west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "image processing" 15 results
  • Research of New Coloration Biochip Reader Based on Charge-coupled Device

    Aiming at long signal acquisition time, low flux, bad signal-to-noise ratio and low intelligence in coloration biochip reader, a new kind of rapid device with high flux was developed. The device consisted of hardware system and software system. It used a charge-coupled device (CCD) as the photoelectric sensor elements and obtained the biochip microarray image. The device integrated the embedded operating system based on i.MX6 chip. The microarray image processing, data analysis and result output were achieved through the code information of the software chip. Experiments with the standard grayscale sheet and standard format chip were carried out. The results showed that the maximum measurement error was less than 0.1%, the value of R2 was 98.7%, and the value of CV was 1.096 1%. The comparison results of 200 samples showed that detection performance of the proposed device was better than that of the same kind of marketed equipment.

    Release date:2016-10-02 04:55 Export PDF Favorites Scan
  • Research on Measuring the Velocity and Displacement of the Coxa and Knee Based on Video Image Processing

    Based on repeated experiments as well as continuous researching and improving, an efficient scheme to measure velocity and displacement of the coxa and knee movements based on video image processing technique is presented in this paper. The scheme performed precise and real-time quantitative measurements of 2D velocity or displacement of the coxa and knee using a video camera mounted on one side of the healing and training beds. The beds were based on simplified pinhole projection model. In addition, we used a special-designed auxiliary calibration target, composed by 24 circle points uniformly located on two concentric circles and two straight rods which can rotate freely along the concentric center within the vertical plane, to do the measurements. Experiments carried out in our laboratory showed that the proposed scheme could basically satisfy the requirements about precision and processing speed of such kind of system, and would be very suitable to be applied to smart evaluation/training and healing system for muscles/balance function disability as an advanced and intuitional helping method.

    Release date: Export PDF Favorites Scan
  • A Bibliometrics Study of Literature on Medical Image Processing for the Past Ten Years

    We searched and retrieved literature on the topic of medical image processing published on SCI journals in the past 10 years. We then imported the retrieved literature into TDA for data cleanup before data analysis and processing by EXCLE and UCINET to generate tables and figures that could indicate disciplinary correlation and research hotspots from the perspective of bibliometrics. The results indicated that people in Europe and USA were leading researchers on medical image processing with close international cooperation. Many disciplines contributed to the fast development of medical image processing with intense interdisciplinary researches. The papers that we found show recent research hotspots of the algorithm, system, model, image and segmentation in the field of medical image processing. Cluster analysis on key words of high frequency demonstrated complicated clustering relationship.

    Release date: Export PDF Favorites Scan
  • A nucleus location method based on distance estimation

    To locate the nuclei in hematoxylin-eosin (HE) stained section images more simply, efficiently and accurately, a new method based on distance estimation is proposed in this paper, which shows a new mind on locating the nuclei from a clump image. Different from the mainstream methods, proposed method avoids the operations of searching the combined singles. It can directly locate the nuclei in a full image. Furthermore, when the distance estimation built on the matrix sequence of distance rough estimating (MSDRE) is combined with the fact that a center of a convex region must have the farthest distance to the boundary, it can fix the positions of nuclei quickly and precisely. In addition, a high accuracy and efficiency are achieved by this method in experiments, with the precision of 95.26% and efficiency of 1.54 second per thousand nuclei, which are better than the mainstream methods in recognizing nucleus clump samples. Proposed method increases the efficiency of nuclear location while maintaining the location's accuracy. This can be helpful for the automatic analysis system of HE images by improving the real-time performance and promoting the application of related researches.

