time points: on the day of discharge, 3 weeks after discharge, 2 months after discharge, and 3 months after discharge. Results A total of 118 patients were included, with 59 cases in each group. There were no significant differences in demographic and clinical characteristics between the two groups (P>0.05). In terms of decision-making, compared with the control group, the experimental group had stronger decision-making ability, lower decision-making conflict, and more satisfaction with the decision-making process (P<0.05). In terms of joint function, the experimental group showed better joint function than the control group at 3 weeks, 2 months, and 3 months after surgery (P<0.05). There was no significant difference in the pain dimension of the Western Ontario and McMaster Universities Osteoarthritis index between the two groups (P=0.199). Conclusions Compared with the traditional follow-up protocol, the shared decision-making protocol can enhance patient engagement in medical decision-making, reduce decisional conflict, improve satisfaction with the decision-making process, and simultaneously promote joint functional recovery and expedite the rehabilitation process.

    Release date:2025-09-26 04:04 Export PDF Favorites Scan
  • PHOTOELASTIC STUDY OF FRACTURE OF PROSTHETIC STEM AFTER FEMORAL HEAD REPLACEMENT

    Abstract The fracture of the prosthetic stem after prosthetic replacement of femoral head is not rare. In this study, the photoeastic instrument was used to study the stress distribution on the prosthetic stem following its insertion and to analyse the factors influencing the fracture of the stem. Through the examination of 9 places in 8 cases, it was found that:(1) The removal of femoral calcar and the inframedullary filling of the bone cement directly influenced the stress distribution. (2) The valgus or varus condition of the prosthesis would lead to stress concentration on the stem. (3) Once lossening of the prosthesis occured it would change the preliminary installingstress distribution in the upper femur which would lead to fatigue fracture. Ths experimental data and clinical observation would provide scientific basis forthe prevention of fracture of prosthetic stem following prosthetic replacement of femoral head.

    Release date:2016-09-01 11:10 Export PDF Favorites Scan
  • CURATIVE EFFECT OF PRESERVATION OF FEMORAL NECK IN TOTAL HIP ARTHROPLASTY

    Objective To discuss the clinical application of preserving femoral neck in total hip arthroplasty and to analyze the early stage results.Methods From January 1999 to June 2001, 12 patients underwent total hip arthroplasty with preservation of femoral neck. We cut off the femoral head in infra-head position with improved Moore micro-incisions to reserve intact neck of femur. Thensuitable size of extra cup was selected and placed at 55° eversion angle. The internal cup, made from ultra high polymer poly thene and with ultra radius design, was placed at 45°eversion angle. Harris scores were recorded before operation, after operation and during the follow-up. During the follow-up, the X-rayfilms were taken to assess position, loosening of the prosthesis and ectopic ossification.Results All 12 patients were followed up 2-4.5years with an average of 3.1 years. The mean Harris score of hip elevated from 54 scores before operation to 92 scores of the last follow-up. Mild ectopic ossification occurred in 3 cases. There was no prosthesis loosening and femoral prosthesis setting, and only onepatient had mild bone absorption around femoral prosthesis.Conclusion Total hip arthroplasty with femoral neck preservation is a good option for the patients who need total hip arthroplasty for variable reasons, which is indicated for the patients whose femoral neck is intact with no osteoporosis.

    Release date:2016-09-01 09:33 Export PDF Favorites Scan
  • MECHANISMS, PREVENTION, AND TREATMENTS OF PROSTHETIC ASEPTIC LOOSENING

    Objective To introduce the occurrence mechanisms, prevention, and treatment measures of prosthetic aseptic loosening. Methods The recent original articles about prosthetic aseptic loosening were extensively reviewed and analyzed. Results Prosthetic aseptic loosening was a very complex process involving many mechanical and biological aspects. The main mechanical factors included prosthetic materials, shapes and sizes, implant fixation methods (including surfacetreatments), cl inical installation, interface micromotion, stress shielding, implant wear, interface integrity, and peri prosthetic high hydraulic pressure, etc.; the main biological factors included the types and sizes of wear particles, cell-activated responses, cytokine release, enzyme activation and allergic reactions to wear particles, etc.. Many measures should be adopted to effectively prevent and treat it, including improving materials and designs of prostheses, fixation techniques, surgical techniques, and drug treatments. Conclusion Prosthetic aseptic loosening is still a troublesome compl ication after joint replacements in orthopaedics, and more attention should be paid for its effective prevention and treatment.

