Coronary angiography (CAG) as a typical imaging modality for the diagnosis of coronary diseases hasbeen widely employed in clinical practices. For CAG-based computer-aided diagnosis systems, accurate vessel segmentation plays a fundamental role. However, patients with bradycardia usually have a pacemaker which frequently interferes the vessel segmentation. In this case, the segmentation of vessels will be hard. To mitigate interferences of pacemakers and then extract main vessels more effectively in CAG images, we propose an approach. At first, a pseudo CAG (pCAG) image is generated through a part of a CAG sequence, in which the pacemaker exists. Then, a local feature descriptor is employed to register the relative location of pacemaker between the pCAG image and the target CAG image. Finally, combining the registration result and segmentation results of main vessels and pacemaker, interferences of pacemaker are removed and the segmentation of main vessels is improved. The proposed method is evaluated based on 11 CAG images with pacemakers acquired in clinical practices. An optimization ratio of the Dice coefficient is 12.04%, which demonstrates that our method can remove overlapping pacemakers and achieve the improvement of main vessel segmentation in CAG images.Our method can further become a helpful component in a CAG-based computer-aided diagnosis system, improving its diagnosis accuracy and efficiency.
摘要:目的:评价64层螺旋CT对冠心病的诊断价值。方法:对25例典型病例的CT图片进行分析、总结,观察64层螺旋CT对冠状动脉的管腔狭窄程度及冠脉内斑块性质的显示能力,并对桥血管和支架通畅性进行观察。结果:近端冠脉中度以上狭窄的敏感度、准确度、阳性预测值分别为93.5%,90.3%,88.5%,对左主干及前降支病变诊断价值较高;对冠状动脉内软斑块显示较佳;对桥血管及支架通畅和有无再狭窄显示良好。结论:MSCT冠状动脉成像在冠心病筛查及冠状动脉支架术后和搭桥术后的随访发挥重要作用。Abstract: Objective: To study the diagnose value of 64slice spiral CT for coronary heart disease. Methods:The CT pictures of 25 typical cases of coronary heart disease were analyzed so as to survey the displaying ability coronal arterial stenosis, its degree and the character plaques, the patency of bypass graft and stents by 64slice spiral CT. Results:The sensitivity, accuracy, positive predictive value for RCA1 narrow above moderate was 93.5%, 90.3%, 88.5% respectively. For LM and LAD, its diagnose value was high. The coronary soft or fibrous plaque, stent and bypass graft were displayed well. Conclusion:MSCT plays an important role in filtering coronary heart disease and reexamination after stents and bypass.
Objective To explore the correlation between hematocrit and slow coronary flow (SCF) in male patients. Methods We studied 205 patients with angiographically no more than one stenosis lt;40% in each major coronary artery who had admitted to the department of cardiology of the Beijing Anzhen Hospital Affiliated to Capital Medical University from August 2011 to August 2012. According to the level of hematocrit, 101 patients were classified into the trial group whose hematocrit was more 42.9%, while 104 patients into the control group whose hematocrit was no more than 42.9%. Clinical variables were analyzed and compared between the two groups. Results The age was younger in the trial group than the control group, whereas the levels of white blood cell count, mean platelet volume, triglyceride, low-density lipoprotein cholesterol, left anterior descending artery (LAD) and right coronary artery (RCA) TIMI frame count and the proportion of SCF in the LAD were higher in the trial group than in the control group (Plt;0.05). The results of correlation analysis showed that, LAD TIMI frame count (r=0.238, P=0.001), proportion of SCF in the LAD (r=0.206, P=0.003) and RCA TIMI frame count (r=0.209, P=0.003) were positively correlated with hematocrit. The results of multivariate analysis (using logistic regression with adjusted confounding factors such as age) showed that, LAD TIMI frame count (OR=1.031, 95%CI 1.006 to 1.056, P=0.014), proportion of SCF in the LAD (OR=1.919, 95%CI 1.038 to 3.547, P=0.038) were independently correlated with hematocrit. Conclusion The proportion of SCF in the LAD is independently correlated to hematocrit, which suggested that increased hematocrit may contribute to the pathophysiological change of SCF in male patients.
