west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "全髋关节" 230 results
  • PRELIMINARY EXPERIENCES IN MINIMALLY INVASIVE AND MINIINCISION SURGERY TOTAL HIP ARTHROPLASTY FOR LATE OSTEONECROSIS OF THE FEMORAL HEAD

    Objective To explore the effect of minimally invasive and mini-incision surgery (MIS) in total hip arthroplasty (THA) on late osteonecrosis of femoral head (ONFH). Methods From March 2003, Eighteen patients (22 hips) with ONFH underwent MIS in THA. Their ages ranged from 24to 57 years, including 13 males and 5 females. The mean body mass index ranged from 17.1 to 30.1(24.6 on average). The Harris hip score was 46 points before operation. Modified posterior-lateral approach was adopted, and the MIS THA was performed by cementless prosthesis. As a comparison, 18 patients (22 hips) were performed by conventional THA at the same period. The data, including bleeding volume during operation, incision length, operative time, and postoperative function recovery, were compared. Results Follow-ups were done for 6 to 20 months (11 months on average). Dislocation occurred in one patient that underwent conventional THA 2 days after operation. No complication occurred in MIS THA group. The incision lengths ranged from 8.7 to 10.5 cm (9.3 cm on average) in MIS THA group, being statistically different (Plt;0.01). There was no significant difference in Harris scoring of the function between the two groups both before the operation and after the operation (Pgt;0.05). The operative time was almost the same, but the bleeding volume in MIS THA group was less (Plt;0.05). The function recovery was faster in MIS THA group.Conclusion The MIS THA is an alternative to the treatment of late ONFH. The advantages of MIS THA are fewer trauma, less bleeding volume, and faster recovery. The MIS THA should be performed by surgeons with rich experiences in THA and hospitals with necessary instruments. 

    Release date:2016-09-01 09:30 Export PDF Favorites Scan
  • ACCURACY IMPROVEMENT OF ACETABULAR COMPONENT PLACEMENT USING NONIMAGE BASED SURGICAL NAVIGATION SYSTEM

    Objective To improve the accuracy of the acetabular component placement using the nonimage based surgical navigation system. Methods Twenty-three patients (14 males, 9 females; age, 28-55 years;26 hips)with hip disease underwent the total hip arthroplasty (THA) using the nonimage based surgicalnavigation system from February 2004 to April 2006. Rheumatoid arthritis was found in 3 patients (3 hips), necrosis of the femoral head in 6 patients (6 hips), and osteoarthritis in 14 patients (16 hips). All the patients were randomly divided into the following 2 groups: the navigated group (11 patients, 13 hips), treated by THA using the nonimage based surgical navigation system; and the control group (12 patients, 13 hips), treated by the traditional THA. According to thedesign of the study, the acetabular component was placed in the best inclination angle (45°) and the anteversion angle (15°). The postoperative component position was examined. Results No fracture, dislocation, infection or injury to the sciatic nerve was found. In the navigated group, the inclination and the anteversion reached 15.4±1.4° and 45.5±1.3°, respectively. In the control group,the inclination and the anteversion were 13.9±7.6° and 43.7±6.4°, respectively. The inclination difference was considered statistically significant (Plt;0.01). All the patients were followed up for 10-40 months,averaged 26 months. In the navigated group, the postoperative average Harris hip score was 95 (range,85-110), with an excellent result in 11 hips and a good result in 2 hips. In the control group, the postoperative average Harris hip score was 92 (range,75-110), with an excellent result in 9 hips, a good result in 3 hips, and a fair result in 1 hip. The Harris hip score difference was considered statistically significant (Plt;0.05). There was a significantly better result obtained in the navigated group than in the control group. Conclusion The acetabular component can be implanted accurately by the nonimage based surgical navigation system, which can reduce the incidence of the loosening of the prostheses and has an important value in clinical practice.

