Abstract The narrow pedicled intercostal cutaneous perforater (np-ICP) thin flaps were successfully used for reconstruction of hand deformity from scar contraction. This flap was designed with a narrow pedicle (3~5cm in width) which included ICPs of 4th~9th intercostal spaces, and with awide distal part (the maximum is 15cm×15cm) which covered the lower chest and upper abdomen. The thickness of flap was cut until the subdermal vascular networkwas observed. The pedicle was divided between the 7th~14th days after operation. Sixteen flaps in 15 cases were transferred for covering of the skin defects at the dorsum of the hand. The perforators which were included in the narrow pediclewere mostly from the 7th intercostal spaces in 9 flaps. Fifteen of the 16 flapswere survived almost completely, except in one case there was necrosis of the distal portion of the flap. It seemed that this flap was more useful than the conventional methods, not only functionally but also aesthetically. Moreover, the operative techinque was more simple and safer than the island or free intercostalflap due to without the necessity to dissect the main trunk of the intercostalneurovascular bundle. Gentle pressure on the thinning portion of the flap for a short time after operation was important.
Objective To evaluate a new alternative method for thereconstruction of vagina with deep inferior epigastric perforator(DIEP) flap. Methods From January 2004 to May 2005, DIEP flaps were used for vaginal reconstruction in 5 patients(19 to 40 years), including 4 cases of congenital vaginal agenesis and 1 case of vaginal tumor. Before operation, the perforators were detected by theDoppler and the flaps based on the perforators ranged from 10 cm×9 cm to 12 cm×11 cm. DIEP flaps were elevated and then transferred to reconstruct the vagina. Results Deep inferior epigastric perforator flaps were used in 5 patients. Only 1 patient developed haematoma in the posterior aspect of thereconstructed vagina, but the flap was viable. The wounds healed secondarily after conservative therapy. All the flaps survived completely. No complication occurred at donor site of abdominal wall. Conclusion Despite technical difficulties in elevatingthe deep inferior epigastric perforator flap, the flap is a good choice for vaginal reconstruction.
Objective To investigate the operative technique and clinical effect of perforator-based flap for repair of glutealsacral skin defects. Methods A new perforator-based flap derived from the gluteal, parasacral and the lumbar arteries was used to repair skin defects ofglutealsacral region caused by trauma or pressure sore. The flap areas ranged from 6 cm×5 cm to 19 cm×11 cm, the diametre of perforating vessel ranged from 1.3 to 2.1 mm,the length of free perforating vessel pedicle ranged from 2.5 to 4.5 cm.Results All the flaps survived andthe wound gained primary healing. All the patients were followed up for 6 to 24months. The colour and texture of the flaps were excellent, the configuration was satifactory and there was no ulcer recurrence. Conclusion This new type of flap is characterized by delicate design, easy dissection, reliable blood supply, nosacrifice of the underlying muscle and no requirement skin graft for donor site closure. It is an optimalmethod in repairing soft tissue defects of the gluteal-sacral region.
Objective To investigate a method of improving design of the skin flap pedicled with descending branch of lateral femoral circumflex artery, in order to increase the accuracy of preoperative Doppler location. Methods Firstly, the interspace between rectus femoris and vastus lateralis was regarded as line A, and the point of intersection between line A and the vertical line through the midpoint of the line between anterior superior iliac spine and lateral margin of patella was point A. And then the line between the midpoint of groin and point A was regarded as line B. Based on this , the perforating point of cutaneous branch could be located by Doppler along the line B. From November 2001 to October 2004, this method was used in 38 skin flaps of 37 cases, being all males and 16-48 years old. The area of the flap ranged from 7 cm×6 cm to 24 cm×16 cm. Results All the perforatingpoint of cutaneous branch were located outward the line A. The rate that the preoperative Doppler location was consistent with the utility point of formatting skin flap was 97.4%. All the cases were followed up postoperatively 1-20 months. Among the cases, 36 skin flaps of 35 cases was successful and only 2 skin flaps partially necrosed, which healed after changing dressings or skin graft.Out of 35 cases, the sensation restoration of the skin flap was S2-S3 in 6 cases owing to the anastomosis of lateral femoral cutaneous nerve and a skin nerve of the recipient site, while that of the other cases was S0-S1. Conclusion Preoperative Doppler location and improving design of lineB can be a useful instruction for the design of skin flap pedicled with descending branch of lateral femoral circumflex artery.
