west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "机器人" 298 results
  • Meta-analysis of leg length discrepancy after robot-assisted and traditional total hip arthroplasty

    Objective To systematically evaluate the difference in leg length discrepancy (LLD) between robot-assisted total hip arthroplasty (THA) and traditional THA. Methods The Cochrane Library, PubMed, Web of Science, EMbase, CNKI, Wanfang, VIP, and CBM databases were searched by computer to collect cohort studies of robot-assisted and traditional THAs from inception to August 11th, 2021. Two researchers independently screened the literature, extracted the data, and evaluated the risk of bias of the included studies. Meta-analysis was performed using RevMan 5.3 software. ResultsA total of 10 high-quality cohort studies were included. The results of Meta-analysis showed that compared with traditional THA, LLD after robot-assisted THA was smaller [MD=−1.64, 95%CI (−2.25, −1.04), P<0.001], Harris scores at 3 and 12 months after operation were higher [MD=1.50, 95%CI (0.44, 2.57), P=0.006; MD=7.60, 95%CI (2.51, 12.68), P=0.003]. However, the operative time was longer [MD=8.36, 95%CI (4.56, 12.17), P<0.000 1], and the postoperative acetabular anteversion angle was larger [MD=1.91, 95%CI (1.43, 2.40), P<0.001]. There was no significant difference in Harris score at 6 months, amnesia index (Forgotten joint score, FJS), postoperative acetabular abduction angle, and incidence of complication between the two groups (P>0.05). Conclusion Robot-assisted THA is superior to traditional THA in postoperative LLD.

    Release date:2022-06-08 10:32 Export PDF Favorites Scan
  • Da Vinci robot assisted choledochal cyst resection in children: experience sharing of 200 cases in a single center

    ObjectiveTo explore the clinical efficacy and share the experience of Da Vinci robot assisted choledochal cyst resection in children. MethodThe data of children including preoperative, intraoperative, and postoperative details who underwent Da Vinci robot assisted choledochal cyst resection in the Department of Pediatric Surgery, West China Hospital of Sichuan University from April 2018 to June 2022 were collected and analyzed. ResultsA total of 200 patients were collected in this study, 54 of whom were males and 146 were females. The male to female was 1∶2.70. The age was (46±33) months and the body weight was (15.77±7.10) kg. The main symptoms were abdominal pain (136 cases, 68.0%), jaundice (62 cases, 31.0%), abdominal distension (20 cases, 10.0%), and abdominal mass (23 cases, 11.5%). The diameter of cyst was (3.46±2.01) cm. There were 153 cases of type Ⅰa, 35 cases of type Ⅰc, 1 case of type Ⅱ, and 11 cases of type Ⅳ. The operation time was (179.9±10.3) min, the intraoperative fluid infusion was (397.4±26.4) mL, the intraoperative blood loss was (21.5±10.9) mL, the liquid intake time was (3.01±0.35) d, the solid intake time was (3.80±0.27) d, and the postoperative hospitalization time was (7.44±0.94) d. The intraoperative blood transfusion was performed in 4 cases (2.0%). There were 7 cases (3.5%) of postoperative complications, including 2 cases of biliary leakage, 2 cases of incomplete intestinal obstruction, and 1 case of anastomotic bleeding, which were improved by conservative treatment. Anastomotic stenosis occurred in 1 case, and the Roux-en-Y anastomosis was performed again. Biliary loop torsion obstruction occured in 1 case, which received reoperation restoring the biliary loop and closing the mesangial fissure. ConclusionsFrom the results of this study, Da Vinci robotic surgical system can obviously reduce the difficulty of choledochal cyst resection in children. It has the advantages of safe, beautiful incision, clear exposure, rapid recovery, and less complications.

    Release date:2023-02-24 05:15 Export PDF Favorites Scan
  • The learning curve and operator's perception of pulmonary lobectomy with the da Vinci robot versus the domestic robot: A retrospective cohort study

