west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Kirschner wire" 27 results
  • SPRING KIRSCHNER WIRE IN THE TREATMENT OF FRACTURE OF PATELLA

    From August 1986 to October 1990, 34 cases of fractures of patella were treated by the self-designed spring Kirschner wire, in which, 25 cases were followed up for an average of 1.5 years. The excellentgood rate reached 88%. In comparing with the traditional method of treatment, it gave more secure fixation for fracture, without the need or only a short time of immobilization needed, short treatment course and satisfactory return of function.

    Release date:2016-09-01 11:34 Export PDF Favorites Scan
  • TREATMENT OF ULNAR COLLATERAL LIGAMENT AVULSION FRACTURE OF THUMB METACARP-OPHALANGEAL JOINT USING A COMBINATION OF Kirschner WIRE AND SILK TENSION BAND

    Objective To investigate the effectiveness of Kirschner wire combined with silk tension band in the treatment of ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint. Methods Between September 2008 and October 2011, 14 patients with ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint were treated using a combination of Kirschner wire and silk tension band. There were 8 males and 6 females, aged 23-55 years (mean, 40.8 years). The causes of injury were machinery twist injury in 5 cases, manual twist injury in 4 cases, falling in 4 cases, sports injury in 1 case. The time from injury to operation was 2 hours-14 days. All the patients presented pain over the ulnar aspect of the metacarpophalangeal joint of the thumb, limitation of motion, and joint instability with pinch and grip. The lateral stress testing of the metacarpophalangeal joint was positive. Function training was given at 2 weeks after operation. Results All incisions healed by first intention. The lateral stress testing of the metacarpophalangeal joint was negative. All the patients were followed up 6-18 months (mean, 13.1 months). The X-ray films showed good fracture reduction and healing with an average time of 7 weeks (range, 4-10 weeks). At last follow-up, the thumbs had stable flexion and extension of the metacarpophalangeal joint, normal opposition function and grip and pinch strengths. According to Saetta et al. criteria for functional assessment, the results were excellent in 11 cases and good in 3 cases; the excellent and good rate was 100%. Conclusion It is an easy and simple method to treat ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint using Kirschner wire combined with silk tension band, which can meet the good finger function.

    Release date:2016-08-31 04:22 Export PDF Favorites Scan
  • Effectiveness on treatment of metacarpal avulsion fracture with Kirschner wire buckling combined with bone fixation

    Objective To summarize the effectiveness of Kirschner wire buckling combined with bone fixation in the treatment of metacarpal avulsion fracture. Methods The clinical data of 35 patients of metacarpal avulsion fracture admitted between March 2017 and June 2022 were retrospectively analyzed. There were 22 males and 13 females; the age ranged from 20 to 55 years, with an average of 31.6 years. There were 17 cases of the second metacarpal avulsion fracture, 6 cases of the fourth metacarpal avulsion fracture, and 12 cases of the fifth metacarpal avulsion fracture. The causes of injury included 21 cases of strangulation, 8 cases of sprain, and 6 cases of sports injury. X-ray film examination showed that the size of the avulsion fracture of metacarpal bone ranged from 0.30 cm×0.20 cm to 0.55 cm×0.45 cm. The total active motion (TAM) of the injured finger before operation was (154.00±17.38)°. The time from injury to operation was 3-10 days, with an average of 5.8 days. Follow-up regularly after operation, X-ray film and CT examination were performed to evaluate fracture healing and TAM of injured finger was measured. The finger function was evaluated by the trial standard of upper limb function evaluation of Hand Surgery Society of Chinese Medical Association. Results All the incisions healed by first intention. All 35 patients were followed up 9-36 months, with an average of 28 months. All metacarpal avulsion fractures achieved bony healing, and the healing time was 4-6 weeks, with an average of 4.8 weeks. The metacarpophalangeal joint of the patient was stable, without stiffness, and the flexion and extension activities were good. At last follow-up, the TAM of the injured finger reached (261.88±6.23)°, which was significantly different from that before operation (t=−35.351, P<0.001). The finger function was evaluated according to the trial standard of upper limb function evaluation of the Society of Hand Surgery of Chinese Medical Association, and 33 cases were excellent and 2 cases were good, with an excellent and good rate of 100%. Conclusion The treatment of metacarpal avulsion fracture with Kirschner wire buckling combined with bone fixation has the advantages of less trauma, firm fixation, and less interference to the soft tissue around metacarpophalangeal joints, which is a good alternative method for the metacarpal avulsion fracture.

