west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "blood glucose" 20 results
  • Study on the value of blood glucose variability indexes in predicting persistent organ failure after acute pancreatitis

    ObjectiveTo explore the relationship between blood glucose variability index and persistent organ failure (POF) in acute pancreatitis (AP). MethodsWe prospectively included those patients who were diagnosed with AP with hyperglycemia and were hospitalized in the West China Center of Excellence for Pancreatitis of West China Hospital of Sichuan University from July 2019 to November 2021. The patients were given blood glucose monitoring at least 4 times a day for at least 3 consecutive days. The predictive value of blood glucose variability index for POF in patients with AP was analyzed. ResultsA total of 559 patients with AP were included, including 95 cases of POF. Comparing with those without POF, patients with AP complicated by POF had higher levels of admission glucose (11.0 mmol/L vs. 9.6 mmol/L), minimum blood glucose (6.8 mmol/L vs. 5.8 mmol/L), mean blood glucose (9.6 mmol/L vs. 8.7 mmol/L), and lower level of coefficient of variation of blood glucose (16.6 % vs. 19.0 %), P<0.05. Logistic regression analyses after adjustment for confounding factors showed that the risk of POF increased with the increase of admission glucose [OR=1.11, 95%CI (1.04, 1.19), P=0.002], minimum blood glucose [OR=1.28, 95%CI (1.10, 1.48), P=0.001] and mean blood glucose [OR=1.18, 95%CI (1.04, 1.33), P=0.010]; with the higher level of coefficient of variation of blood glucose [OR=0.95, 95%CI (0.92, 0.99), P=0.021], the risk of POF decreased. The results of area under the curve (AUC) of the receiver operator curves showed that AG [AUC=0.787, 95%CI (0.735, 0.840)] had the highest accuracy in predicting POF, with sensitivities of 60.0% and specificities of 84.7%. ConclusionHigh admission glucose, minimum blood glucose, mean blood glucose, and low coefficient of variation of blood glucose were risk factors for the development of POF in patients with hyperglycemic AP on admission.

    Release date:2024-03-23 11:23 Export PDF Favorites Scan
  • Association of the Pro12Ala Polymorphism in PPAR γ2 Gene with Blood Glucose Levels in Patients with Primary Hypertension of Chengdu

    摘要:目的:研究高血压病患者过氧化物酶体增殖物激活受体(PPAR)γ2基因Pro12Ala多态性与血糖水平之间的关系。方法:纳入177名原发性高血压患者,其中空腹血糖(FBG)lt;5.6 mmol/L组65例, FBG≥5.6 mmol/L组112例,收集一般资料;分别测定空腹及餐后2小时血糖、胰岛素;对PPARγ2 基因Pro12Ala多态性与各临床变量的关系进行研究。结果:FBGlt;5.6 mmol/L组和FBG≥5.6 mmol/L组Pro和Ala等位基因频率分别为0.333,0.034及0.602,0.031;PP和PA基因型频率分别为0.299,0.068及0.571,0.062;无AA型纯合子。以体重指数(BMI)分层后,BMIlt;25组内,FBG与PPARγ2基因型相关(P=0.029)。以基因型分组比较,PA组空腹血糖水平和胰岛素抵抗指数都低于PP组(Plt;0.05)。结论:成都地区高血压患者PPARγ2基因Pro12Ala多态性与空腹血糖水平相关,且携带Ala基因者空腹血糖水平较低,胰岛素抵抗较轻,推测该突变可能有减轻高血压病患者胰岛素抵抗,改善糖代谢异常的作用。Abstract: Objective:To study the association between the Pro12Ala polymorphism in peroxisome proliferatorsactivated receptorγ2 ( PPARγ2 ) gene and blood glucose levels in patients with primary hypertension. Methods:The Pro12Ala polymorphism in PPARγ2 was determined by polymerase chain reactionrestriction fragment length polymorphism (PCRRELP) in 177 subjects with primary hypertension of the Han people in Chengdu of China, including 65 subjects with fasting blood glucose (FBG)lt;5.6 mmol/L and 112 subjects with FBG≥5.6 mmol/L; the clinical characteristics including height, weight, OGTT(0h and 2h) of the subjects were detected and the realationship between the Pro12Ala polymorphism and the clinical characteristics were analysed. Results: The allele frequencies in the group with FBGlt;5.6 mmol/L and FBG≥5.6 mmol/L were 0.333, 0.602 for Pro and 0.034, 0.031 for Ala. The genotype frequencies were 0.299, 0.571 for PP and 0.068, 0.062 for PA, and there was no AA. In the group with BMIlt;25, the Pro12Ala polymorphism was associated with FBG (P=0.029). the Ala allele had a negative relationship to the FPG and insulin resistance index (IRI) (Plt;0.05).Conclusion: The data showed that the Pro12Ala polymorphism was associated with FBG., and The allele Ala probably had benefits to glycometabolic disturbance in patients with primary hypertension by declining insulin resistance.

