Objective To investigate the outcomes of arthroscopic reduction and internal fixation of tibial eminence avulsion fracture using absorbable double suture anchors. Methods Between February 2007 and August 2009, 18 patients with tibial eminence avulsion fracture were treated with arthroscopic reduction and fixation using absorbable doublensuture anchors. There were 12 males and 6 females with an average age of 30.6 years (range, 17-48 years). The disease causes were traffic accident injury in 4 cases, sport injury in 8 cases, and fall ing from height injury in 6 cases; the locations were left side in 7 cases and right side in 11 cases. The results of the anterior drawer test and Lachman test were positive. According to Meyers-McKeever classification, 10 cases were rated as type II, 7 as type III, and 1 as type IV fractures. The time from injury to treatment was 6-20 days (mean, 10.2 days). Results Incision healed primarily. All the patients were followed up 29.1 months (range, 13-43 months). The X-ray films showed good reduction of fracture immediately after operation and fracture heal ing at 3 months. At the last follow-up, the range of motion of knee was 0-130°. The results of Lachman test and anterior drawer test were negative in 18 cases and 16 cases, repectively; and the results of anterior drawer test were weakly positive in 2 cases. The mean Lysholm score was significantly improved from 53.9 ± 6.7 preoperatively to 91.6 ± 4.2 postoperatively (t=22.100, P=0.000). The Inter national knee Documentation Commitee (IKDC) 2000 subject score improved from 58.1 ± 3.7 preoperatively to 92.8 ± 5.9 postoperatively (t=20.700, P=0.000). Conclusion Arthroscopic treatment using absorbable double suture anchors for tibial eminence avulsion fracture can provide satisfactory reduction, stable fixation, and good heal ing of the avulsed fragment, which is a minimally-invasive, simple, and effective treatment for patients with tibial eminence avulsion fracture.
Objective To investigate the effectiveness of arthroscopically assisted treatment of acute tibial insertion avulsion fracture of the posterior cruciate ligament (PCL) via posteromedial incision. Methods Between January 2010 and January 2012, 22 patients with acute tibial insertion avulsion of the PCL underwent arthroscopic reduction and fixation via posteromedial incision. There were 14 males and 8 females with an average age of 32 years (range, 18-48 years). The injury causes included traffic accident injury in 14 cases, sport injury in 4 cases, and falling injury in 4 cases. The disease duration ranged from 7 to 16 days (mean, 10 days). Of 22 patient, 14 had simple PCL injury, 6 had PCL injury with meniscus injury, and 2 with cartilage injury. The results of posterior drawer test were positive in all patients. The preoperative Lysholm score was 51.1 ± 3.4. Results All incisions healed by first intention without infection, deep venous thrombosis of lower limbs, or vessel and nerve injuries. All patients were followed up 12-24 months (mean, 18.4 months). X-ray films showed that all fractures healed with the healing time of 2-4 months (mean, 3 months). The Lysholm score was improved to 96.0 ± 2.2 at 6 months after operation, showing significant difference when compared with preoperative score (t=43.020, P=0.000). Conclusion Arthroscopically assisted treatment of acute tibial insertion avulsion fracture of the PCL via posteromedial incision is a safe, easy, and effective method.
ObjectiveTo evaluate the clinical outcome of stellated plate fixation of olecranal avulsion fracture. MethodsA retrospective analysis was made on the clinical data from 24 cases of olecranal avulsion fracture treated with stellated plate between April 2007 and April 2012. There were 13 males and 11 females, with an average age of 32 years (range, 18-65 years). The causes of injury included falling injury (14 cases), sports injury (7 cases), and machine injury (3 cases). The left elbow was involved in 4 cases and the right side in 20 cases. The average disease duration was 11 hours (range, 3 hours-2 days). According to Colton's classification criteria, all cases were classified as type Ⅱ A (avulsion fracture). One case had supracondylar humeral avulsion fracture, and 15 cases had triceps tendon tears. ResultsAll the cases obtained healing of incision by first intention, without infection and ulnar nerve injury. The average follow-up period was 24 months (range, 18-48 months). All fractures healed after 6-10 weeks (mean, 7 weeks). According to Morrey's elbow performance score, the results were excellent in 17 cases, good in 4 cases, and fair in 3 cases, with an excellent and good rate of 87.5%. There was no significant difference in the elbow range of motion (ROM) between the injured side (136.0±16.2)° and normal side (143.1±2.9)° (t=2.007, P=0.052). The ROM of normal elbow was significantly larger than that of the injured side in 3 patients who achieved fair results (t=2.820, P=0.048), but no significant difference was found in patients who achieved excellent and good results (P>0.05). ConclusionThe stellated plate has good clinical outcome in treatment of olecranal avulsion fracture, which has advantages of simple operation, firm fixation, and early functional exercise.
