west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "disinfection" 14 results
  • Innovative practice of auditing qualification documents of disinfectant, disinfection devices and disposable medical devices

    The quality of disinfectant, disinfection devices and disposable medical devices is closely related to the patients' safety. Hospital infection management department must carry out the audit responsibilities for qualification documents of disinfectant, disinfection devices and disposable medical devices, to guarantee legality, safety and effectiveness of products used in hospital. This paper mainly introduces the implementation of qualification documents audit in West China Hospital, Sichuan University, including system construction, process reengineering, documents audit scope and key points, and document management.

    Release date:2018-03-26 03:32 Export PDF Favorites Scan
  • Analysis of high-level disinfection effect of flexible endoscopes in an endoscope center

    ObjectiveTo evaluate the high-level disinfection effect of flexible endoscopes in the Endoscopy Center of the First People’s Hospital of Longquanyi District of Chengdu, explore the key links of flexible endoscope cleaning and disinfection, and provide theoretical guarantee and technical support for the next step of the endoscope center work.MethodsWe sampled and monitored the lumens, water and air injection ports and biopsy ports of 19 flexible endoscopes after high-level disinfection in the Endoscopy Center of the First People’s Hospital of Longquanyi District of Chengdu. A total of 307 specimens were collected from 108 flexible endoscopes. We compared the disinfection effects of different flexible endoscopes and different sampling sites, and compared the microbial detection status of different flexible endoscopes.ResultsThe qualified rates of disinfection of gastroscopes, colonoscope and duodenoscopy were 79.22%, 86.21% and 100.00%, respectively, and the difference was not statistically significant (P=0.721). The qualified rates of disinfection of the endoscopic lumen, water and air injection port and biopsy port were 87.04%, 93.00% and 94.95%, respectively, and the difference was not statistically significant (χ2=4.585, P=0.101). The qualified rates of the lumen, water and air injection port and biopsy port of gastroscope, colonoscope and duodenoscope were 84.42%, 93.10%, 100.00%, 92.96%, 92.59%, 100.00%, 94.29%, 96.30%, 100.00%, respectively. There was no statistically significant difference in the disinfection effect of various parts of different flexible endoscopes (P>0.05). Bacteriological identification showed that of the 28 specimens with excess bacteriological standards, 16 gram-positive bacteria (57.1%), and 12 gram-negative bacteria (42.9%) were found.ConclusionThe cleaning and disinfection effect of flexible endoscopes has certain defect. Endoscope should be treated in strict accordance with the technical specifications for cleaning and disinfection of the flexible endoscope to further improve the disinfection effect of the flexible endoscope.

    Release date:2021-04-15 05:32 Export PDF Favorites Scan
  • Efficiency of hydrogen peroxide vapors in reducing multidrug-resistant organisms: a meta-analysis

    ObjectiveTo evaluate the efficiency of hydrogen peroxide vapor (HPV) in disinfecting multidrug-resistant organisms (MDROs).MethodsWe searched Cochrane Library, PubMed, Embase, Web of Science, China National Knowledge Infrastructure, Wanfang, China Science and Technology Journal Database for before-after studies or case-control studies or cohort studies evaluating efficiency of HPV and published from January 2010 to December 2020 (the time range was from January 2000 to December 2020 in the snowball searching). RevMan 5.4 and R 4.0.2 softwares were used for meta-analysis.ResultsA total of 9 studies were included, consisting of 8 before-after studies and 1 cohort study. Six studies evaluated positive rate of environmental samplings, meta-analysis revealed that HPV combined with manual cleaning disinfected the environment efficiently [relative risk (RR)=0.03, 95% confidence interval (CI) (0.01, 0.08), P< 0.000 01] and HPV was more efficient than manual cleaning [RR=0.04, 95%CI (0.02, 0.10), P< 0.000 01]. Three studies evaluated the hospital-acquired MDROs colonization/infection rates, and the results of the 3 studies were consistent, revealing that HPV could reduce hospital-acquired MDROs colonization/infection rates.ConclusionHPV is efficient in reducing MDROs contaminated surfaces and hospital-acquired infection rate.

