ObjectiveTo investigate the effectiveness of digital three-dimensional (3D) printing osteotomy guide plate assisted total knee arthroplasty (TKA) in treatment of knee osteoarthritis (KOA) patients with femoral internal implants. Methods The clinical data of 55 KOA patients who met the selection criteria between July 2021 and October 2023 were retrospectively analyzed. Among them, 26 cases combined with femoral implants were treated with digital 3D printing osteotomy guide plate assisted TKA (guide plate group), and 29 cases were treated with conventional TKA (control group). There was no significant difference in gender, age, body mass index, side, Kellgren-Lawrence classification, preoperative visual analogue scale (VAS) score, Hospital for Special Surgery (HSS) knee score, knee range of motion, and other baseline data between the two groups (P>0.05). The operation time, intraoperative blood loss, incision length, postoperative first ambulation time, surgical complications; VAS score, knee HSS score, knee range of motion before operation, at 1 week and 3 months after operation, and at last follow-up; distal femoral lateral angle, proximal tibial medial angle, hip-knee-ankle angle and other imaging indicators at last follow-up were recorded and compared between the two groups. ResultsThe operation time, incision length, intraoperative blood loss, and postoperative first ambulation time in the guide plate group were significantly lower than those in the control group (P<0.05). In the control group, there were 1 case of incision rupture and bleeding and 1 case of lower limb intermuscular venous thrombosis, which was cured after symptomatic treatment. There was no complication such as neurovascular injury, incision infection, or knee prosthesis loosening in both groups. Patients in both groups were followed up 12-26 months, with an average of 16.25 months. The VAS score, HSS score, and knee range of motion improved at each time point after operation in both groups, and further improved with time after operation, the differences were significant (P<0.05). The above indicators in the guide plate group were significantly better than those in the control group at 1 week and 3 months after operation (P<0.05), and there was no significant difference between the two groups at last follow-up (P>0.05). At last follow-up, the distal femoral lateral angle, the proximal tibial medial angle, and the hip-knee-ankle angle in the guide plate group were significantly better than those in the control group (P<0.05). Conclusion The application of digital 3D printing osteotomy guide plate assisted TKA in the treatment of KOA patients with femoral implants can simplify the surgical procedures, overcome limitations of conventional osteotomy guides, reduce surgical trauma, achieve individualized and precise osteotomy, and effectively restore lower limb alignment and knee joint function.
Objective To investigate the construction of a novel tissue engineered meniscus scaffold based on low temperature deposition three-dimenisonal (3D) printing technology and evaluate its biocompatibility. Methods The fresh pig meniscus was decellularized by improved physicochemical method to obtain decellularized meniscus matrix homogenate. Gross observation, HE staining, and DAPI staining were used to observe the decellularization effect. Toluidine blue staining, safranin O staining, and sirius red staining were used to evaluate the retention of mucopolysaccharide and collagen. Then, the decellularized meniscus matrix bioink was prepared, and the new tissue engineered meniscus scaffold was prepared by low temperature deposition 3D printing technology. Scanning electron microscopy was used to observe the microstructure. After co-culture with adipose-derived stem cells, the cell compatibility of the scaffolds was observed by cell counting kit 8 (CCK-8), and the cell activity and morphology were observed by dead/live cell staining and cytoskeleton staining. The inflammatory cell infiltration and degradation of the scaffolds were evaluated by subcutaneous experiment in rats. Results The decellularized meniscus matrix homogenate appeared as a transparent gel. DAPI and histological staining showed that the immunogenic nucleic acids were effectively removed and the active components of mucopolysaccharide and collagen were remained. The new tissue engineered meniscus scaffolds was constructed by low temperature deposition 3D printing technology and it had macroporous-microporous microstructures under scanning electron microscopy. CCK-8 test showed that the scaffolds had good cell compatibility. Dead/live cell staining showed that the scaffold could effectively maintain cell viability (>90%). Cytoskeleton staining showed that the scaffolds were benefit for cell adhesion and spreading. After 1 week of subcutaneous implantation of the scaffolds in rats, there was a mild inflammatory response, but no significant inflammatory response was observed after 3 weeks, and the scaffolds gradually degraded. Conclusion The novel tissue engineered meniscus scaffold constructed by low temperature deposition 3D printing technology has a graded macroporous-microporous microstructure and good cytocompatibility, which is conducive to cell adhesion and growth, laying the foundation for the in vivo research of tissue engineered meniscus scaffolds in the next step.
