A comparative study of four methods of laryngeal muscle reinnervation in dogs is presented. Twenty-eight cases were divided into four groups to undergo main branch and branch of ansa cervicalis nerve anastomosis, and nerves implantation an neuromuscular pedicles transfer respectively for restoration of vocal cord adduction on left sides. The results showed that the four procedures seemed to induce effective reinnervation of adductor muscles. But the main branch of ansa cervicalis nerve suture was superior to the other methods among which little difference was noted in the functional recovery, electrophysiological activity and muscle strength. It demonstrated that main branch of ansa nerve suture was the best procedure for treatment of unilateral vocal cord paralysis among the four methods.
Objective To evaluate the application of tendency-oriented perimetry (TOP) in detecting the visual function of glaucoma. Methods The traditional threshold perimetry (Normal/Normal strategy) and TOP (TOP/Normal strategy) carried out by Octopus 101 perimetry were used to examine the visual field of 20 normal subjects (20 eyes), 32 cases (32 eyes) of primary open-angle glaucoma (POAG), and 14 cases (14 eyes) of suspected POAG, respectively. The visual field outcomes, indices, point by point threshold variability and defective points of the two perimetries were compared and analysed. Results The negative rate of TOP was 90% in normal subjects. The positive rate of TOP was 75% in POAG , and 100% in middle and late stage of POAG. The visual field indices of two perimetries were positively correlated, with mean sensitivity (MS) of r=0.9335, mean defect (MD) of r=0.9189, and loss variance (LV) of r=0.9621. The point by point threshold variability and defective points of TOP were higher than those of traditional threshold perimetry, but the difference between the two perimetries was not significant (P=0.2019, P=0.4448). Conclusion The visual field indices of TOP and traditional threshold perimetry are positively correlated. The sensitivity and reproducibility of TOP are high in detecting the visual function of middle and late stage of POAG. (Chin J Ocul Fundus,Dis, 2002, 18: 269-272)
Purpose To evaluate the correlation of retinal thickness between optical coherence tomography (OCT) images and histologic slides . Methods Retinal thickness was measured in 16 rabbit retinal histologic slides.The same eyes were previously viewed by OCT for the comparison of results between two methods.Retinal thickness of each OCT image section was measured using both the manually assisted (requiring observer localization of reflectivity peaks) and the automated modes of the computer software. Results Retinal thickness as measured by OCT demonstrated a high degree of correlation with retinal histologic study.The automate d method (gamma;=0.66,P<0.01) was less reliable than the manually assisted one (gamma;=0.84,P<0.001).The former had an error in 95% confidence interval,ranged in-0.71~11.09 mu;m,the latter had a less error,ranged in-2.99~5.13mu;m. Conclusion Retinal thickness can be quantitatively measured by OCT examination.However,computer automatic identification of the reflective boundaries may result in errors in some cases.To measured the retinal thickness by manually assisted mode can increase the degree of accuracy. (Chin J Ocul Fundus Dis,2000,16:71-138)
Objective To evaluate the treatment results of LCP and locked intramedullary nailing for tibial diaphysis fractures.MethodsFrom October 2003 to April 2006, 55 patients with tibial diaphysis fractures ( 58 fractures) were treated. Of them there were 39 males and 16 females with an average of 39 years years ( 14 to 62 years). The fractures were on the left side in 27 patients and on the right side in 31 patients (3 patients had bilateral involvement). Thirtyfour fractures were treated by intramedullary nailing (intramedullary nailing group) and 24 fractures by LCP fixation (LCP group). The average disease course was 3 days (intramedullary nailing group) and 3.1 days(LCP group). The operation time, the range of motion of knee and ankle joints, fracturehealing time, and complications were evaluated. Results The patients were followed up 8-26 months(13 months on average). The operation time was 84.0±9.2 min (intramedullary nailing group) and 69.0±8.4 min (LCPgroup); the average cost in hospital was¥19 297.78 in the intramedullary nailing group and ¥14 116.55 in the LCP group respectively, showing significant differences(P<0.05). The flexion and extension of knee joint was 139.0±3.7° and 4.0±0.7° in intramedullary nailing group and 149.0±4.2° and 0±0.4° in LCP group, showing no significant difference(Pgt;0.05). The doral flexion and plantar flexion of ankle joint were 13.0±1.7° and 41.0±2.6° in intramedullary nailing group, and 10.0±1.4° and 44.0±2.3° in LCP group, showing nosignificant differences(Pgt;0.05). The mean healing time was 3.3 months in intramedullary nailing group, and 3.1 months in LCP group. Length discrepancy occurred in 1 case (2.5 cm), delayed union in 1 case and nailing endtrouble in 3 cases in intramedullary nailing group; moreover rotation deformityoccurred 1 case and anterior knee pain occurred in 6 cases(17.1%). One angulation and open fracture developed osteomyelitis in 1 case 1 week postoperatively and angulation deformity occurred in 1 case of distalthird tibial fractures in LCP group. Conclusion LCP and locked intramedullary nailing can achieve satisfactory results in treating tibial diaphysis fracture LCP has advantages in less complication, operation time and cost in hospital.
