Objective To evaluate the short-term effectiveness of arthroscopic single-bundle reconstruction of anterior cruciate ligament (ACL) being centered within the native ligament’s tibial and femoral insertions with independent drilling of tibial and femoral tunnels. Methods Between September 2008 and September 2010, 33 patients with chronic ACL ruptures underwent arthroscopic reconstruction with four-stranded hamstring tendons in single-bundle. There were 19 males and 14 females, aged 22-33 years (mean, 26.4 years). Injuries were caused by traffic accident in 15 cases, by falling in 13 cases, and by sports in 5 cases. The location was the left knee in 20 cases and the right knee in 13 cases. The average time from injury to surgery was 6 months (range, 2-20 months). ACL reconstruction could be optimized when single-bundle grafts were centered within the native ligament’s tibial and femoral insertions with independent drilling of tibial and femoral tunnels. KT-1000 test, Lachman test, and pivot-shift test were used to evaluate the knee stability, and the International Knee Documentation Committee (IKDC) and Lysholm scores to assess the knee function. Results Primary healing of incision was obtained in all patients, who had no complications of intra-articular infection, deep venous thrombosis of the lower extremity, and injury of blood vessels and nerves. All the patients were followed up 18.6 months on average (range, 13-24 months). At 1 year after operation, the results of Lachman test were negative in 31 cases and I degree positive in 2 cases, showing significant difference when compared with preoperative results (I degree positive in 4, II degree positive in 26, and III degree positive in 3) (Z= — 5.42, P=0.00). The results of pivot-shift test were negative in 31 cases, I degree positive in 2 cases, showing significant difference when compared with preoperative results (I degree positive in 15 and II degree positive in 18) (Z= — 5.17, P=0.00). The KT-1000 results of examination (134 N) showed that the side difference of anterior laxity was (1.2 ± 0.7) mm at 25° flexion and (0.8 ± 0.6) mm at 70° flexion, showing significant differences when compared with preoperative ones [(7.8 ± 2.1) mm and (5.0 ± 1.8) mm] (t=16.19, P=0.00; t=13.28, P=0.00). The IKDC score was significantly increased from 39.6 ± 4.5 at preoperation to 95.1 ± 1.6 at postoperation (t= — 78.88, P=0.00), and Lysholm score was significantly increased from 48.3 ± 3.6 at preoperation to 92.0 ± 2.5 at postoperation (t= — 42.00, P=0.00). Conclusion It is a reliable procedure to restore the stability of the knee that arthroscopic single-bundle reconstruction of ACL is centered within the native ligament’s tibial and femoral insertions with independent drilling of tibial and femoral tunnels.
ObjectiveTo investigate the effectiveness of distraction therapy assisted by arthroscope in the treatment of ankle traumatic osteoarthritis. MethodsBetween October 2013 and October 2014, 13 patients with ankle traumatic osteoarthritis were treated, including 8 males and 5 females with an age range of 44-63 years (mean, 55.2 years). The left ankle and the right ankle were involved in 4 and 9 cases respectively. The disease duration was 1.5-10.0 years (median, 5 years). The American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hind foot scale score was 51.00±7.09; the short-form 36 health survey scale (SF-36) score was 40.82±4.62. According to Scranton grade system, 9 cases were rated as grade II and 4 cases as grade III. First, ankle hyperplasia osteophytes was removed under arthroscope, then Ilizarov apparatus was used to maintain distraction of 5-10 mm ankle space for 3 months. ResultsOne case had postoperative pin tract infection after removing the external fixation, and infection was controlled by dressing treatment; no related complications occurred in the other patients. All patients got follow-up of 12-18 months (mean, 14.7 months). Patients achieved disappearance of ankle swelling, pain relief, and were able to walk after rehabilitation. The ankle activity was obviously improved. At last follow-up, AOFAS ankel-hind foot scale score and SF-36 score were significantly increased to 85.23±6.41 and 56.29±6.20 respectively (t=20.756, P=0.025; t=11.647, P=0.018). According to AOFAS scores, the results were excellent in 4 cases, good in 8 cases, and fair in 1 case; the excellent and good rate was 92.3%. Postoperative X-ray film showed normal ankle position and alignment, osteophytes at the edges of the tibia and talus, articular surface sclerosis, normal joint space, and no joint swelling. ConclusionDistraction therapy assisted by arthroscope is an effective method for treating ankle traumatic osteoarthritis.
