Objective To investigate the feasibility and early efficacy of transapical transcatheter aortic valve replacement (TAVR) combined with transcatheter mitral valve edge-to-edge repair (TEER) in patients with high-risk aortic valve lesions combined with severe mitral regurgitation. Methods The clinical data of patients who underwent "one-stop" transapical TAVR+TEER in our hospital from August 2022 to October 2023 were retrospectively analyzed. Results Five patients were collected, including 3 males and 2 females with a mean age of 66.6±1.8 years. Four patients had aortic valve insufficiency combined with mitral regurgitation and one had aortic valve stenosis and insufficiency combined with mitral regurgitation. All patients successfully completed transapical TAVR+TEER, and the immediate postoperative echocardiographic results revealed that none of them had more than mild perivalvular leakage and mitral regurgitation, and the prosthetic valves were in good position and function. At 1 week postoperatively, echocardiographic results showed 5 patients with no displacement of the prosthetic valve, detachment of the mitral clip, or damage to the leaflets. At 1 month postoperatively, cardiac function was improved to varying degrees in 4 patients, and 1 patient died of multiorgan failure. At 2 months postoperatively, 1 patient died of cerebrovascular accident, and at 3 months postoperatively the echocardiographic results of the remaining 3 patients revealed that there was no more than mild perivalvular leakage or mitral regurgitation, and the patients' postoperative cardiac function and daily life ability were significantly improved. Conclusion In high-risk aortic valve lesions combined with severe mitral regurgitation, "one-stop" transapical TAVR+TEER is feasible with favorable early efficacy and safety.
ObjectiveTo research the procedure for creating an animal model of mitral regurgitation by implanting a device through the apical artificial chordae tendineae, and to assess the stability and dependability of the device. MethodsTwelve large white swines were employed in the experiments. Through a tiny hole in the apex of the heart, the artificial chordae tendineae of the mitral valve was inserted under the guidance of transcardiac ultrasonography. Before, immediately after, and one and three months after surgery, cardiac ultrasonography signs were noted. Results All models were successfully established. During the operation and the follow-up, no swines died. Immediately after surgery, the mitral valve experienced moderate regurgitation. Compared with preoperation, there was a variable increase in the amount of regurgitation and the values of heart diameters at a 3-month follow-up (P<0.05). ConclusionIn off-pump, the technique of pulling the mitral valve leaflets with chordae tendineae implanted transapically under ultrasound guidance can stably and consistently create an animal model of mitral regurgitation.
Transcatheter aortic valve replacement (TAVR) has become the preferred treatment for severe aortic stenosis. The localization and anchor of many transcatheter heart valves available in the clinic today are dependent on the calcific aortic valve leaflet of patients. We reported here a successful case of transapical aortic valve implantation with Ken-Valve heart valve in an 82-year-old male patient with pure severe aortic regurgitation without native valve calcium. Postoperative follow-up (3 months after the surgery) showed that the cardiac function significantly improved. The echocardiography indicated that the Ken-Valve prosthesis worked well without perivalvular regurgitation. The short-term clinical effect was satisfactory. The Ken-Valve with three position anchors is proved to be suitable for the treatment of pure aortic regurgitation.
ObjectiveTo compare the in-hospital outcomes of transapical transcatheter aortic valve replacement (TA-TAVR) for bicuspid aortic valve (BAV) patients and tricuspid aortic valve (TAV) patients. MethodsPatients (including BAV and TAV patients) who underwent TA-TAVR with the J-ValveTM in West China Hospital from July 2014 to July 2020 were included consecutively. The clinical outcomes of the patients were analyzed. ResultsA total of 354 patients were included in the study, 75 in the BAV group and 279 in the TAV group. There were 229 males and 125 females with a mean age of 72.2±6.0 years. No death occurred during the procedure, and the overall technical success rate was 97.7%. The all-cause in-hospital mortality rate was 1.4%. Twenty (26.7%) patients with BAV and 46 (16.5%) patients with TAV had mild or higher perivalvular leaks immediately after the procedure. No patients with BAV required permanent pacemaker implantation postoperatively, while 13 (4.7%) TAV patients required permanent pacemaker implantation, with an overall pacemaker implantation rate of 3.7%. One (1.3%) BAV patient and 7 (2.5%) TAV patients developed acute kidney injury postoperatively. One (1.3%) BAV patient and 1 (0.4%) TAV patient developed perioperative myocardial infarction. The average postoperative hospital stay was 7.6±3.6 d for BAV patients and 8.6±6.1 d for TAV patients. There was no statistical difference in primary or secondary in-hospital outcomes between BAV and TAV patients (P>0.05). ConclusionCompared to TAV patients, BAV patients have similar in-hospital outcomes, with a low incidence of adverse clinical outcomes, which provides preliminary evidence for its implementation in Chinese patients with a high proportion of BAV.