Objective To analyze the effectiveness of minimally invasive safe approach of the knee joint in the treatment of avulsion fractures of the tibial insertion of the posterior cruciate ligament (PCL). Methods The clinical data of 26 patients with avulsion fractures of tibial insertion of PCL treated with open reduction and internal fixation via minimally invasive safe approach of the knee joint between February 2019 and March 2022 were analyzed retrospectively. There were 18 males and 8 females with an average age of 45.5 years (range, 33-58 years). The causes of injury were traffic accident in 14 cases, falling from height in 7 cases, and sports injury in 5 cases. There were 15 cases of left knee and 11 cases of right knee. The preoperative Lysholm score of knee joint was 34.4±7.3 and the flexion range of motion of knee joint was (69±12)°. According to Meyers classification, there were 8 cases of type Ⅱ and 18 cases of type Ⅲ. The time from injury to operation ranged from 1 to 5 days, with an average of 2 days. ResultsThe operation time was 40-70 minutes, with an average of 55 minutes; the intraoperative blood loss was 10-30 mL, with an average of 15 mL. Delayed incision healing occurred in 1 case after operation, and the incision healed after conservative treatment, and the incisions of the other patients all healed by first intention. Postoperative X-ray films showed satisfactory fracture reduction. All 26 patients were followed up 3-30 months, with an average of 22 months. No complication such as neurovascular injury, infection, and knee extension disorder occurred after operation. X-ray films at 3 months after operation showed that all fractures healed without displacement of the fracture ends; the posterior drawer test was negative. At last follow-up, the flexion range of motion of knee joint was (120±9)°, the Lysholm score was 90.7±3.8, which were significantly improved when compared with those before operation (t=16.376, P<0.001; t=47.665, P<0.001). Conclusion The minimally invasive safe approach of the knee joint for the treatment of PCL tibial insertion avulsion fractures is easy to operate, with minimal surgical trauma, safe and reliable approach, and satisfactory recovery of knee joint function after operation.
ObjectiveTo investigate the effectiveness of open reduction by mini incision and absorbable screw internal fixation for the treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture. MethodsBetween January 2006 and July 2012, 90 patients (90 knees) with ACL tibial eminence avulsion fracture were treated. There were 58 males and 32 females, aged from 10 to 58 years with an average of 33.7 years. The causes of injury were traffic accident injury in 60 cases, sports injury in 22 cases, and falling injury in 8 cases. The disease duration was 1-365 days with a median of 106 days. Combined injuries included 14 cases of meniscus injury, 5 cases of medial collateral ligament injury, and 3 cases of avulsion fracture of the anterior horn of the lateral meniscus. All patients underwent open reduction by mini incision and internal fixation with absorbable screw. Postoperative rehabilitation exercise was performed. ResultsTwo patients had delayed healing of incision, and others obtained primary healing. All the patients were followed up 6-72 months (mean, 40.1 months). X-ray examination showed that bone union was achieved in all patients at 3-12 months after operation; nail tail came off in 7 cases at 4-13 months after operation, and the nail tail was taken out under arthroscopy. At 6-12 months after operation, the range of motion (ROM), Tegner score, Lysholm score, and International Knee Documentation Committee (IKDC) score were significantly increased when compared with preoperative ones (P < 0.05). ConclusionA combination of open reduction by mini incision and absorbable screw internal fixation for the treatment of ACL tibial eminence avulsion fracture has the advantages of easy operation, firm fixation, and satisfactory functional rehabilitation, so it is a safe and effective method for the treatment of ACL tibial eminence avulsion fracture.
