west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "桡骨远端" 35 results
  • External Fixator or Locking Compression Plate for the Treatment of Die-punch Fractures in Distal End of Radius

    目的 比较外固定支架与锁定加压钢板(LCP)治疗桡骨远端die-punch骨折的疗效及适应证。 方法 2007年1月-2011年1月,分别采用外固定支架和LCP治疗桡骨远端die-punch骨折32例36侧,其中LCP固定19侧,外固定支架固定17侧。两组患者性别、年龄、致伤原因、骨折分类、伤后至入院时间等一般资料比较差异无统计学意义(P>0.05)。术中对塌陷的关节面均采取撬拨植骨的方法恢复桡腕关节,克氏针固定较大骨折块。比较两种方法手术前后掌倾角、尺偏角、桡腕关节面恢复情况、骨折愈合时间,术后腕关节活动范围等。 结果 两组患者手术切口均Ⅰ期愈合,无感染发生。患者术后均获随访,随访时间6~24个月,平均13个月。所有患者骨折愈合良好,愈合时间、术后6个月X线片掌倾角、尺偏角两组间差异均无统计学意义(P>0.05);术后6个月腕关节尺偏活动度分别为(20.8 ± 3.6)°和(18.0 ± 2.8)°,LCP组优于外固定支架组(P<0.05);LCP组和外固定支架组桡骨高度分别为(10.9 ± 2.8)mm和(13.4 ± 2.3)mm,Gartland-Werley评分分别为(5.3 ± 2.4)分和(8.4 ± 3.6)分,两组差异有统计学意义(P<0.05)。 结论 对于桡骨远端die-punch骨折,LCP可提供有效固定及早期活动,但对于关节面的塌陷及桡骨高度的恢复,外固定支架固定可提供良好的支撑作用。对于严重die-punch骨折可联合运用LCP和外固定支架等技术。

    Release date:2016-09-08 09:17 Export PDF Favorites Scan
  • 桡骨远端骨折合并腕部尺神经损伤六例分析

    目的 总结桡骨远端骨折合并尺神经损伤的临床特点、治疗方法及预后。 方法 分析2002 年8 月- 2008 年8 月收治的6 例合并尺神经损伤的桡骨远端骨折患者临床资料。男4 例,女2 例;年龄21 ~ 55 岁,平均39岁。新鲜骨折4 例,其中开放骨折1 例;陈旧性骨折2 例。骨折类型按国际内固定研究学会(AO/ASIF)分型:A3 型2 例,B2、B3、C2、C3 型各1 例。6 例均有尺神经卡压和损伤表现。受伤至治疗时间3 h ~ 3.5 个月。分别给予切开复位钢板螺钉内固定、切开复位克氏针内固定加外固定架固定、闭合复位外固定架固定治疗。 结果 术后6 例均获随访,随访时间12 ~ 24 个月,平均18 个月。按中华医学会手外科学会上肢部分功能评定试用标准评定,获优5 例,可1 例。术后X 线片显示骨折对位良好,术后4 ~ 5 个月桡骨远端骨折均骨性愈合。随访期间无内固定物松动及骨折移位等并发症发生。除1 例陈旧性骨折手内在肌萎缩、运动功能恢复不明显外,余5 例尺神经感觉、运动功能均恢复较理想,爪形手畸形消失。 结论 合并尺神经损伤的桡骨远端骨折,开放手术时应行尺神经探查减压术,如未行探查手术应密切观察其病情变化。

    Release date:2016-08-31 05:47 Export PDF Favorites Scan
  • Research progress in the treatment of distal radius fractures assisted by wrist arthroscopy