    Release date:2016-09-08 10:12 Export PDF Favorites Scan
  • Analysis of Influence Factors of Gallstone

    ObjectiveTo explore the influence factors of gallstone. MethodsClinical data of 511 patients who were admitted to our hospital from Apr. 2015 to Apr. 2016 were retrospectively analyzed. ResultsOf 511 patients, there were 274 patients with gallstone (gallstone group) and 237 patients without gallstone (control group). Univariate analysis results showed that, no significant difference of age, gender, and diabetes was found between gallstone group and control group (P > 0.050), but the levels of serum total cholesterol (TC), triglyceride (TG), low density lipoprotein (LDL-C), and fasting blood glucose (FBG) were significantly higher in patients of gallstone group (P < 0.050), but the level of serum high density lipoprotein (HDL-C) was significantly lower in patients of gallstone group (P=0.001). Logistic regression results showed that four factors including diabetes〔OR=4.491; 95% CI is (2.021, 9.976); P < 0.001〕, the serum TC〔OR=2.548; 95% CI is (1.944, 3.338); P < 0.001〕, HDL-C〔OR=0.115; 95% CI is (0.056, 0.237); P < 0.001〕, and FBG〔OR=1.277; 95% CI is (1.086, 1.502); P=0.003〕 entered the final regression model after controlling confounding factors. The results showed that patients who combined with diabetes, high levels of serum TC and FBG, and low level of serum HDL-C, had higher ratio of galls-tone. ConclusionDiabetes, high-level of serum TC and FBG, low-level of serum HDL-C were risk factors of gallstone.

    Release date:2016-12-21 03:35 Export PDF Favorites Scan
  • Study on noninvasive blood glucose detection method using the near-infrared light based on particle swarm optimization and back propagation neural network

    Most of the existing near-infrared noninvasive blood glucose detection models focus on the relationship between near-infrared absorbance and blood glucose concentration, but do not consider the impact of human physiological state on blood glucose concentration. In order to improve the performance of prediction model, particle swarm optimization (PSO) algorithm was used to train the structure paramters of back propagation (BP) neural network. Moreover, systolic blood pressure, pulse rate, body temperature and 1 550 nm absorbance were introduced as input variables of blood glucose concentration prediction model, and BP neural network was used as prediction model. In order to solve the problem that traditional BP neural network is easy to fall into local optimization, a hybrid model based on PSO-BP was introduced in this paper. The results showed that the prediction effect of PSO-BP model was better than that of traditional BP neural network. The prediction root mean square error and correlation coefficient of ten-fold cross-validation were 0.95 mmol/L and 0.74, respectively. The Clarke error grid analysis results showed that the proportion of model prediction results falling into region A was 84.39%, and the proportion falling into region B was 15.61%, which met the clinical requirements. The model can quickly measure the blood glucose concentration of the subject, and has relatively high accuracy.

