[Abstract]A 70-year-old woman who was admitted to the hospital for post-cardiac surgery panic attack for 4 months. Eight months ago, she was admitted to a local hospital with 7 years of post-activity panic, which worsened for 2 months, and underwent mitral valve replacement+aortic valve replacement+tricuspid valvuloplasty+modified maze procedure+left auriculotomy. Four months after the operation, mitral valve damage appeared, and transcatheter mitral valve replacement was performed in our hospital by apical approach. A case report on the treatment of this patient is presented.
Surgical bioprosthetic valve in the mitral position typically degenerates in 10-15 years, when intervention is required again. In the past, redo surgical mitral valve replacement has been the only treatment choice for such patients suffering from bioprosthetic valve failure, despite the even higher risk associated with redo open-heart surgery. In recent years, transcatheter valve-in-valve implantation in the mitral position has evolved as an reasonable alternative to redo surgery for the treatment of surgical mitral bioprosthetic valve failure. Here we report an 81-year-old female patient with surgical mitral bioprosthetic valve failure, who successfully underwent valve-in-valve transcatheter mitral valve replacement via the transfemoral-transseptal approach. The procedure was successful owing to comprehensive CT imaging work-up, despite the technical challenges associated with bilateral giant atria and small left ventricle.
Objective To summarize the short-term results of valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) in the treatment of bioprosthetic valve failure after aortic valve replacement. Methods We reviewed the clinical data of patients who underwent ViV-TAVI from 2021 to 2022 in the First Affiliated Hospital of Zhengzhou University. The valve function was evaluated by echocardiography before operation, immediately after operation and 3 months after operation. The all-cause death and main complications during hospitalization were analyzed. Results A total of 13 patients were enrolled, including 8 males and 5 females with a mean age of (65.9±8.5) years, and the interval time between aortic valve replacement and ViV-TAVI was (8.5±3.4) years. The Society of Thoracic Surgeons mortality risk score was 10.3%±3.2%. None of the 13 patients had abnormal valve function after operation. The mean transvalvular pressure gradient of aortic valve was decreased (P<0.001), the peak flow velocity of aortic valve was decreased (P<0.001), and the left ventricular ejection fraction was not changed significantly (P=0.480). There were slight perivalvular leakage in 2 patients and slight valve regurgitation in 3 patients. Three months after operation, the mean transvalvular pressure difference and peak flow velocity of aortic valve in 12 patients were significantly decreased compared with those before operation (P≤0.001). Conclusion This study demonstrates that ViV-TAVI for the treatment of bioprosthetic valve failure after aortic valve replacement is associated with favorable clinical and functional cardiovascular benefits, the short-term results are satisfactory.