Objective To compare effects, advantages and disadvantages of simple internal fixation to that of l imited internal fixation with external supporting frame fixation in the treatment of complex fractures of tibial plateau. Methods From July 2002 to August 2006, 66 cases of complex fractures of the tibial plateau were divided into the internal fixation group (n=39) and the external fixator group (n=27). The interal fixation group had 18 cases of IV, 7 cases V and 14 cases VI according to Schatzker, including 25 males and 14 females aged 18-79 years with an average of 45.4 years. The external fixator group had 13 cases of IV, 6 cases V and 8 cases VI according to Schatzker, including 18 males and 9 femles aged 18-64 years with an average of 44.2 years. No significant difference was evident between the two groups (P gt; 0.05). Patients were treated by using screws, steel plates or external supporting frame fixation strictly based on the princi ple of internalfixation. Results All patients were followed up for 1-5 years. Fracture healed with no occurrence of nonunion. Two cases inthe internal fixation group presented partial skin infection and necrosis, and were cured through the dressing change and flap displacement. Fracture heal ing time was 6-14 months with an average of 7.3 months. The time of internal fixator removal was 6-15 months with an average of 8.3 months. In the external fixation group, 11 cases had nail treated fluid 7 days to 3 months after operation, combining with red local skin; 3 cases had skin necrosis; and 3 cases had loose bolts during follow-up. Through debridement, dressing change and flap displacement, the skin wounds healed. Fracture heal ing time was 3-11 months with an average of 5.1 months. The time of external fixator removal was 5-11 months with an average of 6.4 months. At 8-14 months after operation, the knee function was assessed according to Merchant criteria. In the internal fixation group, 29 cases were excellent, 4 good, 5 fair and 1 poor, while in the external fixation group, 20 cases were excellent, 3 good, 2 fair and 2 poor. There was no significant difference between the two groups (P gt; 0.05). Conclusion The therapeutic effects of simple internal fixation and l imited internal fixation with external supporting frame fixation were similar in the treatment of complex fractures of tibial plateau. Fixation materials should be selected according to the state of injury and bone conditions for the treatment of tibial plateau fracture of type IV, V and VI based on Sehatzker classification.
In order to understand the influence of the free tendon graft and the tendon transfer on their blood supply, histological and biochemical changes during healing following repair of the damaged tendon after the alteration of the nourishing environment, an experiment was carried on 36 New Zealand white rabbits. In the front paws of the rabbits, the free tendon graft was sutured in the tendon defect of flexor of the fourth toe and the flexor tendon of the third toe was transferred to the second toe to reconstr...
Objective To compare the short-term result between the high-flex (HF) and conventional posteriorstabil ized (PS) prosthesis in total knee arthroplasty (TKA). Methods From April 2005 to October 2007, 23 cases (27 knees) underwent TKA by HF prosthesis (HF group), and 35 cases (41 knees) underwent TKA by PS prosthesis (PS group).In HF group, there were 2 males (3 knees) and 21 females (24 knees) aged (64.3 ± 5.6) years, including 20 cases (23 knees) of osteoarthritis and 3 cases (4 knees) of rheumatoid arthritis; body mass index (BMI) was 27.3 ± 3.9; the course of disease was (5.3 ± 5.6) years; the Hospital for Special Surgery Scoring System (HSS) score was 58.4 ± 7.9; the Western Ontario and McMaster universities osteoarthritis index (WOMAC) score was 49.4 ± 6.9; the maximum knee flex degree was (107.6 ± 8.3)°; and the range of knee motion was (103.5 ± 7.7)°. In PS group, there were 3 males (3 knees) and 32 females (38 knees) aged (65.1 ± 5.9) years, including 33 cases (39 knees) of osteoarthritis and 2 cases (2 knees) of rheumatoid arthritis; BMI was 27.1 ± 4.1; the course of disease was (5.1 ± 4.9) years; HSS score was 60.1 ± 10.4; WOMAC score was 47.9 ± 7.2; the maximum knee flex degree was (108.4 ± 9.7)°; and the range of knee motion was (105.9 ± 11.4)°. There were no significant differences in general data between two groups (P gt; 0.05). Results All incisions achieved heal ing by first intention. No compl ication of ankylosis, blood vessel and nerve injuries, and prosthesis loosening occurred. All patients were followed up for 24-54 months (average 32.8 months). There were no significant differences in the HSS score, WOMAC score, the maximum knee flex degrees, and the range of knee motion at 3, 12, and 24 months after operation between two groups (P gt; 0.05), but there were significant differencesbetween pre- and post-operation (P lt; 0.05). Anterior knee pain occurred in 1 case of HF group and 4 cases of PS group after 24 months, the incidence rates were 3.70% in HF group and 9.76% in PS group, showing significant difference (P lt; 0.05). The X-ray films showed that no lucent zone around prosthesis and no patella baja were observed, and the force l ine was excellent. Conclusion There is no significant difference in the range of knee motion and cl inical scores between the HF prosthesis and the PS prosthesis, but the former’s incidence rate of anterior knee pain is lower.