    ObjectiveTo review the research progress of wrist arthroscopy assisted treatment of distal radius fractures.MethodsTo summarize and describe the anatomical characteristics and fracture classification of the distal radius, indications and contraindications of wrist arthroscopy-assisted treatment, surgical methods, and associated soft tissue injuries, and summarize the advantages and disadvantages of the operation through a large number of literature at home and abroad on the treatment of distal radius fractures assisted by wrist arthroscopy.ResultsWrist arthroscopy as a minimally invasive technique for the treatment of distal radius fractures, compared with traditional surgery, can accurately observe intra-articular damage and perform operations under the microscope to avoid secondary damage to blood vessels, nerve, and tendon, etc., and can achieve one-stage repair and reconstruction by repairing the ligament, trigonal fibrocartilage complex, and carpal dislocation. It has the advantages of less trauma, fast postoperative recovery, extensive indications, fewer complications, and satisfactory effectiveness.ConclusionWrist arthroscopy has advantages that traditional X-ray film, CT, MRI, and arthrography examinations do not have. Moreover, wrist arthroscopy has achieved satisfactory effectiveness in the adjuvant treatment of intra-articular distal radius fractures.

    Release date:2020-11-02 06:24 Export PDF Favorites Scan
  • Effectiveness analysis of distal radius microplate locking plate for treatment of displaced fracture of medial clavicle

    ObjectiveTo investigate and evaluate the effectiveness of the distal radius microplate locking plate for the treatment of displaced fracture of medial clavicle.MethodsBetween January 2013 and June 2017, 18 cases of obvious displaced fracture of medial clavicle were treated with distal radius microlocking plate. There were 10 males and 8 females, with an average age of 51.4 years (range, 18-88 years). Causes of injury included traffic accident injury in 15 cases, heavy object injury in 3 cases; all of them were closed injury. According to Edinburgh classification, 15 cases were ⅠB1 type and 3 cases were ⅠB2 type. Fracture displacement was 12-21 mm (mean, 16.3 mm). The time from injury to operation was 3-7 days (mean, 4.3 days). After operation, the clinical healing and complications of fracture were observed, and shoulder function was evaluated according to Rockwood’s scoring criteria.ResultsNo incisional infection, neurovascular injury, or other early complications occurred. All 18 patients were followed up 8-15 months (mean, 12 months). All fractures reached clinical osseous union, and the healing time was 8-24 weeks (mean, 16.6 weeks). Postoperative plate loosening occurred in 1 case, which was removed surgically, while other patients did not suffer from complications such as bone nonunion, displacement, internal fixator loosening, and loss of reduction. At last follow-up, according to Rockwood’s scoring criteria, the results were excellent in 12 cases and good in 6 cases.ConclusionThe distal radius microplate locking plate is effective for the treatment of displaced medial clavicle fracture, which has few complications, and is feasible for early functional exercise, and is helpful for the recovery of shoulder joint function.

    Release date:2019-05-06 04:48 Export PDF Favorites Scan
  • CLINICAL EFFECTS OF LOCKING PLATE SYSTEM IN TREATING DISTAL RADIAL FRACTURES

    Objective To determine the cl inical results of locking plate system in the treatment of distal radial fractures. Methods From May 2004 to November 2006, 75 patients were treated with 2.4 mm locking plate system. There were 41 males and 34 females, with a mean age of 51 years old (range, 13-82 years old). The locations were left side in 34 casesand right side in 41 cases. The cause of injury was a low energy fall in 49 cases, fall ing from height in 14 cases, traffic accident in 6 cases and sports injuries in 6 cases. All patients were diagnosed as having closed fracture. According to Müller-AO classification, there were 14 cases(18.7%) of type A, 5 cases(6.7%) of type B, and 56 cases(74.6%) of type C. The time from injury to operation was 5 hours to 27 days (mean 6 days). Results A total of 75 patients were followed up at 3 months, 71 patients at 6 months, 68 patients at 1 year and 51 patients at 2 years. Heal ing by first intention of incision was achieved in 73 cases, and infection occurred in 2 cases. Fracture reduction failed at 1 month, 3 months and 6 months in 1 case, respectively; 1 case received plaster fixation and 2 cases received re-fixation and autograft of il ium; and fracture healed in 3 cases at last follow-up. Two patients complained of skin numbness at site of superficial branch of radial nerve after 1 day, 1 patient had wound pain after operation, and 1 patient had infection of tendon at 3 days and 5 days in 1 case respectively. At last follow-up, the ranges of motion of wrist joint were (80 ± 9)° for pronation, (86 ± 7)° for supination, (57 ± 10)° for dorsal flexion, (51 ± 13)° for palmar flexion, (18 ± 7)° for radial incl ination, and (28 ± 7)° for ulnar deviation. According to modified Green scoring, the results were excellent in 66 cases, good in 6 cases and poor in 3 cases. At last follow-up, according to Knirk criterion for osteoarthritis, there were 22 cases of grade I and 5 cases of grade II, and all were classified as type C. Conclusion Internal fixation of distal radial fractures with 2.4 mm locking plate system provided a stable fixation with good cl inical outcomes.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • Effectiveness and Safety of External Fixation versus Open Reduction and Internal Fixation for the Adults’ Unstable Distal Radius Fractures: A Systematic Review