ObjectiveTo review research progress on the design, manufacturing, and clinical application of three-dimensional (3D) printed customized prosthesis in acetabular reconstruction of hip revision surgery. MethodsThe related research literature on 3D printed customized prosthesis and its application in acetabular reconstruction of hip revision surgery was searched by key words of “3D printed customized prosthesis”, “revision hip arthroplasty”, “acetabular bone defect”, and “acetabular reconstruction” between January 2013 and May 2024 in Chinese and English databases, such as CNKI, Wanfang database, PubMed, etc. A total of 34 271 articles were included. After reading the literature titles, abstracts, or full texts, the literature of unrelated, repetitive, low-quality, and low evidence level was screened out, and a total of 48 articles were finally included for analysis and summary. ResultsThe bone growth and mechanical properties of 3D printed customized prosthesis materials are better than those of non-3D printed customized prosthesis, which further solves the problem of elastic modulus mismatch between the implant and natural bone caused by “stress shielding”; the porous structure and antibacterial coating on the surface of 3D printed customized prosthesis have good anti-bacterial effect. 3D printed customized prosthesis can perfectly match the patient’s individual acetabular anatomical characteristics and defect type, thus improving the accuracy of acetabular reconstruction and reducing the surgical time and trauma. Conclusion3D printed customized prosthesis can be used for precise and efficient individualized acetabular reconstruction in hip revision surgery with good early- and mid-term effectiveness. More optimized production technics and procedures need to be developed to improve the efficiency of clinical application and long-term effectiveness.
ObjectiveTo study the feasibility of preparation of the individualized femoral prosthesis through computer assisted design and electron beammelting rapid prototyping (EBM-RP) metal three-dimensional (3D) printing technology. MethodsOne adult male left femur specimen was used for scanning with 64-slice spiral CT; tomographic image data were imported into Mimics15.0 software to reconstruct femoral 3D model, then the 3D model of individualized femoral prosthesis was designed through UG8.0 software. Finally the 3D model data were imported into EBM-RP metal 3D printer to print the individualized sleeve. ResultsAccording to the 3D model of individualized prosthesis, customized sleeve was successfully prepared through the EBM-RP metal 3D printing technology, assembled with the standard handle component of SR modular femoral prosthesis to make the individualized femoral prosthesis. ConclusionCustomized femoral prosthesis accurately matching with metaphyseal cavity can be designed through the thin slice CT scanning and computer assisted design technology. Titanium alloy personalized prosthesis with complex 3D shape, pore surface, and good matching with metaphyseal cavity can be manufactured by the technology of EBM-RP metal 3D printing, and the technology has convenient, rapid, and accurate advantages.
Objective To investigate the effectiveness of using 3 hollow compression screws combined with 1 screw off-axis fixation under the guidance of three-dimensional (3D) printed guide plate with mortise-tenon joint structure (mortise-tenon joint plate) for the treatment of Pauwels type Ⅲ femoral neck fractures. Methods A clinical data of 78 patients with Pauwels type Ⅲ femoral neck fractures, who were admitted between August 2022 and August 2023 and met the selection criteria, was retrospectively analyzed. The operations were assisted with mortise-tenon joint plates in 26 cases (mortise-tenon joint plate group) and traditional guide plates in 28 cases (traditional plate group), and without guide plates in 24 cases (control group). There was no significant difference in the baseline data of gender, age, body mass index, cause of injury, and fracture side between groups (P>0.05). The operation time, intraoperative blood loss, frequency of intraoperative fluoroscopy, incision length, incidence of postoperative deep vein thrombosis of lower extremity, pain visual analogue scale (VAS) score at 1 week after operation, and Harris score of hip joint at 3 months after operation were recorded and compared. X-ray re-examination was taken to check the quality of fracture reduction, fracture healing, and the shortening length of the femoral neck at 3 months after operation, and the incidences of internal fixation failure and osteonecrosis of the femoral head during operation. Results Compared with the control group, the operation time, intraoperative blood loss, and frequency of intraoperative fluoroscopy reduced in the two plate groups, and the quality of fracture reduction was better, but the incision was longer, and the differences were significant (P<0.05). The operation time and intraoperative blood loss were significantly higher in the traditional plate group than in the mortise-tenon joint plate group (P<0.05), the incision was significantly longer (P<0.05); and the difference in fracture reduction quality and the frequency of intraoperative fluoroscopy was not significant between two plate groups (P>0.05). There was 1 case of deep vein thrombosis of lower extremity in the traditional plate group and 1 case in the control group, while there was no thrombosis in the mortise-tenon joint plate group. There was no significant difference in the incidence between groups (P>0.05). All patients were followed up 12-15 months (mean, 13 months). There was no significant difference in VAS score at 1 week and Harris score at 3 months between groups (P>0.05). Compared with the control group, the fracture healing time and the length of femoral neck shortening at 3 months after operation were significantly shorter in the two plate groups (P<0.05). There was no significant difference between the two plate groups (P>0.05). There was no significant difference in the incidences of non-union fractures, osteonecrosis of the femoral head, or internal fixation failure between groups (P>0.05). Conclusion For Pauwels type Ⅲ femoral neck fractures, the use of 3D printed guide plate assisted reduction and fixation can shorten the fracture healing time, reduce the incidence of postoperative complications, and be more conducive to the early functional exercise of the affected limb. Compared with the traditional guide plate, the mortise-tenon joint plate can reduce the intraoperative bleeding and shorten the operation time.
3D printing technology has a promising prospect of medical use and clinical value, and may play an important role in the field of thoracic and cardiovascular surgery, such as preoperative diagnosis, surgical planning, surgical approach alternatives and organ replacement. This review focuses on the development of 3D printing technology in recent years and its use and prospect in the field of thoracic and cardiovascular surgery including surgical teaching and simulation, personalized prosthesis implantation, and artificial organ transplantation.
