west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "decellularized matrix" 2 results
  • Construction of a novel tissue engineered meniscus scaffold based on low temperature deposition three-dimenisonal printing technology

    Objective To investigate the construction of a novel tissue engineered meniscus scaffold based on low temperature deposition three-dimenisonal (3D) printing technology and evaluate its biocompatibility. Methods The fresh pig meniscus was decellularized by improved physicochemical method to obtain decellularized meniscus matrix homogenate. Gross observation, HE staining, and DAPI staining were used to observe the decellularization effect. Toluidine blue staining, safranin O staining, and sirius red staining were used to evaluate the retention of mucopolysaccharide and collagen. Then, the decellularized meniscus matrix bioink was prepared, and the new tissue engineered meniscus scaffold was prepared by low temperature deposition 3D printing technology. Scanning electron microscopy was used to observe the microstructure. After co-culture with adipose-derived stem cells, the cell compatibility of the scaffolds was observed by cell counting kit 8 (CCK-8), and the cell activity and morphology were observed by dead/live cell staining and cytoskeleton staining. The inflammatory cell infiltration and degradation of the scaffolds were evaluated by subcutaneous experiment in rats. Results The decellularized meniscus matrix homogenate appeared as a transparent gel. DAPI and histological staining showed that the immunogenic nucleic acids were effectively removed and the active components of mucopolysaccharide and collagen were remained. The new tissue engineered meniscus scaffolds was constructed by low temperature deposition 3D printing technology and it had macroporous-microporous microstructures under scanning electron microscopy. CCK-8 test showed that the scaffolds had good cell compatibility. Dead/live cell staining showed that the scaffold could effectively maintain cell viability (>90%). Cytoskeleton staining showed that the scaffolds were benefit for cell adhesion and spreading. After 1 week of subcutaneous implantation of the scaffolds in rats, there was a mild inflammatory response, but no significant inflammatory response was observed after 3 weeks, and the scaffolds gradually degraded. Conclusion The novel tissue engineered meniscus scaffold constructed by low temperature deposition 3D printing technology has a graded macroporous-microporous microstructure and good cytocompatibility, which is conducive to cell adhesion and growth, laying the foundation for the in vivo research of tissue engineered meniscus scaffolds in the next step.

    Release date:2024-06-14 09:52 Export PDF Favorites Scan
  • Preliminary study on preparation of decellularized nerve grafts from GGTA1 gene-edited pigs and their immune rejection in xenotransplantation

    Objective To prepare decellularized nerve grafts from alpha-1, 3-galactosyltransferase (GGTA1) gene-edited pigs and explore their biocompatibility for xenotransplantation. Methods The sciatic nerves from wild-type pigs and GGTA1 gene-edited pigs were obtained and underwent decellularization. The alpha-galactosidase (α-gal) content in the sciatic nerves of GGTA1 gene-edited pigs was detected by using IB4 fluorescence staining and ELISA method to verify the knockout status of the GGTA1 gene, and using human sciatic nerve as a control. HE staining and scanning electron microscopy observation were used to observe the structure of the nerve samples. Immunofluorescence staining and DNA content determination were used to evaluate the degree of decellularization of the nerve samples. Fourteen nude mice were taken, and subcutaneous capsules were prepared on both sides of the spine. Decellularized nerve samples of wild-type pigs (n=7) and GGTA1 gene-edited pigs (n=7) were randomly implanted in the subcutaneous capsules. Blood was drawn at 1, 3, 5, and 7 days after implantation to detect neutrophil counting. Results IB4 fluorescence staining and ELISA detection showed that GGTA1 gene was successfully knocked out in the nerves of GGTA1 gene-edited pigs. HE staining showed that the structure of the decellularized nerve from GGTA1 gene-edited pigs was well preserved; the nerve basement membrane tube structure was visible under scanning electron microscopy; no cell nuclei was observed, and the extracellular matrix components was retained in the nerve grafts by immunofluorescence staining; and the DNA content was significantly reduced when compared with the normal nerves (P<0.05). In vivo experiments showed that the number of neutrophils in the two groups were similar at 1, 3, and 7 days after implantation, with no significant difference (P>0.05); only at 5 days, the number of neutrophils was significantly lower in the GGTA1 gene-edited pigs than in the wild-type pigs (P<0.05). Conclusion The decellularized nerve grafts from GGTA1 gene-edited pigs have well-preserved nerve structure, complete decellularization, retain the natural nerve basement membrane tube structure and components, and low immune response after xenotransplantation through in vitro experiments.

    Release date:2025-02-17 08:55 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content