Early screening is an important means to reduce breast cancer mortality. In order to solve the problem of low breast cancer screening rates caused by limited medical resources in remote and impoverished areas, this paper designs a breast cancer screening system aided with portable ultrasound Clarius. The system automatically segments the tumor area of the B-ultrasound image on the mobile terminal and uses the ultrasound radio frequency data on the cloud server to automatically classify the benign and malignant tumors. Experimental results in this study show that the accuracy of breast tumor segmentation reaches 98%, and the accuracy of benign and malignant classification reaches 82%, and the system is accurate and reliable. The system is easy to set up and operate, which is convenient for patients in remote and poor areas to carry out early breast cancer screening. It is beneficial to objectively diagnose disease, and it is the first time for the domestic breast cancer auxiliary screening system on the mobile terminal.
Portable electrocardiogram monitor is an important equipment in the clinical diagnosis of cardiovascular diseases due to its portable, real-time features. It has a broad application and development prospects in China. In the present review, previous researches on the portable electrocardiogram monitors have been arranged, analyzed and summarized. According to the characteristics of the electrocardiogram (ECG), this paper discusses the ergonomic design of the portable electrocardiogram monitor, including hardware and software. The circuit components and software modules were parsed from the ECG features and system functions. Finally, the development trend and reference are provided for the portable electrocardiogram monitors and for the subsequent research and product design.
Objective To investigate the physiological effects of different oxygen injection site on ventilatory status and oxygenation during noninvasive positive pressure ventilation ( NPPV) with portable noninvasive ventilators. Methods A prospective crossover randomized study was performed. Oxygen injection site was randomized into the outlet of the ventilator, the connection site between mask and circuit, and the mask under the condition of leak port immobilized in the mask. Oxygen flow was retained in the baseline level at the initial 5 to 10 minutes, and adjusted to obtain arterial oxygen saturation measured by pulse oximetry ( SpO2 ) ranging from 90% to 95% after SpO2 remains stable. SpO2 at the initial 5 to 10 minutes, oxygen flow, ventilatory status, oxygenation, hemodynamics and dyspnea indexes at0. 5 hour, 1 hour, and 2 hours of NPPV were compared between different oxygen injection sites. Results 10 patients were recruited into the study. Under the condition of the same oxygen flow, SpO2 with oxygen injection site in the outlet of the ventilator was significantly higher than that with oxygen injection site in the connection site between mask and circuit [ ( 98.9 ±0.9) % vs. ( 96.9 ±1.1) % , P =0. 003] , whereas SpO2 with oxygen injection site in the connection site between mask and circuit was significantly higher than that with oxygen injection site in the mask [ ( 96.9 ±1.1) % vs. ( 94.1 ±1.6) %, P = 0.000] . Oxygen flow with oxygen injection site in the mask was statistically higher than that with oxygen injection site at other sites ( P lt; 0.05) . Arterial oxygen tension/ oxygen flow with oxygen injection site in the outlet of the ventilator was significantly higher than that with oxygen injection site in the connection site between mask and circuit ( 67.9 ±31.1 vs. 37.0 ±15.0, P =0.007) , and than that with oxygen injection site in the mask ( 67.9 ± 31.1 vs. 25.0 ±9.1, P = 0.000) . pH, arterial carbon dioxide tension, hemodynamics and dyspnea indexes were not significantly different between different oxygen injection sites ( P gt; 0.05) .Conclusions When portable noninvasive ventilator was applied during NPPV, oxygen injection site significantly affects improvement of oxygenation, and shows a trend for affecting ventilatory status and work of breathing. When the leak port was immobilized in the mask, the nearer oxygen injection site approaches the outlet of the ventilator, the more easily oxygenation is improved and the lower oxygen flow is demanded.
The current quantitative methods of bilirubin have disadvantages such as high cost and low sensitivity. Due to the negative correlation between the level of serum bilirubin and the risk of cardiovascular diseases, a fluorescent ratiometric film sensor was developed aiming at bilirubin detection at low level concentration. Blue-emitting and red-emitting gold nanoclusters were assembled into the same film using layer-by-layer self-assembly technology. Detection of bilirubin was achieved based on the intensity ratio of the two nanoclusters. Bilirubin exposure causes fluorescent quenching of the film. The fluorescence intensity ratio of the two cluster probes had quantitative relationship versus bilirubin concentration. Based on this film sensor, a portable fluorescence detection system was designed for the ratiometric sensing of bilirubin. The hardware of the system was mainly composed of main control chip STM32F407, TSL237 and TSL238T optical frequency sensor. A light-avoiding dark room and detection light path were designed through three-dimensional printing to reduce the interference from ambient light and improve detection accuracy. Experimental results showed that the proposed detection system had strong anti-interference, good stability and accuracy. The linear coefficient of bilirubin detected by this system was 0.987. The system presented good results in reproducible experiments and possessed a good linear relationship with the data obtained by standard spectrofluorometer. The portable system is expected to detect serum bilirubin at low levels.