    Release date:2016-08-31 05:47 Export PDF Favorites Scan
  • 全髋关节置换术中髋臼侧骨缺损的处理

    【摘要】目的 总结全髋关节置换术和翻修术中髋臼侧骨缺损重建的方法及疗效。方法 回顾2002年7月-2009年6月行全髋置换术和翻修术中发生髋臼侧骨缺损21例(23髋)。根据美国骨科医师协会(AAOS)分型法,Ⅰ型11髋,Ⅱ型6髋,Ⅲ型5髋,Ⅳ型1髋。分别采用大直径非骨水泥假体臼、非骨水泥假体臼加松质颗粒植骨、骨水泥假体臼加Cage加松质颗粒植骨,以及骨水泥假体臼加定制型假体加松质颗粒植骨等方法,对不同类型髋臼骨缺损进行修复。术后定期随访,采用Harris方法评估髋关节功能,根据X线片判断假体是否有松动,移植骨是否愈合。结果 21例均获随诊6~84个月,平均12个月。术后Harris评分平均85分,较术前平均改善36分。随访复查X线片无假体松动下沉,术后8个月可见移植骨宿主骨交界处有连续骨痂形成。结论 在全髋关节置换术或翻修术中,大部分髋臼侧骨缺损可使用较大型号非骨水泥假体或加松质颗粒植骨进行修复;对于影响假体稳定性较大缺损,使用骨水泥假体臼加Cage加松质颗粒植骨的方法可获得良好效果;一些新型Cage在处理严重髋臼骨缺损中有独特优势,具有良好的临床应用前景。

    Release date:2016-09-08 09:31 Export PDF Favorites Scan
  • ANTIBIOTIC-IMPREGNATED ARTICULAR CEMENT SPACER FOR TREATMENT OF PERIPROSTHETIC JOINT INFECTION

    ObjectiveTo investigate the current problems and corresponding solutions regarding the use of antibiotic-impregnated cement spacer for the treatment of periprosthetic joint infection (PJI). MethodsA retrospective analysis was made on the clinical data of 27 patients with PJI who underwent two-stage revision with antibiotic-impregnated cement spacer between January 2001 and January 2013. There were 12 males and 15 females, with an average age of 62.7 years (range, 25-81 years). All arthroplasties were unilateral, including 19 hip PJI and 8 knee PJI. The mean duration from primary arthroplasty to PJI was 25 months (range, 3-252 months). After infection was controlled with the antibiotic-impregnated cement spacer combined with systematic antibiotics treatment, two-stage revision was performed. The effectiveness was evaluated. ResultsOne patient died of myocardial infarction at 2 days after surgery. Infection was controlled, and two-stage revision was successfully performed in 19 patients; deep venous thrombosis occurred in 1 of 3 patients who experienced hip spacer fractures, which was cured after conservative management. The spacers were removed and bacteria-sensitive antibiotics was used because of recurrent infections after the first-stage surgery in 7 patients; 3 patients gave up treatment because infection was not controlled, 4 patients received revision after infection was controlled. Twenty-three patients were followed up 1-5 years (mean, 2.3 years). The average Harris hip score and KSS score at 1 years after revision were significantly improved when compared with preoperative ones (P<0.05). In the 8 patients with gram-negative or fungus infection, 7 were found to have recurrent infection after the first-stage surgery; in the 12 patients with gram-positive infection, no recurrent infection was found. Failed treatment was observed in 1 patient with gram-positive and gram-negative infections and 2 with fungus infection, respectively. ConclusionAntibiotic-impregnated cement spacer has a satisfactory effectiveness for PJI. However, complication of spacer fracture should be noted, especially hip spacers. If the pathogen is gram-negative bacteria or fungus, the implanted spacer may increase the possibility of recurrent infection.

