Objective?To approach feasibility, safety, and the application range of pure laparoscopic resection (PLR), hand-assisted laparoscopic resection (HALR), and robotic liver resection (RLR) in the minimally invasive liver resection (MILR). Methods?The clinical data of 128 patients underwent MILR in the Surgical Department of the Shanghai Ruijin Hospital from September 2004 to January 2012 were analyzed retrospectively. According to the different methods, the patients were divided into PLR group, HALR group, and RLR group. The intraoperative findings and postoperative recovery of patients in three groups were compared.?Results?There were 82 cases in PLR group, 3 cases of which were transferred to open surgery;the mean operating time was (145.4±54.4) minutes (range:40-290 minutes);the mean blood loss was (249.3±255.7) ml (range:30-1 500 ml);abdominal infection was found in 3 cases and biliary fistula in 5 cases after operation, but all recovered after conservative treatment;the mean length of hospital stay was (7.1±3.8) days (range:2-34 days). There were 35 cases in HALR group, 3 cases of which were transferred to open surgery;the mean operating time was (182.7±59.2) minutes (range:60-300 minutes);the mean blood loss was (754.3±785.2) ml (range:50-3 000 ml);abdominal infection was found in 1 case, biliary fistula in 2 cases, and operative incision infection in 2 cases after operation, but all recovered after conservative treatment;the mean length of hospital stay was (15.4±3.7) days (range:12-30 days). There were 11 cases in RLR group, 2 cases of which were transferred to open surgery; the mean operating time was (129.5±33.5) minutes (range:120-200 minutes); the mean blood loss was (424.5±657.5) ml (range:50-5 000 ml); abdominal infection was found in 1 case and biliary fistula in 1 case after operation, but all recovered after conservative treatment; the mean length of hospital stay was (6.4±1.6) days (range:5-9 days). The operating time (P=0.001) and length of hospital stay (P=0.000) of the RLR group were shortest and the blood loss (P=0.000) of the PLR group was least among three groups. Conclusions?Minimally invasive resection is a safe and feasible. Different surgical procedures should be chosen according to different cases. The robotic liver resection provides new development for treatment of liver tumor.
ObjectivesTo investigate the safety and efficacy of robot-assisted surgery for mediastinal tumor. MethodsWe respectively analyzed the clinical data of 47 patients with clinical diagnosis of mediastinal tumor undergoing robot-assisted surgery in our hospital from May 2009 to March 2015. There were 29 males and 18 females at age of 48 (20-78) years. Robotic instruments were used through two 8 mm thoracoscopic ports and camera placed through a 12 mm observation port, without any additional utility incision. ResultsAll 47 surgeries were accomplished successfully. The operative time was 73±36 minutes. The blood loss was 48±15 ml. There was only one conversion due to bleeding during the operation. No perioperative mortality or morbidity occurred. There was no perioperative transfusion. Learning curve showed operative time shortened sharply as the procedures increased. After 20 cases of procedure, operative time was stabilized as the learning curve established. The equation is y(min)=-20.41ln(x)+119.43, R2=0.312, P<0.01. ConclusionRobot-assisted surgery for mediastinal tumor are initially proved safe and feasible with great perspective in the new age of minimally invasive thoracic surgery.
