west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Augmentation" 3 results
  • A ANATOMIC SURVEY OF THE IMPLAN-TED PLANE OF IMPLANTATION ANDSTABILITY OF SILICONE NOSE IMPLANTIN AUGMENTATION RHINOPLASTY

    The noses of eight patients being dead for 2hours were dissected to investigate the layers andstructure of the nose, and the stability of theimplanted silicone noae prosthesis was tested.According to the structure and microstructure ofthe nose studied by us, we suggested a newconcept of nasal muscle and dorsal deepfasciacomplex. We confirmed the prcathesis should beimplanted in the space between the nasal boneand the complex. The reason for complicationhappened in this approach was that...

    Release date:2016-09-01 11:17 Export PDF Favorites Scan
  • ANALYSIS OF THE COMPLICATION ABOUT SILICONE GEL IMPLANTS IN AUGME NTATION MAMMAPLASTY

    Along with the wide application of silicone gel implants in augmentation mammaplasty, more complications appeared. The author reported 24 cases of complicationssince 1989, including one case of heamtoma, one case of infection, two cases of injury of the sensory nerves to the nipple, four cases of asymmetric breast (as ymmetry in position and size), three cases of deformed appearance, six cases of constracture of the fibrous coating membrane, one case of rupture of prosthesis,one case of sinus formation and three cases of abnormal milk secretion. The causes of the complications and their prevention were discussed.

    Release date:2016-09-01 11:16 Export PDF Favorites Scan
  • AN IN VITRO BIOMECHANICAL EVALUATION OF EFFECT OF AUGMENTATION PEDICLE SCREW FIXATION WITH POLYMETHYLMETHACRYLATE ON OSTEOPOROTIC SPINE STABILITY

    Objective To ascertain whether augmentation pedicle screw fixation with polymethylmethacrylate (PMMA) can enhance the stability of unstable thoracolumbar burst fractures of osteoporotic spine. Methods Six fresh frozen female osteoporotic spines (T10-L5) were harvested and an anterior and posterior columnunstable model of L1 was made. Each specimen was fixated with plate and the stability test were performed by flexion, extension, axial rotation and lateral bending. The test of fatigue was done with MTS 858.The tests were repeated after screws were augmented with PMMA. To compare the biomechanical stability of 6 different conditions:○anormal specimens(control), ○bdefectmodel fixed with plate, not augmented and not fatigued, ○cafter fatigued, not augmented, ○dscrews augmented with PMMA, not fatigued, ○e after augmented and fatigued. ResultsIn ○b,○d and ○e conditions, the ranges of motion(ROM) were 6.23±1.56,4.49±1.00,4.46±1.83 inflexion and 6.60±1.80,4.41±0.82,4.46±1.83 in extension. There was no significant difference (Pgt;0.05), they were significantly smaller than those in ○a and ○c conditions (8.75±1.88,1.47±2.25 and 8.92±2.97,12.24±3.08) (Plt;0.01).Conclusion The results demonstrated that augmentation pedicle screws fixation with PMMA can increase the stability of osteoporotic spine.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content