west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "edge-to-edge" 21 results
  • Transcatheter edge-to-edge repair: Operating theories, basic principles, and predictors of prognosis

    Mitral regurgitation is one of the most common heart valve diseases. Transcatheter edge-to-edge repair (TEER) is currently the most developed and commonly used interventional technique for mitral regurgitation and is recommended by the latest European and American guidelines for patients who are at high surgical risk. TEER device usually consists of a clamping device and a delivery system. The trajectory of the clamping device is called the trajectory, and the trajectory can be well established with the five dimensions movement of the delivery system: left-right oscillation, anterior-posterior oscillation, overall parallel movement, the clamping device's own clockwise rotation, and vertical up-and-down movement. The delivery system's anteroposterior and lateral oscillations are concentrated on the virtual puncture site. Furthermore, the location of the septal puncture site has a significant impact on the establishemnt of the trajectory. The evulation of three variables and adherence to the "4M principles" are necessary for the successful TEER. The three variables are: the position of the clip in the center of the regurgitation,the arm orientation of the clip perpendicular to the boundary of anterior and posterior leaflets, as well as the appropriate length of clamping. The "4M principles" include favorable valve morphology, residual mitral regurgitation below grade 2+, mean transvalvular pressure≤5 mm Hg, and an appropriate amount of leaflets clamping. Patients' baseline situation, the degree of mitral regurgitation and ventricular remodeling, as well as the valve morphology and the outcome of the procedure, are the factors determining the prognosis of patients after TEER.

    Release date:2022-08-25 08:52 Export PDF Favorites Scan
  • Early efficacy of "one-stop" transapical transcatheter aortic valve replacement combined with mitral valve edge-to-edge repair in the treatment of multivalvular disease

    Objective To investigate the feasibility and early efficacy of transapical transcatheter aortic valve replacement (TAVR) combined with transcatheter mitral valve edge-to-edge repair (TEER) in patients with high-risk aortic valve lesions combined with severe mitral regurgitation. Methods The clinical data of patients who underwent "one-stop" transapical TAVR+TEER in our hospital from August 2022 to October 2023 were retrospectively analyzed. Results Five patients were collected, including 3 males and 2 females with a mean age of 66.6±1.8 years. Four patients had aortic valve insufficiency combined with mitral regurgitation and one had aortic valve stenosis and insufficiency combined with mitral regurgitation. All patients successfully completed transapical TAVR+TEER, and the immediate postoperative echocardiographic results revealed that none of them had more than mild perivalvular leakage and mitral regurgitation, and the prosthetic valves were in good position and function. At 1 week postoperatively, echocardiographic results showed 5 patients with no displacement of the prosthetic valve, detachment of the mitral clip, or damage to the leaflets. At 1 month postoperatively, cardiac function was improved to varying degrees in 4 patients, and 1 patient died of multiorgan failure. At 2 months postoperatively, 1 patient died of cerebrovascular accident, and at 3 months postoperatively the echocardiographic results of the remaining 3 patients revealed that there was no more than mild perivalvular leakage or mitral regurgitation, and the patients' postoperative cardiac function and daily life ability were significantly improved. Conclusion In high-risk aortic valve lesions combined with severe mitral regurgitation, "one-stop" transapical TAVR+TEER is feasible with favorable early efficacy and safety.

    Release date:2024-09-20 01:01 Export PDF Favorites Scan
  • Mitral transcatheter edge-to-edge repair: A state of art and strategic principles

    Transcatheter edge-to-edge repair (TEER) for mitral regurgitation (MR) is known as M-TEER. Its strengths include: precise targets and fewer implants; simple and clear principles for catheterization; originating from dependable medical concepts and broad applicability. Furthermore, TEER offers advantages in real-time hemodynamic and effectiveness measurement throughout the procedure over surgical edge-to-edge repair (SEER). When it comes to patients with degenerative mitral regurgitation , M-TEER should aim to deliver more optimum procedural outcomes. In functional mitral regurgitation, a modest transvalvular gradients or moderate residual shunt can be tolerated with M-TEER, which reduces the risk of problems and has no bearing on the patient's prognosis.

