With the increasing popularity of smart phones, the electronic test of clinical trials has become a common means of investigation research. The APP of REDCap system can quickly construct a multi-center questionnaire system and obtain a large quantity of reliable and complete questionnaire data, shortening the cost and cycle of research. This paper primarily introduces how to conduct research on electronic questionnaire based on mobile APPs of REDCap system.
As a tool for building consensus among groups, Delphi technique has been widely used in healthcare research which is appropriate for clinical questions where quantitative methods are unlikely to yield results that can be successfully implemented in practice. Researchers in palliative care developed standards for conducting and reporting Delphi studies (CREDES). This paper introduces and interprets the specific content of CREDES standards, with a view to providing reference for the evaluation of Delphi research design quality and report transparency.
Objective To compare the screening ability of modified Hodge test (MHT), modified carbapenem inactivation method (mCIM) and EDTA-carbapenem inactivation method (eCIM) for drug resistance phenotype of carbapenemase-producing Klebsiella pneumoniae. MethodsCarbapenem resistant Klebsiella pneumoniae (CRKP) strains clinically isolated from 5 hospitals in Chengdu between January 2019 and December 2021 were collected, and the carbapenem sensitive Klebsiella pneumoniae (CSKP) strains isolated in the same period were randomly collected. Polymerase chain reaction (PCR) -amplified carbapenem resistance gene as the gold standard, the consistencies between the results of the three phenotypic tests and the results of genetic testing were compared. Results A total of 160 CRKP strains and 120 CSKP strains were isolated. Among the 160 CRKP strains, carbapenem resistance genes were detected in 156 strains, including 105 strains of blaKPC-2, 41 strains of blaNDM-1, 8 strains of blaKPC-19, 1 strain of blaIMP-1, and 1 strain carrying both blaKPC-2 and blaNDM-1. None of the 120 CSKP drug resistance genes were detected. The sensitivity and specificity of carbapenem screening for MHT and mCIM were 73.08% (114/156), 96.67% (116/120), 97.44% (152/156) and 98.33% (118/120), respectively. The sensitivity and specificity of eCIM for screening metalloenzymes were 95.35% (41/43) and 100% (120/120), respectively. Conclusions The sensitivity of MHT to detect carbapenemase is lower than that of the other two methods, and it is easy to produce false negatives when it is used to detect metalloenzymes. The mCIM has high sensitivity and is consistent with the PCR genetic test results. The combined detection of mCIM and eCIM can screen carbapenemases more effectively and distinguish the types of carbapenemases.
Objective To investigate the expression of ectodysplasin (EDA) genesignaling and its relationship with the development and regeneration of sweat glands. Methods The articles concerned in the latest years wereextensively reviewed. Results EDA gene is an important signaling pathway associated with the developmental procedure of sweat glands in early fetal stage. Abnormality or depletion of function in sweat glands partially owed to the defect of EDA gene. Conclusion EDA signaling has its biological significance in inducing development and morphogenesis of sweat glands and in maintaining physiological function of skin. It could be a new approach to repair or regenerate the sweat glands for clinical therapy by regulating the expression of EDA gene.
Abstract: Objective To study the impact of different kinds of mechanical circulation support devices on plasma free hemoglobin(FHb). Methods From Mar. 2004 to Dec. 2005, 20 patients received mechanical circulation support in Fu Wai Hospital, who were divided into 4 groups according to the different type of supporting devices. 9 got extracorporeal membrane oxygenation (ECMO) treatment, 8 received BVS5000 left ventricular support, 2 got MEDOS left ventricular support and 1 received AB5000 left ventricular support. Random control group included 9 cardiotomy patients after CPB supporting and 9 patients with offpump coronary artery bypass grafting during the same period. Parameters such as FHb, Tbil, Dbil, Cr and BUN were monitored throughout the supporting term. The results were compared according to the different types of mechanical circulation support devices. Results The elevation of FHb caused by CPB could be decreased to normal within 1d. However, in BVS5000 group, the elevated FHb level decreased to normal till 2 days later. The others mechanical circulation support devices such as ECMO, MEDOS, AB5000 elevated the FHb throughout the whole supporting period. Compared with those in ECMO group, the patients in BVS5000 group had obviously lower level of FHb since the third day after the beginning of supporting. In patients who got ECMO treatment, there was a trend that the elevation degree of FHb was lower in those with support flow rate less than 2.5 L/min. For most patients got devices support, there was also an elevation of Tbil and BUN level during the supporting period. Conclusion Mechanical circulation support devices, such as ECMO, BVS5000, MEDOS and AB5000, can cause red cell destruction in acceptable level. BVS5000 has much smaller impact on cell destruction than others do in postoperative patients.
