find Keyword "Bicuspid aortic valve" 19 results
  • Short and mid-term outcomes of valve repair in patients with insufficient bicuspid aortic valves

    ObjectiveTo evaluate the short and mid-term outcomes of valve repair in patients with insufficient bicuspid aortic valves (BAV).MethodsThe clinical data of 27 consecutive patients with insufficient BAV undergoing valve repair in Shanghai Chest Hospital from September 2016 to January 2020 were retrospectively reviewed. There were 24 males and 3 females with a mean age of 38.5±14.6 years (range: 20-68 years). BAV of all patients was type 1 in Seviers' classification. There were 23 patients with left-right fusion and 4 patients with right-noncoronary fusion. There was aortic regurgitation in the patients measured by the echocardiogram, including moderate regurgitation in 3 patients, moderate-severe in 18 patients, and severe in 6 patients. The diameter of aortic annular base was 27.9±3.4 mm, and the largest diameter of aortic sinus was 39.9±7.6 mm. Left ventricular end diastolic diameter was 62.7±6.5 mm, and the volume was 197.9±53.6 mL.ResultsAll 27 patients completed the follow-up, and the mean time was 24.2±12.5 months (range: 12-51 months). No patient died or required aortic valve-related reoperation during the follow-up. The cardiac function of the patients significantly improved postoperatively (P<0.05). By echocardiography, 11 patients had no aortic regurgitation, 13 had mild aortic regurgitation, and 3 had moderate aortic regurgitation, and no patient had severe aortic regurgitation. Postoperative left ventricular end diastolic diameter and volume decreased, compared to preoperative ones (P<0.05).ConclusionIn patients with insufficient BAV, valve repair is safe and effective, and has excellent short and mid-term outcomes.

    Release date:2021-12-27 11:31 Export PDF Favorites Scan
  • Application of reimplantation in the treatment of bicuspid aortic valve with aortic root aneurysm

    Objective To evaluate the early clinical effect of reimplantation in the treatment of bicuspid aortic valve (BAV) with aortic root aneurysm. Methods The clinical data of 25 patients with BAV and aortic root aneurysm[mean diameter: 45-63 (52.68±5.55) mm] undergoing reimplantation in West China Hospital from November 2019 to May 2021 were retrospectively reviewed. There were 22 males and 3 females. The mean age was 15-65 (50.00±13.10) years and body surface area was 1.79±0.23 m2. ResultsThe pathological classification of BAV malformation was confirmed during the operation: Type 0 in 3 patients and Type 1 in 22 patients. There were 12 patients undergoing cusp central plication, and 2 patients were sutured with a closed fusion crest. Postoperative valve leaflet coaptation height was 0.78±0.15 cm, and effective height was 1.27±0.19 cm. In operation, maximum aortic valve flow velocity was 1.65±0.42 m/s, pressure difference was 5.46±3.05 mm Hg, and aortic valve annulus diameter was 21.32±0.95 mm. Cardiopulmonary bypass time was 225.84±35.34 min, and aortic block time was 189.60±26.51 min. In-hospital time was 11.64±3.07 d, ICU stay time was 2.64±0.99 d, and mechanical ventilation time was 1.48±0.87 d. The follow-up time was 17.20±4.70 months, and no death or major complications occurred during the follow-up in all patients. The cardiac function of the patients significantly improved postoperatively (P≤0.05). Echocardiography suggested that 12 patients had no aortic regurgitation, 10 minor aortic regurgitation, 3 mild aortic regurgitation, and no patients with moderate or more severe regurgitation. The diameter of the aortic sinus, left ventricular end-diastolic diameter and volume decreased during the follow-up, compared to preoperative ones (P≤0.05). The maximum flow velocity of the aortic valve was 1.54±0.36 m/s, and the pressure difference was 5.17±2.38 mm Hg during the follow-up. ConclusionReimplantation technology has a good clinical effect for highly selective BAV patients. It can effectively avoid long-term postoperative anticoagulation, but the maximum flow rate after surgery is slightly increased, which may be related to the configuration of BAV itself. While compared with valve replacement, the effect is still worthy of recognition.

    Release date:2022-10-26 01:37 Export PDF Favorites Scan
  • Transcatheter aortic valve replacement for a patient with bicuspid aortic valve stenosis characterized by leaflet thickening: a case report

    Due to the lack of calcification of the aortic valve, it is difficult to provide effective support for the fixation of artificial valve in aortic stenosis characterized by leaflet thickening. There is a risk of postoperative perivalvular leakage and secondary valve implantation, which is widely regarded as a relative contraindication for transcatheter aortic valve replacement (TAVR). But aortic valvuloplasty and self-expanding transcatheter aortic valve has showed its safety and efficacy. This paper reports a patient with bicuspid aortic valve characterized by leaflet thickening treated with TAVR. After the operation, the patient’s symptom of exertional dyspnea was significantly improved, New York Heart Association class increased to Ⅱ, no perivalvular leakage was found, and the mean transaortic pressure gradient and the maximum aortic valve velocity decreased significantly.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan
  • A case report of transcatheter aortic valve replacement for horizontal heart with aortic stenosis

