west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "便携式" 17 results
  • Design and implementation for portable ultrasound-aided breast cancer screening system

    Early screening is an important means to reduce breast cancer mortality. In order to solve the problem of low breast cancer screening rates caused by limited medical resources in remote and impoverished areas, this paper designs a breast cancer screening system aided with portable ultrasound Clarius. The system automatically segments the tumor area of the B-ultrasound image on the mobile terminal and uses the ultrasound radio frequency data on the cloud server to automatically classify the benign and malignant tumors. Experimental results in this study show that the accuracy of breast tumor segmentation reaches 98%, and the accuracy of benign and malignant classification reaches 82%, and the system is accurate and reliable. The system is easy to set up and operate, which is convenient for patients in remote and poor areas to carry out early breast cancer screening. It is beneficial to objectively diagnose disease, and it is the first time for the domestic breast cancer auxiliary screening system on the mobile terminal.

    Release date:2022-06-28 04:35 Export PDF Favorites Scan
  • Advances of Portable Electrocardiogram Monitor Design

    Portable electrocardiogram monitor is an important equipment in the clinical diagnosis of cardiovascular diseases due to its portable, real-time features. It has a broad application and development prospects in China. In the present review, previous researches on the portable electrocardiogram monitors have been arranged, analyzed and summarized. According to the characteristics of the electrocardiogram (ECG), this paper discusses the ergonomic design of the portable electrocardiogram monitor, including hardware and software. The circuit components and software modules were parsed from the ECG features and system functions. Finally, the development trend and reference are provided for the portable electrocardiogram monitors and for the subsequent research and product design.

    Release date: Export PDF Favorites Scan
  • Physiological Effects of Oxygen Injection Site during Noninvasive Positive Pressure Ventilation

    Objective To investigate the physiological effects of different oxygen injection site on ventilatory status and oxygenation during noninvasive positive pressure ventilation ( NPPV) with portable noninvasive ventilators. Methods A prospective crossover randomized study was performed. Oxygen injection site was randomized into the outlet of the ventilator, the connection site between mask and circuit, and the mask under the condition of leak port immobilized in the mask. Oxygen flow was retained in the baseline level at the initial 5 to 10 minutes, and adjusted to obtain arterial oxygen saturation measured by pulse oximetry ( SpO2 ) ranging from 90% to 95% after SpO2 remains stable. SpO2 at the initial 5 to 10 minutes, oxygen flow, ventilatory status, oxygenation, hemodynamics and dyspnea indexes at0. 5 hour, 1 hour, and 2 hours of NPPV were compared between different oxygen injection sites. Results 10 patients were recruited into the study. Under the condition of the same oxygen flow, SpO2 with oxygen injection site in the outlet of the ventilator was significantly higher than that with oxygen injection site in the connection site between mask and circuit [ ( 98.9 ±0.9) % vs. ( 96.9 ±1.1) % , P =0. 003] , whereas SpO2 with oxygen injection site in the connection site between mask and circuit was significantly higher than that with oxygen injection site in the mask [ ( 96.9 ±1.1) % vs. ( 94.1 ±1.6) %, P = 0.000] . Oxygen flow with oxygen injection site in the mask was statistically higher than that with oxygen injection site at other sites ( P lt; 0.05) . Arterial oxygen tension/ oxygen flow with oxygen injection site in the outlet of the ventilator was significantly higher than that with oxygen injection site in the connection site between mask and circuit ( 67.9 ±31.1 vs. 37.0 ±15.0, P =0.007) , and than that with oxygen injection site in the mask ( 67.9 ± 31.1 vs. 25.0 ±9.1, P = 0.000) . pH, arterial carbon dioxide tension, hemodynamics and dyspnea indexes were not significantly different between different oxygen injection sites ( P gt; 0.05) .Conclusions When portable noninvasive ventilator was applied during NPPV, oxygen injection site significantly affects improvement of oxygenation, and shows a trend for affecting ventilatory status and work of breathing. When the leak port was immobilized in the mask, the nearer oxygen injection site approaches the outlet of the ventilator, the more easily oxygenation is improved and the lower oxygen flow is demanded.

    Release date:2016-09-13 03:53 Export PDF Favorites Scan
  • Design and implementation of ratiometric fluorescence detection system for serum bilirubin

    The current quantitative methods of bilirubin have disadvantages such as high cost and low sensitivity. Due to the negative correlation between the level of serum bilirubin and the risk of cardiovascular diseases, a fluorescent ratiometric film sensor was developed aiming at bilirubin detection at low level concentration. Blue-emitting and red-emitting gold nanoclusters were assembled into the same film using layer-by-layer self-assembly technology. Detection of bilirubin was achieved based on the intensity ratio of the two nanoclusters. Bilirubin exposure causes fluorescent quenching of the film. The fluorescence intensity ratio of the two cluster probes had quantitative relationship versus bilirubin concentration. Based on this film sensor, a portable fluorescence detection system was designed for the ratiometric sensing of bilirubin. The hardware of the system was mainly composed of main control chip STM32F407, TSL237 and TSL238T optical frequency sensor. A light-avoiding dark room and detection light path were designed through three-dimensional printing to reduce the interference from ambient light and improve detection accuracy. Experimental results showed that the proposed detection system had strong anti-interference, good stability and accuracy. The linear coefficient of bilirubin detected by this system was 0.987. The system presented good results in reproducible experiments and possessed a good linear relationship with the data obtained by standard spectrofluorometer. The portable system is expected to detect serum bilirubin at low levels.