ObjectiveTo explore the method of preventing heat steam induced skin damage in robotic nipple-sparing mastectomy and immediate breast reconstruction (R-NSM-IBR) using Da Vinci Robots. Methods A clinical data of 128 female patients with breast cancer, who were treated with R-NSM-IBR between September 2022 and December 2023 and met the selection criteria, was retrospectively analyzed. During robotic nipple-sparing mastectomy, the breasts were covered with gauze cooled by ice water to reduce skin temperature in 99 cases (group A) and were not treated in 29 cases (group B). There was no significant difference in the age, affected side, body mass index, pathological type of breast cancer, and constituent ratios of adjuvant chemotherapy and neoadjuvant chemotherapy between the two groups (P>0.05). Intraoperative breast skin temperature, unilateral robotic nipple-sparing mastectomy time, and the incidence of complications of breast heat steam induced skin damage were recorded. Results The time for unilateral robotic nipple-sparing mastectomy was (77.18±9.23) minutes in group A and (76.38±12.88) minutes in group B, with significant difference between the two groups (P<0.05). The intraoperative breast skin temperature was significantly lower in group A than in group B [(25.61±0.91)℃ vs (33.38±1.14)℃; P<0.05]. Seven cases of heat steam skin damage occurred during operation, including 2 cases (2.0%) in group A and 5 cases (17.2%) in group B, with a significant difference in incidence between the two groups (P<0.05). Among them, 1 patient in group B had a vesication rupture and infection, which eventually led to the removal of the implant; the rest of the patients were treated with postoperative interventions for skin recovery. Conclusion The use of breast covered with gauze cooled by ice water during R-NSM-IBR can effectively reduce the risk of heat steam induced skin damage.
Minimally invasive cardiac surgeries are the trend in the future. Among them, robotic cardiac surgery is the latest iteration with several key-hole incision, 3-dimentional visualization, and articulated instrumentation of 7 degree of ergonomic freedom for those complex procedures in the heart. In particular, robotic mitral valve surgery, as well as coronary artery bypass grafting, has evolved over the last decade and become the preferred method at certain specialized centers worldwide because of excellent results. Other cardiac procedures are in various stages of evolution. Stepwise innovation of robotic technology will continue to make robotic operations simpler, more efficient, and less invasive, which will encourage more surgeons to take up this technology and extend the benefits of robotic surgery to a larger patient population.
Objective To evaluate the effects of robot-assisted Ivor Lewis esophagectomy (RAILE) in surgical treatment of esophageal cancer. Methods We retrospectively analyzed the clinical data of 70 patients diagnosed with mid-lower esophageal cancer undergoing RAILE in the Department of Thoracic Surgery in Ruijin Hospital Affiliated to Shanghai Jiaotong University between May 2015 and April 2018. There were 54 males and 16 females at average age of 62.0±7.6 years. Forty patients underwent circular end-to-end stapled intrathoracic anastomosis and 30 had a double-layered, completely hand-sewn intrathoracic anastomosis. Results The mean operating time was 308.7±60.6 minutes. And blood loss was 190.0±95.1 ml. There were 2 patients who underwent conversion to thoracotomy. There was no in-hospital and 30-day mortality. Overall complications were observed in 24 patients (34.3%), of whom 6 patients (8.6%) had anastomotic leakage. The median length of hospitalization was 9.0 (interquartile range, IQR, 5.0) days. The mean tumor size was 3.2±1.5 cm, and R0 resection was achieved in all patients. The mean number of totally dissected lymph nodes was 19.3±8.7. Conclusion RAILE is safe and technically feasible with satisfactory perioperative outcomes.
ObjectiveTo summarize the clinical experience of 180 general surgeries under da Vinci surgical system. MethodsFrom January 2009 to October 2010, 180 patients with hepatopancreaticobiliary and gastrointestinal disease underwent robotic surgeries by using da Vinci surgical system. The case distribution, intra-and post-operative data were analyzed. ResultsA total of 171 patients had underwent total robotic surgeries and nine patients converted to hand-assisted procedure (5.0%, 9/180). The surgery for hepatic portal was performed in 63 cases of patients, including surgery for hilar cholangiocarcinoma in 36 cases, gallbladder carcinoma in 10 cases, complex calculus of intrahepatic duct in 12 cases, and iatrogenic biliary duct injury in 5 cases. The pancreatic surgery was performed in 44 cases of patients, including pancreatoduodenectomy in 16 cases, distal pancreatectomy in 6 cases, medial pancreatectomy in 1 case, pancreatic cyst-jejunum anastomosis in 1 case, and palliative surgery in 20 cases. Hepatic surgery was in 19 cases and gastrointestinal surgery in 12 cases of patients. Other procedures were in 42 cases of patients, including common bile duct exploration and removing the stone, retroperitoneal lymph nodes dissection, and splenectomy, etc. All of ten cases of patients with obstructive suppurative cholangitis received emergency surgery by the robot and postoperative infection symptoms were controlled, and shock was corrected quickly. No death occurred during the perioperative period. Postoperative complications occurred in 12 cases (6.7%, 12/180) and 2 cases died (1.1%, 2/180). Conclusionsda Vinci surgical system can carry out all kinds of general surgery, especially complicated and difficult hepatobiliary and pancreatic surgery, which improves the development of minimally invasive surgery.
