west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "粉碎性" 22 results
  • 自锁髓内钉在肱骨粉碎性骨折的应用

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • 锁骨粉碎性骨折合并锁骨下静脉损伤二例

    详见正文

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
  • 闭合复位带锁髓内钉固定治疗股骨干粉碎性骨折

    目的 评价应用闭合复位带锁髓内钉固定治疗股骨干粉碎性骨折的临床疗效。 方法 1999年8月~2005年4月,采用闭合复位顺行带锁髓内钉固定技术治疗股骨干粉碎性骨折70例。男54例,女16例;年龄17~58岁。骨折均位于股骨转子下2 cm至股骨髁上5 cm。按AO分型: B型17例,C型53例。受伤至手术时间为1~12 d,平均5.8 d。 结果 B型骨折患者手术时间为90~250 min,C型骨折患者60~180 min。70例失血量50~450 ml,平均230 ml。术中3例发生骨劈裂,1例C型骨折远端1枚锁钉锁入失误,7例肢体短缩1.0~1.5 cm。68例获随访10~60个月,平均19个月。63例于术后3~10个月骨折愈合,5例于术后3~4个月行远端锁钉取出动力化后4~10个月骨折愈合。60例髋、膝关节功能活动优良, 余8例髋或/和膝关节功能受限。 结论 闭合复位带锁髓内钉固定是治疗股骨干粉碎性骨折有效方法之一,具有损伤小、失血少、骨折愈合率高、功能恢复好的优点。

    Release date:2016-09-01 09:23 Export PDF Favorites Scan
  • COMPARISON OF TWO DIFFERENT OPERATIONS ON COMMINUTED INTERCONDYLAR FRACTURE

    Objective To compare the effect of two different operations on treating severely comminuted intercondylar fracture. Methods From December 2001 to October 2003, 20 cases of severely comminuted intercondylar fracture were operated. Of the 20 cases, 7(group 1) were treated with closed reduction and retrograde intramedullary nailing through arthroscope, 13(group2) were treated with open reduction and retrograde intramedullary nailing without arthroscope. Follow-ups were conducted after operation. Results All cases of fracture were recovered. Swelling in group 1 was alleviated more obviously than that in group 2. In group 1, all knees could flex to 120° during 6th to 9th weeks after the operation. In group 2, only 4 could flex 110°.Conclusion Retrograde intramedullary nailing through arthroscope proves to be less invasive and more effective in treating heavily comminuted intercondylar fracture.

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • CLINICAL STUDY OF SODIUM HYALURONATE IN SUPPLEMENTARY TREATMENT OF COMMINUTED FRACTURE OF ANKLE

    OBJECTIVE To investigate the effects of sodium hyaluronate in supplementary treatment of comminuted fracture of ankle. METHODS Thirty-seven patients suffered from comminuted fracture of ankle were operated for restoration by routing methods, and received 2 ml of sodium hyaluronate injection intra-articularly before the closure of incision. The ankle was fixed and given the second intra-articular injection on the 3rd day after operation. Then, the patients were given sodium hyaluronate injection intra-articularly at a week intervals till the paste was removed after 4 weeks. All patients were followed up. The clinical results were evaluated by measuring the symptoms of pain, and the function of walking and other daily living activities. RESULTS All the patients were followed up for 6 to 27 months, among them, 30 patients were cured completely without any symptoms, the ankle function for walking and daily living activities was normal, 6 patients felt pain with violent activity or walking exceeding 1 km, one patient suffered from comminuted fracture with compressed depression was not improved due to his ankle being not restored properly. CONCLUSION Intra-articular injection of sodium hyaluronate is an effective supplementary treatment for comminuted fracture of ankle.

