west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Ultrasonic" 31 results
  • VALUE OF CT AND COMPLEMENTAL ULTRASONIC IMAGING IN THE DIAGNOSIS OF ACUTE INTESTINAL OBSTRUCTION

    Objective To evaluate CT and ultrasonic imaging as a diagnostic means of acute intestinal obstruction. Methods Acute intestinal obstruction of 30 patients diagnosed by preoperative CT scanning and ultrasonic imaging was retrospectively viewed, compaired with intraoperative and pathologic findings.Results The overall accuracy of CT for detection of obstruction was 86.7% (26/30),CT and ultrasonic imaging was 93.3% (28/30). Conclusion CT with ultrasonic imaging is of great advantages for senile patients especially having malignant tumors and for patients with intestinal intussuception. CT with ultrasonic imaging is found to be reliable for diagnosing ileolithiasis and abdominal abscess and mesentery vein thrombosis, but is less sensitive in cases of bowel torsion.

    Release date:2016-09-08 02:00 Export PDF Favorites Scan
  • EXPERIMENTAL STUDY OF THE MECHANISM ON BLOOD SUPPLY TO DELAYED SEPARATED SKIN FLAP BY ULTRASONIC DOPPLER

    In order to investigate the mechanism of blood supply to the delayed separated skin flap and the time and criteria for its transfer, 5 smallsized Banna pigs were selected to produce 14 skin flaps. In the experimental group the skin flap on one side was made from the middle of the back having an extrathin steel sheet intervened between the flap and the soft tissue of the back whereas the flap on the opposite side without a steel sheet intervened was served as the selfcontrol. The skin flaps were examined 3,7,10 and 20 days after the operation and 3,7 and 10 days after transfer, respectively, by (1) gross observation; (2) ultrasonic Doppler; (3) superficial skin temperature measurement and; (4) histomorphological examination. In the experimentalgroup the survival rate of the flap was 100 percent whereas in the control group all of the flaps had necrosis from 30 to 50 percent after the flap being transfered. In the experimental group, the echo sound from the arterial blood flow from ultrasonic Doppler was heard at the pedicle 7 days after the operation, and as time elapsed, the echo sound spread distally, whereas in the controls no echo sound could be heard over the skin flap. There was significant difference statistically between the experimental and control groups in the temperature of the flaps while the flaps were being transferred (P lt; 0.01). The external diameters of the blood vessels in the central area of the skin flap were larger in the experimental group, 0.8 to l.2mm in comparison to 0.4mm.

    Release date:2016-09-01 11:08 Export PDF Favorites Scan
  • Advances in the prevention and treatment of venous thrombotic diseases after spinal cord injury

    Spinal cord injury (SCI) patients are high-risk groups of hospitalized patients with venous thrombosis embolism (VTE). VTE is one of the important causes of inpatients’ unexpected death and perioperative accidental death, so SCI patients with VTE deserve special attention. In recent years, the risk factors, epidemiological characteristics, pathogenesis, and prevention of VTE have been further understood. We also have a more comprehensive and in-depth understanding of the treatment of venous thrombosis, including general prevention, drug, interventional surgery, rehabilitation, etc. Non-invasive examination, new therapeutic technologies, and new oral anticoagulant drugs have also greatly promoted the prevention and treatment of VTE. Meanwhile, prevention system of VTE has been developed from single subject work gradually to the multidisciplinary, multiple grades and doctor-patient cooperation mode, is no longer just dominated by clinical departments, but dominated by hospitals and even higher level department, and a more scientific and effective management mode has being under construction, all of these will further optimize the clinical prevention and treatment of venous thrombosis.

    Release date:2019-05-23 04:49 Export PDF Favorites Scan
  • TOTAL MESORECTAL EXCISION WITH ULTRASONIC SCALPEL UNDER THE LAPAROSCOPE IN THE OPERATION OF RECTAL CARCINOMA

    Objective To introduce the total mesorectal excision (TME)under the laparoscope and with the ultrosonic scalpel. Methods Under the laparoscope and with the ultrosonic scalpel, total mesorectal excision in 3 patients was performed. In operation, alone the parietal layer of pelvic fascia and inside the automatic nerve trunk, the mesorectum was excised with the ultrasonic scalpel. Results Three patients got final recovery, no damage to the viscera in operation occurred. Average hemorrhage amount was about 100ml. Intestinal function recovered within 24 hours, average in hospital time was 10.3 days. After 4 months, 3 patients got good living quality without recurrence and metastasis.Conclusion TME under the laparoscope is a new progress of less damageable operation. Compared with the traditional open laparotomy,it has some advantage. But it requires high technology and expensive equipments, and the case is still very limited in use.