    Release date:2021-04-15 05:32 Export PDF Favorites Scan
  • Mechanism of cold atmospheric plasma in treatment of chronic skin ulcer

    Objective To review the mechanism of cold atmospheric plasma (CAP) in the treatment of chronic skin ulcer, providing a new idea for ulcer therapy. Methods The literature about CAP in the treatment of chronic skin ulcers in recent years was extensively screened and reviewed. The treatment principle, active ingredients, and mechanism were summarized. Results CAP is partial ionized gas discharged by plasma generator in high frequency under high voltage. It contains electrons, positive and negative ions, reactive oxygen species, reactive nitrogen species, and ultraviolet rays. In vitro and animal experiments show that the active ingredients contained in CAP can inactive microorganisms, against biofilm, regulate immune-mediated inflammatory, promoting blood flow, stimulate tissue regeneration and epithelial formation in the course of wounds healing. Conclusion CAP play a role in different stages of chronic skin ulcer healing, with good effectiveness and safety, and broad clinical application prospects. But more studies are needed to explore the indications and dosages of CAP therapy.

    Release date:2024-11-13 03:16 Export PDF Favorites Scan
  • Investigation and Analysis on the Standardization of Surgical Hand-washing and Hand-disinfection

    ObjectiveTo investigate on preoperative hand-washing for analyzing the underlying problems, in purpose of preventing operation-related infection via strengthening the standardization of surgical hand-washing and hand-disinfection. MethodsFrom July to September 2014, surveillance video of pre-operative hand-washing was studied and analyzed. We randomly selected 100 subjects, and assessment was performed based on the self-made surgical hand-washing and hand-disinfection protocol. Grading was done strictly. The passing score was 60 or higher; a score of 70-79 meant good; and a score of 80-100 indicated excellence. ResultsIn the survey, 91 in the 100 subjects were qualified. Among the qualified subjects, there were 53% of excellence and 20% of good. The major problems included erroneous methods, step omissions, time lacking, pollution, wrong flushing method or dry-hand method, and insufficient washing time. ConclusionBased on the survey, the administration department is advised to strengthen the regulatory supervision and education training based on standard surgical hand-washing and hand-disinfection criteria, especially training interns and new staff, in purpose of reducing the incidence of operation-related infection and improving hospitalization management qualities.

    Release date: Export PDF Favorites Scan
  • Experimental study on silicone hand disinfection by a touchable non-thermal plasma

    In this study, silicone hand was disinfected by homemade touchable non-thermal plasma to simulate and evaluate its feasibility of application on human hand. Experimental results showed that there was no significant difference whenEscherichia coli (E. coli),Staphylococcus aureus (S. au),Staphylococcus albus (S. al), andPseudomonas aeruginosa (P. ae) were loaded on the silicone hand surface and treated with plasma. The efficiency of plasma disinfection was higher when the treatment time was prolonged or initial bacterial density was lower. When initial bacterial number was 1.0×106–1.0×107 CFU, the plasma disinfection process mainly occured in the first 5 s and more than 99% of bacteria could be disinfected. This study can provide guidelines for the development of a new plasma device for human hand disinfection.

    Release date:2017-04-13 10:03 Export PDF Favorites Scan
  • Comparative study among three methods on surface disinfection in Intensive Care Unit

    Objective To compare germicidal effect of three disinfectants acting on frequently-touched surfaces in Intensive Care Unit (ICU) at different time points after disinfection so as to put forward the reasonable disinfection method and interval before the next disinfection. Methods We wiped the four frequently-touched surfaces in ICU with disinfectant containing acidic electrolyzed oxidizing water (EOW) from the building system of hospital, disinfectant wipes, and 500 mg/L chlorine respectively. The culture samples were collected from the surfaces before wiping, and 10 minutes, 30 minutes, 1 hour, 2 hours and 4 hours after wiping respectively. The bacterial clearance rate and the qualified rate of bacterial colony counts on the surfaces were compared among the three different disinfectants at different time points after disinfection. Results The bacterial killing rate of three methods for disinfection of object surfaces decreased with the passing of time. The bacterial killing rate of EOW from the building system of hospital was lower than that of the other two methods at all five time points after disinfection (P< 0.05). The bacterial killing rate at hour four after disinfection using chlorine-containing disinfectant and disinfectant wipes was higher than 90.0%. The qualified rate of bacterial colony counts on the surfaces at 10 and 30 minutes after disinfection among the three groups was not significantly different (P>0.05). The qualified rate of bacterial colony counts on the surfaces disinfected by EOW from the building system of hospital was lower than that in the other two groups at the other three time points (P<0.05), and it was totally unqualified at hour four after disinfection. Conclusions The germicidal effect of EOW from the building system of hospital is inferior to chlorine disinfectant and disinfectant wipes. Moreover, the surface can be easily recontaminated after disinfection. It is suggested that EOW should be used in ICU every other hour. and the other two disinfection methods should be used every two hours.