    Release date:2024-02-20 03:09 Export PDF Favorites Scan
  • Multivue reconstruction technique during mitral valve transcatheter edge-to-edge repair: A case report

    Echocardiography is an important imaging technique in mithal valve transcatheter edge-to-edge repair (TEER). During the operation, mitral leaflets capture and clamping have the highest requirements for ultrasound image quality and should be performed under the guidance of high-quality commissural view. However, standard commissural view cannot be obtained in some patients due to cardiac enlargement, transposition or limited esophageal acoustic window. In this condition, the optimal view can be obtained by Multivue technology. This paper reports a male patient aged 67 years with successful mitral valve TEER under the real-time guidance of Multivue technology, and summarizes the key points of this technology.

    Release date:2025-09-22 05:53 Export PDF Favorites Scan
  • Short-term effectiveness of edge-to-edge #-shaped suture for complete radial tear of lateral meniscus body

    Objective To investigate the surgical method and short-term effectiveness of arthroscopy edge-to-edge #-shaped suture in the treatment of the complete radial tear of the lateral meniscus body. Methods The clinical data of 13 patients with complete radial tear of lateral meniscus body between May 2020 and August 2023 were retrospectively analyzed. There were 10 males and 3 females, aged 15-38 years (mean, 24.2 years). There were 11 cases of acute injury and 2 cases of chronic injury, with time from injury to admission ranging from 2 days to 5 months. All patients had tenderness in the lateral joint space, and 2 patients with chronic injury had positive McMurray’s sign. All patients were treated with arthroscopic edge-to-edge #-shaped suture technique. The knee joint activity and tenderness in the lateral joint space were detected, and the healing of the incision and the occurrence of complications were observed. X-ray films and MRI of the knee joint were performed to evaluate joint degeneration and meniscus healing. Lysholm score, International Knee Documentation Committee (IKDC) subjective score, Tegner score, and visual analogue scale (VAS) score were used to evaluate the functional recovery before and after operation. Results The operation time ranged from 46 to 100 minutes (mean, 80.08 minutes). All the incisions healed by first intention, and no complication such as intraoperative vascular and nerve injury or postoperative infection occurred. All 13 patients were followed up 20-59 months (mean, 29.3 months). All patients had no limitation of knee extension and flexion. One patient with chronic injury continued to have tenderness in the lateral space of the knee joint, while the remaining patients had no tenderness, swelling, and locking in the lateral space. Immediate postoperative MRI of knee joint showed continuous recovery of the lateral meniscus. At last follow-up, no degenerative changes were observed in X-ray films of knee joint. Except for 1 patient with chronic injury, the MRI of the other patients showed the healing performance after lateral meniscus suture. Lysholm score, IKDC subjective score, Tegner score, and VAS score all significantly improved when compared with those before operation (P<0.05). Conclusion The edge-to-edge #-shaped suture technique can effectively repair the complete radial tear of the lateral meniscus body, and the short-term effectiveness is satisfactory.

    Release date:2025-09-01 10:12 Export PDF Favorites Scan
  • Transcatheter edge-to-edge repair (TEER): Past, current and future perspectives

    Transcatheter edge-to-edge repair (TEER) originated from surgical edge-to-edge repair. MitraClip is the first mature TEER device, and the TEER based on MitraClip is far ahead of many transcatheter mitral valve repair (TMVr) technologies in terms of safety, effectiveness and popularity, so it is named separately in the latest guidelines. The TEER has the following advantages: consistent with basic medical principles, few implants, precise target, less invasive and repeatable. However, there are also some shortcomings, such as the relatively complex design of transfemoral device, target single and relatively narrow indications. At present, the main clinical data of TEER are mainly from the clinical practice of MitraClip. Based on the three-year outcomes of COAPT study, both 2020 ACC/AHA guideline and 2020 ACC expert consensus decision pathway on the management of mitral regurgitation recommend in patients with chronic heart failure with left ventricular dysfunction and severe mitral regurgitation in nonresponders to medicine treatment. Edward's PASCAL, another TEER device, has two models. Among the domestic TEER devices, the ValveClamp of Hanyu medical technology has many distinct advantages, such as simple operation, large clamping area, high clamping efficiency and no need of X-ray. DragonFly, another domestic TEER device, has also completed its feasibility study. There are five trends of TEER in the future: further expansion of indications, combination with other interventional techniques, repeatable operations, transcatheter mitral valve replacement after TEER, and continuous improvement and innovation of equipment.