    Release date:2022-10-25 01:09 Export PDF Favorites Scan
  • 便携式超声仪探头的巧妙管理

    Release date: Export PDF Favorites Scan
  • 自制便携式治疗车在急诊科的应用

    Release date: Export PDF Favorites Scan
  • Past and present of portable blood purification devices

    Blood purification is not only an effective treatment for patients with acute and chronic renal failure, but also plays an important role in the rescue of various critically ill patients. The current blood purification devices is relatively bulky and not suitable for use in daily life and disaster rescue sites. Portable blood purification devices can be divided into portable artificial kidney, wearable artificial kidney, implantable artificial kidneys and mobile continuous renal replacement therapy machine, which have not yet been widely applied in clinical practice. In recent years, with the advancement of materials science and computer science, efficient regeneration of dialysate and intelligent operation of equipment have become possible, and portable blood purification devices is also expected to experience rapid development. This article briefly reviews the development history and future research directions of portable blood purification devices.

    Release date:2024-08-21 02:11 Export PDF Favorites Scan
  • Design of portable blood pressure depressor based on slow breathing training

    Clinical studies had demonstrated that slow breathing could lower blood pressure significantly. Based on this knowledge, a portable blood pressure depressor was designed in this study. The device used a miniature variable distance capacitive sensor to collect respiratory signal, an STM32 as the main control chip, a WT588D voice chip to generate voice and music and guide slow breathing, and a 3.5-inch color screen to display breathing state and provide guidance. For patients with difficulty in adapting themselves to the slow breathing training, an intelligent guiding breathing algorithm based on feedback regulation mechanism was proposed to train patients to breathe slowly. Ten volunteers with hypertension were recruited and then trained to breathe slowly, accumulating up to 100 times using this device. The results showed that breath rate of the volunteers decreased from 15.16±0.92 times per minute to 9.40±0.29 times per minute, and meanwhile, time length of breath rate less than 8 times per minute in the proportion of total treatment time increased from 0.079±0.017 to 0.392±0.019 as the training times increased. In a conclusion, the proposed blood pressure depressor worked effectively in guiding slow breathing training.

    Release date:2017-04-13 10:03 Export PDF Favorites Scan
  • i-STAT便携式血气分析仪在连续性肾脏替代治疗中的应用

    目的 讨论i-STAT便携式血气分析仪在连续性肾脏替代治疗(CRRT)中的应用。 方法 2012年2月-5月,对92例行CRRT治疗患者采用i-STAT便携式血气分析仪监测分析治疗中各参数变化并及时予以调整。 结果 92例患者治疗中酸碱及电解质的失衡得到及时调整,无意外情况发生。 结论 i-STAT便携式血气分析仪在CRRT治疗中能较好的监测患者的血气及电解质,确保CRRT的安全完成。

    Release date:2016-09-07 02:34 Export PDF Favorites Scan
  • Demands Assessment on Portable Medicine Kit of Rural Households among Model Well-off Township Hospital in Eastern, Central and Western China

    Objective To understand the demands on portable medicine kit of rural residents in well-off township hospitals, and to provide the basis for scientifically designing portable medicine kit for rural residents. Methods The methods of combining simple random sampling and cluster sampling were used to investigate and analyze the demands on portable medicine kit for 162 households from three well-off township hospitals in Shanghai, Zhejiang, and Sichuan province, respectively. Results The demand rate of 162 rural households on portable medicine kit was 75.3% (122/162). The main drugs that demanders expected in the portable medicine kit were cold medicine (86.1%), wound paste (82.0%), cooling oil (61.5%), essential balm (54.9%) and antihypertensive (34.4%); and the main medical devices that demanders expected were thermometer (82%), cotton swab (73%) and sphygmomanometer (32.8%). The sizes of portable medicine kit that demanders expected were 23.7±8.5 cm in length, 17.1±6.4 cm in width, and 14.1±6.5 cm in height. The main function characteristics of portable medicine kit that demanders expected were applicability (74.6%), safety (60.7%), light weight (68.0%), economics (60.7%), and waterproof (46.7%). A total of 72.1% of demanders expected the price of less than 15 yuan, and 91.8% expected kit made of hard materials as plastic as the first choice. Conclusion The demand rate of rural residents on portable medicine kit is higher in well-off township hospital. The design and production of portable medicine kit should fully meet the demands of rural residents. Only when sufficiant respect for the market demand is paid, can the promotion and application of portable kits will be ensured.

    Release date:2016-09-07 11:07 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content