Objective To explore the technique of arthroscopic treatment of synovial chondromatosis of the hip and to evaluate its effectiveness. Methods Between July 2009 and June 2011, 15 patients with synovial chondromatosis of the hip underwent arthroscopic synovectomy and removal of loose bodier. Of 15 patients, 11 were male and 4 were female, aged from 21 to 45 years with an average of 33.1 years. The location was the left side in 6 cases and the right side in 9 cases. The disease duration was 12-43 months (mean, 23 months) Pain and functional motion limitation were the main clinical symptoms. The visual analogue scale (VAS) score was 5.8 ± 1.1; the range of motion (ROM) of the hip was (149.8 ± 27.5)°; the Harris hip score was 54.5 ± 13.3. Results All incisions healed by first intention. All the patients were followed up 6 months to 2 years (mean, 17.4 months). At last follow-up, the VAS score was 2.0 ± 1.2; the ROM of the hip was (258.3 ± 35.4)°; the Harris hip score was 93.0 ± 18.7; and the above indexes were significantly improved when compared with preoperative values (P lt; 0.05). No recurrence was found on postoperative MRI. Conclusion Arthroscopic treatment of synovial chondromatosis of the hip has the advantages of minimal invasion, quick recovery, and best recovery of hip function and ROM.
Objective To compare the recovery of proprioception between autograft and allograft for anterior cruciate l igament (ACL) reconstruction. Methods Between January 2008 and January 2010, 40 patients underwent ACL reconstruction with autologous tendon (autograft group, n=20) and allogeneic tendon (allograft group, n=20). No significant difference was found in gender, age, disease duration, and function scores between 2 groups (P gt; 0.05). All the patients underwent the ACL reconstruction with single-bundle technique. The knee range of motion (ROM), International Knee Documentation Committee (IKDC) score, and Lysholm score were measured after operation. The proprioception was assessedby the joint position sense (JPS) at 3 and 12 months postoperatively. The normal knee was used as control. Results Thepatients of 2 groups achieved heal ing of incision by first intention without compl ication of infection or haemarthrosis. Allpatients were followed up 12-18 months (mean, 13.5 months). There were significant differences in knee ROM, IKDC score, and Lysholm score between preoperation and 12 months postoperatively in 2 groups (P lt; 0.05). There was no significant difference in JPS 30°, JPS 60°, and JPS 90° between affected knees and normal knees in autograft group at 3 months postoperatively (P gt; 0.05). No significant difference was found in JPS 30° between affected knees and normal knees in allograft group at 3 months postoperatively (P gt; 0.05); but significant differences were found in JPS 60° and JPS 90° between affected knees and normal knees in allograft group at 3 months postoperatively (P lt; 0.05). There was no significant difference in JPS 30°, JPS 60°, and JPS 90° between affected knees and normal knees in 2 groups at 12 months postoperatively (P gt; 0.05). Significant differences were also found in JPS 60° and JPS 90° between affected knees of 2 groups (P lt; 0.05) at 3 months postoperatively, whereas no significant difference was found in JPS 30° between affected knees of 2 groups (P gt; 0.05). No significant difference was found in JPS 30°, JPS 60°, and JPS 90° between affected knees of 2 groups at 12 months postoperatively (P gt; 0.05). Conclusion Autologous andACL reconstruction is better than allogeneic ACL reconstruction in the recovery of proprioception at early time after surgery.
Objective To investigate the method and short-term effectiveness of arthroscopic reconstruction of anterior cruciate l igament (ACL) using RetroButton-allogeneic tendon-interference screw. Methods Between June 2009 and October 2009, 23 patients with ACL rupture were treated by arthroscopic reconstruction with RetroButton-allogeneic tendon-interference screw. There were 15 males and 8 females with an average age of 32.5 years (range, 19-46 years), including 17 left knees and 6 right knees. The injury causes were sport trauma (13 cases), traffic accident (8 cases), and fall ing injury(2 cases). There were 7 acute cases (lt; 6 weeks) and 16 chronic cases (gt; 6 weeks). Among the cases, 11 cases compl icated by medial meniscus injury, 6 by lateral meniscus injury, 3 by the both injuries, and 5 by articular cartilage injury. All cases had no injuries of posterior cruciate l igament, medial or lateral collateral l igament, or posterolateral structure. The time from injury to operation ranged from 3 weeks to 32 months. Lysholm and International Knee Documentation Committee (IKDC) scores were used for subjective evaluation, while Lachman test and KT-1000 measurement for objective evaluation. Results All wounds healed by first intention. The symptoms of unstable knee were improved obviously. No high fever, infection, or immunologic rejection were observed. Refractoriness synovitis and joint effusion occurred in 1 case after operation, and was improved after articular cavity flushing for 7 times within 3 weeks. All cases were followed up 10-17 months (mean, 14.7 months). There were significant differences in Lysholm score, IKDC score, Lachman test, and KT-1000 measurement between pre-operation and last follow-up (P lt; 0.05). Conclusion Arthroscopic reconstruction of ACL with RetroButton-allogeneic tendon-interferencescrew is simple and safe, and its short-term effectiveness is satisfactory.