    A 78-year-old female patient was admitted to West China Hospital of Sichuan University because of “amaurosis and polypnea for 4+ years”. The examination results before admission showed that severe stenosis of aortic valve, bicuspid aortic valve malformation, severe horizontal heart with 61.54° aortic angle. The preoperative evaluation of the patient indicated that the Society of Thoracic Surgeons score was 17.9%, which was high risk for surgery. After discussion by the heart team, the aortic stenosis was finally relieved by transcatheter aortic valve replacement. The operation was successfully completed by using the method of pulling and releasing the device with the same side basket. One month follow-up showed that the patient’s condition was stable and no complications occurred. This case aims to provide a reference for the treatment of horizontal heart with aortic stenosis. In the future, it is hoped that through continuous clinical practice, such patients will be provided with a safer and more efficient treatment plan.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan
  • Predictive factors of new-onset conduction abnormalities after transcatheter aortic valve replacement in patients with bicuspid aortic valve: a meta-analysis

    ObjectiveTo systematically review the predictive factors of new-onset conduction abnormalities(NOCAs) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) patients. MethodsThe CNKI, VIP, WanFang Data, PubMed, Cochrane Library and EMbase databases were electronically searched to collect the relevant studies on NOCAs after TAVR in patients with BAV from inception to December 5, 2022. Two researchers independently screened the literature, extracted data, and assessed the risk of bias of the included studies. Meta-analysis was then performed by using RevMan 5.4 software. ResultsSix studies involving 758 patients with BAV were included. The results of the meta-analysis showed that age (MD=−1.48, 95%CI −2.73 to −0.23, P=0.02), chronic kidney disease (OR=0.14, 95%CI 0.06 to 0.34, P<0.01), preoperative left bundle branch block (LBBB) (OR=2.84, 95%CI 1.11 to 7.23, P=0.03), membranous septum length (MSL) (MD=0.93, 95%CI 0.05 to 1.80, P=0.04), implantation depth (ID) (MD=−2.06, 95%CI −2.96 to −1.16, P<0.01), the difference between MSL and ID (MD=3.05, 95%CI 1.92 to 4.18, P<0.01), and ID>MSL (OR=0.27, 95%CI 0.15 to 0.49, P<0.01) could be used as predictors of NOCAs. ConclusionCurrent evidence shows that age, chronic kidney disease, LBBB, MS, ID, the difference between MSL and ID, and ID>MSL could be used as predictors of NOCAs. Due to the limited quantity and quality of included studies, more high-quality studies are required to verify the above conclusion.

    Release date:2023-06-20 01:48 Export PDF Favorites Scan
  • The clinical effect of a combined technical system for bicuspid aortic valves repair

    ObjectiveTo summarize the clinical result of a combined technical system for bicuspid aortic valve (BAV) repair. MethodsPatients who diagnosed as BAV and sever aortic regurgitation (AR) underwent a strategy of combined repair technics including annuloplasty, sinus plasty, leaflet plasty, sinus-tubular junction (STJ) plasty depending on anatomy pathological characteristics between October 2019 and January 2021 were enrolled. The clinical data of the patients were analyzed.ResultsA total of 17 patients were enrolled. There were 11 males and 6 females with an average age of 18-49 (32.4±13.6) years. Fifteen patients had typeⅠand 2 patients had typeⅡBAV according to Sievers classification. Annuloplasty was applicated in 13 patients, sinus plasty in 8 patients, leaflet plasty in 17 patients, and STJ plasty in 11 patients, respectively. The cardiopulmonary bypass (CPB) time was 95 (84, 135) min, aortic cross-clamping time was 68 (57, 112) min, and the ICU stay time was 17 (12, 25) h. After the operation, mild AR was presented in 14 patients, moderate AR in 1 patient and severe AR in 2 patients. The latter 3 patients underwent second operation under CPB, after then, 1 patient had mild AR and 2 patients had moderate AR. The follow-up time was 13.1±4.6 months. At the latest follow-up, 12 patients had mild AR and 5 patients had moderate AR, and no patient had reoperation. ConclusionA combined technical system for BAV repair can be used effectively and safely with an acceptable short and middle-term result.

    Release date:2023-07-10 04:06 Export PDF Favorites Scan
  • Remodeling+Ring (modified Yacoub) technique for the treatment of bicuspid aortic valve regurgitation with ascending aortic aneurysm: A case report

    Patients with bicuspid aortic valve are often complicated with aortic dilatation. If the aortic valve is of good quality, aortic root replacement with aortic valve preservation is feasible. A 35-year-old male patient with bicuspid aortic regurgitation complicated with ascending aortic aneurysm underwent Remodeling+Ring (modified Yacoub) operation. Echocardiography showed that there was no aortic regurgitation on the 3rd day after operation, and the patient was discharged satisfactorily on the 6th day after operation. Remodeling+Ring surgery ensures the physiological movement of the aortic valve, solves the enlarged annulus, avoids the problems caused by valve replacement, and significantly improves the quality of life of patients, which is worth popularizing.

