Objective To investigate the clinical application of high-frequency color Doppler ultrasound (HFCDU) in detecting perforators in the deep adipose layers for harvesting super-thin anterolateral thigh flap (ALTF). Methods Between August 2019 and January 2023, 45 patients (46 sides) with skin and soft tissue defects in the foot and ankle were treated, including 29 males and 16 females, aged from 22 to 62 years, with an average of 46.7 years. The body mass index ranged from 19.6 to 36.2 kg/m2, with an average of 23.62 kg/m2. The causes of injury included traffic accident injury in 15 cases, heavy object crush injury in 20 cases, mechanical injury in 8 cases, heat crush injury in 1 case, and chronic infection in 1 case. There were 20 cases on the left side, 24 cases on the right side, and 1 case on both sides. After thorough debridement, the wound size ranged from 5 cm×4 cm to 17 cm×11 cm. All patients underwent free super-thin ALTF transplantation repair. HFCDU was used to detect the location of the perforators piercing the deep and superficial fascia, as well as the direction and branches of the perforators within the deep adipose layers before operation. According to the preoperative HFCDU findings, the dimensions of the super-thin ALTF ranged from 6 cm×4 cm to 18 cm×12 cm. The donor sites of the flaps were directly sutured. Results A total of 55 perforators were detected by HFCDU before operation, but 1 was not found during operation. During operation, a total of 56 perforators were found, and 2 perforators were not detected by HFCDU. The positive predictive value of HFCDU for identifying perforator vessels was 98.2%, and the sensitivity was 96.4%. Among the 54 perforators accurately located by HFCDU, the orientation of the perforators in the deep adipose layers was confirmed during operation. There were 21 perforators (38.9%) traveled laterally and inferiorly, 12 (22.2%) traveled medially and inferiorly, 14 (25.9%) traveled laterally and superiorly, 5 (9.3%) traveled medially and superiorly, and 2 (3.7%) ran almost vertically to the body surface. Among the 54 perforators accurately located by HFCDU, 35 were identified as type 1 perforators and 12 as type 2 perforators (HFCDU misidentified 7 type 2 perforators as type 1 perforators). The sensitivity of HFCDU in identifying type 1 perforators was 100%, with a positive predictive value of 83.3%. For type 2 perforators, the sensitivity was 63.2%, and the positive predictive value was 100%. The surgeries were successfully completed. The super-thin ALTF had a thickness ranging from 2 to 6 mm, with an average of 3.56 mm. All super-thin ALTF survived, however, 1 flap experienced a venous crisis at 1 day after operation, but it survived after emergency exploration and re-anastomosis of the veins; 1 flap developed venous crisis at 3 days after operation but survived after bleeding with several small incisions; 3 flaps had necrosis at the distal edge of the epidermis, which healed after undergoing dressing changes. All 45 patients were followed up 6-18 months (mean, 13.6 months). Three flaps required secondary defatting procedures, while the rest had the appropriate thickness, and the overall appearance was satisfactory. Conclusion Preoperative application of HFCDU to detect the perforator in the deep adipose layers can improve the success and safety of the procedure by facilitating the harvest of super-thin ALTF.
Objective To investigate theory guidance for preoperative appraisal of advanced stage lower limb arteriosclerosis obliterans and clinical application of arteriae surales. Methods From September 2007 to June 2008, one hundred cases without obviously arteriosclerosis were collected to accepted color Doppler ultrasonography, and parameters of the arteriae surales were observed, such as location, macro-body morphous, caliber, and blood parameters value, meanwhile the caliber and blood parameters value of anterior tibial artery and posterior tibial artery were also measured. Results Detection rate of arteriae surales was 96% (96/100). Arteriae surales located midpiece sequentiae of popliteal fossa, and above flatfish tendinous arch, which in 89 cases were geminous branched from popliteal artery; in the remaining 7 cases, popliteal artery diverged a bole, walked 1-3 cm, then diverged two branches and ingressed gastrocnemius. Diameter and cross section area of arteriae surales were smaller than those of anterior tibial artery and posterior tibial artery (P<0.05), but peak flow rate of systolic phase, maximum positive direction flow rate of relaxing period and mean flow rate were not significantly differents between arteriae surales and anterior tibial artery or posterior tibial artery (P>0.05). The flow of geminous arteriae surales was 63.1% of anterior tibial artery, and 59.1% of posterior tibial artery. Conclusion Through the ultrasonic study, it is significant for clinical therapy to master the normal anatomy, blood parameters value and flow of arteriae surales.