    Release date:2023-12-12 05:05 Export PDF Favorites Scan
  • A BIOMECHANICAL STUDY ON INTERNAL FIXATION OF PROXIMAL ULNA COMBINED WITH OLECRANON FRACTURE

    Objective To compare the biomechanical stability of Kirschner wire and tension band wiring, reconstruction plate combined with tension band wiring, and olecranon anatomical plate in fixing proximal ulna combined with olecranon fracture, so as to provide the theoretical evidence for clinical selection of internal fixation. Methods Eight specimens of elbow joints and ligaments were taken from eight fresh male adult cadaveric elbows (aged 26-43 years, mean 34.8 years) donated voluntarily. The model of proximal ulna combined with olecranon fracture was made by an osteotomy in each specimen. Fracture end was fixed successively by Kirschner wire and tension band wiring (group A), reconstruction plate combined with tension band wiring (group B), and olecranon anatomical plate (group C), respectively. The biomechanical test was performed for monopodium compression experiments, and load-displacement curves were obtained. The stability of the fixation was evaluated according to the load value when the compression displacement of fracture segment was 2 mm. Results No Kirschner wire withdrawal, broken plate and screw, loosening and specimens destruction were observed. The load-displacement curves of 3 groups showed that the displacement increased gradually with increasing load, while the curve slope of groups B and C was significantly higher than that of group A. When the compression displacement was 2 mm, the load values of groups A, B, and C were (218.6 ± 66.9), (560.3 ± 116.1), and (577.2 ± 137.6) N, respectively; the load values of groups B and C were significantly higher than that of group A (P lt; 0.05), but no significant difference was observed between groups B and C (t=0.305, P=0.763). Conclusion The proximal ulna combined with olecranon fracture is unstable. Reconstruction plate combined with tension band wiring and olecranon anatomical plate can meet the requirement of fracture fixation, so they are favorable options for proximal ulna combined with olecranon fracture. Kirschner wire and tension band wiring is not a stable fixation, therefore, it should not be only used for proximal ulna combined with olecranon fracture.

    Release date:2016-08-31 04:21 Export PDF Favorites Scan
  • Effectiveness of arthroscopy-assisted combined fixation of Kirschner wire and external fixator for treating extreme distal radial fractures

    Objective To investigate the effectiveness of arthroscopy-assisted combined fixation of Kirschner wire and external fixator for treating extreme distal radial fractures. Methods Between January 2014 and May 2016, 21 patients who suffered from extreme distal radial fractures were treated by arthroscopy-assisted combined fixation of Kirschner wire and external fixator. There were 14 males and 7 females with an age of 32-57 years (mean, 42.3 years). The causes of injury included falling in 13 cases and traffic accident in 8 cases. The fracture type included 8 cases of type 23C1, 9 cases of type 23C2, and 4 cases of type 23C3 according to AO/OTA classification. The time from injury to operation was 3-7 days (mean, 4.4 days). The Mayo score and disability of arm, shoulder, and hand (DASH) score were used to assess the pain and function of the wrist joint. Results There was no needle red swelling, tendon irritation, or orther early complications. All the patients were followed up 10-35 months (mean, 18.3 months). The fracture healing time was 9-13 weeks (mean, 10.6 weeks). At last follow-up, the Mayo score was 87-94 (mean, 90.9); and 17 cases were excellent and 4 were good. The DASH score was 7-13 (mean, 10.6). Conclusion Arthroscopy-assisted combined fixation of Kirschner wire and external fixator for treating extreme distal radial fractures has the advantages of firm fixation, early functional exercise, less postoperative complications, and good functional recovery of wrist joint.