Objective To evaluate the effect of self-designed antirotation reduction internal fixator(ARRIF) on treating different spine segment fracture.Methods From August 1999 to March 2003, 76 patients(48 males and 28 females, aged from 22 to 59 with an average of 34.1) with thoracolumbar fracture were operatively treated by ARRIF. The follow-up period ranged from 6 to 21 months(15 months in average). Classification according to injury segment: flexion compression racture 27 cases, burst fracture 42 cases, flexion distraction injury 3 cases, flexion revolving type fracture dislocation 2 cases, shear force type dislocation 2 cases. Classification according Frankel’s grade:A grade 16 cases, B grade 15 cases, C grade 27 cases, D grade 10 cases, E grade 8 cases.Operation duration, volume of bleeding, incidence postoperation complication and effect of reduction fixation were observed. Results The operation duration of ARRIF was 1.2 h in average, and there was about 200 ml volume of bleeding during operation. The nerve function showed one Frankel’s grade improvement after operation were as follows:A grade 8 cases(50%), B grade 11 cases (73.3%), C grade20 cases(74.1%), D grade 3 cases (30%); 2 Frankel’s E cases have no nerve function changes.The nerve function damage have no aggravation in all the patients,the postoperation Cobb’s angle was averagely corrected 22°. The horizontal displacement of dislocation vertebrae was averagely corrected 28% in sagittal plane, the statistical analysis had significant variance(Plt;0.01).ARRIF had no complications of the breakage of screws and rods. Conclusion ARRIF proves to be a valid internal fixator in reducing and fixing different thoracic lumbar segment spine fracture.
Objective To observe the biocompatibility of the acellular corneal stroma materials prepared by three different methods. Methods Three different serial digestion methods were used to produce the acellular corneal stroma materials. The biocompatibility of the materials was investigated by the cell seeding and the materials were implanted into the rabbit corneal stroma layer. Results The cells in the materials 1 and 2 were not decellularized completely. The rabbit corneal fibroblasts died on the materials 1 and 2 after the cell seeding for 3-4 days. An obvious rejection could be observed after the implantation. The cells in material 3 were decellularized completely and the collagen fibers or elastic fibers were reserved integrally,showing a typical three-dimensional net work. The rabbit corneal fibroblasts could expand on the materials in vitro. No obvious rejection could be observed and the materials were gradually absorbed. Conclusion The acellular porcine cornea stroma materials prepared by trypsin-Dnase-Rnase are suitable for reconstruction of the tissue engineered cornea.
Objective To evluate the clinical outcome of autograftsof ilium and interbody fusion cage or bone morphogenetic protein(BMP)/artificial bone material/ cage in treating lumbar spondylolisthesis. Methods From January 1997 to January 2004,114 patients with lumbar spondylolisthesis were treated with posterior lumbar interbody fusion and pedicle screw fixation. There were 45 males and 69 females with an average age of 43 years ranging from 32 to 61 years. Of 114patients, 85 cases were classified as degree Ⅰ, 24 cases as degree Ⅱ and 5 cases as degree Ⅲ. The patients were divided into three groups accordingto the material used for interbody fusion: autografts of ilium (group A, n=42), interbody fusion cages(group B, n=36), and BMP/artificial bone material/ cage (group C, n=36).The clinical and radiographic results of the patients were compared among three groups. Results All patients were followed from 13 to 30 months with an average of 15 months. There were no statistically significant differences in surgical time, blood loss, and disc space height of preoperation(P>0.05) among three groups. No severe complication occurred in the three groups(P>0.05). The excellent and good rates in groups A,B and C were 81.0%, 80.6%, and 83.3% respectively, showing no statisticallysignificant difference(P>0.05).The fusion rate of group C(97.0%) was significantly higher than those of group A(81.0%) and group B(83.3%) (P<0.05) after 1 year of operation.And the average loss of disc space height in groups B and C was significantly lower than that in group A(P<0.05). Conclusion Higher fusion rate and lower loss of disc space height can beobtained in treating lumbar spondylolisthesis with BMP/artificial bone materiel.It is an effective method in the treatment of spondylolisthesis.