    Release date:2022-04-24 01:17 Export PDF Favorites Scan
  • Accuracy of Newer-generation Home Blood Glucose Meter in Patients with IGR and Newly-diagnosed Type 2 Diabetes Mellitus

    Objective To evaluate the accuracy of newer-generation home blood glucose meter (Accu-Check? Integra) in patients with impaired glucose regulation (IGR) and newly-diagnosed type 2 diabetes mellitus. Methods A cross-sectional study was performed on 109 cases with newly-diagnosed type 2 diabetes or IGR who were asked to take oral glucose tolerance test (OGTT), while paired samples, that were Accu-Check? Integra in capillary blood glucose (CBG) and laboratory glucose in venous plasma glucose (VPG ), were taken simultaneously. Taking VPG as the reference value, the accuracy of the home glucose meter was assessed according to the international standardization organization (ISO), including, the accuracy was studied by means of Median absolute difference (Median AD) and Median absolute relative difference (Median RAD), the consistency of CBG and VPG was studied by Clarke Error Grid analysis, the correlation of CBG and VPG was analyzed according to liner regression analysis, and the sensitivity and specificity for hyperglycemia were also calculated. Results There were 292 VPG values paired with CBG values, among which 93.49% of CBG values met ISO home glucose meter criteria, the median AD was 7.2 mg/dL, and the median RAD was 4.76%. Paired glucose measurements from the Accu-Check Integra meter and laboratory glucose measurement demonstrated that 100% of paired points in the overall subject population fell in zones A and B of the Clarke Error Grid. The CBG value was well correlated to VPG value in the overall level, and the sensitivity and specificity were 94.6% and 95.7% respectively for hyperglycemia. Conclusion The newer-generation home blood glucose meter (Accu-Check? Integra) demonstrates a high degree of accuracy, and it can precisely report the real value of blood glucose.

    Release date:2016-09-07 10:59 Export PDF Favorites Scan
  • Research progress on relation between blood glucose regulating hormones and gastric cancer

    ObjectiveTo understand the relation between blood glucose regulating hormones and gastric cancer, so as to provide some new ideas for diagnosis and treatment of gastric cancer. MethodBy reviewing and screening relevant domestic and foreign literatures, the latest researches on the relation between blood glucose regulating hormones and gastric cancer were summarized. ResultsThe insulin, glucagon, adrenaline, growth hormone, and the other blood glucose regulating hormones all played the roles in promoting the occurrence and development of gastric cancer. However, glucocorticoids and somatostatin were protective hormones that maintained gastric homeostasis and inhibited the proliferation of gastric cancer cells. ConclusionBlood glucose regulating hormones play some roles in diagnosis and treatment of gastric cancer, but specific mechanisms such as interaction between blood glucose regulating hormones, role of glucose metabolism in biological behavior of gastric cancer, and effect of blood glucose regulating hormones on oncogene initiation are unclear, so prospective clinical control studies still need to be studied.

    Release date:2022-07-26 10:20 Export PDF Favorites Scan
  • Research progress on minimally invasive and non-invasive blood glucose detection methods

    Blood glucose monitoring has become the weakest point in the overall management of diabetes in China. Long-term monitoring of blood glucose levels in diabetic patients has become an important means of controlling the development of diabetes and its complications, so that technological innovations in blood glucose testing methods have far-reaching implications for accurate blood glucose testing. This article discusses the basic principles of minimally invasive and non-invasive blood glucose testing assays, including urine glucose assays, tear assays, methods of extravasation of tissue fluid, and optical detection methods, etc., focuses on the advantages of minimally invasive and non-invasive blood glucose testing methods and the latest relevant results, and summarizes the current problems of various testing methods and prospects for future development trends.