    Release date:2017-12-11 12:15 Export PDF Favorites Scan
  • Short-term effectiveness of Kirschner wire elastic fixation in treatment of Doyle type Ⅰ and Ⅱ mallet finger

    Objective To evaluate the short-term effectiveness of Kirschner wire (K-wire) elastic fixation in the treatment of Doyle type Ⅰ and Ⅱ mallet finger. Methods Between July 2016 and March 2017, 18 patients with Doyle type Ⅰ and Ⅱ mallet finger were treated. There were 12 males and 6 males, with an average age of 45 years (range, 16-61 years). The index finger was involved in 2 cases, the middle finger in 3 cases, the ring finger in 10 cases, and the little finger in 3 cases. The interval from injury to operation ranged from 2 hours to 45 days (median, 5.5 hours). There were 8 patients of closed wound and 10 patients of open wound. Fourteen patients were simply extensor tendon rupture and 4 were extensor tendon rupture complicated with avulsion fracture. The distal interphalangeal joints (DIPJ) of injured fingers were elastically fixed with the K-wire at mild dorsal extend position. The K-wire was removed after 6 weeks, and the functional training started. Results The operation time was 34-53 minutes (mean, 38.9 minutes). Patients were followed up 3-8 months (mean, 5 months). All incisions healed primarily and no K-wire loosening or infection happened during the period of fixation. All mallet fingers were corrected. The range of motion (ROM) in terms of active flexion of injured DIPJ was (75.83±11.15)° at 6 weeks after operation, showing significant difference when compared with the normal DIPJ of contralateral finger [(85.28±6.06)°] (t=3.158, P=0.003). The ROM in terms of active flexion was (82.67±6.78)° in 15 patients who were followed up at 8 months after operation, showing no significant difference when compared with the normal DIPJ of contralateral finger [(86.00±5.73)°] (t=1.454, P=0.157). After the removal of K-wire at 6 weeks, visual analogue scale (VAS) score of active flexion and of passive flexion to maximum angle were 1.78±0.88 and 3.06±1.06, respectively. According to the total active motion criteria, the effectiveness was rated as excellent in 10 cases, good in 5 cases, moderate in 2 cases, and poor in 1 case, and the excellent and good rate was 83.33%. The patients’ satisfaction were accessed by Likert scale, which were 3-5 (mean, 4.2). Conclusion K-wire elastic fixation in the treatment of Doyle typeⅠand Ⅱ mallet finger can repair the extensor effectively, correct the mallet finger deformity, and also be benefit for the flexion-extension function restoration of DIPJ.

    Release date:2017-11-09 10:16 Export PDF Favorites Scan
  • Effectiveness analysis of three internal fixation methods in treatment of avulsion fracture of tibial tubercle in adolescents

    Objective To analyze the effectiveness of three internal fixation methods, namely hollow screw combined with Kirschner wire tension band, hollow screw combined with anchor nail, and modified 1/3 tubular steel plate, in the treatment of avulsion fracture of tibial tubercle (AFTT) in adolescents. Methods Between January 2018 and September 2023, 19 adolescent AFTT patients who met the selection criteria were admitted. According to different internal fixation methods, patients were divided into group A (8 cases, hollow screw combined with Kirschner wire tension band), group B (6 cases, hollow screw combined with anchor nail), and group C (5 cases, modified 1/3 tubular steel plate). There was no significant difference in the baseline data of age, gender, side, cause of injury, Ogden classification, and time from injury to operation among the three groups (P>0.05). The range of motion (ROM), weight-bearing time, normal activity time of knee joint, and the hospital for special surgery (HSS) score at last follow-up were recorded and compared among the three groups. Recorded whether the fracture was displaced, whether the fracture line was blurred at 1 month after operation, whether there was epiphyseal dysplasia, and whether there was incision infection and other complications. Results There was no significant difference in hospital stay between the groups (P>0.05). All patients were followed up 10-24 months, with an average of 14.3 months; there was no significant difference between the groups (P>0.05). All the incisions healed well without soft tissue irritation or fracture nonunion, and no limb shortening deformity or epiphyseal dysplasia was found during follow-up. At 1 month after operation, the knee joint ROM and hospitalization expenses in group A were better than those in groups B and C, the fracture healing time, knee joint weight-bearing time, and normal activity time of knee joint were better than those in group C, and the hospitalization expenses in group C were better than those in group B, with significant differences (P<0.05); there was no significant difference in the other indicators between the groups (P>0.05). In group A, the fracture line was blurred 1 month postoperatively, the fracture ends were in close contact, and there was no fracture displacement; in groups B and C, the fracture line was clear in 2 cases, and 1 case in group C had slight fracture displacement; except for 1 case in group B, there was no fracture split in the other two groups. There was no significant difference in the incidences of blur of fracture line, fracture displacement, and intraoperative bone split between the groups at 1 month after operation (P>0.05). At last follow-up, the HSS scores of knee joints in the three groups were excellent and good, and there was no significant difference between the groups (P>0.05).ConclusionHollow screw combined with Kirschner wire tension band technique is effective in treating adolescent AFTT, which has the advantages of stabilizing fracture, accelerating fracture healing and rehabilitation, early feasible knee joint functional exercise, and reducing hospitalization expenses.