Objective To establish a rapid, simple, and economic method to prepare osteoporosis (OP) in vitro model. Methods Eighty pairs of fresh goat femur were collected from 18-month-old female goats and were randomly divided into 4 groups (20 pairs in each group). The femur was immersed decalcifying solution (18% EDTA) for 1-5 days (group B), 6-10 days (group C), and 11-15 days (group D), while group A had no treatment as control. Four pairs of femur were taken out every day. Quantitative computed tomography was used to scan the medial and lateral femoral condyles, and the bone mineral density (BMD) was calculated. Electronic universal testing machine was used to do three-point bending test and compress and tensile ultimate strenght test, and the mechanical parameters for femur were calculated. Results With demineralized time passing, BMD of the medial and lateral femoral condyles were downtrend in groups A, B, C, and D, showing significant differences among 4 groups (P lt; 0.05); BMD of the lateral femoral condyle was significantly higher than that of the medial femoral condyle in each group (P lt; 0.05). The three-point bending test showed that broken load, ultimate strength, and elastic modulus of groups A and B were significantly higher than those of groups C and D (P lt; 0.05); but no significant difference was found between groups A and B, and between groups C and D (P gt; 0.05). Compress and tensile ultimate strength test showed that the compress and tensile ultimate strengths were significantly higher in group A than in groups C and D (P lt; 0.05), and in group B than in group D (P lt; 0.05), but no significant difference was found between groups A and B, between groups B and C, and between groups C and D (P gt; 0.05). Conclusion The 18% EDTA immersing for 6-15 days is a fast, simple, economical method to prepare an OP in vitro model of goat femur.
Objective To analyze the effectiveness of combined treatment of lumbar spondylolisthesis with MED, Quadrant, and Sextant-R systems. Methods Between August 2006 and June 2011, 35 patients with lumbar spondylolisthesis were treated, including 11 cases of isthmic spondylolisthesis and 24 cases of degenerative spondylolisthesis. There were 25 males and 10 females, with a mean age of 55 years (range, 33-71 years). The mean disease duration was 37 months (range, 8-75 months). Spondylolisthesis occurred at L4, 5 level in 21 patients and at L5, S1 level in 14 patients. According to Meyerding classification, 35 cases were rated as dergee I. The minimally invasive surgeries were performed by paraspinal muscle approach; Quadrant system was used for decompression and fusion at severe side, MED system for windowing of lamina at mild side, and Sextant-R system for fixation and reduction. Visual analogue scale (VAS) score was used to evaluate pain, Oswestry disability index (ODI) to evaluate clinical outcomes, spondylolishesis ratio and intervertebral height to evaluate spondylolisthesis reduction. Results Lumbar continuous thin layer CT at postoperation showed that no pedicle screw invaded spinal canal and intervertebral fusion device was at good position. Incisions healed by first intention. All patients were followed up 18-38 months (mean, 26 months). All patients got bone fusion and had no internal fixation failure by radiologic examination at 1 year after operation. Low back pain was relieved, lumbar function improved obviously, and satisfactory reduction of spondylolisthesis was obtained. At 2 weeks and 1 year after operation, the VAS score, ODI score, spondylolisthesis ratio, and intervertebral height were significantly improved when compared with preoperative ones (P lt; 0.05). VAS score and ODI score showed significant differences (P lt; 0.05) between at 2 weeks and 1 year after operation. Spondylolisthesis ratio and intervertebral height showed no significant difference (P gt; 0.05) between at 2 weeks and at 1 year after operation. Conclusion Minimally invasive surgical management for lumbar spondylolisthesis via MED, Quadrant, and Sextant-R systems is a safe and effective surgical technique. However, its indications should be well considered.