【Abstract】 Objective When knee medial collateral ligament (MCL) rupture, the upper surface of medial meniscus is exposed totally, like the gulf panoramic, which is called “panoramic views of the bay sign” or the “bay sign”. To investigate the reliability and significance of the “bay sign” in diagnosis of knee MCL rupture under arthroscope. Methods Between March 2007 and March 2011, 127 patients with knees injuries were divided into the observation group (n=59) and control group (n=68) based on the MRI results. In the observation group, 59 patients had MCL rupture by MRI, including 12 cases of MCL injury alone, 16 cases of MCL injury with lateral meniscus torn, 27 cases of MCL injury with anterior cruciate ligament (ACL) injury, 3 cases of MCL injury with ACL and posterior cruciate ligament (PCL) injury, and 1 case of MCL injury with patellar dislocation; there were 38 males and 21 females with an average age of 23.2 years (range, 16-39 years). In the control group, 68 patients had no MCL rupture by MRI, including 38 cases of ACL injury, 4 cases of ACL and PCL injury, and 26 cases of ACL and lateral meniscus injury; there were 45 males and 23 females with an average age of 31.8 years (range, 25-49 years). The “bay sign” was observed under arthroscope in 2 groups before and after operation. Results The positive “bay sign” was seen under arthroscope in the patients of the observation group before MCL repair; the “bay sign” disappeared after repair. No “bay sign” was seen in patients of the control group before and after ACL reconstruction. Conclusion The “bay sign” is a reliable diagnostic evidence of MCL injury. It can be used as a basis to judge the success of MCL reconstruction during operation.
ObjectiveTo evaluate the technique and the effectiveness of arthroscopic fixation with percutaneous cannulated screws for acute displaced isolated greater tuberosity fractures of the proximal humerus. MethodsA retrospective analysis was made on the clinical data of 15 patients with acute displaced isolated greater tuberosity fractures of the proximal humerus, who accepted arthroscopic percutaneous cannulated screw fixation treatment between January 2010 and February 2013. There were 8 males and 7 females with an average age of 44.9 years (range, 31-66 years). Eight left shoulders and 7 right shoulders were affected. The mean interval of injury and operation was 9.9 days (range, 4-19 days). Before operation, the average range of motion (ROM) values of the affected shoulder were (74.13±17.19)° in forward flexion, (121.67±17.50)° in abduction, (T11±2)° in internal rotation, and (39.27±8.08)° in external rotation; the visual analogue scale (VAS) score was 6.46±1.30; and Costant score was 62.27±11.90. ResultsOperations were all successfully completed and incision healed by first intention in all cases. All cases were followed up 12-27 months (mean, 15 months). Postoperative X-ray films showed good reduction, alignment, and union of fracture. The average fracture healing time was 8 weeks (range, 6-13 weeks). At last follow-up, the ROM of the affected shoulder were significantly improved to (169.33±7.99)° in forward flexion, (156.67±10.47)° in abduction, (T6±2)° in internal rotation, and (71.67±7.94)° in external rotation (P<0.05); the VAS score was significantly reduced to 1.73±1.02 (t=-8.51, P=0.00); and the Costant score was significantly increased to 96.20±2.34 (t=11.50, P=0.00). No complication was found, such as neural or vascular injury, infection, shoulder joint adhesion, fixation failure, or fracture displacement. ConclusionArthroscopic fixation with percutaneous cannulated screws is a safe method to treat acute displaced isolated greater tuberosity fractures of the proximal humerus, and it has good short-term effectiveness with the advantages of little trauma and satisfactory functional recovery.
ObjectiveTo explorethe method and effectivenessofarthroscopically assisted treatmentof rotator cuff injury. MethodsBetween November 2009 and March 2011, 27 patients with rotator cuff injury were treated. There were 17 males and 10 females with a mean age of 43.6 years (range, 29-66 years). The disease duration was1 to 36 months (mean, 27months). The location was theleft shoulder in 11 cases and theright shoulder in 16 cases. Of them, 12 cases had a history of trauma and 15 caseshad no obvious predisposing causes. All patients had limitation of shoulder flexionandabduction. Anteroposterior and lateral X-ray films of the shoulder and the out-let X-ray films of the supraspinous muscle were taken. According to the acromion classification of Bigliani, there were 5 cases of type I, 13 cases of type II, and 9 cases of type III. MRI images showed all patients had rupture of the rotator cuff. The examination of shoulder arthroscope showed complete rupture of the supraspinatus muscle in 27 cases and acromion impingement in 23 cases. The patients without impingement underwent tear debridement, and the patients with impingement underwent acromioplasty and resection of subacromial bursa after tear debridement. The 3-4 cm incision was made with arthroscopically assisted positioning, and the metal suture anchorwas placed on the greater tubercle of humerus to repair rotator cuff. ResultsAll incisions healed primarily. All patients were followed up 13-27 months (mean, 19 months). No infection, loosening of internal fixation, and rotator cuffre-tearoccurred. Pain was relieved and the results was satisfactory after operation. The shoulder range of motion (ROM) at last follow-up was significantly improved when compared with preoperative ROM (P lt; 0.05). The visual analogue scale (VAS) score was significantly improved from 8.0 ± 1.8 at preoperation to 1.6 ± 0.7 at 2 weeks after operation and 0.8 ± 0.7 at last follow-up (Plt; 0.05); the University of California Los Angeles (UCLA) score of shoulder was significantly increased from 18.8 ± 6.6 at preoperation to 32.2 ± 3.3at 3months after operation and 33.6 ± 2.1 at last follow-up (P lt; 0.05). Conclusion The effectivenessofarthroscopically assisted treatmentof rotator cuff injury is satisfactory. However, long-termeffectiveness needs furtherfollow-up observation.