    Release date:2016-08-28 05:30 Export PDF Favorites Scan
  • Effects of transcranial magneto-acoustic electrical stimulation on calcium signals in prefrontal nerve clusters

    Transcranial magneto-acoustic electrical stimulation (TMAES) is a novel method of brain nerve regulation and research, which uses induction current generated by the coupling of ultrasound and magnetic field to regulate neural electrical activity in different brain regions. As the second special envoy of nerve signal, calcium plays a key role in nerve signal transmission. In order to investigate the effect of TMAES on prefrontal cortex electrical activity, 15 mice were divided into control group, ultrasound stimulation (TUS) group and TMAES group. The TMAES group received 2.6 W/cm2 and 0.3 T of magnetic induction intensity, the TUS group received only ultrasound stimulation, and the control group received no ultrasound and magnetic field for one week. The calcium ion concentration in the prefrontal cortex of mice was recorded in real time by optical fiber photometric detection technology. The new object recognition experiment was conducted to compare the behavioral differences and the time-frequency distribution of calcium signal in each group. The results showed that the mean value of calcium transient signal in the TMAES group was (4.84 ± 0.11)% within 10 s after the stimulation, which was higher than that in the TUS group (4.40 ± 0.10)% and the control group (4.22 ± 0.08)%, and the waveform of calcium transient signal was slower, suggesting that calcium metabolism was faster. The main energy band of the TMAES group was 0−20 Hz, that of the TUS group was 0−12 Hz and that of the control group was 0−8 Hz. The cognitive index was 0.71 in the TMAES group, 0.63 in the TUS group, and 0.58 in the control group, indicating that both ultrasonic and magneto-acoustic stimulation could improve the cognitive ability of mice, but the effect of the TMAES group was better than that of the TUS group. These results suggest that TMAES can change the calcium homeostasis of prefrontal cortex nerve clusters, regulate the discharge activity of prefrontal nerve clusters, and promote cognitive function. The results of this study provide data support and reference for further exploration of the deep neural mechanism of TMAES.

    Release date:2022-04-24 01:17 Export PDF Favorites Scan
  • Study on the Correlation between Ultrasonographic Features of HIV/AIDS in Patients with Chronic Viral Hepatitis and CD4+ T Lymphocyte Number

    ObjectiveTo investigate the ultrasonic changes of liver during various immune periods with different number of CD4+ T lymphocytes in HIV/AIDS patients with chronic viral hepatitis. MethodsThe clinical data of 100 patients with chronic viral hepatitis diagnosed between January 2010 and December 2012 were selected. Among them, 50 simple chronic viral hepatitis patients were designated as the control group, and the other 50 HIV/AIDS patients with chronic viral hepatitis were regarded as the experimental group. Ultrasonographic observation was applied on patients of the experimental group according to different immune period based on the number of CD4+ T lymphocytes. Indexes observed included liver size, the edge of liver, capsule of liver and hepatic parenchymal echo. The cross-check analysis was employed between observed results and clinical laboratory results. ResultsAbnormal changes of the experimental group were shown on the ultrasound observation of liver in different CD4+ T lymphocyte count immune periods, including enlargement of the liver, slightly blunt liver margin, slightly thick capsule, dense and uniform, slightly rough and not so uniform, or rough and not uniform hepatic parenchymal echo. There was no significant difference in ultrasonic changes of liver between the two groups when the CD4+ T cell number was over 300/mm3. However, the difference was significant when the CD4+ T cell number was below 100/mm3. ConclusionLiver abnormalities become more obvious as CD4+ T cell count decreases in HIV/AIDS patients with chronic viral hepatitis. Comprehensive considerations of various liver ultrasound indicators are helpful in clinical evaluation of HIV/AIDS patients with chronic viral hepatitis.