    Release date:2016-09-01 09:20 Export PDF Favorites Scan
  • Meta-analysis of leg length discrepancy after robot-assisted and traditional total hip arthroplasty

    Objective To systematically evaluate the difference in leg length discrepancy (LLD) between robot-assisted total hip arthroplasty (THA) and traditional THA. Methods The Cochrane Library, PubMed, Web of Science, EMbase, CNKI, Wanfang, VIP, and CBM databases were searched by computer to collect cohort studies of robot-assisted and traditional THAs from inception to August 11th, 2021. Two researchers independently screened the literature, extracted the data, and evaluated the risk of bias of the included studies. Meta-analysis was performed using RevMan 5.3 software. ResultsA total of 10 high-quality cohort studies were included. The results of Meta-analysis showed that compared with traditional THA, LLD after robot-assisted THA was smaller [MD=−1.64, 95%CI (−2.25, −1.04), P<0.001], Harris scores at 3 and 12 months after operation were higher [MD=1.50, 95%CI (0.44, 2.57), P=0.006; MD=7.60, 95%CI (2.51, 12.68), P=0.003]. However, the operative time was longer [MD=8.36, 95%CI (4.56, 12.17), P<0.000 1], and the postoperative acetabular anteversion angle was larger [MD=1.91, 95%CI (1.43, 2.40), P<0.001]. There was no significant difference in Harris score at 6 months, amnesia index (Forgotten joint score, FJS), postoperative acetabular abduction angle, and incidence of complication between the two groups (P>0.05). Conclusion Robot-assisted THA is superior to traditional THA in postoperative LLD.

    Release date:2022-06-08 10:32 Export PDF Favorites Scan
  • Early effectiveness of robot-assisted total hip arthroplasty via direct superior approach

    ObjectiveTo evaluate the early effectiveness of the robot-assisted total hip arthroplasty (THA) via direct superior approach (DSA).MethodsBetween March 2021 and April 2021, 11 patients (11 hips) were treated with a robot-assisted THA via DSA. There were 7 males and 4 females, with an average age of 55 years (range, 26-73 years). There were 5 patients of osteoarthritis secondary to hip dysplasia and 6 patients of osteonecrosis of femoral head. Preoperative hip Harris score was 55.8±6.3. The operation time, volume of blood loss, length of incision, postoperative blood transfusion and hospital stay, and the incidence of surgical complications were recorded. The visual analogue scale (VAS) score and Harris score were used to evaluate hip joint pain and function. The leg length discrepancy (LLD) was measured on the X-ray films. The inclination angle and anteversion angle of the acetabular component were also measured, and the difference between the planned and actual values were compared.ResultsOne THA was performed via conventional posterolateral approach finally because of poor exposure. The rest of 10 THAs were performed with assistance of robotic arm via DSA. The average operation time was 89 minutes (range, 65-120 minutes); the average length of incision was 10.5 cm (range, 9-13 cm); and the average blood loss was 400 mL (range, 110-740 mL). One patient was given a blood transfusion for 2 unit. All incisions healed by first intention and no neurovascular injury, deep vein thrombosis, or fracture occurred. The length of hospital stay after operation was 2-6 days (mean, 4.4 days). The duration of follow-up was 1-3 months (mean, 2.1 months). The VAS score was 0 in 9 patients and 2 in 1 patient at the day of discharge. At last follow-up, the hip Harris score was 84.9±6.7, showing significant difference when compared with that before operation (t=−8.717, P=0.000). The inclination and anteversion angles were (37.4±2.0)° and (17.1±4.5)°, respectively, and there was no significant difference when compared with the planned values [(38.2±1.6)°, (16.6±3.7)°] (t=1.809, P=0.104; t=–1.103, P=0.299). The LLD ranged from –2 to 4 mm. No complication such as dislocation, aseptic loosening, or periprosthetic joint infection occurred. ConclusionThe robot-assisted THA via DSA has encouraged early effectiveness.