Objective To investigate the advantages and the clinical outcomes of the treatment of comminuted inferior femoral fractures with combination of supracondylar locked intramedullary nail and shape memory block hoop internal fixator under arthroscopy. Methods From June 2002 to December 2004, 12 cases of comminuted inferior femoral fractures were treated(9 males, 3 females). Of them, 5 cases were classified as type B and 7 cases as type C according to AO classification . All cases were treated with combination of supracondylar locked intramedullary nail and shape memory block hoop internal fixator under arthroscopy. In 12 cases of one-stage bone grafting, there 5 of autologous cancellous bone grafting and 7 allo-freeze drying bone grafting.Results With a follow-up of 6 to 18 months, all fractures healed within 3 to 6 months. There were no infection and nonunion. The function of all the knees joint was excellent. According to Noye’s criterion for knee scoring, the results were excellent in 9 cases and good in 3 cases; the excellent and good rate was 100%. Conclusion It is a good method to treat comminuted inferior femoral fractures with combination of supracondylar locked intramedullary nail and shape memory block hoop internal fixator under arthroscopy. It has many advantages of less injury to knee joint, good anatomic reduction and reliable fixation.
Objective The anterior cruciate l igament (ACL) is the important stable structure of the knee. To evaluate the method and outcome of bone-ACL-bone (B-ACL-B) allograft under arthroscope in reconstruction of ACL. Methods Between October 2007 and February 2010, arthroscopic ACL reconstruction with deep-freezing B-ACL-B allograft was performed on 22 patients with ACL ruptures. There were 15 males and 7 females with an average age of 27.6 years (range, 19-55 years). The causes of ACL rupture were sport trauma in 12 cases, fall ing injury in 1 case, heavy crush in 2 cases, and traffic accident in 7 cases. The locations were the left knee in 14 cases and the right knee in 8 cases. The disease durationwas 7 days to 12 months (median, 65 days). Nineteen patients showed the positive results of anterior drawer test and pivot shift test, and 21 patients showed the positive results of Lachman test. According to International Knee Documentation Committee (IKDC) criteria, there were 5 abnormal and 17 severely abnormal. The subjective IKDC score was 49.6 ± 6.9. The Lysholm score was 48.5 ± 5.3. The Tegner scale scores were 6.8 ± 1.2 before injury and 2.1 ± 0.5 before operation. The MRI showed the ACL injuries in 18 of 20 patients. Results The mean operative time was 75 minutes (range, 65-85 minutes); the mean blood loss was 110 mL (range, 80-150 mL). All incisions healed by first intention. No immunologic rejection and deep vein thrombosis of lower l imbs occurred. All patients were followed up 7-34 months (mean, 18 months). At last follow-up, the flexion of the knee ranged from 125 to 135° (mean, 130.5°). Two patients showed the positive results of anterior drawer test, 1 patient showed the positive result of pivot shift test, and 3 patients showed the positive results of Lachman test. According to the IKDC criteria, 10 patients rated as normal, 11 patients as nearly normal, 1 patient as abnormal. The subjective IKDC score was 90.0 ± 5.8, showing significant difference when compared with preoperative one (t=4.653, P=0.021). The Lysholm score was 91.6 ± 7.1, showing significant difference when compared with preoperative one (t=4.231, P=0.028). The Tegner scale score was 6.1 ± 1.5, showing no significant difference when compared with one before injury (t=1.321, P=0.070) and showing significant difference when compared preoperative one (t=3.815, P=0.033). The arthroscopic examination showed no rupture of grafts in 19 patients, 17 grafts showed normal tension, and 2 showed sl ight relaxation at 6 months after operation. Conclusion Reconstruction of the ACL with B-ACL-B allograft under arthroscope is a safe and effective method, which can anatomically reconstruct ACL and obtain a good recovery of the knee function after operation.