Objective To investigate the effect of low-flow inhaling NO for short time on postoperative cardiac and pulmonary functions in infants with congenital ventricular septal defect complicated with severe pulmonary hypertension. Methods Forty-five patients with congenital ventricular septal defect complicated with severe pulmonary hypertension from May 2014 to May 2016 in our hospital were enrolled. There were 19 males and 26 females, whose age ranged from 1 to 22 months (average age: 7.2±14.4 months) and weight ranged from 2.7 to 10.5 kg (average weight: 6.8±3.6 kg). The patients were randomly divided into three groups (n=15 in each): the blank group, the prior inhalation group and the posterior inhalation group. The blank group did not inhale NO, and the prior inhalation group inhalated NO for 10 min after tracheal and intubation. After the opening of the aorta, the posterior inhalation group inhaled NO for 10 min. The concentration of NO was 20 × 10–6. The pressure ratio of pulmonary circulation/systematic circulation, heart index and oxygenation index were calculated and the troponin value of the three groups was monitored 10 min after returning to intensive care unit (ICU) and postoperatively 1 h, 3 h and 24 h. Differences among above indicators between three groups were compared. Results The troponin value of the posterior inhalation group within 3 h increased most, followed by the blank group and the prior inhalation group. Postoperatively 1 h and 3 h, the troponin value of the prior inhalation group was significantly less than that of the blank group and posterior inhalation group (P<0.01) and the value on postoperative 24 h in each group was lower than that on postoperative 3 h. The cardiac index of prior inhalation group was higher than that of the blank group and the posterior inhalation group at each time point. Postoperatively 3 h and 24 has well as 10 min after returning to ICU, the cardiac index in prior inhalation group was significantly higher than that of the posterior inhalation group (P<0.05). The pressure ratio of pulmonary circulation/systematic circulation of posterior inhalation group increased more than that of blank group; the differences in two groups were significant between postoperative 3 h and 10 min after returning to ICU (P<0.01). There was no statistical significance in the pressure ratio on postoperative 24 h and 10 min after returning to ICU (P>0.05) in three groups. The index of oxygenation of the prior inhalation group was higher than that of the blank group and the posterior inhalation group and statistically different from that of posterior inhalation group (P<0.05). Conclusion Inhaling NO 10 min preoperatively can reduce the injury to the heart and lung function effectively, but the result is the opposite when inhalating NO 10 min after aorta opening.
目的:明确肌钙蛋白Ⅰ(cTnI)在心源性呼吸困难的鉴别诊断中有无应用价值。方法:比较急性心衰与急性肺源性呼吸困难时cTnI的变化情况,并观察一定的cTnI临界值辅助诊断心衰的敏感性和特异性。结果:总共156例患者,最后确诊为急性心衰的患者69例,而肺源性呼吸困难患者87例。急性心衰组的平均cTnI值为076±085ng/dL,而肺源性呼吸困难组为025±032ng/dL,两组间有显著性差异(Plt;0001)。根据ROC曲线计算肌钙蛋白Ⅰ的临界值(截点值)为042ng/dL,其鉴别心衰的敏感度为7153%,特异度为9036%,准确度为8014%。结论:检测肌钙蛋白Ⅰ水平并与其它临床信息相结合,有助于快速准确地诊断充血性心力衰竭。
【摘要】 目的 探讨胎儿宫内窘迫对足月新生儿血清心肌酶变化的相关性分析。 方法 将2009年10月-2010年9月在我产科出生有宫内窘迫史而羊水和Apgar评分均正常的足月新生儿20例为观察组,同期出生的健康足月新生儿10例为对照组,分别测定两组出生后1、5 d血清肌酸激酶同工酶(CK-MB)及心肌肌钙蛋白I(cTnI)水平。 结果 观察组出生后1 d血清cTnI高于对照组(Plt;0.001),CK-MB两组差异无统计学意义(Pgt;0.05),出生后5 d血清CK-MB及cTnI均高于对照组(Plt;0.001);观察组和对照组出生后5 d血清cTnI水平均较1 d时升高,差异有统计学意义(Plt;0.001),血清CK-MB浓度均低于1 d时(Plt;0.001)。观察组患儿经过治疗,1个月后复查血清cTnI除1例未恢复至正常水平外,其余血清CK-MB及心电图均恢复正常。 结论 单纯宫内窘迫可造成足月新生儿血清cTnI及CK-MB水平升高,常规检测血清cTnI及CK-MB能及时了解此类新生儿的心肌受损情况,从而尽早予以保护心肌治疗。【Abstract】 Objective To make a correlation analysis on effect of fetal distress on changes of cardiac enzyme in neonatal serum. Methods Twenty full-term newborns who met diagnostic criteria of fetal distress but were born with normal amniotic fluid and Apgar score between October 2009 and September 2010 were included in the observed group, another ten normal full-term newborns born at same period were in control group. The serum values of cardiac troponin I (cTnI) and creatine kinase (CK-MB) were collected and measured one and five days after birth. Results One day after the birth, the serum levels of cTnI was significantly higher in the observed group compared to that in the control group (Plt;0.001), but there was no difference in CK-MB between the two groups (Pgt;0.05). The values of cTnI five days after the birth were higher than those one days after the birth in both groups (Plt;0.001). The values of CK-MB were higher one day after birth than those five days after birth in both groups (Plt;0.001). In observation group after the treatment, serum cTnI in one patient did not return to normal, and the remaining neonatal serum CK-MB and ECG were normal. Conclusions Elevated level of serum cTnI and CK-mb could be caused by fetal distress in normal full-term newborns with normal amniotic fluid and Apgar score. Routine testing of serum cTnI and CK-MB may be useful to detect myocardial damage in newborns.