    Release date:2021-10-28 04:29 Export PDF Favorites Scan
  • Long-term computed tomographic osteolytic analysis of highly cross-linked polyethylene prosthesis after total hip arthroplasty

    Objective To analyze the occurrence of osteolysis in total hip arthroplasty (THA) with highly cross-linked polyethylene prosthesis during a follow-up of more than 15 years. Methods The clinical data of 84 patients (105 hips) treated with THA in the Affiliated Hospital of Kanazawa Medical University in Japan between June 2000 and April 2004 and met the selection criteria was retrospectively analyzed. There were 7 males and 77 females, aged from 41 to 75 years, with an average of 56.4 years. There were 94 hips with secondary hip osteoarthritis, 4 hips after pelvic osteotomy, 2 hips with primary hip osteoarthritis, 2 hips with traumatic hip osteoarthritis, 2 hips with osteonecrosis of the femoral head, and 1 hip with rheumatoid arthritis. According to Crowe classification, there were 79 hips of type Ⅰ, 19 hips of type Ⅱ, 6 hips of type Ⅲ, and 1 hip of type Ⅳ. The highly cross-linked polyethylene acetabular liner combined with a 26 mm zirconia femoral head were used in all patients. X-ray films were taken after operation to analyze the radiation transmission and osteolysis around the acetabular prosthesis. The vertical distance (the distance between the teardrop line at the lower edge of the pelvis and the perpendicular line of the hip rotation center), the horizontal distance (the horizontal distance between the hip rotation center and the interteardrop line and the vertical line at the lower edge of the teardrop), and the acetabular cup anteversion angle were measured at last follow-up. The acetabular and femoral osteolysis was analyzed by CT scan and three-dimensional multiplanar reconstruction (3D-MPR). Combined with X-ray film and CT results, osteolysis was evaluated according to the Narkbunnam score. Results Deep vein thrombosis of lower limbs occurred in 2 cases. All patients were followed up 15-18 years, with an average of 15.9 years. One hip dislocation and 1 periprosthetic fracture occurred postoperatively, and no acetabular loosening or prosthetic lining ruptures occurred. Except for 1 patient who had a radiolucent line in the acetabulum after operation, the other 83 patients did not show any radiolucent line in the acetabulum or the femur. None of the patients underwent hip revision. X-ray films at last follow-up showed an acetabular cup anteversion angle of −10°-39°, with an average of 22°; a vertical distance of 3.5-47.1 mm, with an average of 24.6 mm; and a horizontal distance of 22.6-48.1 mm, with an average of 31.7 mm. There was no acetabular or femoral osteolysis in all patients on X-ray films and CT 3D-MPR images at last follow-up, and the Narkbunnam score was 0 in any region. Conclusion Highly cross-linked polyethylene prosthesis does not increase the risk of long-term complications such as osteolysis after THA.

    Release date:2024-10-17 05:17 Export PDF Favorites Scan
  • Comparison of filling ratio, alignment, and stability between ABGⅡ short-stem and Corail long-stem in total hip arthroplasty for Dorr type C femur

    Objective Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem. MethodsAmong patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant (P>0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up (P>0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software. ResultsX-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group (P<0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group (P<0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group (P<0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant (P>0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group (P<0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant (P>0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups (P>0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group (P<0.05). Conclusion Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.

    Release date:2023-06-07 11:13 Export PDF Favorites Scan
  • Effectiveness of autologous femoral head bone graft in total hip arthroplasty for Crowe type Ⅲ developmental dysplasia of hip with acetabular bone defect