    Release date: Export PDF Favorites Scan
  • The diagnostic value of real-time tissue elastography in differentiating benign and malignant breast tumors

    ObjectiveTo explore the value of ultrasound real-time tissue elastography in the differential diagnosis between benign and malignant breast lesions.Methods A total of 131 cases of patients with breast lesions who underwent ultrasound examination in the People’s Hospital of Guangan City between December 2010 and December 2015 were enrolled as the research object. The patients took conventional color Doppler ultrasound diagnosis firstly, and then took ultrasound real-time tissue elastography diagnosis. The lesions were scored with improved 5-scoring system respectively. By the strain ratio measure method equipped with the ultrasonic machine, strain ratio of the lesion was calculated, with 3.08 as the cut-off pont. The results were campared with the pathologic diagnosis.ResultsThere were 182 breast lumps in the 131 patients. The conventional ultrasound examination detected 128 benign lesions and 54 malignant lesions. By ultrasound real-time tissue elastography examination, there were 121 benign tumors and 61 malignant tumors. For the benign tumors, the elasticity imaging score was 1.74±0.81, and the elastic strain rate ratio was 1.83±1.22; for the malignant tumors, the elasticity imaging score was 4.45±0.59, and the elastic strain rate ratio was 8.68±5.58. The 182 breast lumps were all removed by surgical resection, and the pathologic examination showed there were 121 benign lesions and 61 malignant lesions. The accuracy, sensitivity and specificity of conventional ultrasonic diagnosis of breast malignant lesions was 76.4%, 59.0% and 85.1%, respectively; while the indexes of ultrasound real-time tissue elastography diagnosis of breast malignant lesions was 96.7%, 95.1% and 97.5%, respectively, and the differences were statistically significant (P<0.05).ConclusionReal-time tissue elastography is helpful in the differential diagnosis between malignant and benign breast lesions.

    Release date:2017-07-21 03:43 Export PDF Favorites Scan
  • Safety and effectiveness of ultrasonic osteotome in posterior cervical laminectomy decompression and fusion

    ObjectiveTo explore the safety of ultrasonic osteotome used in posterior cervical laminectomy decompression surgery and its effect on surgical outcome. Methods A clinical data of 52 patients with ossification of posterior longitudinal ligament of cervical spine (C-OPLL) undergoing posterior cervical laminectomy decompression and fusion (PCLDF) between April 2013 and April 2017 was retrospectively analysed. The patients were divided into two groups according to whether using the ultrasonic osteotome during operation: group A (20 cases, ultrasonic osteotome group) and group B (32 cases, traditional gun-clamp decompression group). There was no significant difference in gender, age, body weight, height, preoperative hemoglobin, and Japanese Orthopedic Association (JOA) score between the two groups (P>0.05). The operation time, intraoperative blood loss, postoperative drainage volume, hospitalization time, complications, hemoglobin at 1 day after operation, and JOA score at 6 months after operation were recorded and compared between the two groups, and the improvement rate of JOA was calculated. Results The operation time and intraoperative blood loss in group A were significantly less than those in group B (P<0.05); there was no significant difference in the drainage volume and hospitalization time between the two groups (P>0.05). The hemoglobin of group B was slightly higher than that of group A at 1 day after operation, but there was no significant difference between the two groups (t=–1.260, P=0.214). All the patients were followed up 6-10 months (mean, 7.6 months). No serious complications such as C5 nerve paralysis, dural tear, infection, epidural hematoma, deep venous thrombosis, pulmonary embolism, transfusion allergy, or shock occurred during and after operation. The JOA scores of the two groups were significant improved at 6 months after operation when compared with preoperative scores (P<0.05), and there was no significant difference in JOA score and improvement rate between the two groups at 6 months after operation (P>0.05). Conclusion Compared with the traditional gun-clamp decompression, the effectiveness of PCLDF in treatment of C-OPLL by using ultrasonic osteotome is comparable, but the latter can effectively reduce the operation time and blood loss.

