【Abstract】 Objective To evaluate the effectiveness of percutaneous fixation of pelvic fracture by Acutrak full thread headless hollow compression screw. Methods Between March 2008 and April 2010, 31 patients with pelvic fracture underwent percutaneous fixation surgery with Acutrak full thread headless hollow compression screw (surgical group). The effectivenss was compared with those of 14 patients with pelvic fracture treated conservatively (control group). There was no significant difference in age and sex between 2 groups (P gt; 0.05). The injury was more severe in surgical group than in control group. The standard of short-term recovery was active turning over and walking for 5 steps with walking aids. The standard of long-term recovery was pain, gait, fracture healing, and function recovery. Results In surgical group, the other patients reached the standard of short-term recovery at 1-4 days after injury except 1 patient who had sacral plexus injury; in control group, the patients could turn over at 9-13 days (Tile type A2) and 17-25 days (Tile type B2) respectively, and could walk at 17-21 days (Tile type A2) and at 45-57 days (Tile type B2) respectively. The patients of 2 groups were followed up 6-19 months. The time of fracture healing was 2-6 months. The long-term results were excellent in 29 cases and good in 2 cases in surgical group, and were excellent in 8 cases and good in 6 cases in control group, showing significant difference between 2 groups (χ2=6.636, P=0.017).Conclusion Percutaneous internal fixation combined with Acutrak full thread headless hollow compression screw can provide more effective treatment. It can alleviate patients, pain quickly, improve life quality, and has better long-term effectiveness.
ObjectiveTo discuss the effectiveness of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture in adolescents by using double heads compressive cannulated screw fixation.MethodsTwenty-four patients with ACL tibial eminence avulsion fractures were treated by arthroscopic reduction and internal fixation with double heads compressive cannulated screw fixation between June 2014 and June 2017. There were 15 males and 9 females with an average age of 12.3 years (range, 5-18 years). The body mass index was 19.3-26.4 kg/m2 (mean, 23.3 kg/m2). The injury causes included traffic accident injury in 10 cases, sports injury in 8 cases, and falling injury in 6 cases. According to the Meyers-McKeever classification, there were 19 cases of type Ⅱ and 5 cases of type Ⅲa. All patients’ drawer test and pivot shift test were positive. The interval between injury and operation was 3-14 days (mean, 6.2 days). During the follow-up period, the fracture healing condition of patients were determined by X-ray examination; Lysholm score, International Knee literature Committee (IKDC) score, and Tegner score were used to evaluate the knee function.ResultsPrimary healing of incision was obtained in all patients after operation. All the 24 patients were followed up 6-32 months (mean, 16.4 months). At 6 weeks after operation, 3 patients had difficulty in knee flexion. After the release of the knee joint by manipulation, the knee joint function recovered normally at 6 months after operation. At last follow-up, the X-ray films showed that all the fractures healed and no epiphyseal dysplasia, knee joint deformity, or leg length discrepancy occurred. The Lysholm score, IKDC score, and Tegner score were improved from preoperative 44.3±5.4, 43.7±4.4, and 3.0±1.3 to postoperative 93.1±4.3, 94.6±3.3, and 8.1±1.2, the differences were all significant (t=25.152, P=0.000; t=28.634, P=0.000; t=13.226, P=0.000).ConclusionThe arthroscopic reduction and internal fixation with double heads compressive cannulated screw in treatment of ACL tibial avulsion fracture (Meyers-McKeever type Ⅱ and Ⅲ) in adolescents has so many advantages, such as minimal trauma, simple operation, firm fixation, little effect on the epiphyseal plate, and has a good joint function recovery.
