west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "肌钙蛋白" 29 results
  • 冠状动脉旁路移植术后血清肌钙蛋白T的动态变化

    目的 研究冠状动脉旁路移植术(CABG)后血清肌钙蛋白T(TnT)的动态变化及临床意义。方法 采用双抗体夹心酶联免疫吸附测定法(ELISA),测定37例患者CABG后血清TnT的浓度变化,并与肌酸激酶(CK)和肌酸激酶同工酶(CK-MB)进行比较。结果 TnT在CABG后4~12小时达到峰值,术后6~8天恢复正常。CK-MB于术后4~16小时升至峰值,术后48小时即恢复正常。CABG后TnT峰值与主动脉阻断时间呈正相关(r=0.55,P<0.05)。结论 TnT在CABG后对于诊断微小心肌损伤、判断预后具有高特异性、高敏感性。

    Release date:2016-08-30 06:34 Export PDF Favorites Scan
  • Effect of inhaling NO perioperatively on postoperative cardiac and pulmonary functions in infants with congenital ventricular septal defect complicated with severe pulmonary hypertension: A randomized controlled trial

    Objective To investigate the effect of low-flow inhaling NO for short time on postoperative cardiac and pulmonary functions in infants with congenital ventricular septal defect complicated with severe pulmonary hypertension. Methods Forty-five patients with congenital ventricular septal defect complicated with severe pulmonary hypertension from May 2014 to May 2016 in our hospital were enrolled. There were 19 males and 26 females, whose age ranged from 1 to 22 months (average age: 7.2±14.4 months) and weight ranged from 2.7 to 10.5 kg (average weight: 6.8±3.6 kg). The patients were randomly divided into three groups (n=15 in each): the blank group, the prior inhalation group and the posterior inhalation group. The blank group did not inhale NO, and the prior inhalation group inhalated NO for 10 min after tracheal and intubation. After the opening of the aorta, the posterior inhalation group inhaled NO for 10 min. The concentration of NO was 20 × 10–6. The pressure ratio of pulmonary circulation/systematic circulation, heart index and oxygenation index were calculated and the troponin value of the three groups was monitored 10 min after returning to intensive care unit (ICU) and postoperatively 1 h, 3 h and 24 h. Differences among above indicators between three groups were compared. Results The troponin value of the posterior inhalation group within 3 h increased most, followed by the blank group and the prior inhalation group. Postoperatively 1 h and 3 h, the troponin value of the prior inhalation group was significantly less than that of the blank group and posterior inhalation group (P<0.01) and the value on postoperative 24 h in each group was lower than that on postoperative 3 h. The cardiac index of prior inhalation group was higher than that of the blank group and the posterior inhalation group at each time point. Postoperatively 3 h and 24 has well as 10 min after returning to ICU, the cardiac index in prior inhalation group was significantly higher than that of the posterior inhalation group (P<0.05). The pressure ratio of pulmonary circulation/systematic circulation of posterior inhalation group increased more than that of blank group; the differences in two groups were significant between postoperative 3 h and 10 min after returning to ICU (P<0.01). There was no statistical significance in the pressure ratio on postoperative 24 h and 10 min after returning to ICU (P>0.05) in three groups. The index of oxygenation of the prior inhalation group was higher than that of the blank group and the posterior inhalation group and statistically different from that of posterior inhalation group (P<0.05). Conclusion Inhaling NO 10 min preoperatively can reduce the injury to the heart and lung function effectively, but the result is the opposite when inhalating NO 10 min after aorta opening.

