ObjectiveTo summarize the application and experience of repairing spontaneous Achilles tendon rupture by part-Kessler technique with suture anchor. MethodsBetween January 2011 and December 2013, 31 patients with spontaneous Achilles tendon rupture were treated by part-Kessler technique with suture anchor. Of 31 cases, 23 were male and 8 were female, aged 16-53 years (mean, 38 years). The left side was involved in 15 cases and the right side in 16 cases. The causes of injury included sudden heel pain and walking weakness during sports in 22 cases; no surefooted down-stairs, slip, and carrying heavy loads in 9 cases. The distance from broken site to the calcaneus adhension of Achilles tendon was 3-6 cm (mean, 4.2 cm). The time from injury to operation was 7 hours to 4 days (mean, 36.8 hours). ResultsAll incisions healed by first intention without nerve injury or adhering with skin. The patients were followed up 6-24 months (mean, 15 months). All patients could complete 25 times heel raising without difficulty at 6 months after operation. No Achilles tendon rupture occurred again during follow-up. At 6 months after operation, the range of motion of the ankle joint in dorsiflexion and plantar flexion showed no significant difference between normal and affected sides (t=0.648, P=0.525; t=0.524, P=0.605). The circumference of the affected leg was significantly smaller than that of normal leg at 6 months after operation (t=2.074, P=0.041), but no significant difference was found between affected and normal sides at 12 months after operation (t=0.905, P=0.426). The American Orthopedic Foot and Ankle Society (AOFAS) scores at 6, 12, 18, and 24 months after operation were significantly higher than preoperative score (P<0.05); the score at 6 months after operation was significantly lower than that at other time points (P<0.05), but no significant difference was shown between the other time points (P>0.05). ConclusionRepairing spontaneous Achilles tendon rupture by part-Kessler technique with suture anchor can supply strong strain and decrease the shear forces of suture. So part-Kessler technique with suture anchor is successful in repairing spontaneous Achilles tendon rupture.
Objective To investigate the outcomes of arthroscopic reduction and internal fixation of tibial eminence avulsion fracture using absorbable double suture anchors. Methods Between February 2007 and August 2009, 18 patients with tibial eminence avulsion fracture were treated with arthroscopic reduction and fixation using absorbable doublensuture anchors. There were 12 males and 6 females with an average age of 30.6 years (range, 17-48 years). The disease causes were traffic accident injury in 4 cases, sport injury in 8 cases, and fall ing from height injury in 6 cases; the locations were left side in 7 cases and right side in 11 cases. The results of the anterior drawer test and Lachman test were positive. According to Meyers-McKeever classification, 10 cases were rated as type II, 7 as type III, and 1 as type IV fractures. The time from injury to treatment was 6-20 days (mean, 10.2 days). Results Incision healed primarily. All the patients were followed up 29.1 months (range, 13-43 months). The X-ray films showed good reduction of fracture immediately after operation and fracture heal ing at 3 months. At the last follow-up, the range of motion of knee was 0-130°. The results of Lachman test and anterior drawer test were negative in 18 cases and 16 cases, repectively; and the results of anterior drawer test were weakly positive in 2 cases. The mean Lysholm score was significantly improved from 53.9 ± 6.7 preoperatively to 91.6 ± 4.2 postoperatively (t=22.100, P=0.000). The Inter national knee Documentation Commitee (IKDC) 2000 subject score improved from 58.1 ± 3.7 preoperatively to 92.8 ± 5.9 postoperatively (t=20.700, P=0.000). Conclusion Arthroscopic treatment using absorbable double suture anchors for tibial eminence avulsion fracture can provide satisfactory reduction, stable fixation, and good heal ing of the avulsed fragment, which is a minimally-invasive, simple, and effective treatment for patients with tibial eminence avulsion fracture.