Objective To compare the differences of transcatheter edge-to-edge repair (TEER) between trans-apical and trans-femoral groups in the treatment of mitral regurgitation. Methods A retrospective study was conducted on the patients who underwent TEER surgery at Tianjin Chest Hospital from February 2023 to October 2024. Patients were divided into two groups based on the surgical approach: trans-apical approach group and trans-femoral approach group. Baseline conditions, perioperative and postoperative 6-month survival status, and echocardiographic follow-up indicators were collected and compared between the groups. The primary endpoint indicators were all-cause mortality and device success rate. Secondary endpoint indicators included catheterization duration, heart failure readmission rate, and incidence of moderate or greater mitral regurgitation. Results A total of 33 patients were included, with 16 in the trans-femoral approach group and 17 in the trans-apical approach group. The average age was (69.85±7.86) years, and 17 patients (51.5%) were male. There were no statistically significant differences between the two groups in demographic characteristics, STS scores, comorbidities (except for diabetes), and laboratory tests. The proportion of patients with preoperative heart function≥grade Ⅲ was higher in the trans-apical approach group (88.2% vs. 43.8%, P=0.007), and the left ventricular end-diastolic diameter was smaller [(58.41±7.13)mm vs. (65.81±11.58) mm, P=0.033]. The catheterization operation time was shorter in the trans-apical approach group [40.00 (30.00, 61.00) min vs. 74.00 (56.25, 108.25) min, P=0.002]. There were no statistically significant differences between the two groups in all-cause mortality, device success rate, and heart failure readmission rate. Conclusion TEER surgeries via different approaches might have the same safety and efficacy. The trans-apical TEER surgery is simpler to operate, has a shorter learning curve, and is easier for beginners to master.
ObjectiveTo compare the early clinical efficacy and safety of transapical transcatheter aortic valve implantation (TA-TAVI) with surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis (AS). MethodsA retrospective study was conducted on patients with severe AS admitted to the Department of Cardiovascular Surgery, The First Affiliated Hospital of University of Science and Technology of China from January 2020 to March 2024. According to the surgical method, patients were divided into a SAVR group and a TA-TAVI group, and the clinical data of the two groups were compared. ResultsA total of 71 patients were included, with 45 in the SAVR group, including 33 males and 12 females, aged 16-75 (60.89±10.88) years; 26 in the TA-TAVI group, including 15 males and 11 females, aged 61-83 (72.85±5.53) years. The results showed that postoperative aortic valve transvalvular flow velocity (2.31±0.38 m/s vs. 2.60±0.50 m/s, P=0.019) and transvalvular pressure gradient (21.09±6.03 mm Hg vs. 28.20±10.79 mm Hg, P=0.001) in the TA-TAVI group were lower than those in the SAVR group. In terms of left ventricular end-diastolic diameter, both preoperative (56.73±7.74 mm vs. 52.36±7.00 mm, P=0.017) and postoperative (52.61±7.18 mm vs. 48.04±4.78 mm, P=0.010) values in the TA-TAVI group were larger than those in the SAVR group. In terms of left ventricular ejection fraction, the preoperative value in the TA-TAVI group was lower than that in the SAVR group (58.00%±13.84% vs. 64.87%±7.63%, P=0.026), but there was no statistical difference between the two groups after surgery (P=0.670). The operation time and drainage volume on the first day after surgery in the TA-TAVI group were shorter or lower than those in the SAVR group (P<0.05). There was no statistical difference between the two groups in the postoperative hospital stay, ICU stay, or postoperative mechanical ventilation time (P>0.05). In addition, no serious complications occurred in patients after SAVR, while perivalvular leakage (2 patients), third-degree atrioventricular block (1 patient), and death (3 patients) occurred in the TA-TAVI group. ConclusionFor elderly patients with severe AS and poor cardiac function, TA-TAVI technology has minimal surgical trauma, high safety and effectiveness, and is a safe and effective treatment option besides traditional surgical operations.
An 81-year-old male patient was admitted to Guangdong Provincial People's Hospital due to chest distress and shortness of breath after activity for half a year. Examination after admission revealed severe aortic insufficiency, tricuspid aortic valve and extremely horizontal aorta with an aortic root angulation of 99°. The Society of Thoracic Surgeons score was 7%. And taking the strong demand of the patient and his family into consideration, we decided to perform transapical transcatheter aortic valve replacement after multidisciplinary evaluation. The procedure was successfully performed by means of low deployment land zone and traction of pre-exist Prolene suture. Three-month follow-up confirmed the normal function of aortic prosthetic valve without residual regurgitation. This case provides a reference for the interventional treatment in patients with extremely horizontal aorta.
ObjectiveTo determine the clinical efficacy of transapical transcatheter mitral valve-in-valve treatment for patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement.MethodsThe clinical data of 9 patients who underwent transapical transcatheter mitral valve-in-valve implantation after aortic-mitral double valve replacement due to mitral bioprosthesis deterioration from May 2020 to January 2021 in our hospital were retrospectively analyzed, including 4 males and 5 females with a mean age of 72.44±7.57 years.ResultsSurgeries were performed successfully in all patients with no conversion to median sternotomy. The mean procedural time was 101.33±48.49 min, the mechanical ventilation time was 23.11±26.54 h, the ICU stay was 1.89±1.05 d and the postoperative hospital stay was 6.11±2.02 d. Residual mild mitral regurgitation was only observed in 1 patient. Only 1 patient needed postoperative blood transfusion. No major complications were observed in all patients. There was no death in postoperative 90 days.ConclusionFor patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement, transapical transcatheter mitral valve-in-valve implantation achieves good clinical results and effectively improves the hemodynamics without increasing the risk of postoperative left ventricular outflow tract obstruction. The surgery is feasible and effective.