west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "finite element" 83 results
  • Finite element method simulating bursting process of multi-chamber flexible package infusion bag

    This study aims to overcome the shortcomings such as low efficiency, high cost and difficult to carry out multi-parameter research, which limited the optimization of infusion bag configuration and manufacture technique by experiment method. We put forward a fluid cavity based finite element method, and it could be used to simulate the stress distribution and deformation process of infusion bag under external load. In this paper, numerical models of infusion bag with different sizes was built, and the fluid-solid coupling deformation process was calculated using the fluid cavity method in software ABAQUS subject to the same boundary conditions with the burst test. The peeling strength which was obtained from the peeling adhesion test was used as failure criterion. The calculated resultant force which makes the computed peeling stress reach the peeling strength was compared with experiment data, and the stress distribution was analyzed compared with the rupture process of burst test. The results showed that considering the errors caused by the difference of weak welding and eccentric load, the flow cavity based finite element method can accurately model the stress distribution and deformation process of infusion bag. It could be useful for the optimization of multi chamber infusion bag configuration and manufacture technique, leading to cost reduction and study efficiency improvement.

    Release date:2021-08-16 04:59 Export PDF Favorites Scan
  • Effects of different alveolar bone finite element models on the biomechanical responses of periodontal ligament

    In the study of oral orthodontics, the dental tissue models play an important role in finite element analysis results. Currently, the commonly used alveolar bone models mainly have two kinds: the uniform and the non-uniform models. The material of the uniform model was defined with the whole alveolar bone, and each mesh element has a uniform mechanical property. While the material of the elements in non-uniform model was differently determined by the Hounsfield unit (HU) value of computed tomography (CT) images where the element was located. To investigate the effects of different alveolar bone models on the biomechanical responses of periodontal ligament (PDL), a clinical patient was chosen as the research object, his mandibular canine, PDL and two kinds of alveolar bone models were constructed, and intrusive force of 1 N and moment of 2 Nmm were exerted on the canine along its root direction, respectively, which were used to analyze the hydrostatic stress and the maximal logarithmic principal strain of PDL under different loads. Research results indicated that the mechanical responses of PDL had been affected by alveolar bone models, no matter the canine translation or rotation. Compared to the uniform model, if the alveolar bone was defined as the non-uniform model, the maximal stress and strain of PDL were decreased by 13.13% and 35.57%, respectively, when the canine translation along its root direction; while the maximal stress and strain of PDL were decreased by 19.55% and 35.64%, respectively, when the canine rotation along its root direction. The uniform alveolar bone model will induce orthodontists to choose a smaller orthodontic force. The non-uniform alveolar bone model can better reflect the differences of bone characteristics in the real alveolar bone, and more conducive to obtain accurate analysis results.

    Release date:2021-06-18 04:50 Export PDF Favorites Scan
  • Simulation method of skull remodellingsurgeryfor infant with craniosynostosis

    Craniofacial malformation caused by premature fusion of cranial suture of infants has a serious impact on their growth. The purpose of skull remodeling surgery for infants with craniosynostosis is to expand the skull and allow the brain to grow properly. There are no standardized treatments for skull remodeling surgery at the present, and the postoperative effect can be hardly assessed reasonably. Children with sagittal craniosynostosis were selected as the research objects. By analyzing the morphological characteristics of the patients, the point cloud registration of the skull distortion region with the ideal skull model was performed, and a plan of skull cutting and remodeling surgery was generated. A finite element model of the infant skull was used to predict the growth trend after remodeling surgery. Finally, an experimental study of surgery simulation was carried out with a child with a typical sagittal craniosynostosis. The evaluation results showed that the repositioning and stitching of bone plates effectively improved the morphology of the abnormal parts of the skull and had a normal growth trend. The child’s preoperative cephalic index was 65.31%, and became 71.50% after 9 months’ growth simulation. The simulation of the skull remodeling provides a reference for surgical plan design. The skull remodeling approach significantly improves postoperative effect, and it could be extended to the generation of cutting and remodeling plans and postoperative evaluations for treatment on other types of craniosynostosis.

    Release date:2021-12-24 04:01 Export PDF Favorites Scan
  • Three-dimensional finite element model construction and biomechanical analysis of customized titanium alloy lunate prosthesis