    Release date:2018-08-23 03:47 Export PDF Favorites Scan
  • Research on adaptive pulse signal extraction algorithm based on fingertip video image

    In order to solve the saturation distortion phenomenon of R component in fingertip video image, this paper proposes an iterative threshold segmentation algorithm, which adaptively generates the region to be detected for the R component, and extracts the human pulse signal by calculating the gray mean value of the region to be detected. The original pulse signal has baseline drift and high frequency noise. Combining with the characteristics of pulse signal, a zero phase digital filter is designed to filter out noise interference. Fingertip video images are collected on different smartphones, and the region to be detected is extracted by the algorithm proposed in this paper. Considering that the fingertip’s pressure will be different during each measurement, this paper makes a comparative analysis of pulse signals extracted under different pressures. In order to verify the accuracy of the algorithm proposed in this paper in heart rate detection, a comparative experiment of heart rate detection was conducted. The results show that the algorithm proposed in this paper can accurately extract human heart rate information and has certain portability, which provides certain theoretical help for further development of physiological monitoring application on smartphone platform.

    Release date:2020-04-18 10:01 Export PDF Favorites Scan
  • Brain magnetic resonance image registration based on parallel lightweight convolution and multi-scale fusion

    Medical image registration plays an important role in medical diagnosis and treatment planning. However, the current registration methods based on deep learning still face some challenges, such as insufficient ability to extract global information, large number of network model parameters, slow reasoning speed and so on. Therefore, this paper proposed a new model LCU-Net, which used parallel lightweight convolution to improve the ability of global information extraction. The problem of large number of network parameters and slow inference speed was solved by multi-scale fusion. The experimental results showed that the Dice coefficient of LCU-Net reached 0.823, the Hausdorff distance was 1.258, and the number of network parameters was reduced by about one quarter compared with that before multi-scale fusion. The proposed algorithm shows remarkable advantages in medical image registration tasks, and it not only surpasses the existing comparison algorithms in performance, but also has excellent generalization performance and wide application prospects.

    Release date: Export PDF Favorites Scan
  • Design and implementation of an automatic analysis system for magnetic resonance quality detection based on QT

    The quality inspection of magnetic resonance imaging (MRI) performance parameters is an important means to ensure the image quality and the reliability of diagnosis results. There are some problems in the manual calculation and eye recognition of the quality inspection parameters, such as strong subjectivity and low efficiency. In view of these facts, an automatic analysis system for MRI quality detection based on QT is proposed and implemented in C++ language. The image processing algorithm is introduced to automatically measure and calculate the quality inspection parameters. The software with comprehensive functions is designed to systematically manage the quality inspection information of MRI. The experimental results show that the automatically calculated parameters are consistent with the manually calculated ones. Accordingly, the accuracy and reliability of the algorithm is verified. The whole system is efficient, convenient and easy to operate, and it can meet the actual needs of MRI quality inspection.

    Release date:2019-08-12 02:37 Export PDF Favorites Scan
  • Study on precise localization of intraoperative matrix electrode

    In order to accurately localize the image coordinates and serial numbers of intraoperative subdural matrix electrodes, a matrix electrode localization algorithm for image processing is proposed in this paper. Firstly, by using point-by-point extended electrode location algorithm, the electrode is expanded point-by-point vertically and horizontally, and the initial coordinates and serial numbers of each electrode are determined. Secondly, the single electrode coordinate region extraction algorithm is used to determine the best coordinates of each electrode, so that the image coordinates and serial numbers of all electrodes are determined point-by-point. The results show that the positioning accuracy of electrode serial number is 100%, and the electrode coordinate positioning error is less than 2 mm. The algorithms in this paper can accurately localize the image coordinates and the serial numbers of a matrix electrode arranged in an arc, which could aid drawing of cortical function mapping, and achieve precise positioning of brain functional areas, so that it can be widely used in neuroscience research and clinical application based on electrocorticogram analysis.