Objective To explore the mid-term effectiveness of combined knee extensor mechanism realignment with bone anchor for recurrent patella dislocation. Methods Between August 2017 and May 2019, 21 patients with recurrent patella dislocation underwent combined knee extensor mechanism realigament with bone anchor and followed up more than 3 years. There were 8 males and 13 females with an average age of 19.4 years (range, 13-26 years). All 21 patients had a history of recurrent patellar dislocation for 2-5 times (median, 3 times), and the disease duration was 1-16 years (mean, 5 years). The preoperative Lysholm score was 67.5±6.3 and the Kujula score was 64.1±7.0. The defect of meniscus, anterior and posterior cruciate ligaments, and medial and lateral collateral ligaments were excluded by MRI examination; CT examination showed that the tibial tuberosity-trochlear groove distance was 2.05-2.56 cm, with an average of 2.16 cm; X-ray examination showed that lower limb force line was abnormal. The effectiveness were evaluated by Lysholm score and Kujula score before operation and at 3 years after operation, and Insall evaluation standard at 3 years after operation. Results All the incisions healed by first intention, and there was no surgical complication such as lower extremity deep vein thrombosis, incision infection, and nerve injury. All 21 patients were followed up 3.0-3.5 years, with an average of 3.2 years. Anteroposterior and lateral X-ray films of the knee joint at 3 years after operation showed that the position of the patella was normal, and the axial X-ray films of the patella (30°, 60°, 90°) showed that the patellofemoral joint had a good relationship. During the follow-up, there was no anchor drop or fracture, no obvious pseudarthrosis formation, and no epiphyseal injury in the minor patients. The Lysholm score was 91.5±7.1 and the Kujula score was 88.1±7.6 at 3 years after operation, which were significantly improved when compared with those before operation (t=11.57, P=0.00; t=12.78, P=0.00). According to the Insall evaluation criteria, 12 cases were excellent, 4 cases were good, 4 cases were fair, and 1 case was poor, with an excellent and good rate of 76.2%. ConclusionCombined knee extensor mechanism realignment with bone anchor is a simple and reliable way to treat the recurrent patella dislocation, with a satisfactory mid-term effectiveness and less complications; however, its long-term effectiveness needs further follow-up.
Objective To investigate the methods and effectiveness of surgical treatment for posteromedial corner (PMC) injury combined with anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) ruptures. Methods Between February 2009 and February 2012, 15 patients (15 knees) with PMC injury combined with ACL and PCL ruptures underwent PMC repair with suture anchor and ACL and PCL reconstruction. There were 7 males and 8 females with an average age of 39 years (range, 15-59 years). The causes of injury were traffic accident injury in 6 cases, sport injury in 7 cases, and sprain injury in 2 cases. The disease duration was 3-15 days with an average of 7 days. All patients presented positive results of anterior drawer test, posterior drawer test and valgus stress test, and dysfunction of knee joint. Of 15 cases, 3 had ACL and PCL ruptures, 5 had ACL rupture, 3 had ACL injury at the attachment point of the condyles crest, and 4 had PCL rupture; 9 had PMC tear at the femur insertion, 5 had PMC tear at the tibia insertion, and 1 had PMC tear in the body area. Results All incisions healed by first intention with no complication of infection or stiffness of knee. All cases were followed up 18.4 months on average (range, 10-36 months). At last follow-up, 14 cases had normal knee flexion and extension ranges, but 1 case had 10° limitation of the knee extension. Except 1 case which had weakly positive valgus stress test, the other patients showed negative results of anterior drawer test, posterior drawer test, and valgus stress test. Based on the improved Lysholm classification standard, the results were excellent in 8 cases, good in 5 cases, and fair in 2 cases; the excellent and good rate was 86.7%. Conclusion Early repair of the PMC and reasonable reconstruction of cruciate ligament can effectively restore the knee stability for patients with PMC injury combined with ACL and PCL ruptures.