    Release date:2025-01-13 03:55 Export PDF Favorites Scan
  • Feasibility study of Kirschner wire-fixation-cortical bone technique in treatment of intertrochanteric fracture

    Objective To explore the feasibility and effectiveness of maintaining the reduction of unstable intertrochanteric fractures by Kirschner wire-fixation-cortical bone technique. Methods Forty patients with intertrochanteric fracture [AO/Orthopaedic Trauma Association (AO/OTA) type 31-A2.2] admitted between May 2015 and January 2017 and requiring closed reduction and proximal femoral nail antirotation (PFNA) were randomly divided into trial group (intraoperative Kirschner wire-fixation-cortical bone technique group, 20 cases) and control group (conventional treatment group, 20 cases). There was no significant difference in general data of gender, age, side, body mass index, cause of injury, time from injury to operation between the two groups (P>0.05). The operation time, intraoperative blood loss, and intraoperative fluoroscopy times of the two groups were recorded; the reduction quality of fracture was observed according to the corresponding relationship between medial and anterior cortex (positive, neutral, and negative support) of intraoperative fluoroscopy proposed by ZHANG Shimin, and the stability of internal fixation and fracture healing were observed; Harris score was used to evaluate the recovery of hip function at 12 months after operation. Results In the trial group, 6 cases (30%) had 2 Kirschner wires implanted less than 4 times, 7 cases (35%) had 5-8 times, and 7 cases (35%) had 9 times or more. There was no significant difference in operation time and intraoperative blood loss between the two groups (P>0.05), but the blood transfusion volume and intraoperative fluoroscopy times in the trial group were significantly less than those in the control group (P<0.05). Both groups were followed up 13-21 months, with an average of 17 months. There was no complications such as wound infection, deep venous thrombosis of lower extremities, refracture, and internal fixation-related complications. The quality of intraoperative reduction in the trial group was significantly better than that in the control group (Z=–2.794, P=0.024). The Harris score of the trial group was significantly better than that of the control group at 12 months after operation (t=2.98, P=0.01). Conclusion The use of Kirschner wire-fixation-cortical bone technique during intertrochanteric fracture closed reduction and PFNA internal fixation surgery can effectively maintain the reduction effect, reduce the number of fluoroscopy, improve the reduction quality, reduce allogeneic blood input, obtain better hip function, and do not increase the operation time and intraoperative blood loss.

    Release date:2019-09-18 09:49 Export PDF Favorites Scan
  • Comparative study of external fixator combined with Kirschner wire fixation and Kirschner wires fixation in treatment of cubitus varus deformity in children

