west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "造影剂" 22 results
  • Application of Contrast-Enhanced Ultrasonography in Differential Diagnosis of Retroperitoneal Occupying Lesions

     Objective To evaluate the real-time contrast-enhanced ultrasonography (CEUS) in the differential diagnosis of retroperitoneal occupying lesions.  Methods Thirty patients with retroperitoneal occupying lesions, including 10 benign and 20 malignant lesions, were performed with CEUS, thus describing the perfusion of contrast agent, the entering style of contrast agent and the vascular morphous. And the entering styles were divided into two patterns: peripheral type or central type while the vascular morphous were divided into 4 levels: level 0, level 1, level 2 and level 3. All of these were compared between benign and malignant lesions. Compared the results of diagnosis malignant lesions by common ultrasonography with CEUS.  Results 1/5 case of benign substantive lesions presented as contrast agent perfusion defect, and 11/20 cases of substantive malignant lesions presented as contrast agent perfusion defect. 14/20 of malignant lesions were central type; 9/10 of benign lesions were peripheral type (P=0.005 2). In benign lesions, level 0 had 7/10, level 1 had 2/10 and level 3 had 1/10. In malignant lesions, level 0 had 1/20, level 1 had 3/20, level 2 had 8/20 and level 3 had 8/20, too (P=0.000 5). The rate of missed diagnosis was 40.00% and the accuracy was 66.67% by common ultrasonography, while the rate of missed diagnosis was 10.00% and the accuracy was 86.67% by CEUS combined with the entering style of contrast agent and the vascular morphous.  Conclusion The CEUS applies a new way to discriminate malignant from benign in retroperitoneal occupying lesions.

    Release date:2016-09-08 10:57 Export PDF Favorites Scan
  • Method for Extracting Vascular Perfusion Region Based on Ultrasound Contrast Agent

    Vascular perfusion distribution in fibroids contrast-enhanced ultrasound images provides useful pathological and physiological information, because the extraction of the vascular perfusion area can be helpful to quantitative evaluation of uterine fibroids blood supply. The pixel gray scale in vascular perfusion area of fibroids contrast-enhanced ultrasound image sequences is different from that in other regions, and, based on this, we proposed a method of extracting vascular perfusion area of fibroids. Firstly, we denoised the image sequence, and then we used Brox optical flow method to estimate motion of two adjacent frames, based on the results of the displacement field for motion correction. Finally, we extracted vascular perfusion region from the surrounding background based on the differences in gray scale for the magnitude of the rich blood supply area and lack of blood supply area in ultrasound images sequence. The experimental results showed that the algorithm could accurately extract the vascular perfusion area, reach the precision of identification of clinical perfusion area, and only small amount of calculation was needed and the process was fairly simple.

    Release date: Export PDF Favorites Scan
  • Hepatic alveolar echinococcosis and primary liver cancer: differential diagnosis with contrast-enhanced ultrasound

    Objective To determine the value of contrast-enhanced ultrasound (CEUS) in the differentiation of primary liver cancer (PLC) and hepatic alveolar echinococcosis (HAE). Methods The data of 56 patients with PLC or HAE were collected between January 2010 and May 2015. Grayscale and CEUS features of the patients were analyzed retrospectively. The frequency of each imaging finding, including calcification, arterial enhancement, and internal enhancement were evaluated and compared. Results Statistically significant difference of the proportion of gender and age were detected between the two groups (P=0.013, 0.002). Thirty-eight PLC lesions were detected in 32 patients. The diameters of PLC lesions were 3-10 cm with an average of (5.6±2.1) cm. Thirty-two HAE lesions were found in 24 patients. The diameters of HAE lesions were 4-12 cm with an average of (9.1±4.4) cm. Statistically significant difference of lesion size and the incidence rate of calcification (5.3% vs. 75.0%) were seen between PLC and HAE (P<0.001). Peripheral enhancement were seen in 100.0% (38/38) PLC lesions, including 84.2% (32/38) hyperenhancement and 15.8% (6/38) dendritic hyperenhancement. All PLC lesions demonstrated hypoenhancement in late phase. Irregular peripherally hyperenhancement both in arterial and late phase were detected in 43.8% (14/32) HAE lesions. The other 56.2% (18/32) HAE lesions showed no peripheral enhancement both in arterial and late phase. No internal enhancement were seen in HAE lesions. The presence of arterial enhancement (100.0% vs. 43.8%) and absence of internal enhancement (0 vs. 100.0%) were significantly different between PLC and HAE (P<0.001). Conclusions PLC is predicted by arterial phase hyperenhancement and late phase hypoenhancement on CEUS. HAE is predicted with calcification on baseline sonography and internal non-enhancement on CEUS. Arterial phase enhancement is less common and less intensive in HAE than in PLC which also contributes to the differentiation of these lesions.