Objective To evaluate the internal fixation effect, degradation, and biocompatibility of polylactic-co-glycolic acid/hydroxyapatite (PLGA/HA) absorbable cannulated screws in treatment of lateral femoral condyle fracture of canine so as to provide the theory basis for their further improvement and clinical application. Methods Sixteen adult male Beagles (weighing, 9-12 kg) were selected to prepare the models of bilateral lateral femoral condyle fracture; left fracture was fixed with PLGA/HA absorbable cannulated screws as experimental group and right fracture with metal screws as control group. At 2, 4, 8, and 12 weeks after operation, general observation was done and X-ray films were taken for observing fracture healing; bone mineral density was measured; the histological examination was performed; and the degradation property of absorbable cannulated screws was detected. Results All animals survived to the end of the experiment. General observations showed that no fracture displacement occurred and fracture healed at 12 weeks in 2 groups; no breakage, displacement, or loosening of screws was observed in experimental group. X-ray films results showed that the absorbable cannulated screws could not be found out by X-ray in experimental group, but metal screws could be found out in control group; fracture healed with time in 2 groups. The bone mineral density reached the peak at 8 weeks in 2 groups, and no significant difference was found between 2 groups and among different time points in the same group (P gt; 0.05). Histological examination showed that 2 groups had similar fracture healing process at different time points; no obvious inflammatory reaction was found around absorbable cannulated screws in experimental group. The degradation results of absorbable cannulated screws showed that the intrinsic viscosity and molecular weight distribution obviously decreased at 2 weeks; the number average molecular weight and the weight average molecular weight markedly decreased at 4 weeks; and the maximum shear force did not decrease obviously at 8 weeks, and then decreased significantly. Significant differences were found in all indexes among different time points in the same group (P lt; 0.05). Conclusion PLGA/HA absorbable cannulated screws and metal screws show similar fracture healing process for fixing lateral femoral condyle fracture of canine, and the absorbable canulated screws have good biocompatibility. The maximum shear force of PLGA/HA absorbable cannulated screw has no obvious decrease during 8 weeks after operation, so it can ensure full healing of fracture.
Objective To investigate the clinical efficacy of computer-assisted cannulated screw internal fixation system based on error correction method for femoral neck fractures. Methods A retrospective analysis was made on the clinical data of 20 femoral neck fracture patients treated by computer-assisted cannulated screw internal fixation system based on error correction method between January 2014 and October 2015 (trial group), and 36 femoral neck fracture patients undergoing traditional manual surgery with closed reduction by cannulated screw fixation in the same period (the control group). There was no significant difference in gender, age, injury cause, side of fracture, types of fracture, and time from injury to operation between 2 groups (P>0.05). The operation time, intraoperative blood loss, intraoperative frequency of fluoroscopy and guide pin insertion, fracture healing time, fracture healing rate, and Harris hip score were compared between 2 groups. Results All incisions healed by first intention after operation, and no complication of blood vessel and nerve injury occurred. The operation time of trial group was significantly longer than that of control group (t=2.290,P=0.026), however, the intraoperative blood loss, intraoperative frequency of fluoroscopy and guide pin insertion of trial group were significantly less than those of control group (t=–10.650,P=0.000;t=18.320,P=0.000;t=–16.625,P=0.000). All patients were followed up 12-18 months (mean, 14.7 months). X-ray films showed that fracture healing was obtained in 2 groups, showing no significant difference in fracture healing time between 2 groups (t=0.208,P=0.836). No complication of ischemic necrosis of femoral head occurred during follow-up period. At last follow-up, the Harris hip score was 87.05±3.12 in trial group and was 86.78±2.83 in control group, showing no significant difference (t=0.333,P=0.741). Conclusion Computer-assisted cannulated screw internal fixation surgery based on error correction method for femoral neck fractures is better than traditional manual surgery in decreasing intraoperative radiation and surgical trauma during operation.