Objective To discuss the relationship between the changes of hepatic blood flow detected by usingspectral Doppler ultrasound and serum TNF- α and IL-1 β levels after liver ischemia/reperfusion (I/R) of rat. Methods The hepatic ischemia 15 min and reperfusion models were established by using pringle method. The hepatic blood flow of hepatic artery and portal vein at 1, 6, and 24 hours after liver I/R were detected by using spectral Doppler ultrasound, the total blood flow volume (FV) was calculated, and the serum TNF- α and IL-1 β levels at each time point were detected. The correlation between the TNF-α, IL-1 β, and FV were analyzed. Results The FV at 1 hour and 6 hours after reperfusion in I/R group were less than those in sham operation (SO) group 〔(52.08±11.88) mL/min vs. (85.32±29.85) mL/min and (44.69±8.75)mL/min vs. (81.41±28.67) mL/min, P<0.05〕. The FV at 24 hours after operation or reperfusion of 2 groups was no significant differences (P>0.05). The serum content of TNF-α at 1 hour after reperfusion in I/R group was higher than that in SO group 〔(310.52±39.83)pg/mL vs. (240.74±31.65)pg/mL, P<0.05〕. The serum contents of TNF-α at 6 and 24 hours after operation or reperfusion of 2 groups were no significant differences (P>0.05). The serum contents of IL-1β at 1 hour and 6 hours in I/R group were higher than those in SO group 〔(38.08±3.73) pg/mLvs. (22.03±0.79) pg/mL and (27.44±6.11) pg/mL vs. (21.78±0.71) pg/mL, P<0.05〕. The serum content of IL-1β at 24 hours after operation or reperfusion of 2 groups was no significant differences (P>0.05). There was a negative correlation between the FV and TNF-α or IL-1β (r=-0.43, P<0.05;r=-0.46, P<0.05). Conclusions Spectral Doppler ultrasound can observe the changes of hepatic blood flow and evaluate the hepatic microcirculation indirectly. The hepatic blood flow after liver I/R decreases and it may be related to over expression of TNF-α and IL-1β.
ObjectiveTo investigate the application of high frequency color Doppler ultrasound (HFCDU) combined with wide-field imaging in the preoperative navigation of anterolateral thigh perforator flap graft.MethodsBetween January 2017 and March 2018, 28 patients with skin and soft tissue defects were treated, including 22 males and 6 females, with an average age of 33.5 years (range, 17-66 years). The causes of injury included 2 cases of scald scar, 7 cases of heavy object crushing injury, 12 cases of traffic accident injury, 4 cases of fall injury, 2 cases of machine injury, and 1 case of infection ulcer. Injury sites included 6 cases of hand and wrist, 12 cases of lower leg, 10 cases of foot. After debridement, the wound area ranged from 6.0 cm×3.5 cm to 24.0 cm×9.0 cm, and all patients were treated with free circumflex femoral artery perforator flap graft. Combo of HFCDU and wide-field imaging navigation were done preoperatively to detect the origin, quantity, course, surface location, hemodynamic characteristics, and the relationship with body area of perforator branch of lateral circumflex femoral artery. According to the perforator information displayed by wide-field imaging of source artery, the dominant perforator was determined to be a pedicle for designed flap. The flap size ranged from 7.0 cm×4.5 cm to 26.0 cm×7.0 cm. The flap donor area was sutured directly.ResultsThe dominant perforator was successfully detected by HFCDU combined with wide-field imaging in 28 patients before operation. The existence of the perforator was confirmed during operation, and the location was accurate. The course characteristics of the perforate were consistent with the results of wide-field imaging. The grafted flaps survived completely among 27 patients after operation. Necrosis at the edge of the flap was observed in 1 patient, which healed after dressing change. All patients were followed up 3-12 months, with an average of 9 months. All the flaps have good blood supply, good elasticity and shape. The donor areas healed perfectly.ConclusionUsing HFCDU and wide-field imaging navigation for designing of anterolateral thigh perforator flaps can clearly show the characteristics of perforators, hemodynamic information, and the relationship with body area, so that the surgeons can understand the perforators more accurately and intuitively, and improve the success and efficiency of flap graft surgery.
The ultrasound Doppler fetal heart rate measurement is the gold standard of fetal heart rate counting. However, the existing fetal heart rate extraction algorithms are not designed specifically to suppress the high maternal interference during the second stage of labor, and false detection occurrences are common during labor. With this background, a method combining time-frequency frame template library optimal selecting and non-linear template matching is proposed. The method contributes a template library, and the optimal template can be selected to match the signal frame. After the short-time Fourier transform of the signal, the difference between the signal and the template is optimized by leaky rectified linear unit (LReLU) function frame by frame. The heart rate was calculated from the peak of the matching curve and the heart rate was calculated. By comparing the proposed method with the autocorrelation method, the results show that the detection accuracy of the proposed method is improved by 20% on average, and the non-linear template matching of 23% samples is at least 50% higher than the autocorrelation method. This paper designs the algorithm by analyzing the characteristics of the interference and signal mixing. We hope that this paper will provide a new idea for fetal heart rate extraction which not only focuses on the original signal.