    Release date:2023-06-25 02:49 Export PDF Favorites Scan
  • Realization of non-invasive blood glucose detector based on nonlinear auto regressive model and dual-wavelength

    The use of non-invasive blood glucose detection techniques can help diabetic patients to alleviate the pain of intrusive detection, reduce the cost of detection, and achieve real-time monitoring and effective control of blood glucose. Given the existing limitations of the minimally invasive or invasive blood glucose detection methods, such as low detection accuracy, high cost and complex operation, and the laser source's wavelength and cost, this paper, based on the non-invasive blood glucose detector developed by the research group, designs a non-invasive blood glucose detection method. It is founded on dual-wavelength near-infrared light diffuse reflection by using the 1 550 nm near-infrared light as measuring light to collect blood glucose information and the 1 310 nm near-infrared light as reference light to remove the effects of water molecules in the blood. Fourteen volunteers were recruited for in vivo experiments using the instrument to verify the effectiveness of the method. The results indicated that 90.27% of the measured values of non-invasive blood glucose were distributed in the region A of Clarke error grid and 9.73% in the region B of Clarke error grid, all meeting clinical requirements. It is also confirmed that the proposed non-invasive blood glucose detection method realizes relatively ideal measurement accuracy and stability.

    Release date:2021-06-18 04:50 Export PDF Favorites Scan
  • Current Situation and Influencing Factors of Self-Monitoring of Blood Glucose in Type 2 Diabetic Patients in Sichuan Province

    Objective To investigate the current situation of self-monitoring of blood glucose (SMBG) in patients with type 2 diabetes mellitus (T2DM) in Sichuan province, and to analyze the influencing factors of SMBG, so as to provide evidence for improving the level of SMBG. Methods By the convenience sampling method, 410 patients with T2DM for more than 1 year were selected from 17 hospitals and community health service centers in 7 cities across Sichuan province, and their SMBG was investigated with a questionnaire. Results Among 410 eligible patients, the average frequency of SMBG was 7.3 times per month. There were 268 patients (65.4%) performed SMBG less than 4 times per month, 94 (22.9%) performed 4-15 times per month, 29 (7.1%) performed 6-29 times per month, and 19 (4.6%) performed over 30 times per month. Just 234 patients (57.1%) monitored the HbA1c in the past 6 months. FPG, 2-hour PPG and HbA1c were negatively correlated with the frequency of SMBG. The influencing factors of SMBG were insulin treatment and education. Conlusion The SMBG status in D2TM patients is relatively poor in Sichuan province, and the compliance of SMBG is expected to be improved by enhancing diabetic education.

    Release date: Export PDF Favorites Scan
  • The Changes and Measures Against the Glucose in the Operation of the Diabetes by TURP

    摘要:目的:探讨经尿道前列腺电切术中糖尿病患者血糖变化以及处理对策。方法:2006年7月~ 2009年1月共对80例患有前列腺增生合并糖尿病患者行TURP,同期对80例单纯性前列腺增生患者进行相同手术,回顾分析其术前、术中30 min、60 min、90 min 指尖血糖变化及干预情况。结果:治疗组80例患者,51例术中血糖值明显低于术前,分别为1.8~3 mmol/L;对照组术前与术中血糖值基本一致,血糖波动于4.5~5.6 mmol/L。结论:糖尿病患者糖的储备能力差,在行经尿道电切术中易发生低血糖综合征,术中及时的血糖监测及干预对保证患者的安全有重要意义。Abstract: Objective: To study the changes and measures against the glucose in the operation of the Diabetes by TURP. Methods:Eighty patients with prostate combining diabetes operated from July 2006 to Jan. 2009 were reviewed, and 80 prostate treated at the same period with the same operation measure were selected as control. The preoperative glucose, intraoperative glucose (30′, 60′,90′) of fingertip, and countermeasures were studied and compared between the two groups. Results:Fiftyone cases of the experimental group of intraoperative blood glucose was significantly lower than preoperative values, respectively 1.83 mmol/ L; control group preoperative and intraoperative blood glucose values were basically the same, blood glucose fluctuations in the 4.55.6 mmol/L. Conclusion: The capacity in patients with diabetes is poor, easy to hypoglycemia syndrome in the act of TURP surgery, intraoperative blood glucose monitoring and timely intervention to ensure patient safety significance.

    Release date:2016-09-08 10:12 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content