    Release date:2017-07-21 03:43 Export PDF Favorites Scan
  • Ultrasonic microbubble combined with bevacizumab injection for choroidal neovascularization induced by phtocoagulation in rabbits

    Objective  To observe the therapeutic effect of ultrasonic microbubble combined with bevacizumab (Avastin) on choroidal neovascularization induced by photocoagulation in rabbits.Methods CNV was induced by photocoagulation with argon laser in 30 rabbits (60 eyes).All of the rabbits underwent fundus fluorecein angiography (FFA) 21 days after photocoagulation; 6-8 hours later, 3 rabbits were randomly chosen to be executed to having the immunohistochemical examination.Twenty one days after photocoagulation, 27 rabbits were divided randomly into 3 groups: bevacizumb, ultrasonic microbubble + bevacizumb,and control group; each group has 9 rabbits (18 eyes).The rabbits in control group had no interference treatment; while the rats in bevacizumb and ultrasonic microbubble + bevacizumb group underwent injection with bevacizumb or ultrasonic microbubble + bevacizumb respectively.FFA was performed on all of the rabbits 7,14,and 28 days after photocoagulation to observe the inhibition of CNV; immunofluorecence and Western blot were used to detect the expression of VEGF in retina and choroid.Twentyeight days is the time point to determine the therapeutic efficacy. The expression of VEGF and the results of FFA were the sdandards of the judgement of therapeutic efficacy.Results Proliferaion of CNV to the retinal inner layer and the obvious leakage of fluoresein in the photocoagulation area indicated that the model of CNV was set up successfully. Twenty eight days after injection,obvious fluorescent leakage was found in the control group, and the average fluorescent leakage in bevacizumab group differed much from the control group(t=16.2952,Plt;0.05); while the difference between ultrasonic microbubble + bevacizumb group and bevacizumab group was also significant (t=4.7955,Plt;0.05) . At the same time point, the expression of VEGF in bevacizumab group detected by immunofluorecent assay and Western blot differed much from the control group (t=7.0327,9.2596;Plt;0.05),and the difference of VEGF between ultrasonic microbubble + bevacizumb group and bevacizumab group was significant(t=2.9724,17.1937;Plt;0.05). this experiment show that ultrasound combined bevacizumab intravitreal injection of the therapeutic effect of CNV superior to other groups(Plt;0.01).Conclusion Ultrasound microbubble combined with bevacizumab injection may improve the therapeutic effect on CNV by inhibiting the expression of VEGF.

    Release date:2016-09-02 05:40 Export PDF Favorites Scan
  • Ultrasound microbubbles enhancing the transfection of recombinant adeno associated virus vector to retinal ganglion cells in vivo

    Objective To investigate the enhancing effect of ultrasound microbubbles on transfection of recombinant adenoassociated virus (rAAV) mediated green fluorecent protein (EGFP) gene into retinal ganglion cells (RGC) in vivo.Methods A total of 40 adult Sprague-Dawley (SD) rats were divided into four groups randomly (group A,B,C,D) with 10 rats in each. Group A was the normal control, in which the rats underwent intravitreal injection with 5 mu;l phosphate buffered solution. The rats in group B underwent intravitreal injection with 5 mu;l recombinant adenoassociated virus encoding EGFP gene (rAAV2-EGFP). The rats in group C underwent ultrasound irradiation on eyes right after intravitreal injection with 5 mu;l rAAV2-EGFP; The ultrasound irradiation was performed on the rats in group D right after intravitreal injection with the mixture solution of microbubbles and rAAV2-EGFP ultrasound. After 21 days, RGC were labeled retogradely with fluogold. Seven days after labeling, the retinal flatmounts and frozen sections were made from five rats in each group. Expression of EGFP reporter gene was observed by laser scanning confocal microscope and evaluated via average optical intensity (AOD) and RGC transfection rate. Labeled RGC were counted to evaluate the adverse effects.Results Green fluorescence can be observed exactly in labeled RGC in B,C,and D groups. The AOD and transfection rate in group D was (95.02plusmn;7.25)% and(20.10plusmn;0.74)% , respectively; which were higher than those in group B and C (F=25.970,25.799;P<0.01). The difference of the number of RGC among the four groups was not significant(F=0.877,P>0.05). Conclusion  Under the condition of low frequency and with certain energy, ultrasoundmediated microbubble destruction can effectively and safely enhance rAAV delivery to RGC in rats.