    ObjectiveTo compare the differences in the learning curve and surgeon's perception for pulmonary lobectomy performed by a single surgeon using the da Vinci surgical robot versus a domestically-made robotic system. Methods A retrospective analysis was conducted on the clinical data of the first 70 consecutive patients who underwent lobectomy with the da Vinci robot and the first 70 with a domestic robot. All procedures were performed by a single thoracic surgeon at Gansu Provincial Hospital who initiated the use of both systems concurrently between 2021 and 2024. Data were analyzed using SPSS 26.0, and learning curves for both groups were plotted and analyzed using the cumulative sum (CUSUM) method. Results The da Vinci group included 41 males and 29 females with a mean age of (66.0±6.83) years and the domestic robot group included 42 males and 28 females;with a mean age of (65.09±6.14) years. For the da Vinci group, the mean operative time was (196.14±29.63) min. The CUSUM learning curve was best fitted by a cubic equation (R2=0.986; CUSUM=0.012X3−1.799X2+69.149X−59.239, where X was the surgical volume), which peaked at the 26th case, delineating the learning and mastery phases. Statistically significant differences were observed between these phases in operation time, setup time, console time, intraoperative blood loss, postoperative day 1 drainage, and number of lymph nodes dissected (all P<0.01). For the domestic robot group, the mean operative time was (187.57±24.62) min. Its CUSUM learning curve also followed a cubic fit (R2=0.910; CUSUM=0.008X3−1.152X2+40.465X+91.940), peaking at the 18th case. Significant improvements between the learning and mastery phases were also found for the same surgical metrics (all P<0.05). The surgeon's perception score was significantly higher for the da Vinci system compared to the domestic system (4.21±0.88 vs. 3.29±1.02, P<0.05). ConclusionCUSUM analysis effectively distinguishes the learning and mastery phases for both systems. The learning curve for da Vinci robotic lobectomy is overcome after 26 cases, whereas the domestic robot required 18 cases. In the mastery phase, operative time, setup time, intraoperative blood loss, and postoperative day 1 drainage are significantly lower, while the number of lymph nodes dissected is significantly higher compared to the learning phase for both systems. There are no significant differences in short-term efficacy or safety between the two groups. However, the da Vinci system provids a superior surgeon experience.

    Release date: Export PDF Favorites Scan
  • Early effectiveness of robot-assisted total hip arthroplasty via direct superior approach

    ObjectiveTo evaluate the early effectiveness of the robot-assisted total hip arthroplasty (THA) via direct superior approach (DSA).MethodsBetween March 2021 and April 2021, 11 patients (11 hips) were treated with a robot-assisted THA via DSA. There were 7 males and 4 females, with an average age of 55 years (range, 26-73 years). There were 5 patients of osteoarthritis secondary to hip dysplasia and 6 patients of osteonecrosis of femoral head. Preoperative hip Harris score was 55.8±6.3. The operation time, volume of blood loss, length of incision, postoperative blood transfusion and hospital stay, and the incidence of surgical complications were recorded. The visual analogue scale (VAS) score and Harris score were used to evaluate hip joint pain and function. The leg length discrepancy (LLD) was measured on the X-ray films. The inclination angle and anteversion angle of the acetabular component were also measured, and the difference between the planned and actual values were compared.ResultsOne THA was performed via conventional posterolateral approach finally because of poor exposure. The rest of 10 THAs were performed with assistance of robotic arm via DSA. The average operation time was 89 minutes (range, 65-120 minutes); the average length of incision was 10.5 cm (range, 9-13 cm); and the average blood loss was 400 mL (range, 110-740 mL). One patient was given a blood transfusion for 2 unit. All incisions healed by first intention and no neurovascular injury, deep vein thrombosis, or fracture occurred. The length of hospital stay after operation was 2-6 days (mean, 4.4 days). The duration of follow-up was 1-3 months (mean, 2.1 months). The VAS score was 0 in 9 patients and 2 in 1 patient at the day of discharge. At last follow-up, the hip Harris score was 84.9±6.7, showing significant difference when compared with that before operation (t=−8.717, P=0.000). The inclination and anteversion angles were (37.4±2.0)° and (17.1±4.5)°, respectively, and there was no significant difference when compared with the planned values [(38.2±1.6)°, (16.6±3.7)°] (t=1.809, P=0.104; t=–1.103, P=0.299). The LLD ranged from –2 to 4 mm. No complication such as dislocation, aseptic loosening, or periprosthetic joint infection occurred. ConclusionThe robot-assisted THA via DSA has encouraged early effectiveness.

    Release date:2021-10-28 04:29 Export PDF Favorites Scan
  • Orthopedic robot based on 5G technology for remote navigation of percutaneous screw fixation in pelvic and acetabular fractures