ObjectiveTo explore the application value of infrared thermography (IRT) technique assisted peroneal artery perforator flap in repairing oral and maxillofacial defects. MethodsThe clinical data of 20 patients with oral and maxillofacial malignant tumors treated with peroneal artery perforator flap between October 2020 and December 2021 were retrospectively analysed. There were 13 males and 7 females, with an average age of 56.5 years (range, 32-76 years). There were 8 cases of tongue cancer, 5 cases of parotid gland cancer, 4 cases of buccal cancer, and 3 cases of mandibular gingival cancer; and 12 cases of squamous cell carcinoma, 3 cases of adenoid cystic carcinoma, and 5 cases of mucoepidermoid carcinoma. Color Doppler ultrasound (CDU) and IRT technique were performed before operation to locate the peroneal artery perforator and assist in the design of the flap. The sensitivity, specificity, positive predictive value, and negative predictive value of CDU and IRT technique were compared with the actual exploration during operation. The accuracy of CDU and IRT technique in detecting the number of peroneal artery perforator and the most viable perforating points was compared. The patients were followed up regularly to observe the recovery of donor and recipient sites, the occurrence of complications, and the recurrence and metastasis of tumors. Results The sensitivity, specificity, positive predictive value, and negative predictive value of peroneal artery perforators detected by IRT technique before operation were 72.22%, 50.00%, 92.86%, and 16.67% respectively, which were higher than those by CDU (64.17%, 33.33%, 84.62%, and 14.29% respectively). Forty-five peroneal artery perforators were found by CDU before operation, and 35 were confirmed during operation, with an accuracy rate of 77.8%; 43 “hot spots” were found by IRT technique, and 32 peroneal artery perforators were confirmed within the “hot spots” range during operation, with an accuracy rate of 74.4%; there was no significant difference between the two methods (χ²=0.096, P=0.757). The accuracy rates of the most viable perforating points found by CDU and IRT technique were 80.95% (17/21) and 94.74% (18/19), respectively, and there was no significant difference between them (χ²=0.115, P=0.734). The localization errors of CDU and IRT technique were (5.12±2.10) and (4.23±1.87) mm, respectively, and there was no significant difference between them (t=1.416, P=0.165). All the perforator flaps survived, and the incisions of donor and recipient sites healed by first intention. All patients were followed up 5-18 months, with an average of 11 months. The skin flap was soft and had good blood supply, and the lower limb scar was concealed and the lower limb had good function. No lower limb swelling, pain, numbness, ankle instability, or other complications occurred, and no tumor recurrence and metastasis were found during the follow-up. Conclusion Compared with the CDU, using the IRT technique to assist the preoperative peroneal artery perforator flap design to repair the oral and maxillofacial defects has a high clinical application value.
Objective To investigate the effectiveness of the perforator-based propeller flaps (PPFs) based on digital artery (DA) and dorsal metacarpal artery (DMA) in repairing hand wounds. Methods The clinical data of 45 patients with hand wounds between January 2018 and March 2023 were retrospectively analyzed. There were 27 males and 18 females with an average age of 41.2 years (range, 14-72 years). The causes of injury included twist injury in 15 cases, crush injury in 19 cases, and cut injury in 11 cases. The injured parts included 32 cases of digits, 10 cases of dorsal hand, and 3 cases of palmar hand, all of which had tendon, joint, and bone exposure. The time from injury to operation ranged from 2 to 8 hours (mean, 4.3 hours). The wound sizes after debridement ranged from 1.8 cm×1.0 cm to 5.0 cm×3.5 cm. Twenty-eight cases were repaired by the PPFs based on DA and 17 cases were repaired by the PPFs based on DMA. The flap size ranged from 2.5 cm×1.1 cm to 8.5 cm×4.0 cm. The defects of the donor sites in 14 patients were closed directly and the defects in the left 31 patients were resurfaced with free full-thickness skin graft from the proximal medial forearm.Results All the flaps survived after operation. Two cases of the PPF based on DA and 1 case of the PPF based on DMA underwent partially blisters at the distal end and healed after dressing change. The incisions in the donor site healed by first intention and the skin grafts survived. All patients were followed up 10-33 months, with a mean of 15.4 months. At last follow-up, the static two-point discrimination of the PPFs based on DA and DMA were 4-14 mm and 8-20 mm with the averages of 8.1 mm and 13.3 mm, respectively. According to the Michigan Hand Outcomes Questionnaire, 20 patients were very satisfied with the appearance of the PPF based on DA and 8 patients were satisfied; 8 patients were very satisfied with the appearance of the PPF based on DMA and 9 patients were satisfied. Based on the Vancouver Scar Scale (VSS), the appearance scores of the donor site of the PPFs based on DA and DMA were 2-7 and 4-9, with the averages of 4.2 and 6.1, respectively. ConclusionThe two kinds of PPFs are reliable in blood supply and easy to harvest, which provide a good method for emergency repair of small and medium area wounds in the hand.