ObjectiveTo evaluate the predictive value of the high-sensitivity cardiac troponin I (hs-cTnI) in patients with acute pulmonary embolism (APE). MethodsIn a retrospective cohort study,272 consecutive patients with APE were reviewed and the 30-days death and in-hospital adverse events were evaluated. The patients were classified according to hs-cTnI value into a high hs-cTnI group and a low hs-cTnI group. The simple pulmonary embolism severity index (sPESI) was used for clinical risk determination. The adverse event was defined as intravenous thrombolytic therapy,noninvasive ventilator support to maintain oxygen saturation >90% and suffered with severe complications. The correlations of hs-cTnI with sPESI score,30-days adverse events and mortality were analyzed. The Kaplan-Meier curves and the log-rank test were used to compare time-to-event survival. Stepwise multivariate logistic regression analysis models were used to determine the incremental prognostic value of sPESI score and hs-cTnI. ResultsThe incidence of 30-day death (6.1%),renal failure (14.6%),bleeding (13.4%) and thrombolytic therapy (7.9%) were higher in the high hs-cTnI group than those in the low hs-cTnI group (P values were 0.009,<0.001,0.018 and 0.003,respectively). The patients with sPESI ≥1 and low hs-cTnI had greater free adverse events survival (P=0.005). hs-cTnI provided incremental predictive value for in-hospital adverse events,beyond the sPESI score (P<0.001). Conclusionhs-cTnI has excellent negative predictive value of APE prognosis,especially when used combined with sPESI score.
Objective To measure the rate of changes of the cardiac troponin T (cTnT) and serum urea nitrogen (N), serum creatinine (Cr), estimated glomerular filtration rate (eGFR) of acute type A aortic dissection (AAAD) patients before and after surgery, and to explore the prognostic significance of the rate of changes. Methods We retrospectively analyzed 77 AAAD patients' clinical data between August 2015 and March 2016 from the department of the cardiothoracic surgery in Nanjing Drum Tower Hospital. There were 57 males and 20 females with an average age of 51.1±13.1 years. The test results of cTnT, N, Cr, eGFR were recorded. Patients were divided into three groups based on the duration of ventilation: less than 48 hours, 48 hours to 7 days, longer than 7 days, and divided into two groups based on whether postoperative dialysis was performed: dialysis group and non-dialysis group. Results In the groups with different duration of ventilation, the rate of cTnT change differed significantly. The rate of Cr and eGFR change in the group with the duration of ventilation longer than 7 days showed significantly different compared to other two groups. We found that the rate of Cr and eGFR change were statistically significant between the dialysis group and the non-dialysis group. In the receiver operating characteristic curve (ROC), the optimal cut-off value of the Cr growth rate for predicting postoperative dialysis therapy was 58.1%, and the optimal cut-off value of the eGFR decline rate was 45.5%. Conclusion The rate of changes in cTnT, N, Cr and eGFR can be used as a reliable mean to evaluate respiratory and renal function for AAAD patients in the early stage, which will facilitate an early assessment of the prognosis of AAAD patients.
The objective of this study is to combine troponin and indicators of cardiac acoustics for synthetically evaluating cardiac fatigue of rabbits, analyzing exercise-induced cardiac fatigue (EICF) and exercise-induced cardiac damage (EICD). New Zealand white rabbits were used to conduct a multi-step swimming experiments with load, reaching an exhaustive state for evaluating if the amplitude ratio of the first to second heart sound (S1/S2) and heart rate (HR) during the exhaustive exercise would decrease or not and if they would be recovered 24-48 h after exhaustive exercise. The experimental end point was to complete 3 times of exhaustions or death from exhaustion. Circulating troponin I (cTnI) were detected from all of the experimental rabbits at rest [(0.02±0.01) ng/mL], which, in general, indicated that there existed a physiological release of troponin. After the first exhaustive swim, cTnI of the rabbits increased. However, with 24-hour rest, S1/S2, HR, and cTnI of the tested rabbits all returned toward baseline levels, which meant that the experimental rabbits experienced a cardiac fatigue process. After repeated exhaustion, overloading phenomena were observed, which led to death in 3 out of 11 rabbits, indicating their cardiac damage; the troponin elevation under this condition could be interpreted by pathological release. Evaluation of myocardial damage can not be based on the troponin levels alone, but can only be based on a comprehensive analysis.