    Release date:2022-01-21 01:31 Export PDF Favorites Scan
  • Establishment of large animal model of bicuspid aortic valve

    ObjectiveTo discuss the feasibility of establishment of animal model of "functional" bicuspid aortic valve with swine and observe its effect on the wall shear stress inside the aorta. MethodsFour common Shanghai White Swine with body weight between 50 kg to 55 kg were selected. Under general anesthesia and cardiopulmonary bypass, the aortic transverse incision approach was used, continuous suture with 6-0 polypropylene to align the left and right coronary valve leaflets to create a bicuspid valve morphology. After the operation, echocardiography was used to observe the aortic valve morphology and the hemodynamic changes of the aortic valve orifice. The effect on the wall shear stress inside the aorta was studied with 4D-Flow magnetic resonance imaging (MRI). ResultsA total of 4 swine "functional" bicuspid aortic valve models were established, with a success rate of 100.0%. Echocardiography showed that the blood flow velocity of the aortic valve orifice was faster than that before the operation (0.96 m/s vs. 1.80 m/s). 4D-Flow MRI showed abnormally increased wall shear stress and blood flow velocity in the aorta of the animal models. After the surgery, in model animals, the maximal wall shear stress inside the ascending aorta was greater than 1.36 Pa, and the maximum blood flow velocity was greater than 1.4 m/s. ConclusionEstablishment of the animal model of "functional" bicuspid aortic valve in swine is feasible, scientific and reliable. It can be used in researches on evaluating the pathophysiological changes.

    Release date:2022-11-22 02:01 Export PDF Favorites Scan
  • Aortic Cusps Replacement with Bovine Pericardium for bicuspid aortic valve and Severe Aortic Regurgitation

    ObjectiveTo assess clinical results of aortic cusps replacement with bovine pericardium for bicuspid aortic valve (BAV) and severe aortic regurgitation (AR). MethodsClinical data of 79 patients with BAV and severe AR who underwent aortic cusps replacement with bovine pericardium in Wuhan Asia Heart Hospital from June 2008 to December 2013 were retrospectively analyzed. There were 60 male and 19 female patients with their age of 38±14 years (ranged 12-78 years). All the patients were in NYHA class Ⅱ. There were 26 patients with ascending aorta and sinotubular expanding. ResultsNo early death or major complication was recorded. Intraoperative transesophageal echocardiography showed successful repair with normal coaptation of the aortic leaflets in all the patients. AR grade was less than mild in all the patients with peak aortic valve pressure gradients of 14.2±2.8 mm Hg. All the patients were discharged from the hospital within 15 postoperative days without any adverse symptom, and were followed up for 50±16 months (ranged 9-64 months). During follow-up, all the patients were in NYHA classⅠ. There were 57 patients without AR, 16 patients with mild AR, 5 patients with moderate AR and 1 patients with severe AR. The peak of aortic valve pressure gradient was 12.4±3.2 mm Hg. The average diameter of ascending aorta was 2.7 cm in the patients with ascending aorta and sinotubular expanding. The shape of sinotubular kept normal. The height of coaptation of aortic valve was 0.58 cm by echocadiography. None of the patients died or required reoperation. The structural valve degeneration was not observed during the follow-up. ConclusionThree aortic cusps replacement with bovine pericardium can produce good hemodynamics and midterm results for patients with BAV and severe AR. The ascending aorta and sinotubular should be reduced and fixed in the patients with ascending aorta and sinotubular expanding.

    Release date: Export PDF Favorites Scan
  • Comparison of efficacy and safety of transcatheter aortic valve replacement in aortic stenosis patients with bicuspid versus tricuspid aortic valves

    Objective To compare the efficacy and safety of transcatheter aortic valve replacement (TAVR) in aortic stenosis patients with bicuspid aortic valve (BAV) versus tricuspid aortic valve (TAV). Methods This retrospective study included 252 consecutive patients with severe and symptomatic aortic valve stenosis undergoing TAVR in West China Hospital form April 2012 to September 2017, in whom 4 patients were excluded because of valve failure after surgical aortic valve replacement. Results Of the 248 patients, 131 had BAV and 117 had TAV. Baseline characteristics were similar between the two groups, including age [(73.56±6.35) vs. (74.31±6.35) years, P=0.354], male proportion (51.9% vs. 63.2%, P=0.072). Society of Thoracic Surgeons score for BAV patients was lower than that for TAV patients [(7.56±4.01)% vs. (8.78±5.14)%, P=0.037]. Procedural success rate was high in both BAV and TAV groups (95.4% vs. 98.3%, P=0.359). There was no difference in 30-day all-cause mortality (6.1% vs. 2.6%, P=0.176) between the two groups; the aortic valve maximum velocity of valve hemodynamics after TAVR was similiar [(2.39±0.53) vs. (2.31±0.45) m/s, P=0.262] between the two groups. Conclusions Patients with BAV show similar procedural and clinical outcomes to patients with TAV. Therefore, TAVR appears to be a safe and effective procedure for patients with BAV as well as those with TAV.

    Release date:2018-02-26 05:32 Export PDF Favorites Scan