    Release date:2021-12-27 11:31 Export PDF Favorites Scan
  • Progress in the application of transcatheter mitral valve edge-to-edge repair in mitral regurgitation

    Over the past 20 years, transcatheter mitral valve edge-to-edge repair (TEER) has become an important treatment option for patients with severe mitral regurgitation (MR) who are at high surgical risk. Initially, several landmark clinical studies established the basis of TEER for primary and secondary MR, but they only involved clinically stable patients with appropriate mitral valve anatomy. With the increasing experience of interventional therapy, the iteration of equipment and the improvement of intraoperative imaging technology, the scope of use of TEER has been continuously expanded, and its indications have been continuously expanded to more complex mitral valve lesions and clinical situations. Therefore, in clinical practice, selecting the appropriate device according to the individual anatomical characteristics of the patient can minimize MR and complications, thereby optimizing immediate and long-term prognosis. This article mainly introduces the pathogenesis and related mechanisms of MR, the main TEER devices and their clinical evidence, the limitations of TEER, and the future development direction.

    Release date:2023-09-28 02:17 Export PDF Favorites Scan
  • Clinical pathway for transcatheter mitral valve edge-to-edge repair in China (abbreviated version 2022)

    Transcatheter mitral valve edge-to-edge repair (TEER) has become an important treatment opinion for patients with severe mitral regurgitation (MR) at high risk for surgery. The devices and procedural techniques of TEER are complex and require excellent team cooperation. However, there is still a lack of standardized clinical pathways in China. Based on the latest evidence, the expert group wrote this clinical pathway to guide and optimize TEER therapy in clinical practice. It demonstrates the following key issues of clinical concern: (1) TEER team building; (2) preoperative clinical evaluation of TEER patients; (3) imaging assessment before TEER procedure; (4) standardized procedures for TEER; (5) TEER for complex MR; (6) the standard process of perioperative comprehensive management; and (7) full life-cycle rehabilitation and follow-up. This clinical pathway might be helpful to facilitate the standardized development of TEER therapy and application, and promote the improvement of management and life quality for patients with MR.

    Release date:2023-03-01 04:15 Export PDF Favorites Scan
  • Peri-interventional echo assessment for transcatheter edge-to-edge repair

    Transcatheter edge-to-edge repair (TEER) is at present a well established interventional procedure for the treatment of mitral regurgitation (MR). Echocardiography is an essential imaging modality for peri-interventional assessment of TEER. Pre-procedural echocardiographic assessments, which include grading of MR severity, determining MR etiology and mechanisms, and analyzing mitral valve morphology, helps to determine patient eligibility and plan the procedure. Echocardiography is also indispensable in intra-procedural guidance, such as atrial septum puncture, advancing the device to the target position, and leaflets capture. In addition, echocardiography is important in immediate result evaluation, complication detection and patient follow up after the procedure.

    Release date:2022-10-19 05:32 Export PDF Favorites Scan
  • MitraClip device for patients with severe mitral valve regurgitation: a rapid health technology assessment

    ObjectiveTo utilize a rapid health technology assessment to evaluate the efficacy, safety and cost-effectiveness of the MitraClip device for patients with severe mitral regurgitation (MR). MethodsPubMed, EMbase, The Cochrane Library, CNKI, WanFang Data, CBM and the CRD databases were electronically searched to collect clinical evidence and economic evaluations on the efficacy, safety and cost-effectiveness of the MitraClip device for patients with severe MR from inception to May 2022. Two reviewers independently screened literature, extracted data and assessed the risk of bias of included studies; then, descriptive analyses and data summaries were performed. ResultsA total of 33 studies, involving 4 HTA reports, 3 RCTs, 16 systematic reviews or meta-analyses, and 10 economic evaluations were included. In the evidence comparing MitraClip and surgery, most of the literature showed that the MitraClip group had higher postoperative residual MR, fewer blood transfusion events, and fewer hospital days. We found no significant treatment effects on 30-day adverse events and mortality, and the 1-year and above survival rate. In the evidence of MitraClip versus medical therapy alone, all included studies showed that MitraClip benefited mid-term and long-term survival and reduced the incidence of subsequent cardiac hospitalizations. Economic evaluations showed that the clinical benefits were cost-effective in the setting of their health service systems. ConclusionThe available high-grade clinical evidence shows that MitraClip is effective and safe to some extent, and has cost-effectiveness compared with traditional treatment in other countries. However, the real-world effectiveness and cost-effectiveness of the MitraClip need to be tested in the Chinese population and health-care setting.

    Release date:2023-02-16 04:29 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content