    Objective To design customized titanium alloy lunate prosthesis, construct three-dimensional finite element model of wrist joint before and after replacement by finite element analysis, and observe the biomechanical changes of wrist joint after replacement, providing biomechanical basis for clinical application of prosthesis. Methods One fresh frozen human forearm was collected, and the maximum range of motions in flexion, extension, ulnar deviation, and radialis deviation tested by cortex motion capture system were 48.42°, 38.04°, 35.68°, and 26.41°, respectively. The wrist joint data was obtained by CT scan and imported into Mimics21.0 software and Magics21.0 software to construct a wrist joint three-dimensional model and design customized titanium alloy lunate prosthesis. Then Geomagic Studio 2017 software and Solidworks 2017 software were used to construct the three-dimensional finite element models of a normal wrist joint (normal model) and a wrist joint with lunate prosthesis after replacement (replacement model). The stress distribution and deformation of the wrist joint before and after replacement were analyzed for flexion at and 15°, 30°, 48.42°, extension at 15°, 30°, and 38.04°, ulnar deviation at 10°, 20°, and 35.68°, and radial deviation at 5°, 15°, and 26.41° by the ANSYS 17.0 finite element analysis software. And the stress distribution of lunate bone and lunate prosthesis were also observed. Results The three-dimensional finite element models of wrist joint before and after replacement were successfully constructed. At different range of motion of flexion, extension, ulnar deviation, and radial deviation, there were some differences in the number of nodes and units in the grid models. In the four directions of flexion, extension, ulnar deviation, and radial deviation, the maximum deformation of wrist joint in normal model and replacement model occurred in the radial side, and the values increased gradually with the increase of the range of motion. The maximum stress of the wrist joint increased gradually with the increase of the range of motion, and at maximum range of motion, the stress was concentrated on the proximal radius, showing an overall trend of moving from the radial wrist to the proximal radius. The maximum stress of normal lunate bone increased gradually with the increase of range of motion in different directions, and the stress position also changed. The maximum stress of lunate prosthesis was concentrated on the ulnar side of the prosthesis, which increased gradually with the increase of the range of motion in flexion, and decreased gradually with the increase of the range of motion in extension, ulnar deviation, and radialis deviation. The stress on prosthesis increased significantly when compared with that on normal lunate bone. Conclusion The customized titanium alloy lunate prosthesis does not change the wrist joint load transfer mode, which provided data support for the clinical application of the prosthesis.

    Release date:2023-07-12 09:34 Export PDF Favorites Scan
  • Biomechanical analysis of ankle-foot complex during a typical Tai Chi movement−Brush Knee and Twist Step

    The purpose of this study is to analyze the biomechanics of ankle cartilage and ligaments during a typical Tai Chi movement–Brush Knee and Twist Step (BKTS). The kinematic and kinetic data were acquired in one experienced male Tai Chi practitioner while performing BKTS and in normal walking. The measured parameters were used as loading and boundary conditions for further finite element analysis. This study showed that the contact stress of the ankle joint during BKTS was generally less than that during walking. However, the maximum tensile force of the anterior talofibular ligament, the calcaneofibular ligament and the posterior talofibular ligament during BKTS was 130 N, 169 N and 89 N, respectively, while it was only 57 N, 119 N and 48 N during walking. Therefore, patients with arthritis of the ankle can properly practice Tai Chi. Practitioners with sprained lateral ligaments of the ankle joint were suggested to properly reduce the ankle movement range during BKTS.

    Release date:2021-04-21 04:23 Export PDF Favorites Scan
  • Biomechanical effects of three internal fixation modes on femoral subtrochanteric spiral fractures in osteoporotic patients by finite element analysis

    Objective The biomechanical characteristics of three internal fixation modes for femoral subtrochanteric spiral fracture in osteoporotic patients were compared and analyzed by finite element technology, so as to provide the basis for the optimization of fixation methods for femoral subtrochanteric spiral fracture. MethodsTen female patients with osteoporosis and femoral subtrochanteric spiral fractures caused by trauma, aged 65-75 years old, with a height of 160-170 cm and a body weight mass of 60-70 kg, were selected as the study subjects. The femur was scanned by spiral CT and a three-dimensional model of the femur was established by digital technology. The computer aided design models of proximal intramedullary nail (PFN), proximal femoral locking plate (PFLP), and the combination of the two (PFLP+PFN) were constructed under the condition of subtrochanteric fracture. Then the same load of 500 N was applied to the femoral head, and the stress distribution of the internal fixators, the stress distribution of the femur, and the displacement of femur after fracture fixation were compared and analyzed under the three finite element internal fixation modes, so as to evaluate the fixation effect. ResultsIn the PFLP fixation mode, the stress of the plate was mainly concentrated in the main screw channel, the stresses of the different part of the plate were not equal, and gradually decreased from the head to the tail. In the PFN fixation mode, the stress was concentrated in the upper part of the lateral middle segment. In the PFLP+PFN fixation mode, the maximum stress appeared between the first and the second screws in the lower segment, and the maximum stress appeared in the lateral part of the middle segment of the PFN. The maximum stress of PFLP+PFN fixation mode was significantly higher than that of PFLP fixation mode, but significantly lower than that of PFN fixation mode (P<0.05). In PFLP and PFN fixation modes, the maximum stress of femur appeared in the medial and lateral cortical bone of the middle femur and the lower side of the lowest screw. In PFLP+PFN fixation mode, the stress of femur concentrated in the medial and lateral of the middle femur. There was no significant difference in the maximum stress of femur among the three finite element fixation modes (P>0.05). The maximum displacement occurred at the femoral head after three finite element fixation modes were used to fix subtrochanteric femoral fractures. The maximum displacement of femur in PFLP fixation mode was the largest, followed by PFN, and PFLP+PFN was the minimum, with significant differences (P<0.05). ConclusionUnder static loading conditions, the PFLP+PFN fixation mode produces the smallest maximum displacement when compared with the single PFN and PFLP fixation modes, but its maximum plate stress is greater than the single PFN and PFLP fixation mode, suggesting that the combination mode has higher stability, but the plate load is greater, and the possibility of fixation failure is higher.