Objective To compare the perioperative outcomes of atypical segmentectomy between robotic-assisted thoracoscopic surgery (RATS) and conventional video-assisted thoracoscopic surgery (VATS) in early-stage non-small cell lung cancer (NSCLC). MethodsThe data of patients who underwent minimally invasive anatomic atypical segmentectomy in our hospital from October 2016 to December 2021 were collected. These patients were divided into a RATS group and a VATS group according to the operation method. Propensity score (PS) matching was used to select patients with close clinical baseline characteristics, and the perioperative results of the two groups were compared. ResultsA total of 1 048 patients were enrolled, including 320 males and 728 females, with a mean age of 53.51±11.13 years. There were 277 patients in the RATS group and 771 patients in the VATS group. After 1∶1 PS matching, 277 pairs were selected. Both groups were well balanced for age, sex, smoking history, body mass index, Charlson comorbidity index, pulmonary function, tumor size, tumor location, and histological type. All patients were R0 resection, and there were no deaths within 30 days after surgery. The RATS group had shorter operative time [85 (75, 105) min vs. 115 (95, 140) min, P<0.001] and less blood loss [50 (30, 100) mL vs. 60 (50, 100) mL, P=0.001]. There were no statistical differences between the two groups in lymph node resection, conversion to thoracotomy, thoracic drainage time, total amount of thoracic drainage or postoperative complications (P>0.05). ConclusionBoth RATS and VATS atypical segmentectomies are safe and feasible for early-stage NSCLC. RATS can effectively shorten the operative time, and reduce blood loss.
ObjectiveTo investigate the safety and efficacy of robot-assisted pulmonary lobectomy using da Vinci S System, and explore its advantages in minimally invasive surgery. MethodsFrom May 2009 to May 2013, 12 patients with suspected non-small cell lung cancer (NSCLC) underwent robot-assisted lobectomy using da Vinci S System in Shanghai Chest Hospital. There were 6 male and 6 female patients with their age of 40-61 (52±8) years. Robotic instruments were used through a 12-mm observation port, two 8-mm thoracoscopic ports and a 12 to 40 mm utility incision without rib spreading. Perioperative data of the patients were collected and analyzed. ResultsAll the 12 patients successfully received surgical resection. All types of lobectomy were performed, and all the procedures were radical resection. Each patient received 4 to 9 (5±1) stations of lymph node dissection. None of the patients underwent conversion to thoracotomy. There was no perioperative mortality or morbidity in this group. Chest drainage duration was 3-11 (8±7) days. Length of hospital stay was 6 to 18 (14±8) days. Operation time was 60 to 280 (185±78) minutes. Intraoperative blood loss was 20 to 200 (108±71) ml. There was no perioperative blood transfusion. ConclusionsRobot-assisted lobectomy is initially proven a safe and effective procedure with enhanced visualization and better dexterity and stability than video-assisted thoracopscopic surgery. Thus surgical indications for robot-assisted lobectomy can be widened. Robot-assisted lobectomy is an important choice in the new age of minimally invasive thoracic surgery.