Objective To investigate the effectiveness of one-stage closed reduction and elastic compression fixation with double Kirschner wires for Wehbe-Schneider types ⅠB and ⅡB bony mallet fingers. Methods Between May 2017 and June 2020, 21 patients with Wehbe-Schneider type ⅠB and ⅡB bony mallet fingers were treated with one-stage closed reduction and elastic compression fixation using double Kirschner wires. There were 15 males and 6 females with an average age of 39.2 years (range, 19-62 years). The causes of injury were sports injury in 9 cases, puncture injury in 7 cases, and sprain in 5 cases. The time from injury to admission was 5-72 hours (mean, 21.0 hours). There were 2 cases of index finger injury, 8 cases of middle finger injury, 9 cases of ring finger injury, and 2 cases of little finger injury. The angle of active dorsiflexion loss of distal interphalangeal joint (DIPJ) was (40.04±4.02)°. According to the Wehbe-Schneider classification standard, there were 10 cases of typeⅠB and 11 cases of type ⅡB. The Kirschner wire was removed at 6 weeks after operation when X-ray film reexamination showed bony union of the avulsion fracture, and the functional exercise of the affected finger was started. Results The operation time was 35-55 minutes (mean, 43.9 minutes). The length of hospital stay was 2-5 days (mean, 3.4 days). No postoperative complications occurred. All patients were followed up 6-12 months (mean, 8.8 months). X-ray films reexamination showed that all avulsion fractures achieved bony union after 4-6 weeks (mean, 5.3 weeks). Kirschner wire was removed at 6 weeks after operation. After Kirschner removal, the visual analogue scale (VAS) score of pain during active flexion of the DIPJ was 1-3 (mean, 1.6); the VAS score of pain was 2-5 (mean, 3.1) when the DIPJ was passively flexed to the maximum range of motion. The angle of active dorsiflexion loss of affected finger was (2.14±2.54)°, showing significant difference when compared with preoperative angle (t=52.186, P<0.001). There was no significant difference in the active flexion angle between the affected finger (79.52±6.31)° and the corresponding healthy finger (81.90±5.36)° (t=1.319, P=0.195). At 6 months after operation, according to Crawford functional evaluation criteria, the effectiveness was rated as excellent in 11 cases, good in 9, and fair in 1, with an excellent and good rate of 95.24%. Conclusion For Wehbe-Schneider typesⅠB and ⅡB bony mallet fingers, one-stage closed reduction and elastic compression fixation with double Kirschner wires can effectively correct the deformity and has the advantages of simple surgery, no incision, and no influence on the appearance of the affected finger.
ObjectiveTo compare the effectiveness of open reduction of posterior cruciate ligament (PCL) avulsion fracture at tibial insertion of knee joint with absorbable screws fixation and absorbable screw combined with suture anchor fixation. Methods The clinical data of 26 patients with PCL avulsion fracture at tibial insertion who met the selection criteria between March 2015 and October 2021 were retrospectively analyzed. Among them, 14 patients were fixed with simple absorbable screw (group A), and 12 patients were fixed with absorbable screw combined with suture anchors (group B). All patients were confirmed by X-ray film, CT, or MRI preoperatively, and got positive results in preoperative posterior drawer tests. There was no significant difference in gender, age, side of affected limb, time from injury to operation, comorbidities, and preoperative Meyers & McKeever classification, Lysholm score, and International Knee Documentation Committee (IKDC) score between the two groups (P>0.05). The operation time and postoperative complications were recorded and compared between the two groups. At last follow-up, Lysholm score and IKDC score were used to evaluate the improvement of knee function. ResultsThere was no significant difference in operation time between the two groups (P>0.05). All incisions healed by first intention, and no complication such as vascular and nerve injury or venous thrombosis occurred. All 26 patients were followed up 9-89 months, with an average of 55.3 months. The follow-up time of group A and group B was (55.7±23.2) and (56.8±29.3) months, respectively, with no significant difference (t=−0.106, P=0.916). Radiographs showed bone healing in both groups at 3 months after operation, and no complication such as infection and traumatic arthritis occurred. At last follow-up, the posterior drawer test was negative in both groups, and the Lysholm score and IKDC score significantly improved when compared with the pre-operative values (P<0.05). However, there was no significant difference in the improvement value between the two groups (P>0.05). ConclusionFor PCL avulsion fracture at tibial insertion of the knee joint, the open reduction and absorbable screw combined with suture anchor fixation can achieve reliable fracture reduction and fixation, which is conducive to the early rehabilitation and functional exercise, and the postoperative functional recovery of the knee joint is satisfactory.
ObjectiveTo study the biomechanical stability of neckwear-knot-loop-ligature fixation for tibial eminence avulsion fractures by comparing with cannulated screw fixation and suture anchor fixation. MethodsTwenty-four fresh porcine knee joints were selected. After the model of tibial eminence avulsion fracture (type Ⅲ) was made, 24 samples were randomly divided into 3 groups: neckwear-knot-loop-ligature group (group A), cannulated screw group (group B), and suture anchor group (group C), 8 samples in each group. The Universal electromagnetic and mechanical testing machines were used for the biomechanical tests. After 200 cyclic tests, pull-out test was done until fixation failure. The maximum failure load, yield load, stiffness, and displacement were measured. ResultsFailure mode: the displacement was beyond limit in 8 samples of group A; screws extraction (5 samples) and bone fragment re-fracture (3 samples) were observed in group B; and suture anchor extraction (4 samples), suture rupture (3 samples), and suture thread cutting (1 sample) were found in group C. Biomechanical test: From groups A to C, the maximum failure load and yield load showed significant decreasing tendency (P<0.05), but the displacements showed significant increasing tendency (P<0.05). The stiffness also gradually decreased, but differences was not significant (P>0.05). ConclusionCompared with cannulated screw and suture anchor, neckwear-knot-loop-ligature fixation for tibial eminence avulsion fracture has good biomechanical performance and the advantages of firm fixation and simple operation.