    Release date:2017-07-03 03:58 Export PDF Favorites Scan
  • 心脏不停跳与冷晶体停搏在常见先心病矫治术中对肌钙蛋白I的影响

    目的 探讨常见先天性心脏病矫治术中心脏不停跳与心脏停搏两种术式对心肌肌钙蛋白 I(c Tn I)的影响及其心肌保护的效果。 方法  36例先天性心脏病矫治术患者按入院顺序以奇偶数随机分为心脏不停跳组 (组II)和冷晶体停搏组 (组I)两组 ,每组 18例。分别于术前、主动脉开放后 (组 为缝合右心房壁后 ) 1、2 4、4 8、72和 96 h取患者中心静脉血 ,测定 c Tn I、肌酸激酶 (CK)、肌酸激酶同工酶 (CK- MB)、乳酸脱氢酶 (L DH) ,并用透射电子显微镜观察两组各前 10例患者心内操作前、后心肌超微结构。 结果 两组术后血清 c Tn I、CK、CK- MB和 L DH水平均不同程度升高。两组 c Tn I均于术后 1h达峰值 ,主动脉开放后各时点组II显著高于组I(t=- 32 3.0 4 ,Plt;0 .0 1) ;组ICK-MB术后 2 4 h达峰值 ,组II术后 1h达峰值 ,主动脉开放后各时点组II显著高于组I(t=- 72 .5 3,Plt;0 .0 1) ;CK、L DH变化趋势与 CK- MB相似。组I术后心肌超微结构变化轻微 ,组II明显改变 ,...更多其受损程度分级较术前重。 结论 常见先天性心脏病矫治术中心脏不停跳可明显减轻心肌缺血、缺氧及再灌注损伤 ,减少 c Tn I的释放 ,较冷晶体停搏术有良好的心肌保护效果。

    Release date:2016-08-30 06:24 Export PDF Favorites Scan
  • The Diagnostic Value of Serum Cardiac Troponin Ⅰ in Acute Heart Failure

    目的:明确肌钙蛋白Ⅰ(cTnI)在心源性呼吸困难的鉴别诊断中有无应用价值。方法:比较急性心衰与急性肺源性呼吸困难时cTnI的变化情况,并观察一定的cTnI临界值辅助诊断心衰的敏感性和特异性。结果:总共156例患者,最后确诊为急性心衰的患者69例,而肺源性呼吸困难患者87例。急性心衰组的平均cTnI值为076±085ng/dL,而肺源性呼吸困难组为025±032ng/dL,两组间有显著性差异(Plt;0001)。根据ROC曲线计算肌钙蛋白Ⅰ的临界值(截点值)为042ng/dL,其鉴别心衰的敏感度为7153%,特异度为9036%,准确度为8014%。结论:检测肌钙蛋白Ⅰ水平并与其它临床信息相结合,有助于快速准确地诊断充血性心力衰竭。

    Release date:2016-09-08 09:56 Export PDF Favorites Scan
  • Correlation Analysis on Effect of Fetal Distress on Changes of Cardiac Enzyme in Neonatal Serum

    【摘要】 目的 探讨胎儿宫内窘迫对足月新生儿血清心肌酶变化的相关性分析。 方法 将2009年10月-2010年9月在我产科出生有宫内窘迫史而羊水和Apgar评分均正常的足月新生儿20例为观察组,同期出生的健康足月新生儿10例为对照组,分别测定两组出生后1、5 d血清肌酸激酶同工酶(CK-MB)及心肌肌钙蛋白I(cTnI)水平。 结果 观察组出生后1 d血清cTnI高于对照组(Plt;0.001),CK-MB两组差异无统计学意义(Pgt;0.05),出生后5 d血清CK-MB及cTnI均高于对照组(Plt;0.001);观察组和对照组出生后5 d血清cTnI水平均较1 d时升高,差异有统计学意义(Plt;0.001),血清CK-MB浓度均低于1 d时(Plt;0.001)。观察组患儿经过治疗,1个月后复查血清cTnI除1例未恢复至正常水平外,其余血清CK-MB及心电图均恢复正常。 结论 单纯宫内窘迫可造成足月新生儿血清cTnI及CK-MB水平升高,常规检测血清cTnI及CK-MB能及时了解此类新生儿的心肌受损情况,从而尽早予以保护心肌治疗。【Abstract】 Objective To make a correlation analysis on effect of fetal distress on changes of cardiac enzyme in neonatal serum. Methods Twenty full-term newborns who met diagnostic criteria of fetal distress but were born with normal amniotic fluid and Apgar score between October 2009 and September 2010 were included in the observed group, another ten normal full-term newborns born at same period were in control group. The serum values of cardiac troponin I (cTnI) and creatine kinase (CK-MB) were collected and measured one and five days after birth. Results One day after the birth, the serum levels of cTnI was significantly higher in the observed group compared to that in the control group (Plt;0.001), but there was no difference in CK-MB between the two groups (Pgt;0.05). The values of cTnI five days after the birth were higher than those one days after the birth in both groups (Plt;0.001). The values of CK-MB were higher one day after birth than those five days after birth in both groups (Plt;0.001). In observation group after the treatment, serum cTnI in one patient did not return to normal, and the remaining neonatal serum CK-MB and ECG were normal. Conclusions Elevated level of serum cTnI and CK-mb could be caused by fetal distress in normal full-term newborns with normal amniotic fluid and Apgar score. Routine testing of serum cTnI and CK-MB may be useful to detect myocardial damage in newborns.