    Release date: Export PDF Favorites Scan
  • 上颌骨粉碎性骨折整复治疗的临床分析

    目的 探讨上颌骨粉碎性骨折的病因、并发症、检查方法及骨折整复的治疗时机、手术入路、整复材料和预后。方法 1998年5月~2005年12月,收治48例上颌骨粉碎性骨折患者。男40例,女8例;年龄16~50岁。车祸伤36 例,暴力伤 6 例,坠落伤6例。主要表现咬牙合关系障碍,张口受限,面中部凹陷畸形。20例采用钢丝内固定术,28 例采用钛板坚强内固定术 (rigid internal fixation, RIF)。结果 48例中Ⅰ类伤口31处、Ⅱ类伤口38处,术后均甲级愈合。48例患者均获随访1~3年。术前临床症状明显改善或消失。疗效评估:行钢丝固定患者满意8例,一般12例;行RIF患者满意24例,一般4例,两种方法比较差异有统计学意义(Plt;0.05)。结论 引起功能障碍和畸形的上颌骨粉碎性骨折均应行外科整复治疗, RIF为目前理想的固定技术之一。

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • Biomechanics test of fixation of star-shaped six-part patellar fractures with petal-shaped poly-axial locking plate

    ObjectiveTo compare the biomechanical difference between petal-shaped poly-axial locking plate and tension band wire cerclage in fixing star-shaped 6-part patellar fractures in cadaver model, and provide the experimental data for clinical use.MethodsThe paired 12 knee specimens from 6 human cadavers were randomly divided into 2 groups (the control group and the test group) after a star-shaped 6-part patellar fracture model was established. The specimens were weighted, and the control group was fixed with tension band wire cerclage and the test group was fixed with petal-shaped poly-axial locking plate. The specimens were connected to CMT5105 biomechanics test machine by a customized fixture, the total fracture gap of patellar fracture blocks was measured before testing. The knee extensor load test was performed to record the extensor load of knees at 90° flexion to extension. Then the anti gravity physiological knee extension process at 90° flexion was stimulated according to the knee extensor load. The cyclic times until failure and the total fracture gap of patellar fracture blocks after failure were recorded.ResultsThe specimens weight and the total fracture gap of patellar fracture blocks before testing between 2 groups had no significant difference (t=0.410, P=0.690; t=0.650, P=0.530). In the biomechanical test, there was no significant difference of knee extension load between 2 groups (t=0.490, P=0.638). The total fracture gap after failure in test group was significantly smaller than that in control group (t=3.026, P=0.013), and the cyclic times until failure in test group was significantly more than that in control group (t=2.277, P=0.046). The failure reasons in control group were all the wires slipped off the Kirschner wires, while the failure reasons in test group were the screws pulled out from the upper pole in 5 cases (83.3%) and from the lower pole in 1 case (16.7%).ConclusionThe petal-shaped poly-axial locking plate has better biomechanical stiffness to fix the star-shaped 6-part patellar fractures when compared with tension band wire cerclage method. However, this type of fracture is a serious comminuted type, and the early excessive activity still carries the risk of displacement.

    Release date:2018-03-07 04:35 Export PDF Favorites Scan
  • TREATMENT OF COMMINUTED FRACTURES AT DISTAL FEMUR AND PROXIMAL TIBIA WITH LESS INVASIVE STABILIZATION SYSTEMS

    Objective To study the clinical outcome of comminuted factures at distal femur and proximal tibia treated with AO less invasive stabilization systems (LISS). Methods The clinical data of 14 cases of distal femoral fracture and proximal tibial fracture from September 2003 to May 2005 were analyzed retrospectively. The injury was caused by traffic accident in 9 cases, by fall in 3 cases and by slipping in 2 cases. Of 14 cases, there were 5 open fractures and 9 close fractures, including 5 cases of distal femoral comminuted fracture and 9 cases of proximal shaft comminuted fractures. According to AO/OTA classification, the fractures were classified as 33C2 in 3 cases,33C3 in 2 cases,41A2 in 2 cases,41A3 in 2 cases,41B2 in 3 cases and 41C2 in 2 cases. All patients were treated by the internal fixation with LISS-distal femur or with LISS-proximal tibia. Healing of wounds, the X-ray films before and after operations, and therecovery of joint function were observed. Results The patients were followed up from 1 month to 20 months (11 months on average). Twelve cases achieved solid osseous unions from 3 months to 5 months postoperativly; 2 cases had a good reduction and recovered smoothly 2-3 months postoperatively. The results were excellent in 10 cases, good in 3 cases and fair in 1 case according to Johner-Wruhs knee scoring. The range of knee flexion-extension was 110-130° in 11 cases, 100° in 2 cases and 80° in 1 case. Conclusion LISS is an effective method of internal fixation for treating comminntedfracture of distal femur or proximal tibia. It has the advantages of less injury, satisfied reduction and reliable fixation.