ObjectiveTo evaluate the effectiveness of arthroscopic suture and absorbable screw double fixation for both anterior and posterior cruciate ligament avulsion fractures of tibial insertions. MethodsBetween June 2006 and September 2013, 8 patients with anterior and posterior cruciate ligament avulsion fractures of the tibial eminence underwent arthroscopic treatment with suture and absorbable screw double fixation. There were 5 males and 3 females, with a mean age of 28.9 years (range, 18-43 years). The causes of injury included traffic accident in 5 cases and falling from height in 3 cases. The time from injury to operation was 3-10 days (mean, 6.2 days). The Lysholm knee score, International Knee Documentation Committee (IKDC) score, and Tegner rating scales were used to evaluated the knee function. ResultsPrimary healing of incision was obtained, without infection or deep vein thrombosis. The mean follow-up period was 42.4 months (range, 24 to 65 months). At 3 months after operation, X-ray films showed good reduction and healing of fracture. The anterior and posterior drawer tests were negative. The knee range of motion was normal (0-125°), and it recovered to preoperative level in 7 cases. The IKDC score, Tegner score, and Lysholm score were significantly improved to 90.4±5.2, 7.5±1.6, and 89.2±3.5 from preoperative 52.1±3.3, 3.3±1.0, and 51.9±3.5 respectively (t=-38.680, P=0.000; t=-39.520, P=0.000; t=-41.150, P=0.000). ConclusionA combined injury of anterior and posterior cruciate ligament avulsion fractures of tibial insertions is rare. Arthroscopic treatment with suture and absorbable screw double fixation is a useful technique to restore tibial avulsion injuries with well-documented radiographic healing, good clinical outcomes, and low complication rates.
ObjectiveTo analyze the possible injury mechanisms in patients with dorsal avulsion fracture of the capitellum combined with medial or posterior medial dislocation of the elbow joint, and to discuss their treatment and prognosis. Methods Retrospective analysis was made on the clinical data of 4 patients with dorsal avulsion fracture of the capitellum combined with medial or posterior medial dislocation of the elbow joint admitted between September 2014 and September 2020, including 3 males and 1 female with an average age of 20.7 years (range, 13-32 years). There were 2 cases of dorsal avulsion fracture of the capitellum combined with medial dislocation of the elbow joint and 2 cases of dorsal avulsion fracture of the capitellum and anterior medial fracture of the coronoid process combined with posterior medial subluxation of the elbow joint. Closed reduction was performed in 3 patients with fresh fracture combined with dislocation, then 2 cases were fixed with tension band and 1 case was fixed with tension band combined with Acumed coronoid anatomic plate. And in patient with old fracture nonunion, the coronoid process was fixed with 1 screw, then the humeral sclerotic bone mass was removed, and finally the lateral collateral ligament was repaired and a hinged external fixator was added. Results All the incisions healed by first intention without early complications such as infection or peripheral nerve injury. The 4 patients were followed up 13-30 months (mean, 20.8 months). The fractures all healed with a healing time of 70-90 days (mean, 79.5 days). At 6 months after operation, heterotopic ossification was seen in the posterior aspect of the right elbow joint in 1 case, and the alkaline phosphatase level was normal (67 U/L); the tension band was removed to clear the heterotopic ossification and the elbow joint was released. The rest of the patients had no heterotopic ossification. At last follow-up, all patients had good functional recovery of the elbow joint, with a Mayo score of 85-100 (mean, 92.5), and the excellent and good rate was 100%. The elbow flexion range of motion was 120°-135°, the extension range of motion was 10°-20°, and the pronation and supination range of motion were all 75°-85°. Conclusion Dorsal avulsion fractures of the capitellum combined with medial or posterior medial dislocation of the elbow may be due to simple varus stress. If an anteromedial coronoid facet fracture also occurs, it may be for the varus posteromedial rotatory instability, which is the opposite mechanism to that of an Osborne-Cotterill lesion. For fresh dorsal avulsion fractures of the capitellum, tension band fixation can be used with good results.