ObjectiveTo summarize the progress in treatment of pubic symphysis diastasis. MethodsRelated literature concerning treatment of pubic symphysis diastasis was extensively reviewed and comprehensively analyzed in terms of anatomy, biomechanics, and treatment. ResultsThere are many fixation methods for treatment of pubic symphysis diastasis, which aims at restoring the stability of the anterior pelvic ring. External fixator is often used as a temporary fixation; tension band wire has been abandoned due to its poor biomechanical stability; screw loosening and plate breakage often appears when a single reconstruction plate is used; box plate significantly increases the biomechanical stability of anterior pelvic ring but it leads to a considerable surgical trauma; locking plate has been used for pubic symphysis diastasis recently, especially for osteoporotic fractures; percutaneous cannulated screw has the advantages of less trauma, less bleeding, and good stability, so it is good choice for treatment of pubic symphysis diastasis. ConclusionThere is no uniform standards about the treatment of pubic symphysis diastasis, but the minimally invasive treatment is an undeniable trend. Percutaneous cannulated screw has achieved satisfactory effectiveness, however, its biomechanical stability and anatomic channels need to be further studied.
Objective To compare the effectiveness of arthroscopic screw and suture fixations in treatment of anterior cruciate ligament tibial eminence avulsion fractures. Methods Between January 2002 and January 2009, 43 patients with freshanterior cruciate ligament tibial eminence avulsion fracture were treated, which were rated as types II and III according to Meyers- McKeever-Zaricznyj classification. Fractures were fixed with either screw (screw group, n=21) or nonabsorbable suture (suture group, n=22). There was no significant difference in sex, age, disease duration, and fracture type between 2 groups (P gt; 0.05). The range of motion (ROM) and Lysholm score were compared between 2 groups, and the knee stabil ity was evaluated based on the Lachman test and KT-2000 measurement. Results The operation time was 48-60 minutes (mean, 51.6 minutes) in the screw group, and 55-68 minutes (mean, 63.2 minutes) in the suture group, showing significant difference (t=4.645, P=0.032). Incisions healed by first intention and no compl ication occurred in 2 groups. All patients were followed up (5.7 ± 0.6) years in the screw group and (5.3 ± 0.5) years in the suture group. The fracture healed completely in both groups; the heal ing time was (3.3 ± 0.6) months in the screw group and (3.2 ± 0.4) months in the suture group, showing significant difference (t=3.723, P=0.019). Between the screw group and the suture group, no significant difference was found in ROM [(128.6 ± 10.1)° vs. (130.2 ± 14.1)°, P gt; 0.05] and Lysholm score (94.6 ± 14.5 vs. 95.1 ± 17.2, P gt; 0.05). The stabil ities based on KT-2000 measurement were also similar between 2 groups at last follow-up [(0.9 ± 0.3) mm vs. (1.0 ± 0.4) mm, P gt; 0.05]. Lachman test of 2 groups were negative. Conclusion Boththe screw and nonabsorbable suture fixation techniques for anterior cruciate l igament tibial eminence avulsion fracture (type II or III) have good results in terms of functional outcome and stabil ity. However, some patients show flexion contractures of 5° or 10°.