Blood purification is not only an effective treatment for patients with acute and chronic renal failure, but also plays an important role in the rescue of various critically ill patients. The current blood purification devices is relatively bulky and not suitable for use in daily life and disaster rescue sites. Portable blood purification devices can be divided into portable artificial kidney, wearable artificial kidney, implantable artificial kidneys and mobile continuous renal replacement therapy machine, which have not yet been widely applied in clinical practice. In recent years, with the advancement of materials science and computer science, efficient regeneration of dialysate and intelligent operation of equipment have become possible, and portable blood purification devices is also expected to experience rapid development. This article briefly reviews the development history and future research directions of portable blood purification devices.
Objective To understand the demands on portable medicine kit of rural residents in well-off township hospitals, and to provide the basis for scientifically designing portable medicine kit for rural residents. Methods The methods of combining simple random sampling and cluster sampling were used to investigate and analyze the demands on portable medicine kit for 162 households from three well-off township hospitals in Shanghai, Zhejiang, and Sichuan province, respectively. Results The demand rate of 162 rural households on portable medicine kit was 75.3% (122/162). The main drugs that demanders expected in the portable medicine kit were cold medicine (86.1%), wound paste (82.0%), cooling oil (61.5%), essential balm (54.9%) and antihypertensive (34.4%); and the main medical devices that demanders expected were thermometer (82%), cotton swab (73%) and sphygmomanometer (32.8%). The sizes of portable medicine kit that demanders expected were 23.7±8.5 cm in length, 17.1±6.4 cm in width, and 14.1±6.5 cm in height. The main function characteristics of portable medicine kit that demanders expected were applicability (74.6%), safety (60.7%), light weight (68.0%), economics (60.7%), and waterproof (46.7%). A total of 72.1% of demanders expected the price of less than 15 yuan, and 91.8% expected kit made of hard materials as plastic as the first choice. Conclusion The demand rate of rural residents on portable medicine kit is higher in well-off township hospital. The design and production of portable medicine kit should fully meet the demands of rural residents. Only when sufficiant respect for the market demand is paid, can the promotion and application of portable kits will be ensured.
Objective To discuss the application value in increasing the frequency of monitoring and ensuring the safety of anticoagulation therapy in patient self-monitoring (PST) and self-management (PSM) of portable coagulometer. Method This non-randomized prospective controlled study was conducted in 100 patients receiving oral warfarin anticoagulation therapy after heart valve replacement and met the inclusion criteria in our hospital between March 2013 and April 2014 year. All the patients were divided into three groups including an outpatient follow-up group(outpatient group), a self-monitoring group and a self-management group. Meanwhile, the patients in the outpatient group visited professional institutions, performed international normalized ratio (INR) testing with central lab and adjusted the dosage of orally administered warfarin by the doctors. And the other two groups performed INR testing with CoaguChek XS portable coagulometer by themselves, and the patients in the self-management group performed management by themselves. The follow-up time was 6 months. The dates of time in therapeutic range (TTR), fraction of time in therapeutic range (FTTR) and anticoagulation complications in the three groups were analyzed and compared. Results There was no significant difference in the INR results obtained from the follow-up time among the three groups (P=0.845) . TTR value of INR of the outpatient group, the self-monitoring group, and the self-management group was 45.9% (4368.0 days/9517.0 days), 61.2% (6057.0 days/9897.0 days), and 65.4% (2833.8 days/4333.0 days), respectively with a statistical difference among the three groups (P<0.001) . FTTR value of INR obtained from the outpatient group, the self-monitoring group, and the self-management group was 48.3% (99 times/205 times), 60.7% (164 times/270 times), and 64.9% (100 times/154 times) respectively. There was a statistical difference in the FTTR between the outpatient group and the self-monitoring group (P=0.007) , and also between the outpatient group and the self-monitoring group (P=0.002) . But there was no statistical difference between the self-monitoring group and the self-management group (P=0.392) . There were not any major bleeding and thrombosis complications in all study. And there was no statistical difference in the total complications, thrombosis, and bleeding complications rates between the outpatient group and the self-monitoring group, and also between the outpatient group and the self-management group (P>0.05) . Conclusions The patients receiving oral anticoagulation after heart valve replacement or their care providers were able to perform PST and PSM. The use of portable coagulometer for self-monitoring and self-management can increase the frequency of anticoagulation monitoring and achieve better INR target value control. PST and PSM could achieve higher quality of anticoagulation management and life and without increasing the risk of oral anticoagulation than the traditional monitoring method. The monitoring frequency of once a month is reasonable for the patients receiving oral anticoagulation more than half a year after heart valve replacement.