    Release date:2016-09-08 09:27 Export PDF Favorites Scan
  • Predictive Value of the High-Sensitivity Cardiac Troponin I in Patients with Acute Pulmonary Embolism

    ObjectiveTo evaluate the predictive value of the high-sensitivity cardiac troponin I (hs-cTnI) in patients with acute pulmonary embolism (APE). MethodsIn a retrospective cohort study,272 consecutive patients with APE were reviewed and the 30-days death and in-hospital adverse events were evaluated. The patients were classified according to hs-cTnI value into a high hs-cTnI group and a low hs-cTnI group. The simple pulmonary embolism severity index (sPESI) was used for clinical risk determination. The adverse event was defined as intravenous thrombolytic therapy,noninvasive ventilator support to maintain oxygen saturation >90% and suffered with severe complications. The correlations of hs-cTnI with sPESI score,30-days adverse events and mortality were analyzed. The Kaplan-Meier curves and the log-rank test were used to compare time-to-event survival. Stepwise multivariate logistic regression analysis models were used to determine the incremental prognostic value of sPESI score and hs-cTnI. ResultsThe incidence of 30-day death (6.1%),renal failure (14.6%),bleeding (13.4%) and thrombolytic therapy (7.9%) were higher in the high hs-cTnI group than those in the low hs-cTnI group (P values were 0.009,<0.001,0.018 and 0.003,respectively). The patients with sPESI ≥1 and low hs-cTnI had greater free adverse events survival (P=0.005). hs-cTnI provided incremental predictive value for in-hospital adverse events,beyond the sPESI score (P<0.001). Conclusionhs-cTnI has excellent negative predictive value of APE prognosis,especially when used combined with sPESI score.

    Release date:2016-10-02 04:55 Export PDF Favorites Scan
  • 腺苷预处理对体外循环术后心肌肌钙蛋白变化的影响

    目的 探讨腺苷预处理对心脏直视手术的心肌保护效果.方法 30例择期心瓣膜置换术患者随机分成实验组和对照组,每组15例.实验组在术前行腺苷预处理.分别于转流前、主动脉阻断30分钟和60分钟、主动脉开放后30分钟及术后24小时采血测定心肌肌钙蛋白T(cTnT)、心肌酶谱和丙二醛.结果 腺苷预处理者cTnT和心肌酶外漏明显减少,丙二醛生成减少.结论 腺苷预处理能减轻心肌缺血再灌注损伤.