Since November 1996, 20 cases of craniofacial deformities, either from congenital or traumatic, were treated with MEDPOR surgical implant made from a linear high density polythylene. The animal experiment had shown that the MEDPOR had good organotrophic characteristics allowing tissue ingrowth. The biocompatibility studies in vitro and in vivo had shown that the MEDPOR biomaterial was free from any observable systemic or cytotoxic effect. In the clinical application, it was found that the MEDPOR could be easily modeled and maintained. Because of the ability to induce tissuee ingrowth, the tenacity and stability of the material were enhanced. A total of seven cases of cranial defects, 8 cases of periobital defects or depressed periobital regions, 2 cases of traumatic auricular defects, 2 cases of traumatic saddle nose and 1 case of maldevelopment of mandible angle were treated. All of the cases were followed up for 6 months, the results were satisfactory.
Based on both functional and structural studies of excessive activity, fronto-striatal-thalamic-cortical and cortico-striatal circuits have been hypothesized to underlie the pathophysiology of obsessive-compulsive disorder (OCD). However, the neurobiological underpinnings of OCD refractory to medication and therapy remain controversial. This study aimed to evaluate neuroanatomical abnormalities of the whole brain and to evaluate visual processing in patients with refractory OCD. This study was comprised of 2 experiments. The neuroanatomical abnormalities of the whole brain were evaluated using a visual search in combination with overactive performance monitoring (Experiment I), and visual processing was evaluated using event-related potentials recorded from subjects during performance of a visual search task. We also examined the amplitudes and latency of the error-related negativity (ERN) using a modified flanker task (Experiment II). Standard low-resolution electromagnetic tomography analysis was applied to determine the special areas. Patients with refractory OCD had a significantly greater number of saccades and prolonged latencies relative to the healthy controls. Scalp map topography confirmed that visual cognitive and executive dysfunction was localized to the fusiform gyrus. Furthermore, we found that during a modified flanker task, ERNs had a greater amplitude and a prolonged latency relative to those of the healthy controls. Further data analysis suggested that cognitive dysfunction and compulsive behavior in OCD patients were linked to abnormalities within the dorsolateral prefrontal cortex (DLPFC). We identified abnormal activities within the fusiform gyrus and DLPFC that likely play important roles in the pathophysiology of OCD.
Recent research has demonstrated that static magnetic fields (SMF) can generate an analgesic effect in different conditions. The present study explored effects of SMF on pain levels and expressions of P2X3 receptors in trigeminal ganglion (TG) in mice after experimental tooth movement (tooth movement induced by springs between teeth). Experiments were performed in male mice (body mass: 25-30g) and divided into SMF+force group, force group, and no force group. Exposure time was over 22h per day. Mouse Grimace Scale was used for evaluating orofacial pain levels during experimental tooth movement at 4h and 1, 3, 7, and 14 days. Meanwhile, expression levels of P2X3 receptors in the TG were evaluated by immunohistochemistry and western blotting at same time points. We finally found that during experimental tooth movement, pain levels of mice peaked at 3 days, and then decreased. While pain levels of mice were reduced in the SMF environment at 4h, 1 and 3 days, there was a significant difference at 1 and 3 days. Meanwhile, under the action of SMF, expression levels of P2X3 receptors in TG were significantly lower at 4h, 3 and 7 days. These results suggest that SMF can reduce pain levels in mice, and down-regulate P2X3 receptors in TG. Bioelectromagnetics. 38:22-30, 2017. (c) 2016 Wiley Periodicals, Inc.