    Objective To investigate the accuracy and safety of percutaneous screw fixation for pelvic and acetabular fractures with remote navigation of orthopedic robot based on 5G technology. Methods Between January 2021 and December 2021, 15 patients with pelvic and/or acetabular fractures were treated with percutaneous screws fixation which were placed by remote navigation of orthopedic robot based on 5G technology. There were 8 males and 7 females. The age ranged from 20 to 98 years, with an average of 52.1 years. The causes of trauma included traffic accident injury in 6 cases, falling from height injury in 6 cases, fall injury in 2 cases, and heavy object smashing injury in 1 case. The time from injury to operation ranged from 3 to 32 days, with an average of 10.9 days. There were 8 cases of simple pelvic fractures, 2 simple acetabular fractures, and 5 both pelvic and acetabular fractures. There were 7 cases of pelvic fractures of Tile type B2, 2 type B3, 1 type C1, and 3 type C2; 4 cases of unilateral anterior column fracture of the acetabulum, 2 bilateral anterior column fractures, and 1 anterior wall fracture. CT images within 5 days after operation were collected for screw position assessment. The screw planning time and guidewire placement time were recorded, as well as the presence of intraoperative adverse events and complications within 5 days after operation. Results All patients achieved satisfactory surgical results. A total of 36 percutaneous screws were inserted (20 sacroiliac screws, 6 LC Ⅱ screws, 9 anterior column screws, and 1 acetabular apical screw). In terms of screw position evaluation, 32 screws (88.89%) were excellent and 4 screws (11.11%) were good; there was no screw penetrating cortical bone. The screw planning time ranged from 4 to 15 minutes, with an average of 8.7 minutes. The guidewire placement time ranged from 3 to 10 minutes, with an average of 6.8 minutes. The communication delayed in 2 cases, but the operation progress was not affected, and no serious intraoperative adverse events occurred. No delayed vascular or nerve injury, infection, or other complications occurred within 5 days after operation. No cases need surgical revision. ConclusionThe fixation of pelvic and acetabular fractures by percutaneous screw with remote navigation of orthopedic robot based on 5G technology is accurate, safe, and reliable.

    Release date:2022-08-29 02:38 Export PDF Favorites Scan
  • Progress and prospect of robotic cardiac surgery

    Minimally invasive cardiac surgeries are the trend in the future. Among them, robotic cardiac surgery is the latest iteration with several key-hole incision, 3-dimentional visualization, and articulated instrumentation of 7 degree of ergonomic freedom for those complex procedures in the heart. In particular, robotic mitral valve surgery, as well as coronary artery bypass grafting, has evolved over the last decade and become the preferred method at certain specialized centers worldwide because of excellent results. Other cardiac procedures are in various stages of evolution. Stepwise innovation of robotic technology will continue to make robotic operations simpler, more efficient, and less invasive, which will encourage more surgeons to take up this technology and extend the benefits of robotic surgery to a larger patient population.

    Release date:2019-09-18 03:45 Export PDF Favorites Scan
  • The clinical efficacy of all-port robotic versus thoracoscopic lobectomy in stageⅠA non-small cell lung cancer: A retrospective cohort study

    ObjectiveTo investigate the perioperative efficacy and safety of all-port robotic lobectomy versus thoracoscopic lobectomy in stageⅠA non-small cell lung cancer. MethodsThe clinical data of patients with stageⅠA non-small cell lung cancer who underwent lobectomy with lymph node dissection performed by the same operator in our center from June 2019 to June 2022 were retrospectively analyzed. The patients were divided into a robotic group and a thoracoscopic group according to different procedures. We compared the relevant indexes such as operation time, intraoperative bleeding, number of lymph node dissection stations, number of lymph node dissection, postoperative tube time, postoperative hospitalization time, closed chest drainage volume, postoperative pain, postoperative complications and hospitalization cost between the two groups. ResultsThere were 83 patients in the robotic group, including 34 males and 49 females with a median age of 60.0 (53.0, 67.0) years, and 94 patients in the thoracoscopic group, including 36 males and 58 females with a median age of 60.5 (54.0, 65.3) years. There was no conversion to thoractomy or death in postoperative 90 days in both groups. No statistical difference was seen in the operation time, total postoperative drainage volume and postoperative complication rates between the two groups (P>0.05). Patients in the robotic group had less intraoperative bleeding (P<0.001), more lymph node dissection stations (P=0.002) and numbers (P=0.005), less postoperative pain (P=0.002), and shorter postoperative time with tubes (P=0.031) and hospital stay (P<0.001). However, the surgery was more expensive in the robotic group (P<0.001). ConclusionAll-port robotic surgery is safe and effective for patients with early-stage non-small cell lung cancer with less intraoperative bleeding, more lymph node dissection, less postoperative pain, and shorter hospital stay compared with the thoracoscopic surgery.