Objective To analyze the short-term effectiveness and safety of personalized three-dimensional (3D) printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects. Methods A retrospective analysis was conducted on 8 patients with severe Paprosky type Ⅲ acetabular bone defects and met the selection criteria between January 2023 and June 2024. There were 3 males and 5 females, with an average age of 64.6 years ranged from 56 to 73 years. All primary replacement prostheses were non-cemented, including 1 ceramic-ceramic interface, 1 ceramic-polyethylene interface, and 6 metal-polyethylene interfaces. The time from the primary replacement to the revision was 4 days to 18 years. The reasons for revision were aseptic loosening in 5 cases, revision after exclusion in 2 cases, and repeated dislocation in 1 case. The preoperative Harris score was 39.5±3.7 and the visual analogue scale (VAS) score was 7.1±0.8. The operation time, intraoperative blood loss, hospital stay, and complications were recorded. The hip function was evaluated by Harris score, and the degree of pain was evaluated by VAS score. The acetabular cup abduction angle, anteversion angle, rotational center height, greater trochanter height, and femoral offset were measured on X-ray film. Results The operation time was 95-223 minutes, with an average of 151.13 minutes. The intraoperative blood loss was 600-3 500 mL, with an average of 1 250.00 mL. The hospital stay was 13-20 days, with an average of 16.88 days. All 8 patients were followed up 2-12 months, with an average of 6.4 months. One patient had poor wound healing after operation, which healed well after active symptomatic treatment. One patient had lower limb intermuscular vein thrombosis, but no thrombosis was found at last follow-up. No serious complications such as aseptic loosening, infection, dislocation, and periprosthetic fracture occurred during the follow-up. At last follow-up, the Harris score was 72.0±6.2 and the VAS score was 1.8±0.7, which were significantly different from those before operation (t=−12.011, P<0.001; t=16.595, P<0.001). On the second day after operation, the acetabular cup abduction angle ranged from 40° to 49°, with an average of 44.18°, and the acetabular cup anteversion angle ranged from 19° to 26°, with an average of 21.36°, which were within the “Lewinneck safety zone”. There was no significant difference in the rotational center height, greater trochanter height, and femoral offset between the healthy side and the affected side (P>0.05). ConclusionThe use of personalized 3D printed customized prostheses for the reconstruction of severe Paprosky type Ⅲ acetabular bone defects can alleviate pain and enhances hip joint function, and have good postoperative prosthesis position, without serious complications and have good safety.
ObjectiveTo study the effect of three-dimensional (3D) printed β-tricalcium phosphate (β-TCP) scaffold loaded poly (lactide-co-glycolide) (PLGA) anti-tuberculosis drug sustained release microspheres on osteogenic differentiation of bone marrow mesenchymal stem cells (BMSCs) and its cytotoxicity.MethodsIsoniazid and rifampicin/PLGA sustained release microspheres were prepared by W/O/W multiple emulsion method. The β-TCP scaffolds were prepared by 3D printing technique. The microspheres were loaded on the scaffolds by centrifugal oscillation method to prepare composite materials. The BMSCs of Sprague Dawley rat were isolated and cultured by whole bone marrow adherent method, and the third generation cells were used for the following experiments. BMSCs were co-cultured with osteogenic induction medium (group A), PLGA anti-tuberculosis drug sustained release microsphere extract (group B), 3D printed β-TCP scaffold extract (group C), and 3D printed β-TCP scaffold loaded PLGA anti-tuberculosis drug sustained release microsphere composite extract (group D), respectively. Cytotoxicity was detected by cell counting kit 8 (CCK-8) method; the calcium deposition was observed by alizarin red staining; and the mRNA expressions of alkaline phosphatase (ALP), osteocalcin (OCN), and bone sialoprotein (BSP) were detected by real-time fluorescence quantitative PCR (RT-qPCR).ResultsCCK-8 assay showed that the absorbance (A) value of groups A, B, C, and D increased gradually with the culture time prolonging. After cultured for 24, 48, and 72 hours, the A value decreased in the order of groups A, C, B, and D. There was no significant difference between groups B and D (P>0.05), but there were significant differences between other groups (P<0.05). The cytotoxicity was evaluated as grade 0-2, and the toxicity test was qualified. Alizarin red staining showed that red mineralized nodules were formed in all groups at 21 days after osteogenic induction, but the number of mineralized nodules decreased sequentially in groups C, D, A, and B. RT-qPCR test results showed that the relative expressions of OCN and BSP genes in groups A, B, C, and D increased gradually with the culture time prolonging. The relative expression of ALP gene increased at 7 and 14 days, and decreased at 21 days. After cultured for 7, 14, and 21 days, the relative expressions of ALP, OCN, and BSP genes decreased sequentially in groups C, D, A, and B; the differences were significant between groups at different time points (P<0.05).Conclusion3D printed β-TCP loaded PLGA anti-tuberculosis drug sustained release microsphere composites have no obvious cytotoxicity to BMSCs, and can promote BMSCs to differentiate into osteoblasts to a certain extent.