    Release date:2018-12-04 03:41 Export PDF Favorites Scan
  • RECONSTRUCTION OF DIGITAL AVULSION WITH PRE-FABRICATED SUBDERMAL VASCULAR NETWORK SKIN FLAP BY ULTRASONIC LIPOSUCTION

    OBJECTIVE: To investigate the clinical application of subdermal vascular network skin flap pre-fabricated by ultrasonic liposuction in reconstruction of digital avulsion. METHODS: Forty-seven injured fingers of 23 cases were treated from June 1997 to February 2000. Conventional abdominal skin flap was elevated, according to the size of digital avulsion, and subcutaneous fat was removed with scissors. Ultrasonic liposuction technology was adopted, in order to minimize the injury of subdermal vascular vessels, to remove the fat particles close to the vascular network. Finally, the pre-fabricated skin flap was used to repair the digital avulsion. The vascular pedicle was severed in 5 to 7 days after operation. The range of skin flap was 4 cm x 3 cm to 8 cm x 7 cm, and the ratio of length and width was (2 to 3) to 1. RESULTS: All the skin flaps were survived. Twenty-one patients were available for postoperative follow-up for 6 to 24 months. The motion of interphalangeal joint achieved functional recovery, and the sensation of pain, temperature and taction recovered well. CONCLUSION: Ultrasonic liposuction does not obviously injure the subdermal vascular network skin flap, it is a simple and safe method for treatment of digital avulsion.

    Release date:2016-09-01 10:21 Export PDF Favorites Scan
  • Application of V-shaped stealth decompression technique using ultrasonic bone scalpel in anterior surgery for adjacent two-level cervical spondylosis

    Objective To evaluate the effectiveness of V-shaped stealth decompression technique using ultrasonic bone scalpel in anterior surgery for adjacent two-level cervical spondylosis. Methods A clinical data of 41 patients with adjacent two-level cervical spondylosis, who admitted between January 2020 and December 2023 and met the selection criteria, was analyzed retrospectively. Among them, 22 cases were treated with anterior cervical discectomy and fusion (ACDF) assisted by V-shaped stealth decompression technique using ultrasonic bone scalpel (group A) and 19 cases with anterior cervical corpectomy and fusion (ACCF) (group B). There was no significant difference between the two groups in age, gender, disease duration, surgical segment, preoperative Japanese Orthopedic Association (JOA) score, neck dysfunction index (NDI), pain visual analogue scale (VAS) score, and the anteroposterior diameter of the spinal canal in the responsibility space of axial CT (P>0.05). The operation time, intraoperative blood loss, postoperative drainage volume, hospital stay, complications during follow-up, JOA score, NDI, and VAS score at last follow-up, and the incidences of intervertebral fusion at 3 months after operation, and cage subsidence at last follow-up were compared between the two groups. Results The operations in the two groups were successfully completed. The operation time, intraoperative blood loss, postoperative drainage volume, and hospital stay in group A were significantly less than those in group B (P<0.05). Two cases (9.1%) in group A and 4 cases (21.1%) in group B developed complications, with no significant difference in the incidence between the two groups (P>0.05). All patients in the two groups were followed up 6-12 months (mean, 9.3 months). There was no significant difference in follow-up time between the two groups (P>0.05). At last follow-up, the JOA score and VAS score in both groups significantly improved when compared with those before operation (P<0.05). The change values of VAS score and the improvement rate of JOA score in group A were significantly superior to group B (P<0.05). There was no significant difference in the change values of NDI and JOA score between the two group (P>0.05). Imaging reexamination showed that the rate of intervertebral fusion at 3 months after operation was significantly higher in group A (81.8%) than in group B (52.6%) (P<0.05), and all patients obtained bony intervertebral fusion at last follow-up. At last follow-up, 2 cases (9.1%) in group A and 11 cases (57.9%) in group B had cage sinking, and the difference in the incidence was significant (P<0.05). No loosening or fracture of internal fixators occurred in all patients. Conclusion Using ultrasonic bone scalpel can transform single vertebral ACCF into two-segment ACDF in anterior cervical spondylosis surgery. The V-shaped stealth decompression technique is safe and efficient, with the advantages of minimal trauma, fewer postoperative complications, and rapid recovery of patients.

    Release date:2025-06-11 03:21 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content