    Release date:2023-06-07 11:13 Export PDF Favorites Scan
  • Simulation study of spinal cord stimulation evoked compound action potential

    Spinal cord stimulation (SCS) for pain is usually implanted as an open loop system using unchanged parameters. To avoid the under and over stimulation caused by lead migration, evoked compound action potentials (ECAP) is used as feedback signal to change the stimulating parameters. This study established a simulation model of ECAP recording to investigate the relationship between ECAP component and dorsal column (DC) fiber recruitment. Finite element model of SCS and multi-compartment model of sensory fiber were coupled to calculate the single fiber action potential (SFAP) caused by single fiber in different spinal cord regions. The synthetized ECAP, superimposition of SFAP, could be considered as an index of DC fiber excitation degree, because the position of crests and amplitude of ECAP corresponds to different fiber diameters. When 10% or less DC fibers were excited, the crests corresponded to fibers with large diameters. When 20% or more DC fibers were excited, ECAP showed a slow conduction crest, which corresponded to fibers with small diameters. The amplitude of this slow conduction crest increased as the stimulating intensity increased while the amplitude of the fast conduction crest almost remained unchanged. Therefore, the simulated ECAP signal in this paper could be used to evaluate the degree of excitation of DC fibers. This SCS-ECAP model may provide theoretical basis for future clinical application of close loop SCS base on ECAP.

    Release date:2021-06-18 04:50 Export PDF Favorites Scan
  • Contact Analysis between Artificial Humeral Head and Glenoid Fossa During Humeral External Rotation

    We developed a three-dimensional finite element model of the shoulder glenohumeral joint after shoulder arthroplasty including humerus shaft, scapular, scapular cartilage and eight muscles, while each of the muscles was simulated with 50 spring elements. To reduce the element number and improve the analytical precision, we used mixed tetrahedral and hexahedral elements in the model. We then used the model to calculate the biomechanics of the shoulder glenohumeral joint after hemiarthroplasty during humeral external rotation. Results showed that the maximum joint reaction force was 374.72 N and the maximum contact stress was 6.573 MPa together with the contact areas at 40° external rotation. These might be one of the reasons for prosthetic disarticulation, and would provide theoretical bases to prosthetic design.

    Release date: Export PDF Favorites Scan
  • Three-dimensional Finite Element Analysis to T-shaped Fracture of Pelvis in Sitting Position

    We developed a three-dimensional finite element model of the pelvis. According to Letournel methods, we established a pelvis model of T-shaped fracture with its three different fixation systems, i.e. double column reconstruction plates, anterior column plate combined with posterior column screws and anterior column plate combined with quadrilateral area screws. It was found that the pelvic model was effective and could be used to simulate the mechanical behavior of the pelvis. Three fixation systems had great therapeutic effect on the T-shaped fracture. All fixation systems could increase the stiffness of the model, decrease the stress concentration level and decrease the displacement difference along the fracture line. The quadrilateral area screws, which were drilled into cortical bone, could generate beneficial effect on the T-type fracture. Therefore, the third fixation system mentioned above (i.e. the anterior column plate combined with quadrilateral area screws) has the best biomechanical stability to the T-type fracture.

    Release date: Export PDF Favorites Scan
  • Effect of sinus diameter on the opening and closing performance of aortic valve under the expansion of aortic root

    This study aims to explore the effect of aortic sinus diameter on aortic valve opening and closing performance in the case of no obvious disease of aortic valve and annulus and continuous dilation of aortic root. A total of 25 three-dimensional aortic root models with different aortic sinus and root diameters were constructed according to the size of clinical surgical guidance. The valve sinus diameter DS is set to 32, 36, 40, 44 and 48 mm, respectively, and the aortic root diameter DA is set to 26, 27, 28, 29 and 30 mm, respectively. Through the structural mechanics calculation with the finite element software, the maximum stress, valve orifice area, contact force and other parameters of the model are analyzed to evaluate the valve opening and closing performance under the dilated state. The study found that aortic valve stenosis occurs when the DS = 32 mm, DA = 26, 27 mm and DS = 36 mm, DA = 26 mm. Aortic regurgitation occurs when the DS = 32, 36 and 40 mm, DA = 30 mm and DS = 44, 48 mm, DA = 29, 30 mm. The other 15 models had normal valve movement. The results showed that the size of the aortic sinus affected the opening and closing performance of the aortic valve. The smaller sinus diameter adapted with the larger root diameter and the larger sinus diameter adapted with the smaller root diameter. When the sinus diameter is 40 mm, the mechanical performance of the valve are good and it can well adapt with the relatively large range of aortic root dilation.

    Release date:2019-12-17 10:44 Export PDF Favorites Scan
9 pages Previous 1 2 3 ... 9 Next

Format

Content