    Release date:2023-09-27 10:28 Export PDF Favorites Scan
  • Research on the influence of light with different wavelength on the motion behavior of carp robots

    In order to study the effect of light with different wavelengths on the motion behavior of carp robots, phototaxis experiment, anatomical experiment, light control experiment and speed measurement experiment were carried out in this study. Blue, green, yellow and red light with different wavelength were used to conduct phototaxis experiments on carp to observe their movement behavior. By dissecting the skull bones of the carp to determine the appropriate location to carry the light control device, we independently developed a light control carrying device which was suitable for any illumination intensity environment. The experiment of the light-controlled carp robots was carried out. The motion behavior of the carp robot was checked by using computer binocular stereo vision technology. The motion trajectory of the carp robot was tracked and obtained by applying kernel correlation filter (KCF) algorithm. The motion velocity of the carp robot at different wavelengths was calculated according to their motion trajectory. The results showed that carps’ sensitivity to different light changed from strong to weak in the order of blue, red, yellow and green, so that using light with different wavelengths to control the speed of the carp robot has certain laws to follow. A new method to avoid brain damage in carp robots control can be provided in this study.

    Release date:2021-10-22 02:07 Export PDF Favorites Scan
  • Retrospective analysis of mediastinal mass resection with totally no tube during da Vinci robotic surgery for 79 patients

    Objective To analyze the feasibility of totally no tube (TNT) in da Vinci robotic mediastinal mass surgery and its significance for fast track surgery. Methods A total of 79 patients receiving robotic mediastinal TNT surgery in the General Hospital of Shenyang Military Command from January 2016 to December 2017 were enrolled as a TNT group; 35 patients receiving robotic mediastinal surgery in General Hospital of Shenyang Military Command from January 2014 to December 2017 and 54 patients receiving thoracoscopic mediastinal surgery during the same period were enrolled as a non-TNT group and a video-assisted thoracoscopic surgery (VATS) group. The muscle relaxation and tracheal intubation/laryngeal masking time, operation time, intraoperative blood loss, postoperative ICU stay, postoperative hospital stay, postoperative visual analogue scale (VAS), hospitalization costs and postoperative complications and other related indicators were retrospectively analyzed among the three groups. Results Surgeries were successfully completed in 168 patients with no transfer to thoracotomy, serious complications (postoperative complications in 9 patients) or death during the perioperative period. All patients were discharged. Compared with the non-TNT group, the TNT group had significantly less muscle relaxation-tracheal intubation/laryngeal masking time, operation time, intraoperative blood loss, VAS pain score, ICU stay, postoperative hospital stay (P<0.01); there was no significant difference in the total cost of hospitalization between the two groups (P>0.05). Between the non-TNT group and the VATS group, there was no significant difference in time of muscle relaxation and tracheal intubation, operation time and ICU stay (P>0.05). The non-TNT group was superior to the VATS group in terms of intraoperative blood loss, VAS pain scores on the following day after operation, chest drainage volume 1-3 days postoperatively, postoperative catheterization time and postoperative hospital stay (P<0.05); but the cost of hospitalization in the non-TNT group was significantly higher (P=0.000). Conclusion The da Vinci robot is safe and feasible for the treatment of mediastinal masses. At the same time, TNT is also safe and reliable on the basis of robotic surgery which has many advantages such as better comfort, less pain, ICU stay and hospital stay as well as faster recovery.

    Release date:2019-03-01 05:23 Export PDF Favorites Scan
  • Research and application of photovoltaic cell online monitoring system for animal robot stimulator

    Power supply plays a key role in ensuring animal robots to obtain effective stimulation. To extending the stimulating time, there is a need to apply photovoltaic cells and monitor their parameter variations, which can help operators to obtain the optimal stimulation strategy. In this paper, an online monitoring system of photovoltaic cells for animal robot stimulators was presented. It was composed of battery information sampling circuit, multi-channel neural signal generator, power module and human-computer interaction interface. When the signal generator was working, remote navigation control of animal robot could be achieved, and the battery voltage, current, temperature and electricity information was collected through the battery information sampling circuit and displayed on the human-computer interaction system in real time. If there was any abnormal status, alarm would be activated. The battery parameters were obtained by charging and discharging test. The battery life under different light intensity and the stimulation effect of neural signal generator were tested. Results showed that the sampling errors of battery voltage, current and electric quantity were less than 15 mV, 5 mA and 6 mAh, respectively. Compared with the system without photovoltaic cells, the battery life was extended by 148% at the light intensity of 78 320 lx, solving the battery life problem to some extent. When animal robot was stimulated with this system, left and right turns could be controlled to complete with the success rate more than 80%. It will help researchers to optimize animal robot control strategies through the parameters obtained in this system.

    Release date:2022-12-28 01:34 Export PDF Favorites Scan
30 pages Previous 1 2 3 ... 30 Next

Format

Content