    Objective To evaluate the effectiveness and safety of external fixation (EF) and open reduction and internal fixation (ORIF) for unstable distal radius fractures in adults. Methods We searched MEDLINE (1966 to September 2008), Cochrane Central register of controlled Trials (The Cochrane Library, Issue 3, 2008), EMbase (1974 to September 2008), CBM, CNKI, and collected randomized controlled trials (RCTs) of EF and ORIF for unstable distal radius fractures in adults. The quality of the included studies was critically assessed and data analyses were performed with the Cochrane Collaboration’s RevMan 5.0 software. Results Seven RCTs involving 634 patients were included, of which 269 were in EF group, and 293 were in ORIF group. Only 1 study had relative high quality, all the others had some limitation in randomization, blinding, and allocation concealment. The results of meta-analyses showed that, 1) about the effectiveness: according to the Gartland and Werley grade standard, the ORIF group was better than the EF group with statistic difference (RR=1.50, 95%CI 1.11 to 2.03, P=0.008); because of the original studies did not offer the detailed data including pad strength, grip strength, flexion-extension, radial deviation, and ulnar deviation, we only processed a descriptive analysis; and 2) about complications: the infection rate of the pin track was higher in the EF group than that in the ORIF group with statistic difference (RR=0.24, 95%CI 0.08 to 0.76, P=0.02); but there were no differences between the two groups in reflex sympathetic dystrophy (RSD) (RR=0.88, 95%CI 0.30 to 2.56, P=0.82), extensor tendon rupture (RR=3.93, 95%CI 0.45 to 34.62, P=0.22), and compartment syndrome (RR=3.13, 95%CI 0.51 to 19.09, P=0.22). Conclusions Compared with EF, ORIF is much better based on Gartland and Werley grade standard, and causes much less infection. Because of the limited quality and quantity of the included studies, more proofs are required from more RCTs with large sample.

    Release date:2016-09-07 11:09 Export PDF Favorites Scan
  • EFFECTIVENESS COMPARISON OF EXTERNAL FIXATION AND VOLAR LOCKING COMPRESSION PLATE IN TREATMENT OF DISTAL RADIUS FRACTURES OF TYPE C

    ObjectiveTo compare the effectiveness of external fixation and volar locking compression plate in the treatment of distal radius fractures of type C. MethodsBetween March 2012 and March 2013, 122 patients with distal radius fractures of type C were enrolled in the prospective randomized study. Fractures were treated by external fixation in 61 patients (external fixation group) and by open reduction and internal fixation using a volar locking compression plate in 61 patients (plate group). There was no significant difference in age, gender, fracture side, weight, height, body mass index, fracture type, and interval of injury and operation between 2 groups (P>0.05). The blood loss, operation time, hospitalization days, fracture union time, wrist function, and complications were compared between 2 groups. And the quality of reduction was observed, including volar tilting angle, ulnar deviation, radial height, and articular reduction. ResultsThe blood loss, operation time, and hospitalization days in plate group were significantly higher than those in external fixation group (P<0.05). All of the patients in both groups were followed up 12-28 months. Postoperative complications occurred in 4 patients (6.6%) of external fixation group (pin tract infection in 2 cases and radial nerve neuritis in 2 cases) and in 5 patients (8.2%) of plate group (wound infection in 1 case, carpal tunnel syndrome in 2 cases, and tendon rupture in 2 cases), showing no significant difference between 2 groups (P=0.500). The X-ray films showed fracture healing in all patients of 2 groups; the union time of plate group was significantly longer than that of external fixation group (P<0.05). At last follow-up, there was no significant difference in ulnar deviation and radial height between 2 groups (P>0.05), but the volar tilting angle of plate group was significantly larger than that of external fixation group (P<0.05). There was no significant difference in wrist function and articular reduction between 2 groups (P>0.05). ConclusionFor distal radius fractures of type C, the use of external fixation or volar locking compression plate can obtain satisfactory clinical outcomes, but the external fixation has the advantages of less invasion, shorter hospitalization days, minor complications, and faster fracture union.

