目的探讨肝外型门静脉高压症的外科治疗经验。方法1993年1月至1999年12月,我科收治肝外型门静脉高压症42例,男19例,女23例,年龄8~58岁,平均24.6岁,经B超、动脉造影、脾静脉造影和术中探查,诊断为门静脉血栓形成34例,内脏动静脉瘘5例,终末支门静脉纤维化2例,肝动脉瘤压迫门静脉1例。根据病变不同,分别给予肠腔分流、脾肾分流、经导管溶栓及栓塞或动静脉瘘切除等治疗。结果术后2例死亡,并发肝脓肿1例,肠坏死1例,其余患者均获满意疗效。有31例随访5个月~6年无复发。结论肝外型门静脉高压症只要选择好合理的治疗方法,可获满意疗效,且远期效果良好。
From Oct. 1993 to Dec. 1995, nineteen refractory cases with varicosis and chronic ulcer of lower limb were treated. The average age of these patients was sixty-eight, the disease history was more than 20 years. The size of the ulcer of the leg ranged from the minimum of 10 cm x 8 cm to the maximum of 30 cm x 15 cm. All of them had once received saphenectomy and split skin graft without ulcer healing before they were admitted in our department. Both venography and ultrasonography showed superficial venous valve incompetence. The following comprehensive treatment was adopted. Firstly, myoplasty around popliteal vein was done. Secondly, phlebexairesis and phleborrhaphy were done for the variciform veins through minor incision. Then through debridement of the ulcer was performed. Delayed split skin graft was exerted one week later. The result showed that all the cases were successful: the ulcer was healed and there was no recurrence of varicosis.
Objective To investigate the effectiveness of repairing hallux metatarsophalangeal skin and soft tissue defect with medial flap with double blood supply system in elderly patients. Methods Between June 2011 and March 2012, 9 cases (9 toes) of skin and soft tissue defect at hallux metatarsophalangeal joint were treated with medial flap with double blood supply system. There were 7 males and 2 females, aged 60-70 years (mean, 65.4 years). Injury included crush injury in 5 cases, traffic accident injury in 4 cases. The interval of injury and operation ranged from 3 hours to 5 days (mean, 35 hours). The patients had bone or tendon exposure with pollution of wounds. The size of defects ranged from 2.0 cm × 1.5 cm to 2.5 cm × 2.0 cm. The size of flaps ranged from 2.0 cm × 1.7 cm to 3.0 cm × 2.2 cm. Medial dorsal nerves were anastomosed with toe nerves to recover flap sensation. The donor site was repaired with skin grafting. Results All 9 flaps and skin grafting survived completely, and primary healing of wounds were obtained. Nine patients were followed up 6-8 months (mean, 7 months). The colour, texture, and contour of the flaps were good. The two-point discrimination of the flaps was 12-16 mm (mean, 14 mm) at last follow-up. The patients could walk normally. No scar contracture formed at donor site. No wear occurred. Conclusion The medial flap with double blood supply system can be used to repair hallux metatarsophalangeal skin and soft tissue defect in elderly patients because the flap can be easily obtained, has good blood supply, and has no injury to the main artery and nerve.
Objective To investigate the clinical application of high-frequency color Doppler ultrasound (HFCDU) in detecting perforators in the deep adipose layers for harvesting super-thin anterolateral thigh flap (ALTF). Methods Between August 2019 and January 2023, 45 patients (46 sides) with skin and soft tissue defects in the foot and ankle were treated, including 29 males and 16 females, aged from 22 to 62 years, with an average of 46.7 years. The body mass index ranged from 19.6 to 36.2 kg/m2, with an average of 23.62 kg/m2. The causes of injury included traffic accident injury in 15 cases, heavy object crush injury in 20 cases, mechanical injury in 8 cases, heat crush injury in 1 case, and chronic infection in 1 case. There were 20 cases on the left side, 24 cases on the right side, and 1 case on both sides. After thorough debridement, the wound size ranged from 5 cm×4 cm to 17 cm×11 cm. All patients underwent free super-thin ALTF transplantation repair. HFCDU was used to detect the location of the perforators piercing the deep and superficial fascia, as well as the direction and branches of the perforators within the deep adipose layers before operation. According to the preoperative HFCDU findings, the dimensions of the super-thin ALTF ranged from 6 cm×4 cm to 18 cm×12 cm. The donor sites of the flaps were directly sutured. Results A total of 55 perforators were detected by HFCDU before operation, but 1 was not found during operation. During operation, a total of 56 perforators were found, and 2 perforators were not detected by HFCDU. The positive predictive value of HFCDU for identifying perforator vessels was 98.2%, and the sensitivity was 96.4%. Among the 54 perforators accurately located by HFCDU, the orientation of the perforators in the deep adipose layers was confirmed during operation. There were 21 perforators (38.9%) traveled laterally and inferiorly, 12 (22.2%) traveled medially and inferiorly, 14 (25.9%) traveled laterally and superiorly, 5 (9.3%) traveled medially and superiorly, and 2 (3.7%) ran almost vertically to the body surface. Among the 54 perforators accurately located by HFCDU, 35 were identified as type 1 perforators and 12 as type 2 perforators (HFCDU misidentified 7 type 2 perforators as type 1 perforators). The sensitivity of HFCDU in identifying type 1 perforators was 100%, with a positive predictive value of 83.3%. For type 2 perforators, the sensitivity was 63.2%, and the positive predictive value was 100%. The surgeries were successfully completed. The super-thin ALTF had a thickness ranging from 2 to 6 mm, with an average of 3.56 mm. All super-thin ALTF survived, however, 1 flap experienced a venous crisis at 1 day after operation, but it survived after emergency exploration and re-anastomosis of the veins; 1 flap developed venous crisis at 3 days after operation but survived after bleeding with several small incisions; 3 flaps had necrosis at the distal edge of the epidermis, which healed after undergoing dressing changes. All 45 patients were followed up 6-18 months (mean, 13.6 months). Three flaps required secondary defatting procedures, while the rest had the appropriate thickness, and the overall appearance was satisfactory. Conclusion Preoperative application of HFCDU to detect the perforator in the deep adipose layers can improve the success and safety of the procedure by facilitating the harvest of super-thin ALTF.