    Objective To explore the surgical technique and effectiveness of autologous femoral head bone graft in total hip arthroplasty (THA) for Crowe type Ⅲ developmental dysplasia of the hip (DDH) with acetabular bone defect. Methods Between July 2012 and September 2015, 12 cases (12 hips) of Crowe type Ⅲ DDH with acetabular bone defect were included. Of the 12 patients, 2 were male and 10 were female, with an average age of 54.3 years (range, 37-75 years). The Harris score before operation was 41.08±7.90. The preoperative leg length discrepancy was 0.53-4.28 cm, with an average of 2.47 cm. Autologous femoral head bone graft and cancellous screw fixation were used in all cases to reconstruct acetabula in THA. Four cases were performed with subtrochanteric shortening osteotomy at the same time. Results All incisions healed by first intention. Twelve cases were followed up 1 year and 10 months to 5 years, with an average of 3.0 years. X-ray films showed that bone healing was observed in all cases at 6 months to 1 year after operation. There was no bone graft osteolysis, absorption, bone graft collapse, and acetabular prosthesis loosening. At last follow-up, the Harris score was 89.50±2.78, showing significant difference when compared with preoperative value (t=–25.743, P=0.003). The length discrepancy was 0-1.81 cm at last follow-up with an average of 0.76 cm. Conclusion Autologous femoral head bone graft is effective for Crowe type Ⅲ DDH with acetabular bone defect, which has advantages of restoring pelvic bone stock, obtaining satisfied prosthetic stability and mid-term effectiveness.

    Release date:2018-01-09 11:23 Export PDF Favorites Scan
  • Effectiveness of proximal femur reconstruction combined with total hip arthroplasty for Crowe type Ⅳ developmental dysplasia of hip

    ObjectiveTo investigate the early effectiveness of proximal femur reconstruction combined with total hip arthroplasty (THA) in the treatment of adult Crowe type Ⅳ developmental dysplasia of the hip (DDH).MethodsBetween May 2015 and March 2018, 29 cases (33 hips) suffering from Crowe type Ⅳ DDH were treated with proximal femur reconstruction combined with THA. Of the 29 cases, there were 6 males (7 hips) and 23 females (26 hips), aged from 24 to 74 years with an average age of 44.9 years. The preoperative Harris hip score was 44.0±12.0. Gait abnormalities were found in all of the 33 hips with positive Trendelenburg sign, and the lower limb discrepancy was (3.8±1.6) cm. Preoperative X-ray films and CT both indicated serious anatomical abnormalities, including complete dislocation of the affected hip with significant move-up of the greater trochanter, abnormal development of the femoral neck, abnormal anterversion angle and neck-shaft angle, dysplasia of proximal femur and dysplasia of medullary cavity. The operation time, intraoperative blood loss, transfusion rate, and complications were recorded. The Gruen and DeLee-Charnley zoning methods were used to evaluate the aseptic loosening of the prosthesis on X-ray films. The Harris score was used to evaluate hip function. The lower limb discrepancy was calculated and compared with the preoperative value.ResultsThe operation time ranged from 80 to 240 minutes, with an average of 124.8 minutes. The intraoperative blood loss ranged from 165 to 1 300 mL, with an average of 568.4 mL. Seventeen patients (51.5%) received blood transfusion treatment. All the incisions healed by first intention without infection or deep vein thrombosis. All patients were followed up 19-53 months, with an average of 33 months. One patient had posterior hip dislocation because of falling from the bed at 4 weeks after operation, and was treated with manual reduction and fixation with abduction brace for 4 weeks, and no dislocation occurred during next 12-month follow-up. Two patients developed sciatic nerve palsy of the affected limbs after operation and were treated with mecobalamin, and recovered completely at 12 weeks later. Trendelenburg sign was positive in 3 patients and mild claudication occurred in 4 patients after operation. X-ray films showed that all the osteotomy sites healed at 3-6 months after operation, and no wire fracture was observed during the follow-up. The Harris score was 89.8±2.8 and lower limb discrepancy was (0.6±0.4) cm at last follow-up, both improved significantly (t=–22.917, P=0.000; t=11.958, P=0.000). The prosthesis of femur and acetabulum showed no obvious loosening and displacement, and achieved good bone ingrowth except 2 patients who had local osteolysis in the area of Gruen 1 and 7 around the femoral prosthesis, but no sign of loosening and sinking was observed.ConclusionThe treatment of Crowe Ⅳ DDH with proximal femur reconstruction and THA was satisfactory in the early postoperative period. The reconstruction technique of proximal femur can effectively restore the anatomical structure of proximal femur, which is one of the effective methods to deal with the deformity of proximal femur.