    Release date: Export PDF Favorites Scan
  • TREATMENT OF INTRA-ARTICULAR FRACTURE OF DISTAL RADIUS WITH T-SHAPED PLATE INTERNAL FIXATION.

    Objective To evaluate the effects of T-shaped plate internal fixation in treatment of intra-articular fracture of distal radius. Methods From January 2005 to March 2008, 52 cases of intra-articular fracture of distal radius were treated, including 32 males and 20 females and aging 21-60 years old (mean 47 years old). Fracture was caused by tumbl ing in 30 cases, by fall ing from height in 8 cases, by traffic accident in 11 cases, and by a crashing object in 3 cases. Of 52 cases,there were 50 cases of closed fracture and 2 cases of open fracture. According to AO standard of classification, there were 14 cases of B2 type, 16 cases of B3 type, 15 cases of C1 type, 6 cases of C2 type, and 1 case of C3 type. According to the Cooney’ s general standard of classification of unstable fracture, there were 5 cases of type II, 10 cases of type III, and 37 cases of type IV. The time from injury to operation was 3-14 days (mean 5 days). All patitents received open reduction and T-shaped plate fixation. Seven patients having bone defect were given 6-15 g autologous il ium or 5 mL calcium sulphate artificial aggregate after reduction. Results All incisions healed by first intention. All the patients were followed up for 15 to 30 months postoperatively (mean 24 months). The X-ray films showed good anatomical reduction, even articular surface and no lossening of internal fixation in all the cases. The fractures healed within 9-15 weeks after operation (mean 12 weeks). At last follow-up, the mean palmar tilt was 8° and the mean ulnar variance was 21°, showing statistically significant differences when compared preoperation (— 5° and 5°, P lt; 0.05). The radial length were not abbreviated. According to Dienst assessment, the results were excellent in 42 cases, good in 3 cases, fair in 5 cases and poor in 2 cases 12 weeks after operation, and the excellent and good rate was 86.5%. Conclusion T-shaped plate fixation is rel iable and effective in treatment of intra-articular fracture of distal radius because it has less coml ication of infection, loosening of internal fixation, reduction failure and tendon rupture.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • Effectiveness comparison between minimally invasive surgery and traditional open reduction internal fixation in treatment of unstable distal radial fractures