Objective To investigate the accuracy of color Doppler ultrasound (CDU) and CT angiography (CTA) in the preoperative evaluation of perforator vessels in free posterior interosseous artery perforator (PIAP) flaps. Methods Between January 2020 and December 2023, 19 patients with hand skin and soft tissue defects caused by trauma were admitted. There were 11 males and 8 females, with a median age of 45 years (range, 26-54 years). The interval between injury and admission was 5-11 days (mean, 7.2 days). The skin and soft tissue defects were located on the dorsum of the hand in 8 cases and on the fingers in 11 cases. The size of defect ranged from 4.0 cm×2.5 cm to 7.5 cm×3.5 cm. After locating the perforator vessels through CDU and CTA before operation, the free PIAP flaps were designed to repair hand defects, with the size of 4.5 cm×3.0 cm-7.5 cm×4.0 cm. The defects of donor sites were directly sutured. The number and diameter of perforator vessels in the posterior interosseous artery detected by CDU and CTA were compared. The differences in localization of perforator vessels using CDU and CTA and their clinical effects were also compared to calculate the accuracy and recognition rate. During follow-up, the survival of the skin flap was observed, and the Vancouver scar scale (VSS) score was used to evaluate the healing of the donor site, while the visual analogue scale (VAS) score was used to evaluate the patient’s satisfaction with the appearance of the skin flap. Results The number and the diameter of PIAP vessels was 5.8±1.2 and (0.62±0.08) mm assessed by CDU and 5.2±1.0 and (0.60±0.07) mm by CTA, showing no significant difference between the two methods (P>0.05). The number, course, and distribution of perforator vessels of the PIAP vessels observed during operation were basically consistent with those detected by preoperative CDU and CTA. Compared with intraoperative observation results, the recognition rates of dominant perforating vessels by CDU and CTA were 95.0% (18/19) and 89.5% (17/19), respectively, and the accuracy rates were 100% (19/19) and 84.2% (16/19), with no significant difference between the two methods (P>0.05). All flaps survived after operation, and all wounds and incisions at donor sites healed by first intention. All patients were followed up 6-13 months (mean, 8.2 months). At last follow-up, the skin flaps had elasticity and soft texture, with the patient satisfaction VAS score of 9.2±0.8. The donor sites had no obvious scar hyperplasia with the VSS score of 11.7±0.9. Conclusion CDU and CTA accurately identify the dominant perforator vessels and provide reliable information for vessel localization, facilitating precise flap harvesting and minimizing donor site injury. However, CDU offers superior visualization of distal end of perforator vessels in the forearm compared to CTA.
ObjectiveTo observe the color Doppler flow imaging (CDFI) features of vitreoretinal lymphoma (VRL). MethodsRetrospective case series. From January 2022 to December 2024, 71 eyes of 42 patients diagnosed with VRL at the Eye Center of Beijing Tongren Hospital were enrolled. Among them, 17 were male and 25 female; 29 had bilateral and 13 unilateral involvement. Age ranged 17-78 years (median 59 years). Eleven cases had histopathologic confirmation and 31 were clinically diagnosed. All patients underwent CDFI and optical coherence tomography (OCT). CDFI findings were analyzed, noting the presence or absence of vitreous opacities (centrifugal distribution), posterior vitreous detachment (PVD), retinal detachment, and retinal elevated lesions. With Doppler overlay, blood flow within retinal lesions was assessed. The χ2 test was used to compare the detection rates of retinal lesions by CDFI and OCT, while Cohen’s Kappa assessed agreement in identifying the depth of lymphoma cell infiltration. ResultsAmong 71 eyes, vitreous opacity occurred in 66 eyes (93.0%, 66/71), of which 40 eyes (60.6%, 40/66) showed centrifugal opacity. 58 eyes (81.7%, 58/71) had posterior vitreous detachment. Retinal detachment occurred in 7 eyes (9.9%, 7/71). Retinal occupying lesions occurred in 23 eyes (32.4%, 23/61), of which 15 eyes (65.2%, 15/23) showed blood flow signals on the surface of the lesions but no blood flow signals inside the lesions by CDFI, and OCT showed that tumor cells gathered under the retinal pigment epithelium. CDFI showed blood flow signals inside the lesions in 8 eyes (34.8%, 8/23), and OCT showed that tumor cells gathered between retinal neuroepithelial layers. The lesion detection rate of OCT (69.6%, 16/23) was significantly lower than that of CDFI (100.0%, 23/23) (χ2= 6.066, P=0.014). OCT and CDFI showed perfect agreement in determining the depth of tumor cell infiltration (Kappa=1.0).ConclusionsThe ultrasonographic manifestations of VRL include vitreous opacity, PVD, and some retinal occupying lesions. Vitreous opacity often presents a characteristic centrifugal distribution. By observing whether there is blood flow signal in retinopathy using Doppler, the level of lymphoma cell infiltration can be suggested.