    Objective To analyze the effectiveness comparison of external fixator combined with Kirschner wire fixation and Kirschner wire fixation in the treatment of cubitus varus deformity in children. Methods A retrospective case-control study was conducted to collect 36 children of postoperative supracondylar humerus fracture complicating cubitus varus deformity between January 2018 and July 2022. Among them, 17 cases were treated with distal humeral wedge osteotomy external fixation combined with Kirschner wire fixation (observation group), and 19 cases were treated with distal humeral wedge osteotomy and Kirschner wire fixation (control group). The baseline data including age, gender, deformity side, time from fracture to operation, carrying angle of the healthy side and preoperative carrying angle of the affected side, elbow flexion and extension range of motion, and lateral condylar prominence index (LCPI) showed no significant difference between the two groups (P>0.05). The operation time, hospitalization cost, healing time of osteotomy, postoperative complications, and the carrying angle, LCPI, and elbow flexion and extention range of motion were recorded and compared between the two groups. The elbow function was assessed by Oppenheim score at 3 months after operation and at last follow-up. Results The children in both groups were followed up 13-48 months, with an average of 26.7 months. There was 1 case of needle tract infection in the observation group and 2 cases in the control group, and no nerve injury occurred, the difference in the incidence of complication (5.88% vs 10.53%) between the two groups was not significant (χ2=0.502, P=0.593). There was no significant difference in the operation time and fracture healing time between the two groups (P>0.05); the hospitalization cost of the observation group was significantly higher than that of the control group (P<0.05). The Oppenheim score of the observation group was significantly better than that of the control group at 3 months after operation (P<0.05), but there was no significant difference in the Oppenheim score between the two groups at last follow-up (P>0.05). At last follow-up, the carrying angle of affected side significantly improved in both groups when compared with preoperative ones (P<0.05); the differences of the pre- and post-operative carrying angle of affected side and elbow flexion and extension range of motion showed no significant differences between the two groups (P>0.05), but the difference in pre- and post-operative LCPI of the observation group was significantly better than that of the control group (P<0.05). ConclusionExternal fixator combined with Kirschner wire fixation and Kirschner wire fixation both can achieve satisfactory correction of cubitus varus deformity in children, and the former can achieve better short-term functional recovery of elbow joint and reduce the incidence of humeral lateral condyle protrusion.

    Release date:2024-03-13 08:50 Export PDF Favorites Scan
  • Application of thumb blocking technique with ulnar Kirschner wire threading for Gartland type Ⅲ supracondylar humerus fractures in children

    Objective To explore the effectiveness of thumb blocking technique through closed reduction of ulnar Kirschner wire threading in the treatment of Gartland type Ⅲ supracondylar humerus fractures in children. MethodsThe clinical data of 58 children with Gartland type Ⅲ supracondylar humerus fractures treated with closed reduction of ulnar Kirschner wire threading by thumb blocking technique between January 2020 and May 2021 were retrospectively analyzed. There were 31 males and 27 females with an average age of 6.4 years ranging from 2 to 14 years. The causes of injury were falling in 47 cases and sports injury in 11 cases. The time from injury to operation ranged from 24.4 to 70.6 hours, with an average of 49.6 hours. The twitch of ring and little fingers was observed during operation, the injury of ulnar nerve was observed after operation, and the healing time of fracture was recorded. At last follow-up, the effectiveness was evaluated by Flynn elbow score, and the complications were observed. Results There was no twitch of the ring and little fingers when the Kirschner wire was inserted on the ulnar side during operation, and the ulnar nerve was not injured. All children were followed up 6-24 months, with an average of 12.9 months. One child had postoperative infection in the operation area, local skin redness and swelling, and purulent secretion exudation at the eye of the Kirschner wire, which was improved after intravenous infusion and regular dressing change in the outpatient department, and the Kirschner wire was removed after the initial healing of the fracture; 2 children had irritation at the end of the Kirchner wire, and recovered after oral antibiotics and dressing change in the outpatient department. There was no serious complication such as nonunion and malunion, and the fracture healing time ranged from 4 to 6 weeks, with an average of 4.2 weeks. At last follow-up, the effectiveness was evaluated by Flynn elbow score, which was excellent in 52 cases, good in 4 cases, and fair in 2 cases, and the excellent and good rate was 96.6%. ConclusionThe treatment of Gartland type Ⅲ supracondylar humerus fractures in children by closed reduction and ulnar Kirschner wire fixation assisted with thumb blocking technique is safe and stable, and will not cause iatrogenic ulnar nerve injury.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next