ObjectiveTo summarize the clinical experience of 58 operations for biliary malignant tumor with da Vinci surgical system. MethodsFrom January 2009 to October 2010, 180 patients with hepatopancreaticobiliary and gastrointestinal disease underwent robotic surgeries by using da Vinci surgical system, including 58 patients with biliary malignant tumor. The case distribution, intra and postoperative data were analyzed. ResultsOf 58 patients, 3 patients with intrahepatic bile duct cystadenocarcinoma received wedge resections of liver. In 36 patients with hilar cholangiocarcinoma, anatomical left hemihepatectomies were performed in 3 cases, resection of extrahepatic duct and gallbladder bridge type biliary revascularization in 3 cases, resection of extrahepatic duct and biliary-enteric Roux-en-Y anastomosis in 14 cases, tumor resection and revascularization of hepatic portal bile duct in 1 case, palliative external drainage of intrahepatic bile duct in 5 cases, and Y-internal drainage of hepatic portal in 10 cases. In 10 patients with gallbladder carcinoma, resection of extrahepatic duct and gallbladder and biliaryenteric Roux-en-Y anastomosis in 2 cases, cholecystectmy in 3 cases, cholecystectmy and external drainage of intrahepatic bile duct in 1 case, cholecystectmy and Y-internal drainage by suspension of hepatic portal in 4 cases. A patient with middle bile duct cancer received radical resection of cholangiocarcinoma and biliary-enteric Roux-en-Y anastomosis. Of 8 patients with distal bile duct cancer, Whipple procedure were performed. Of 58 patients, 2 cases converted to hand-assistant procedure (3.4%). For all patients, operation time was (6.18±1.71) h, blood loss was (116.66±56.06) ml, blood transfusion was (85.55±38.28) ml, ambulation time was (9.10±2.91) h, feeding time was (14.95±4.35) h, and hospital stay was (12.81±4.29) d. Postoperative complications occurred in 8 cases (13.8%), including bile leakage (3 cases), wound bleeding (1 case), pancreatoenteric anastomotic leakage (2 cases), pulmonary infection (1 case), and renal failure (1 case). Of these 8 cases, 6 cases recovered smoothly and 2 cases die of severe pulmonary infection and renal failure after conservative treatment (3 or 4 weeks), therefore, the mortality of patients was 3.4%. In 36 patients with hilar cholangiocarcinoma, 19 cases died (on 2 monthes 4 cases, on 6 monthes 5 cases, on 10 monthes 8 cases, and on 12 monthes 2 cases after operation), 11 cases survival well (gt;26 monthes 4 cases, gt;22 monthes 3 cases, and gt;19 monthes 4 cases), and 6 cases required hospitalization. Of 10 patients with gallbladder carcinoma, 7 cases died (on 3 monthes 1 case, on 5 monthes 1 case, on 8 monthes 1 case, on 11 monthes 3 cases, and on 12 monthes 1 case after operation) and 3 cases survival (gt;17 monthes 2 cases, gt;13 monthes 1 case). In 8 cases undergoing pancreatoduodenectomy, 5 cases died (on 4 monthes 2 cases, on 6 monthes 2 cases, and 10 monthes 1 case after operation) and 3 cases survived well over 2 years. Three patients with intrahepatic bile duct cystadenocarcinoma survived over 1 year. Conclusionsda Vinci surgical system can carry out all kinds of surgery for biliary malignant tumor, especially prominent in the complicated surgeries for hepatic portal, which breaks through the restricted area of laparoscope in hepatobiliary malignant tumor.
ObjectiveTo summarize the application and research progress of robotic-arm in total knee arthroplasty (TKA).MethodsRelevant literature at home and abroad was extensively reviewed to analyze the advantages and disadvantages of robotic-arm assisted TKA (RATKA).ResultsAccurate reconstruction of lower extremity alignment and rotation alignment, accurate osteotomy and implant prosthesis in TKA are very important to improve the effectiveness and prolong the life of the prosthesis. Traditional TKA deviations occur in key links such as osteotomy due to operator’s operation. RATKA solves the above problems to a certain extent and can assist accurate osteotomy and implant prosthesis, and protect the soft tissues around the knee joint. Patients’ satisfaction after RATKA is high, and the operator’s learning curve is shorter, which improves the efficiency of the operation. But it also has disadvantages such as prolonged operation time, increased complications and medical costs.ConclusionPreliminary clinical application studies have shown that RATKA has satisfactory effectiveness, but its definite advantages compared with traditional TKA need to be confirmed by a large number of randomized controlled trials and long-term follow-up.