目的:了解有症状冠状动脉异常患者的临床特点和预后。方法:搜集1999年11月~2005年10月期间,因胸痛在心导管室行冠状动脉造影的病例,分析冠状动脉异常患者所占构成比,对该类患者进行随访,分析其临床特点及临床终点事件(死亡、心脏猝死、心肌梗死以及血运重建等)的发生情况。结果:在研究期间,共2003例胸痛患者进行了冠状动脉造影,74例患者有冠状动脉异常(构成比3.7%),包括心肌桥54例、冠状动脉瘘16例、冠状动脉异常起源3例、单支冠状动脉1例。其中23名冠状动脉异常患者伴发有严重的冠状动脉粥样硬化病变或主动脉瓣病变。对无上述伴发疾病的冠状动脉异常患者进行随访,在随访期内(平均随访40月),与冠状动脉正常患者相比,该类患者临床终点事件发生率无差异。结论:在有胸痛症状行冠状动脉造影的患者中,冠状动脉异常的构成比较低。该类患者的临床预后近似于冠状动脉正常患者。
目的:探讨彩色多普勒超声在诊断冠状动脉造影术后引发的医源损伤性假性动脉瘤的临床价值。方法: 经股动脉穿刺,行冠状动脉造影术而发生的股动脉假性动脉瘤共39例,所有患者都采用高频彩色多普勒诊断仪,对动脉瘤的二维超声图像、彩色多普勒图像及脉冲多普勒图像进行分析。结果: 39例假性动脉瘤患者在穿刺部位动脉的一侧均显示一搏动性无回声区或混合性低回声区;彩色多普勒显示无回声区内呈涡流或旋转样血流信号,表现为一半红色一半蓝色;脉冲多普勒显示典型的双期双向频谱。39例假性动脉瘤彩色多普勒超声诊断完全明确。其中32例在彩色多普勒超声监控下行人工加压包扎修复。7例经血管外科手术修补治疗。结论: 彩色多普勒超声在诊断冠状动脉造影术后造成的医源损伤性假性动脉瘤,在观察动脉瘤的大小、形态、瘤体的结构,判断来源动脉破口定位上准确、简便、无创,且可在超声引导下行安全无创治疗,可作为该病诊断及治疗的首选方法。
Abstract: Objective To evaluate the diagnostic accuracy for the the assessment of coronary artery stenosesusing 64-multislice spiral computed tomography (64-MSCT) scanner compared with selective coronary angiography(SCA). Methods 64-MSCT and SCA were both performed in 93 patients with 74 males and 19 females at mean age of (58.2±8.5) years in West China Hospital between April 2004 and December 2010. The cardiacrhythm of all the patients was stably sinus. Patients with initial heart rates≥90 time/min were received treatments of β-blockers. All available coronary segments(internal diameter ≥ 2.0 mm)were included in the evaluation. Lesions with ≥ 50% luminalnarrowing were considered as significant stenosis. According to the image detail of segments and existance of artfacts,the image quality was randed Ⅰ to Ⅳ ,with rank Ⅰ to Ⅲ meeting demands of image evaluation. Evaluations had been done concerning the 64-MSCT scanner for detecting the stenosis of the variant branches or segments of the coronary artery. Results 64-MSCTprovided a full image correspondence(100%,1 238/1 238)of all the segments clearly displayed in the SCA. All of the coronary segments involved (n=1 238) met the quality demands of being evaluated as rankⅠ to Ⅲ. Considering SCA as the golden standard, overall sensitivity for classifying stenosis using 64-MSCT scannerwas 88.8%(427/481), specificity was 91.7%(694/757), positive predictive value was 87.1%(427/490),and negative predictive value was 92.8%( 694/748).While the stenosis diagnostic accuracy of proximal left circumflexbranch and the first obtuse marginal branch of left coronay artery is lower than other branches: the sensitivity of the proximal left circumflex branch was 68.3%(41/60),specificity was 60.6%(20/33),positive predictive value was 75.9%(41/54),negative predictive value was 51.3%(20/39);the sensitivity of the first obtuse marginalbranch was 58.8%(10/17),specificity was 93.5%(58/62),positive predictive value was 71.4%(10/14),negative predictive value was 89.2%(58/65). Arterial wall calcification and false image of cardiac movements were the maininfluence factors for accuracy of the the assessment of coronary artery stenosis with 64-MSCT scanner. Conclusion 64-MSCT scanner provids a high diagnostic accuracy in assessing stenosis of the coronary artery. The anatomical location and luminal area of coronary artery were the main influence factors of diagnostic accuracy. Thus the diagnostic accuracy in proximal left circumflex branch and the first obtuse marginal branch of left coronary artery was lower than other coronarysegments.
