ObjectiveTo explore the role of arteriovenous axillary loop graft (AVALG) on chest for establishing hemodialysis access in patients with chronic renal failure. MethodsA retrospective analysis was made on the clinical data of 12 patients with chronic renal failure who underwent an AVALG on chest for hemodialysis access between December 2010 and May 2014. There were 2 males and 10 females with an average age of 65.25 years (range, 46-75 years). The main causes were chronic glomerulonephritis in 6 cases, diabetic nephropathy in 4 cases, and both kidney resection because of urinary tract tumors in 2 cases. The disease duration was 2-12 years (mean, 6 years). The 12 patients all underwent 5-14 times (mean, 7 times) failed prior vascular accesses [arteriovenous fistula (AVF)and arteriovenous graft (AVG)] leading to exhaustion of venous access sites on the upper extremities. ResultsThe AVALG on chest were functionally useful for hemodialysis access, 2-3 times per week, and the blood flow was 250-350 mL/minute; the average time for the first dialysis was 48 days (range, 42-93 days). All patients were followed up 12-54 months (mean, 20.92 months). There was no death during perioperative period. The primary patency rates at 6 and 12 months were 91.7% and 83.3% respectively, and the secondary patency rates at 6 and 12 months were both 100%. After operation, infection (1 case), thrombosis (2 cases), bleeding (2 cases), and swollen (1 case) occurred, which were all cured after corresponding treatment. ConclusionAVALG on chest is a supplementary option for chronic renal failure patients with inadequate upper extremity venous access sites after repeat occlusion.
Venous pressure monitoring is an important indicator for the arteriovenous fistula evaluation. Direct static venous pressure monitoring is recognized as the most accurate way of venous pressure monitoring, which is widely used in the functional monitoring, functional evaluation of arteriovenous fistula, the diagnosis of complications and the evaluation of surgical efficacy. Venous pressure monitoring has obvious advantages and disadvantages, so it is necessary to improve relevant knowledge to correctly guide clinical diagnosis and treatment. In this paper, the study of static venous pressure monitoring of arteriovenous fistula was summarized, in order to improve the understanding of the significance and clinical application of static venous pressure monitoring of arteriovenous fistula.
ObjectiveTo explore the value of ultrasound evaluation and marking before arteriovenous internal fistula in end-stage renal disease hemodialysis patients. MethodsTwenty-five uremia end-stage patients were admitted into our nephrology department from January 2012 to July 2012. All of the patients had encountered several times of fistula failure or had difficulty in establishing the forearm arteriovenous fistula. We focused on observing the brachial artery, radial artery, cephalic vein, the basilica vein and great saphenous vein. We measured the diameter of the vessels and marked the trend of arteries and veins in the body surface under the ultrasonic navigation. Our goal was to look for appropriate bypass vessels in the elbow and the upper arm. ResultsFourteen patients had endured several times of fistula failure. Among the 14 patients, 9 patients completed the surgery of reengineering fistula and autogenous great saphenous vein transplantation, 2 accepted artificial vascular transplantation, 1 completed the removal of blood clots in the left upper limb artificial blood vessels and arteriovenous internal fistula molding, and 2 gave up surgery. Eleven patients could not complete the arteriovenous fistula operation for the fine forearm superficial vein. Of them, 2 patients accepted artificial vascular operation, 6 underwent autogenous great saphenous vein transplantation, 1 with slender radial artery in diameter completed higher position fistula between the brachial artery and median cubital vein, and 2 gave up surgery. ConclusionArteriovenous internal fistula preoperative ultrasound assessment and marking have very important value in improving the success rate of operation in end-stage uremia patients.
Objective To investigate the clinical effect and safety of balloon angioplasty (BAP) for patients with venous hypertension associated with autogenous arteriovenous fistula (AVF). Methods Thirty-three patients with venous hypertension associated with AVF were hospitalized between August 2012 and August 2014 in the Department of Nephrology, West China Hospital of Sichuan University. All of the patients received BAP therapy. The clinical characteristics and therapeutic effects were comparatively summarized before and after operation. Results Venous hypertension in all the 33 patients was caused by central venous stenosis or occlusion. Among them, there were 13 cases of stenosis on the site where the left innominate vein crossed the aorta, 10 cases of stenosis at the junction of the left innominate vein and superior vena cava, 4 cases of stenosis at the junction of the left subclavian vein and the innominate vein, 3 cases of right innominate vein stenosis, and 3 cases of innominate vein occlusion. The lesions were most common in the innominate vein. Innominate vein stenosis or occlusion occurred in 19 cases (57.6%), and stenosis at the junction of innominate vein and the superior vena cava or subclavian vein occurred in 14 cases (42.4%). Of the 33 patients, one patient with complete occlusion of the innominate vein did not receive BAP treatment because guide wire could not pass through the occlusion site. The other 32 patients underwent BAP treatment, among whom 30 (93.8%) were successful, and 2 (6.2%) failed. No obvious complications occurred. One day after BAP treatment, patients’ symptoms were significantly relieved. One to seven days later, swelling of the hands, pain, and other symptoms were relieved. In the 30 patients who underwent the treatment successfully, 29 were followed up for 3 to 24 months. Among them, 21 (72.4%) maintained clinical remission and the AVFs were functional, 6 patients (20.7%) got a restenosis later, and 2 patients died. Conclusions BAP is effective and safe for venous hypertension associated with AVF. However, the follow-up of patients has displayed the possible risk of restenosis in long-term outcomes.
目的探讨为维持性血液透析患者行肘部动静脉内瘘的手术方法及技巧。 方法回顾性分析我院2009年8月至2012年8月期间行肘部动静脉内瘘68例患者的临床资料。 结果68例患者手术均成功。所有患者术后血流量都能满足血液透析需要,无感染、皮下血肿等并发症。随访至今,未发现血管内血栓形成、造瘘口狭窄等。 结论对于腕部自体动静脉不能行造瘘术时,肘部动静脉内瘘为血液透析患者提供了一条新的血管通路。