    Release date:2016-09-01 09:26 Export PDF Favorites Scan
  • PRELIMINARY APPLICATION OF THREE-DIMENSIONAL PRINTING PERSONALIZED EXTERNAL FIXATOR IN SERIOUS TIBIOFIBULA FRACTURES

    ObjectiveTo explore a new method of treating serious tibiofibula comminuted fracture by using three-dimensional (3-D) printing personalized external fixator. MethodsIn April 2015, a male patient (aged 18 years with a height of 171 cm and a weight of 67 kg) with left tibiofibula comminuted fracture was included in the study. Computer-assisted reduction technique combined with 3-D printing was used to develop a customised personalized external fixator for fracture reduction. The effectiveness was observed. ResultsThe operation time was about 10 minutes without fluoroscopy, and successful reduction was obtained. The patient had equal limb length after operation. X-ray films showed that the posterior angulation of distal fracture was corrected 37°, and the eversion angle was corrected 4°. The tibial fractures had good paraposition or alignment, and the lower limb force line was corrected completely. No new fracture displacement occurred. The clinical healing time of fracture was 3.5 months and the bone union was achieved after 8 months. The function of affected limb recovered well after operation. ConclusionA personalized external fixator for serious tibiofibula comminuted fracture reduction made by 3-D printing technique has the merits of easy manipulation, high individuation, accurate reduction, stable fixation, and no need of fluoroscopy.

    Release date: Export PDF Favorites Scan
  • TREATMENT OF DISTAL COMMINUTED HUMERAL FRACTURE WITH SERIOUS OSTEOPOROSIS BY TOTAL ELBOW ARTHROPLASTY

    Objective To analyse short-term cl inical effect of total elbow arthroplasty in treatment of distal comminuted humeral fracture with serious osteoporosis in geratic patients. Methods From April 2006 to October 2007, five cases of distal comminuted humeral fractures were treated by total elbow arthroplasty with bone cement. Of them, there were 2 males and 3 females, aging 50-76 years old (mean 67.6 years old), including 4 cases of closed fracture and 1 case of open fracture (II type Gustilo-Anderson). All fractures were caused by tumbl ing. According to classification of AO, there were 2 cases of type C1, 2 cases of type C2 and 1 case of type C3. The Barnett index of osteoporosis was 0.40-0.45. The time from injury to operation was 4 to 18 days (mean 7.2 days). The rehabil itation exercise of function was done after 2 days of operation. Results The operative time was from 120 to 180 minutes (mean 150 minutes), the bleeding amount was from 150 to 250 mL (mean 200 mL). All incision achieved primary heal ing. No compl ication occurred. Five cases were followed up for 19 to 36 months (mean 24.5 months). The mean motion range of elbow joint include 141.6° for flection, 6.5° for extention, 10.2° for the degree of ectropion, 81.7° for revolve forward, and 73.8° for revolve behind respectively after 4 months of operation. The length discrepancy of upper l imb was less than 1.5 cm, the muscle force for flexion and extention of finger and wrist was normal. The X-ray films showed that the position of artificial joint was satisfactory without prosthesis dislocation or loosening. According to Mayo elbow performance score, the excellent and good rate was 80% (excellent in 1 case, good in 3 cases, and fair in 1 case). Conclusion Total elbow arthroplasty with bone cement is an effective method in treatment of distal comminuted humeral fracture with serious osteoporosis obviously in the geratic patients, but indication and technique of operation should be mastered strictly.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content