    Release date:2016-09-02 05:41 Export PDF Favorites Scan
  • 口服补钙药物导致造影剂残留样影像学改变一例

    Release date: Export PDF Favorites Scan
  • 非离子型造影剂在间接淋巴管造影中的临床应用

    自1989年以来,应用新一代非离子型、二聚体x线造影剂—Isovist(300),对各种不同病因的肢体淋巴水肿患者,进行间接淋巴管造影术。Isovist(300)是一种与血液、脑脊液等渗的高浓度造影剂。具有极低的理化毒性,良好的局部组织耐受性等优点。应用于临床肢体淋巴系统阻塞性疾病的形态学诊断时,操作简便、无副作用。对淋巴管无化学性损伤,可以反复进行淋巴管造影术。

    Release date:2016-09-01 11:17 Export PDF Favorites Scan
  • Study of Portal Vein Tumor Thrombus and Portal Vein Thrombosis with Contrast-Enhanced Ultrasonograph

    目的 探讨超声造影对门静脉癌栓和血栓的鉴别诊断价值。方法 应用超声造影剂(SonoVue)对16例门静脉癌栓及8例门静脉血栓行实时低机械指数超声造影,观察并分析其造影增强特征。 结果 16例癌栓超声造影动脉相10例呈整体均匀性增强,2例呈整体不均匀性增强,2例呈整体轻度增强,2例栓子一部分增强,另一部分无增强; 门脉相特别是门脉相晚期和延迟相14例栓子呈充盈缺损状态,2例栓子仍呈轻微强化。4例常规彩超检查未能检出动脉血流信号而不能确诊的癌栓,超声造影均显示其动脉相增强。8例血栓行超声造影后整个造影过程栓子均未见增强。结论 超声造影可敏感地反映门静脉栓子的血流灌注,门静脉癌栓和血栓在超声造影后有显著的特征,有助于两者的鉴别诊断。

    Release date:2016-09-08 11:07 Export PDF Favorites Scan
  • Efficacy of Treatment on Liver Metastases by Contrast Enhanced Ultrasonography-Guided Percutaneous Radiofrequency Ablation

    ObjectiveTo evaluate the clinical application and the efficacy of contrast enhanced ultrasonography (CEUS)guided percutaneous radiofrequency ablation (RFA) in patients with liver metastases. MethodsTotal 136 patients with 219 liver metastatic tumors, which were detected by CEUS before RFA therapy, were analyzed retrospectively. The diamter of tumors was (3.2±1.2) cm. Among them, the largest tumor more than 3 cm in diameter were found in 48.5% (66 patients), and 57.4% (78 patients) were with solitary metastasis. Enhanced CT and (or) MRI, and laboratory tests were applied to evaluate the outcomes after RFA treatment by regular followup. ResultsTumors were not detected by conventional ultrasonography in two cases, and 47.0% (63/134) of the patients with the largest tumor were 0.3 cm larger by CEUS than by conventional ultrasonography. More 40 tumors were detected in 18.4% (25/136) patients by CEUS. Followup ranged from 3 to 68 months (median time of 12 months). Early tumor necrosis rate one month after therapy was 98.2% (215/219 tumors). The incidence of local recurrence, new intrahepatic metastasis, and extrahepatic metastasis was 16.9% (23/136), 38.2% (52/136), and 8.8% (12/136), respectively. Local recurrence and new intrahepatic metastasis happened 2-25 months (median time of 6 months) after treatment. Local recurrence rates of the largest tumors ≥ 3 cm and tumor lt; 3 cm was 22.7% and 11.4%, respectively (P=0.079). The rate of new intrahepatic metastasis for the solitary metastasis cases was significantly lower than that for multiple metastases cases (25.6% versus 55.2%, P=0.000). The 1, 2, 3year survival rates were 82.5%, 64.3%, and 50.1%, and the 1, 2, 3year local recurrence free survival rates were 67.7%, 53.8%, and 38.3%, respetively. Patients with solitary metastasis survived longer than that with multiple metastases (P=0.034). ConclusionPatients with liver metastases treated by CEUSguided percutaneous RFA can get better survival rate, and CEUS is of much value for clinic application.

    Release date:2016-09-08 10:40 Export PDF Favorites Scan
  • Intraoperative ultrasound during endovascular aneurysm repair for infrarenal aortic aneurysms with internal iliac artery aneurysm

    Objective To discuss feasibility and effectivity of intraoperative ultrasound (US) during endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm. Methods A radiographic contrast nephropathy patient of abdominal aortic aneurysm and left internal iliac artery aneurysm was treated by EVAR without iodine contrast media assisted by US. Then summarized the data of this patient. Results The precise placement of the stent-graft was performed for abdominal aortic aneurysm. The left internal iliac artery aneurysm was successfully treatment with the stent-graft and coils. Intraoperative Ⅱ type endoleak from inferior mesenteric artery and Ⅰ b type endoleak from right iliac stent were identified by using US. The operative duration was 120 min and the blood loss was only 20 mL. Ⅱ type endoleak was still detected and the Ⅰ b type of endoleak was loss on postoperative a week. Conclusion Intraoperative US-assisted EVAR in patients with infrarenal abdominal aortic aneurysm represents a new option for intraoperative visualization of aortoiliac segments required as proximal or distal fixation zones and identification of endoleaks, especially in those patients with contraindications for usage of iodine-containing contrast agents.

    Release date:2018-06-15 10:49 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content