    Release date:2017-03-27 11:42 Export PDF Favorites Scan
  • Investigation and Analysis on Prophlactical Disinfection in Deyang Disaster Areas after Wenchuan Earthquake

    Objective To provide the evidence for anti-epidemic command and developing response plan through investigation on prophlactical disinfection in Deyang, the worst-hit areas after Wenchuan earthquake. Methods We used convenient sampling together with the report forms and the self-made questionnaire to collect information from 107 villages and 17 settlement spots for the disaster victims in 25 towns in Deyang disaster area. Results There were a total of 6 kinds of disinfectant, including the chlorine disinfectant, 2 kinds of peroxide disinfectant and 2 other types of disinfectant, which were delivered the Deyang disaster area through the National amp; Province CDC system allocation or the None-Goverment Organization donation. From May 17 to June 9, the large-scale preventive disinfection was carried out in the disaster area, covering tap water, the restroom and the latrine pit, trash, environment and sewage. All personnel who conducted the disinfection for prevention and public health in the villages and towns received the technical training for disinfection. Conclusion Various disinfectant types and difference specifications cause trouble in the training of manpower and the use of disinfectant. Preventive disinfection in the most serious disaster areas is better than in serious disaster areas. The main channel of obtaining the disinfectant is through the National amp; Province CDC. The daily-report system of the disinfected areas may monitor the progress of disinfectant use. The suitable disinfection may prevent the public health secondary disaster and protect the environment effectively.

    Release date:2016-09-07 02:13 Export PDF Favorites Scan
  • Advances, advantages, and limitations of different disinfection technologies

    This article reviews the current status and characteristics of disinfection technologies in the modern era, including physical, chemical, and integrated disinfection methods. It focuses on the latest research advances, advantages, and limitations of novel disinfection technologies, such as plasma-activated systems, photocatalytic oxidation, and synergistic chemical-physical or bio-chemical composite techniques. The study reveals that single disinfection methods often fail to meet the demands of complex environments, while integrated technologies demonstrate significant advantages in improving disinfection efficiency and environmental compatibility. However, challenges remain in terms of cost, standardization, and long-term safety. Future development of disinfection technologies should prioritize intelligent multi-technology integration, green and sustainable practices, targeted disinfection, personalized applications, and international standardization.

    Release date:2025-03-31 02:13 Export PDF Favorites Scan
  • Evaluation of practical experience with medical sewage treatment in medical institutions in China

    ObjectiveTo evaluate the evidence of the experience with medical sewage treatment procedures in medical institutions in China. MethodsDatabases including CNKI, WanFang Data, PubMed, Web of Science, and EBSCO were electronically searched to collect studies on the medical sewage treatment process, flow, and specifications in medical institutions in China. We used the quality evaluation system to classify and grade the experiences based on the principles and methods of evidence-based science and performed a descriptive analysis. ResultsAfter the SARS pandemic in 2003, China systematically established and standardized the technical criteria of medical sewage treatment and discharge. Moreover, a prevention system for the epidemic using medical sewage was constructed, which guaranteed that the quality of medical sewage treatment and discharge would meet the criteria and protect the citizens, and the technical specifications of medical sewage treatment would progress and increase strictly. At present, medical sewage treatment in medical institutions in China was based on mechanical and biological methods, and disinfection was mainly performed using chlorine and its compounds, ozone, and ultraviolet light. ConclusionThe COVID-19 pandemic requires a higher quality of medical sewage treatment and discharge criteria for medical institutions in China. To meet these criteria, all medical institutions in China should check, replace, and update their old facilities; strengthen personnel training and effectively ensure the quality of medical sewage treatment.

    Release date:2022-09-20 10:03 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content