Objective To evaluate the therapeutic effect of open-door cervical expansive laminoplasty (ELP) with anchor fixation on flurosis cervical stenosis (FCS). Methods From February 2005 to February 2006, 20 patients with FCS underwent ELP using anchor fixation (group A) and 24 patients with FCS received ELP using conventional silk thread fixation (group B). In group A, there were 11 males and 9 females aged (58.0 ± 11.2) years old, the course of disease ranged from 6 months to 5 years, and the stenosis involved 3 vertebral levels in 3 cases, 4 levels in 8 cases, and 5 levels in 9 cases, andthe sagittal diameter of the cervical spinal canal was (7.30 ± 5.23) mm. While in group B, there were 11 males and 13 females aged (61.0 ± 9.1) years old, the course of disease ranged from 5 months to 5 years, the stenosis involved 3 vertebral levels in 5 cases, 4 levels in 10 cases, and 5 levels in 9 cases, and the sagittal diameter of the cervical spinal canal was (7.11 ± 4.92) mm. No significant differences were evident between two groups in terms of the general information (P gt; 0.05). Before operation and at 24 months after operation, the nerve function was assessed by JOA score, the axial symptom (AS) was evaluated using Chiba 12-point method, and the changes of cervical lordosis index (CLI) and cervical range of motion (CRM) were detected by imaging examination. Results All wounds healed by first intention. All patients were followed up for 24 months. JOA score: in group A, it was improved from 7.4 ± 1.5 before operation to 14.6 ± 2.1 at 24 months after operation with an improvement rate of 61% ± 3%; in group B, the score was increased from 7.1 ± 2.2 to 12.6 ± 2.5 with an improvement rate of 52% ± 5%; significant differences were evident in two groups between before and after operation, and between two groups in terms of the improvement rate (P lt; 0.05). AS score: in group A, it was improved from 6.2 ± 2.1 before operation to 10.8 ± 0.3 at 24 months after operation with an improvement rate of 74% ± 4%; in group B, the score was increased from 6.3 ± 1.9 to 8.8 ± 0.5 with an improvement rate of 39% ± 3%; significant differences were evident in two groups between before and after operation, and between two groups in terms of improvement rate (P lt; 0.05). X-ray films and CT scan at 24 months after operation displayed that there was no occurrence of “breakage of door spindle” or “re-close of door” in two groups, there was no occurrence of anchor loosing in group A, and the molding of the spinal canal was satisfactory in two groups. Preoperatively, the CLI was 11.9 ± 1.9 in group A and 11.3 ± 2.2 in group B and the CRM was (39.5 ± 2.4)° in group A and (40.2 ± 1.8)° in group B. While at 24 months after operation, the CLI was 9.5 ± 2.2 in group A and 8.2 ± 2.8 in group B, and the CRM was (30.6 ± 2.0)° in group A and (28.7 ± 2.4)° in group B, suggesting there was a significant decrease when compared with the preoperative value and group A was superior to group B (P lt; 0.05). The saggital diameter of the cervical spinal canal 24 months after operation was (13.17 ± 2.12) mm in group A and (12.89 ± 3.21) mm in group B, indicating there was a significant difference when compared with the preoperative value (P lt; 0.01). Conclusion Compared with conventional silk thread fixation, ELP using anchor fixation brings more stabil ity to vertebral lamina, less invasion to the posterior muscular-skeletal structure of the cervical spine, sl ight postoperative neck AS, andsatisfactory cl inical outcomes.