    Release date:2016-08-30 06:35 Export PDF Favorites Scan
  • 急性心肌梗死患者血浆P-选择素水平及临床意义

    【摘要】 目的 探讨急性心肌梗死患者血浆P-选择素(P-selectin,Ps)的含量及其意义。 方法 2009年12月-2010年5月间采用酶联免疫吸附试验分别测定35例冠心病患者、30例急性心肌梗死患者急性期及恢复期两个时期血浆中Ps、血清心肌肌钙蛋白I(cTnI)和肌红蛋白(Myo)含量,与20例健康体检者作对照。 结果 急性心肌梗死急性期与恢复期比较,Ps、cTnI和Myo水平明显上升(Plt;0.05);急性心肌梗死急性期与冠心病组比较也差异统计学意义(Plt;0.05),均高于对照组(Plt;0.05)。急性心肌梗死恢复期与冠心病组比较差异无统计学意义(Pgt;0.05)。 结论 Ps、cTnI和Myo水平升高与急性心肌梗死的进展有关,可作为鉴别诊断急性心肌梗死的指标。

    Release date:2016-09-08 09:26 Export PDF Favorites Scan
  • Prognostic significance of test of cardiac troponin T and renal function in acute type A aortic dissection

    Objective To measure the rate of changes of the cardiac troponin T (cTnT) and serum urea nitrogen (N), serum creatinine (Cr), estimated glomerular filtration rate (eGFR) of acute type A aortic dissection (AAAD) patients before and after surgery, and to explore the prognostic significance of the rate of changes. Methods We retrospectively analyzed 77 AAAD patients' clinical data between August 2015 and March 2016 from the department of the cardiothoracic surgery in Nanjing Drum Tower Hospital. There were 57 males and 20 females with an average age of 51.1±13.1 years. The test results of cTnT, N, Cr, eGFR were recorded. Patients were divided into three groups based on the duration of ventilation: less than 48 hours, 48 hours to 7 days, longer than 7 days, and divided into two groups based on whether postoperative dialysis was performed: dialysis group and non-dialysis group. Results In the groups with different duration of ventilation, the rate of cTnT change differed significantly. The rate of Cr and eGFR change in the group with the duration of ventilation longer than 7 days showed significantly different compared to other two groups. We found that the rate of Cr and eGFR change were statistically significant between the dialysis group and the non-dialysis group. In the receiver operating characteristic curve (ROC), the optimal cut-off value of the Cr growth rate for predicting postoperative dialysis therapy was 58.1%, and the optimal cut-off value of the eGFR decline rate was 45.5%. Conclusion The rate of changes in cTnT, N, Cr and eGFR can be used as a reliable mean to evaluate respiratory and renal function for AAAD patients in the early stage, which will facilitate an early assessment of the prognosis of AAAD patients.

    Release date:2017-03-24 03:45 Export PDF Favorites Scan
  • A Troponin Detection-combined Study of Rabbit Experiment for Evaluating Cardiac Fatigue

    The objective of this study is to combine troponin and indicators of cardiac acoustics for synthetically evaluating cardiac fatigue of rabbits, analyzing exercise-induced cardiac fatigue (EICF) and exercise-induced cardiac damage (EICD). New Zealand white rabbits were used to conduct a multi-step swimming experiments with load, reaching an exhaustive state for evaluating if the amplitude ratio of the first to second heart sound (S1/S2) and heart rate (HR) during the exhaustive exercise would decrease or not and if they would be recovered 24-48 h after exhaustive exercise. The experimental end point was to complete 3 times of exhaustions or death from exhaustion. Circulating troponin I (cTnI) were detected from all of the experimental rabbits at rest [(0.02±0.01) ng/mL], which, in general, indicated that there existed a physiological release of troponin. After the first exhaustive swim, cTnI of the rabbits increased. However, with 24-hour rest, S1/S2, HR, and cTnI of the tested rabbits all returned toward baseline levels, which meant that the experimental rabbits experienced a cardiac fatigue process. After repeated exhaustion, overloading phenomena were observed, which led to death in 3 out of 11 rabbits, indicating their cardiac damage; the troponin elevation under this condition could be interpreted by pathological release. Evaluation of myocardial damage can not be based on the troponin levels alone, but can only be based on a comprehensive analysis.

    Release date: Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content