ObjectiveTo explore whether preoperative coronary angiography could increase the incidence of postoperative acute kidney injury for patients with valve replacement. MethodsA total of 638 patients underwent routine cardiac valve replacement in our hospital from January 2013 through September 2015. There were 118 patients with preoperative coronary angiography (a coronary angiography group), and 520 patients without coronary angiography (a non-coronary angiography group). Serum creatinine (Scr), urea nitrogen(Bun), brain natriuretic peptide (BNP), creatine kinase myocardial band (CK-MB), cardiac troponin I (cTnI) values were recorded at 4 time points:before surgery (T0), after surgery 12 h (T1), 24 h (T2), 48 h (T3). The number of patients with acute kidney injury at the time of 48 hours after surgery was recorded. ResultsScr values (91.6±37.7 μmol/L vs. 81.0±27.4 μmol/L, 84.9±23.6 μmol/L vs. 73.5±25.3 μmol/L) increased in the patients who did not undergo coronary angiography at the time of 24 hours and 48 hours after cardiac surgery compared with the patients with coronary angiography with statistical differences. While there was no statistical difference in the incidence of acute kidney injury between the two groups. The cardiac enzymes had no statistical difference between the two groups. ConclusionPreoperative coronary angiography does not increase the probability of postoperative acute kidney injury.
目的:通过对64排螺旋CT(MSCT)冠状动脉造影与选择性冠状动脉造影检测冠状动脉病变(冠状动脉狭窄≥50%)的对比分析,探讨64层螺旋CT评估冠状动脉病变诊断的准确性。方法:回顾性收集2007年12月~2008年10月于我院同期接受64层螺旋CT冠状动脉成像和常规经皮冠脉造影的112位冠心病患者的影像资料,以常规冠脉造影为参考标准,对2种检查方法的结果进行对比分析,评估64层螺旋CT冠脉造影对冠状动脉病变诊断的准确性。结果:按常规冠脉造影计算,112例患者共发现374处病变用于评价,MSCT造影检测冠脉病变总的准确性为906%,假阳性率和假阴性率分别为43%和51%;其中MSCT检测为假阴性均发生在左回旋支和右冠远段,假阳性均为冠状动脉伴有钙化。结论:64排螺CT冠状动脉造影检测冠状动脉病变诊断的准确性较高,但血管解剖和冠状动脉钙化可能会影响其对冠状动脉病变的评价和检测。
ObjectiveTo investigate the safety and effectiveness of the multi-artery graf tstrategy for coronary bypass (MICS-CABG) with small incision in the left chest, and to provide experience for the promotion of this technique.MethodsThe clinical data of 64 patients with MICS-CABG in Department of Cardiac Surgery of Peking University Third Hospital from December 2015 to November 2019 were retrospectively analyzed. There were 54 males and 10 females, aged 36-77 (61.1±8.7) years. The left lateral thoracic incision (5-8 cm) was made through the 5th intercostal incision, and the operation was performed under off-pump CABG. With the help of the chest wall suspension device and the heart fixator, the proximal anastomosis of the ascending aorta, anastomosis of the target vessels of the left anterior descending (LAD), left circumflex (LCX) and right coronary artery (RCA) systems were completed. The number of grafts was 2-4 (2.3±0.5) including 2 grafts in 45 patients, 3 grafts in 17 patients and 4 grafts in 2 patients. Three patients were treated with percutaneous intervention (PCI) hybridization and 62 patients were treated with total artery bypass graft. Coronary angiography was performed within 7 days after the operation to evaluate the graft patency rate. The incidence of major adverse cardiac and cerebrovascular events (MACCE) was recorded in the follow-up. The MACCE rate was calculated by Kaplan-Meier method.ResultsNone of the patients was transferred to thoracotomy and no intra-aortic balloon counterpulsation (IABP) or extracorporeal membrane oxygenation (ECMO) was used during the operation. Incision infection was in 1 patient and reoperation in 2 patients (all were postoperative hemorrhage). Within 30 days after surgery, MACCE occurred in 1 patient, including 1 patient of non-fatal myocardial infarction. The overall patency rate of angiography bypass was 96.2%, and the patency rate of anterior descending branch bypass was 98.2%. Follow-up was performed from 12 to 60 months (median follow-up time was 28 months). The loss rate was 7.8% (5/64). The incidence of MACCE was 84.9% (95%CI 79.5%-90.3%).ConclusionThe MICS-CABG can achieve completed re-vascularization and totally artery-CABG and the short-term and medium-term clinical results of the operation are good.