    Release date:2020-07-07 07:58 Export PDF Favorites Scan
  • Effect of Affected Limb’s Function Caused by Postoperative Early Rehabilitative Nursing after Implanting Modular Hemipelvic Prosthesis

    目的:探讨术后早期康复护理干预对骨盆恶性肿瘤半骨盆切除、组合式半骨盆+全髋关节置换术后的患肢功能的影响。方法:从2004年9月至2007年5月采用半骨盆切除、组合式半骨盆假体+全髋关节置换术治疗骨盆恶性骨肿瘤8例。其中软骨肉瘤4例,平滑肌肉瘤2例,骨肉瘤1例,恶性骨巨细胞瘤1例。外科分期:ⅠB期6例,ⅡB期2例。术后根据肿瘤切除范围、人工假体置换术后稳定性和骨盆髋周动力肌修复后的平衡程度,决定术后患肢体位、患髋活动范围、是否使用髋部支具;同时指导患者分阶段、渐进地进行患肢足踝、膝、髋关节的主被动训练,以及下床负重时间和步态调整。结果:随访10~32个月,平均15月。1例术后16个月死于恶性肿瘤扩散转移,7例存活。术后8个月患肢功能评定:优2例,良6例。ISOLS评分:15~26分,平均19.47分。结论:①对骨盆恶性骨肿瘤患者积极进行术后早期康复护理干预能有效的防止人工髋关节早期脱位;②患肢各关节分阶段有序的主动康复护理训练能提高骨盆和髋周肌肉肌力及其平衡度,对维持术后患者行走和步态的稳定有重要意义。

    Release date:2016-08-26 03:57 Export PDF Favorites Scan
  • UTILIZATION OF REINFORCED ACETABULAR CAGES WITH CAUDAL FLANGE IN RECONSTRUCTING PELVIC DEFECT AFTER ACETABULAR TUMOR RESECTION

    Objective To evaluate the surgical procedure of reinforced acetabular cage with caudal flange in reconstruction of pelvic defect after acetabular tumor resection. Methods Between June 2003 and December 2009, 25 patients with Harrington class III pelvic defect underwent reconstruction with a reinforced acetabular cage with caudal flange and total hip arthroplasty (THA). There were 13 males and 12 females with an average age of 51.2 years (range,13-73 years). The main cl inical manifestations included hip pain and buttock pain, with a median disease duration of 6 months (range, 1-96 months). Pathological findings showed 18 cases of metastasis, 3 cases of multiple myeloma, 1 case of non-Hodgkin’s lymphoma, 1 case of grade I chondrosarcoma, 1 case of giant cell tumor, and 1 case of chondroblastoma. For the patient with chondroblastoma, THA with LINK RIBBED system was used. An artificial total hip system made in China was used in 6 patients and LINK SP II system was used in the other 18 patients. Results No patients died perioperatively. Deep infection and hip dislocations occurred in 1 and 2 patients, respectively. At last follow-up, 8 of 18 patients with metastasis died of cancer and the average survival time was 11 months. The other 10 who were al ive were followed up 15 months on average. One patient with multiple myeloma died of pulmonary infection at 21 months after operation and the other 2 with multiple myeloma and 1 with lymphoma were al ive with an average follow-up of 17 months. The patient with grade I chondrosarcoma and patient with chondroblastoma were followed up 58 and 12 months, respectively, without recurrence. Recurrence occurred in the patient with giant cell tumor at 19 months afteroperation. Loosening of implant occurred in 3 patients because of local tumor recurrence. For the 23 patients at 6 months after operation, the mean Musculoskeletal Tumor Society (MSTS) 93 score was 81% (range, 57%-93%). Conclusion Reinforced acetabular cage with caudal flange could be used together with THA for reconstruction of Harrington class III pelvic defects after acetabular tumor resection, and low incidence of postoperative compl ication and good functional outcome could be expected.

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
23 pages Previous 1 2 3 ... 23 Next

Format

Content