    Release date: Export PDF Favorites Scan
  • SHORT-TERM FOLLOW-UP OF RIBBED ANATOMIC CEMENTLESS TOTAL HIP ARTHROPLASTY

    Objective To summarize the clinical outcome of the Ribbed anatomic cementless total hip arthroplasty (THA) in the treatment of hip-joint disease. Methods From January 2001 to June 2005, 34 patients(38 hips) with hip-joint disease were treated with Ribbed anatomic cementless THA. Their ages ranged from 29 to 55 years with an average age of 42.7 years.The disease course was from 3 to 18 years. Among these cases, there were 7 cases (7 hips) of femoral neck fracture, 5 cases(5 hips) of traumatic arthritis after fracture of acetabulum, 15 cases(16 hips) of necrosis of the femoral head and 7 cases(10 hips) of ankylosing spondylitis. Four patients were operated on both hip joints. The average Harris hip score was 38.6(25-57) before operation. Results Twenty-one patients(23 hips) were followed up 861 months with an average of 35 months. The Harris hip score was 76-98 after operation with an average of 92.3, showing significant difference when compared with that before operation(Plt;0.05). The excellent and good result was achieved in 93.5 % of patients. Radiographs showed no prosthetic osteolysis and no evidence of loosening. Pain in the thigh occurred in 4 patients,and it can be relieved by using nonsteroid antiinflammatory drug. Conclusion Ribbed anatomic cementless THA has good clinical and radiographic results in treating patients with hip-joint disease.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • 人工关节在四肢恶性骨肿瘤保肢重建功能中的应用

    目的 探讨人工关节置换在恶性骨肿瘤保肢术中的应用价值。方法 2000年3月~2005年8月收治48例恶性骨肿瘤,男23例,女25例;年龄15~47岁,平均21岁。其中骨肉瘤位于股骨远端15例,近端7例,肱骨近端9例,胫骨近端5例;软骨肉瘤位于股骨近端3例,肱骨近端2例,胫骨近端1例;尤文瘤5例,位于股骨近、远端各2例,股骨近端1例;股骨远端恶性纤维组织细胞瘤1例。病程3个月~2年。参照Enneking分期标准,ⅠB期2例,ⅡA期22例,ⅡB期24例。均进行人工关节置换术。结果 术后48例获12~65个月随访。术后3例皮下积液,2例局部皮肤坏死换药后治愈,迟发感染1例,经引流抗感染治愈;3例疼痛,1例服止痛药,2例能忍受;1例外伤后股骨上段假体折断,行翻修术后可行走。2例术后分别于8、17个月局部复发行截肢术。术后1~2年肺转移7例,2~3年肺转移4例,恶性肿瘤最终保肢率93.8%。参照Enneking骨骼肌肉肿瘤术后肢体功能评定标准,获优18例,良21例,可5例,差4例。结论 辅以综合治疗,人工假体置换术是四肢恶性骨肿瘤保肢、重建功能的一种有效方法。

    Release date:2016-09-01 09:23 Export PDF Favorites Scan
  • THE EFFECT OF ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE PARTICLE ON THE TISSUES OF JOINT PROSTHESIS

    Objective To study the effect of the high molecular weight polyethylene on the periprosthetic tissue in vivo as to give some reference to treatment of loosening hip arthroplasty. Methods Every lower limb of 20 New Zealand white rabbits was implanted a CoCrMo plug in femur by intercondylar notch. 15 mg polyethylene particles, dispersed in 1.5 ml normal saline solution, were injected into one knee joint. The other knee joint was injected 1.5 ml normal saline solution as control. This procedure was repeated 2,4,6,8 and 10 weeks after the implantation. Both of two lower limbs were given a X-ray examination 10 weeks to assess if there were periprosthetic osteolysis and loosening of the plugs. All animals were killed 2 weeks afer the last injection. The distribution of polyethylene in the knee joint capsule was examined to understand if there were loosening of implants or tissue change around implants. Knee joint capsule tissues and periprosthetic tissues were examed by optical microscope. Results Nine cases formed fibrous membrane and four cases formed new bone around prostheses in experiment group. Eleven cases formed new bone and two cases formed fibrous membrane in control group(Plt;0.05)The X-ray results indicated that the plugs were in distal medulla of femur. There was no sign of priprosthetic osteolysis, implants loosening or new bone formation. Optical microscope study indicated that there were a lot of polyethylene particles inside the capsule. The polythlene particles were surrounded by multinucleated foreignbody giant cells and fibrobast. In some cases, there were fibroblasts and fibrous tissue around plug. There were no polyethylene paticles and multinucleated foreignbody giant cells around plug in the marrow. There were alot of polyehtlene particles on the joint surface. The bone surface that contacted multinucleated foreignbody giant cells was coarse. Conclusion Maximing ultra high molecular weight polyethylene can restrain rabbit periprosthetic bone formation

    Release date:2016-09-01 09:27 Export PDF Favorites Scan
5 pages Previous 1 2 3 4 5 Next

Format

Content