ObjectiveTo investigate the effectiveness of individual percutaneous cannulated screws fixation of computer-assisted design combined with three-dimensional (3D) guide plate by comparing with cast immobilization and open internal fixation for treatment of Herbert type Ib scaphoid fracture. MethodsBetween January 2010 and June 2015, 56 patients with fresh Herbert type Ib scaphoid fracture were treated with cast immobilization in 16 cases (external fixation group), with open reduction and internal fixation in 20 cases (open reduction group), and with individual percutaneous cannulated screws fixation of computer-assisted design combined 3D guide plate in 20 cases (minimal invasion group). There was no significant difference in gender, age, injury cause, side, disease duration, and classification of fractures between groups P>0.05).The time of bone union, bone nonunion rate, return-to-work time, wrist range of motion (ROM), and Mayo function score were recorded and compared. ResultsPrimary healing of incision was obtained in open reduction group and minimally invasion group, without related complications. The cases were followed up 10-24 months (mean, 16.6 months). The time of bone union and return-to-work time of minimal invasion group were significantly shorter than those of the other 2 groups (P<0.05), and the rate of bone nonunion was significantly lower than that of the other 2 groups (P<0.05). At last follow-up, the wrist ROM of minimal invasion group[(104.40±3.46)°] was significantly larger than that of external group[(94.20±2.42)°] and open reduction group[(96.40±2.66)°] (P<0.05). According to Mayo function score, the results were excellent in 6 cases, good in 5 cases, fair in 2 cases, and poor in 3 cases in external fixation group, with an excellent and good rate of 69%; the results were excellent in 9 cases, good in 7 cases, fair in 2 cases, and poor in 2 cases in open reduction group, with an excellent and good rate of 80%; the results were excellent in 16 cases, good in 3 cases, and fair in1 case in minimal invasion group, with an excellent and good rate of 95%; there was significant difference in excellent and good rate among groups (P<0.05). ConclusionIndividual percutaneous cannulated screws fixation of computer-assisted design combined with 3D guide plate has satisfactory effectiveness in the treatment of Herbert type Ib scaphoid fractures, with the advantages of mini-invasion, high accuracy, high rate of bone union, less complication, early return-to-work time.
Objective To compare the curative effect of dynamic hi p screw (DHS) combined with anti-rotation screw and cannulated screw in treating patients with Pauwels type II or III femoral neck fracture and to provide the basis for the choice of surgical procedure. Methods Between March 2008 and September 2009, 51 patients with fresh Pauwels type II or III femoral neck fracture were treated with DHS combined with anti-rotation screw (DHS group) and three cannulated screws (cannulated screw group). The DHS group included 23 patients, 13 males and 10 females, aging 27-59 years (mean, 43.2 years); fracture was caused by fall ing in 1 case, by traffic accident in 17, by fall ing from height in 5 with a mean time of 27 hoursfrom injury to hospital ization (range, 12-70 hours); and 23 fractures included 9 Pauwels type II and 14 Pauwels type III femoral neck fracture. The cannulated screw group included 28 patients, 12 males and 16 females, aging 20-60 years (mean, 40.7 years); fracture was caused by fall ing in 1 case, by traffic accident in 22, by fall ing from height in 5 with a mean time of 25 hours from injury to hospital ization (range, 9-38 hours); and 28 fractures included 12 Pauwels type II and 16 Pauwels type III femoral neck fracture. There was no significant difference in the basel ine characteristics between 2 groups (P gt; 0.05). Results The incision heal ing of both groups by first intention was achieved. There were significant differences in operation time, incision size, operation blood loss, the cases of blood transfusion, the amount of blood transfusion, C reaction protein level on the 2nd postoperative day, and hospital ization days between 2 groups (P lt; 0.05). In DHS group, anatomic reduction was observed in 20 cases (86.96%) and satisfactory reduction in 3 cases (13.04%), while in cannulated screw group, anatomic reduction was observed in 25 cases (89.29%) and satisfactory reduction in 3 cases (10.71%) ; there was no significant difference (χ2=0.660, P=1.000). The patients were followed up 12-30 months with an average of 14.8 months. There was no significant difference (P gt; 0.05) in the rate of nonunion (10.71% vs. 0), the implant failure (3.57% vs. 0), and avascular necrosis of the femoral head (10.71% vs. 0) between the DHS group and the cannulated screw group. The union time was (94.5 ± 2.0) days in the DHS group and (106.0 ± 33.5) days in the cannulated screw group, showing no significant difference (t=—1.641, P=0.107). The re-opereation rates and the overall success rates were 25% and 75% in the cannulated group and were 0 and 100% in the DHS group, showing significant differences (χ2=6.650, P=0.012). At last follow-up, there was no significant difference in Harris hip score and visualanalogue scale (VAS) score between DHS group and cannulated screw group (P gt; 0.05). Conclusion The optimal treatment of young adults Pauwels type II or III femoral neck fracture is DHS combined with anti-rotation screw with an high overall success and less compl ications.