ObjectiveTo explore the effectiveness of non-absorbable suture or suture anchor fixation by anterior approach in the treatment of anteromedial facet fractures of the ulnar coronoid process. MethodsBetween February 2007 and February 2012,16 cases of anteromedial facet fractures of the ulnar coronoid process were treated with operation.There were 9 males and 7 females,aged 20-80 years (mean,43.5 years).The causes of injury were traffic accident injury in 7 cases,tumble injury in 5 cases,and falling injury from height in 4 cases.The time from injury to operation was 6.8 days on average (range,2-8 days).All cases had closed fractures.According to O'Driscoll classification,there were 4 cases of type Ⅱ a,7 cases of type Ⅱ b,and 5 cases of type Ⅱ c.Among 16 patients,7 had simple anteromedial facet fractures of the ulnar coronoid process,and 9 had associated injury,including terrible triad in 3,Monteggia fractures in 4,and olecranon fractures in 2.All fractures were fixed with non-absorbable suture in 10 cases,and with suture anchor in 6 cases.The Mayo Elbow Performance Score (MEPS),range of motion (ROM),and complications were used to assess the elbow function. ResultsThe incisions all healed by first intension,without neurovascular injury.Fifteen patients were followed up 10-48 months (mean,25.3 months).The X-ray films showed that all fractures healed,with the mean healing time of 17.5 weeks (range,11-30 weeks).At last follow-up,the mean MEPS score was 88.5(range,55-100);the results were excellent in 10 cases,good in 3 cases,fair in 1 case,and poor in 1 case,with an excellent and good rate of 86.7%.The mean ROM of flexion and extension was 118°(range,35-145°),and the mean ROM of forearm rotation was 138°(range,85-165°).One case had elbow instability,and 3 had slight pain.No heterotopic ossification and traumatic arthritis occurred during the follow-up. ConclusionThe anteromedial facet fractures of the ulnar coronoid process can be clearly exposed through anterior approach,and the fracture fixation using non-absorbable suture and suture anchor fixation usually can restore the elbow function.
Objective To study the short-term effectiveness of absorbable anchor in repairing of partial anterior cruciate ligament (ACL) rupture. Methods Between December 2013 and February 2015, 22 patients with partial ACL rupture were repaired with absorbable anchor under arthroscopy. There were 12 males and 10 females with an average age of 27.5 years (range, 20-44 years). The injury located at left knee in 8 cases and at right knee in 14 cases. The time from injury to admission ranged from 2 to 13 days (mean, 9.8 days). Sixteen partial ACL ruptures combined with meniscus injury. The effectiveness was assessed by Tegner score, Lysholm score, International Knee Documentation Committee (IKDC) score, visual analogue scale (VAS) score, and MRI, as well as knee laxity was evaluated by KT-1000. Results All incisions healed at stage Ⅰ without any complication. All patients were followed up 12 months. ACL rerupture did not occurred during follow-up. There was no significant difference in Tegner score, Lysholm score, and IKDC score between before injury and at 12 months after operation (P>0.05). And the median satisfaction VAS score was 9.5 (range, 9-10). The tibial anterior translation difference was 0.5 mm (range, 0-6 mm). MRI showed that the scarring and continuity of the ligament were rated as grade 1 in all patients. Conclusion Arthroscopic repairing by absorbable anchor is a feasible method for partial ACL rupture, with ideal knee function, good satisfaction, and satisfactory short-term effectiveness.
ObjectiveTo compare the effectiveness between micro-anchor repair and modified pull-out suture in the treatment of mallet fingers. MethodsBetween June 2010 and March 2011, 33 patients with mallet fingers were treated by micro-anchor repair method (n=18, group A) and by modified pull-out suture method in which the broken tendons were sutured with double metal needle Bunnell’s suture and a knot was tied palmarly (n=15, group B). There was no significant difference in age, gender, and disease duration between 2 groups (P gt; 0.05). ResultsThe operation time was (62.5 ± 3.1) minutes in group A and (65.0 ± 4.6) minutes in group B, showing no significant difference (t=1.85, P=0.07). The treatment expense in group A [(8 566.2 ± 135.0) yuan] was significantly higher than that in group B [(5 297.0 ± 183.5) yuan] (t=58.92, P=0.00). Incision infection occurred in 2 cases of group A and 1 case of group B; the other patients obtained healing of incision by first intention. Relapsed mallet finger was observed in 1 case of group B. All patients in 2 groups were followed up 12-21 months. According to the Crawford functional assessment system, the results were excellent in 5 cases, good in 10 cases, fair in 2 cases, and poor in 1 case at the last follow-up with an excellent and good rate of 83.3% in group A; the results were excellent in 4 cases, good in 9 cases, fair in 1 case, and poor in 1 case with an excellent and good rate of 86.7% in group B. There was no significant difference in the excellent and good rate between 2 groups (χ2=0.23, P=0.97). ConclusionBoth micro-anchor repair and modified pull-out suture are simple and effective methods in the treatment of mallet finger. But compared with micro-anchor repair, pull-out suture has lower expense.