ObjectiveTo evaluate the clinical value of color Doppler ultrasound in diagnosing prehepatic portal hypertension. MethodsA retrospective analysis was performed to analyze the results of color Doppler ultrasonography in 9 patients with prehepatic portal hypertension diagnosed between June 2012 and January 2015, including vessel diameter, shape, nature and direction of blood flow, and fistula blood flow spectrum. ResultsAmong the 9 patients, the color Doppler ultrasound found 3 patients with regional portal widened, increased and faster blood flow with the emergence of low-impedance spectrum artery, splenic vein widened with returning blocked and flocculent substance within the splenic vein lumen, irregular or streak-shaped low weak echo during splenic vein reduction, and unstable or weakened blood flow velocity. Two patients were confirmed with splenic vein thrombosis by ultrasound and other imaging methods with significantly reduced blood in splenic vein. For the other four patients with regional portal hypertension, obvious abnormalities in portal system were not detected by color Doppler ultrasound, but they were checked with other methods. The ultrasound positive diagnosis of the 9 patients was 5, with 4 missed. ConclusionThe color Doppler ultrasound has some values in screening, diagnosis and follow-up of prehepatic portal hypertension, but it can also be influenced by many factors with a high missed diagnosis rate. Carefully observing the portal system lumen structure, internal echo and blood flow combined with other imaging studies, and emphasizing clinical history of the patients can further improve diagnostic accuracy.
ObjectiveTo investigate the application value of contrast-enhanced ultrasound (CEUS) technique to assist the repair of oral and maxillofacial defects by superficial inferior epigastric artery perforator flap.MethodsSixteen oral cancer patients, 10 males and 6 females, who were to undergo superficial inferior epigastric artery perforator flap repair between June 2018 and February 2020, were selected, with an average age of 55.8 years (range, 24-77 years). There were 13 cases of squamous cell carcinoma, 2 cases of adenoid cystic carcinoma, and 1 case of mucinous epidermis-like carcinoma. The color Doppler ultrasound (CDUS) and CEUS were used to screen the superficial inferior epigastric artery, assisted in the design of the flap, and compared it with the actual intraoperative exploration. The sensitivity, specificity, positive predictive value, and negative predictive value of CEUS and CDUS examinations were analyzed. Fourteen of 16 patients were repaired with superficial inferior epigastric artery perforator flap, and 2 patients were repaired with superficial iliac artery flap because the source artery was not found. After surgery, regular follow-up was performed to check for disease recurrence and metastasis and to evaluate the appearance of the patien’s donor area, the recovery of transoral feeding function, and the presence of complications.ResultsComparison of preoperative CDUS and CEUS findings and intraoperative exploration showed that CEUS had 100% sensitivity, specificity, positive predictive value, and negative predictive value for vascular exploration of the superficial inferior epigastric artery perforator flap, compared with 57%, 100%, 100%, and 25% for CDUS. The preoperative CDUS identified 25 penetrating vessels in 14 cases repaired with superficial inferior epigastric artery flaps. All vessel signals were enhanced by CEUS enhancement, and an additional 11 penetrating vessels were identified confirmed intraoperatively. The preoperative CEUS measurements of the initial diameter of superficial arteries in the abdominal wall were significantly higher than both CDUS and intraoperative measurements (P<0.05); the difference in peak systolic velocity between CEUS and CDUS measurements was significant (t=3.708, P=0.003). One case of superficial epigastric artery perforator flap developed venous embolism crisis at 48 hours after operation, the wound healing delayed. The other incisions in donor sites healed by first intention. All the patients were followed up 3-12 months, with an average of 8 months. No recurrence or metastasis appeared during the follow-up. There was no serious complications such as abdominal wall hernia, the location of abdominal scarring was hidden, and transoral feeding was resumed.ConclusionThe superficial inferior epigastric artery perforator flap with small injury in supply area and hidden scar location is a better choice for repairing oral and maxillofacial defects. The use of CEUS technique to assist the preoperative design of the superficial inferior epigastric artery perforator flap has good feasibility and high accuracy.
With introduction of current main methods for heart fluid mechanics researches, we studied the characteristics and weakness for three primary analysis methods based on magnetic resonance imaging, color Doppler ultrasound and grayscale ultrasound image, respectively. It is pointed out that particle image velocity (PIV),speckle tracking and block match have the same nature, and three algorithms all adopt block correlation. The further analysis shows that, with the development of information technology and sensor, the research for cardiac function and fluid mechanics will focus on energy transfer process of heart fluid, characteristics of Chamber wall related to blood fluid and Fluid-structure interaction in the future heart fluid mechanics fields.