    ObjectiveTo compare the effectiveness of minimally invasive percutaneous internal fixation and traditional open reduction via Henry approach and internal fixation in the treatment of unstable distal radial fractures.MethodsFifty-six patients with unstable distal radial fractures that met the selection criteria between October 2013 and December 2014 were randomly divided into minimally invasive group (26 cases) and traditional group (30 cases). They were treated with oblique T-shaped locking plate internal fixation via minimally invasive percutaneous approach or traditional Henry approach. There was no significant difference in gender, age, side, causes of injury, fracture classification, and time from injury to operation between 2 groups (P>0.05). The length of incision, operation time, intraoperative blood loss, hospitalization time, and fracture healing time were recorded in 2 groups. The difference of the length of the radial styloid process, the volar tilting angle, and the ulnar inclining angle between at 3 months postoperatively and preoperation were compared between 2 groups. The visual analogue scale (VAS) score, the percentage of the lateral wrist flexion and extension range, forearm rotation, and the hand grip strength (recorded as FS%, FR%, and HG% , respectively) were compared between 2 groups at 4 weeks and 3 months postoperatively. The wrist function was evaluated through the disability of arm-shoulder-hand (DASH) scores at 3 months postoperatively.ResultsThe length of incision, operation time, intraoperative blood loss, and hospitalization time in minimally invasive group were significantly less than those in traditional group (P<0.05). The incisions of 2 groups were all achieved primary healing. All patients were followed up 10-16 months (mean, 12.6 months). There was no radial artery injury, screw too long, or screw entering the joint space. In minimally invasive group, 1 patient had the symptoms of median nerve irritation after operation, and recovered completely at 1 month; in traditional group, there were 2 cases of tendon irritation after operation. There was no significant difference in the fracture healing time, the difference of the length of the radial styloid process, the volar tilting angle, and the ulnar inclining angle between at 3 months postoperatively and preoperation between 2 groups (P>0.05). At 4 weeks after operation, the VAS score in minimally invasive group was significantly less than that in traditional group, and the FS%, FR%, and HG% were significantly higher than those in traditional group (P<0.05). There was no significant difference in above indicators between 2 groups at 3 months after operation (P>0.05). The DASH score in minimally invasive group was significantly less than that in traditional group at 3 months after operation (t=–5.308, P=0.000). The patient’s aesthetic evaluation of postoperative wound in minimally invasive group was better than in traditional group.ConclusionFor treatment of unstable distal radial fractures, the metacarpal minimally invasive internal fixation has the advantages of smaller wound, incisional concealment, and quicker recovery of wrist joint.

    Release date:2018-03-07 04:35 Export PDF Favorites Scan
  • Surgical techniques and effectiveness of volar locking plates for senile delayed distal radius fractures

    Objective To investigate the surgical technique and effectiveness of volar locking plates for senile delayed distal radius fractures. Methods Between October 2014 and September 2015, 25 cases of delayed distal radius fractures were treated by volar locking plates. There were 3 males and 22 females with an average age of 73 years (range, 65-87 years). Injury was caused by tumble in 19 cases and by traffic accident in 6 cases. All the cases had closed fracture. According to the AO classification, 10 cases were rated as type A2, 7 cases as type A3, 3 cases as type B3, and 5 cases as type C1. The manual reduction and plaster immobilization were performed in 18 cases first, but reduction failed; no treatment was given in 7 cases before surgery. The time from injury to surgery was from 33 to 126 days (mean, 61 days). Preoperatively, the volar tilting angle was (–16.0±3.1)°; the ulnar inclining angle was (10.8±7.0)°; the radial shortening was (11.2±3.6) mm; the wrist range of motion was (41.0±7.5)° in flexion and was (42.0±6.3)° in extension; and the grip strength was 33.0%±3.1% of normal side. Results All incisions healed primarily, and no postoperative complication occurred. The patients were followed up 1-1.5 years (mean, 1.3 years). The X-ray films showed that fracture union was achieved in all the patients, with the mean healing time of 9.2 weeks (range, 8-12 weeks); the displacement of the articular surface was less than 1 mm. At last follow-up, the volar tilting angle was (13.1±3.2)°; the ulnar inclining angle was (21.9±4.6)°; the radial shortening was (2.0±1.1) mm; the wrist range of motion was (52.0±11.7)° in flexion and was (65.0±4.8)° in extension; and the grip strength was 84.0%±4.2% of normal side; all showed significant difference when compared with preoperative ones (P<0.05). According to the Gartland and Werley score, the results were excellent in 15 cases, good in 6 cases, fair in 2 cases, and poor in 2 cases at last follow-up; the excellent and good rate was 84%. Conclusion By the good design of the volar locking plate and the command of surgical techniques, good effectiveness can be achieved in the treatment of senile delayed distal radius fracture.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content