    Release date:2017-12-21 05:21 Export PDF Favorites Scan
  • Development and validation of an automatic diagnostic tool for lumbar stability based on deep learning

    Objective To develop an automatic diagnostic tool based on deep learning for lumbar spine stability and validate diagnostic accuracy. Methods Preoperative lumbar hyper-flexion and hyper-extension X-ray films were collected from 153 patients with lumbar disease. The following 5 key points were marked by 3 orthopedic surgeons: L4 posteroinferior, anterior inferior angles as well as L5 posterosuperior, anterior superior, and posterior inferior angles. The labeling results of each surgeon were preserved independently, and a total of three sets of labeling results were obtained. A total of 306 lumbar X-ray films were randomly divided into training (n=156), validation (n=50), and test (n=100) sets in a ratio of 3∶1∶2. A new neural network architecture, Swin-PGNet was proposed, which was trained using annotated radiograph images to automatically locate the lumbar vertebral key points and calculate L4, 5 intervertebral Cobb angle and L4 lumbar sliding distance through the predicted key points. The mean error and intra-class correlation coefficient (ICC) were used as an evaluation index, to compare the differences between surgeons’ annotations and Swin-PGNet on the three tasks (key point positioning, Cobb angle measurement, and lumbar sliding distance measurement). Meanwhile, the change of Cobb angle more than 11° was taken as the criterion of lumbar instability, and the lumbar sliding distance more than 3 mm was taken as the criterion of lumbar spondylolisthesis. The accuracy of surgeon annotation and Swin-PGNet in judging lumbar instability was compared. Results ① Key point: The mean error of key point location by Swin-PGNet was (1.407±0.939) mm, and by different surgeons was (3.034±2.612) mm. ② Cobb angle: The mean error of Swin-PGNet was (2.062±1.352)° and the mean error of surgeons was (3.580±2.338)°. There was no significant difference between Swin-PGNet and surgeons (P>0.05), but there was a significant difference between different surgeons (P<0.05). ③ Lumbar sliding distance: The mean error of Swin-PGNet was (1.656±0.878) mm and the mean error of surgeons was (1.884±1.612) mm. There was no significant difference between Swin-PGNet and surgeons and between different surgeons (P>0.05). The accuracy of lumbar instability diagnosed by surgeons and Swin-PGNet was 75.3% and 84.0%, respectively. The accuracy of lumbar spondylolisthesis diagnosed by surgeons and Swin-PGNet was 70.7% and 71.3%, respectively. There was no significant difference between Swin-PGNet and surgeons, as well as between different surgeons (P>0.05). ④ Consistency of lumbar stability diagnosis: The ICC of Cobb angle among different surgeons was 0.913 [95%CI (0.898, 0.934)] (P<0.05), and the ICC of lumbar sliding distance was 0.741 [95%CI (0.729, 0.796)] (P<0.05). The result showed that the annotating of the three surgeons were consistent. The ICC of Cobb angle between Swin-PGNet and surgeons was 0.922 [95%CI (0.891, 0.938)] (P<0.05), and the ICC of lumbar sliding distance was 0.748 [95%CI(0.726, 0.783)] (P<0.05). The result showed that the annotating of Swin-PGNet were consistent with those of surgeons. ConclusionThe automatic diagnostic tool for lumbar instability constructed based on deep learning can realize the automatic identification of lumbar instability and spondylolisthesis accurately and conveniently, which can effectively assist clinical diagnosis.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
  • Preliminary study on differential diagnosis of liver cancer and hepatic hemangioma by texture analysis of non-enhanced CT images

    Objective To determine feasibility of texture analysis of non-enhanced CT scan for differential diagnosis of liver cancer and hepatic hemangioma. Methods Fifty-six patients with liver cancer or hepatic hemangioma confirmed by pathology were enrolled in this retrospective study. After exclusion of images of 4 patients with artifacts and lesion diameter less than 1.0 cm, images of 52 patients (57 lesions) were available to further analyze. Texture features derived from the gray-level histogram, co-occurrence and run-length matrix, absolute gradient, autoregressive model, and wavelet transform were calculated. Fisher, probability of classification error and average correlation (POE+ACC), and mutual information coefficients (MI) were used to extract 10 optimized texture features. The texture characteristics were analyzed by using linear discriminant analysis (LDA) and nonlinear discriminant analysis (NDA) provided by B11 module in the Mazda software, the minimum error probability of differential diagnosis of liver cancer and hepatic hemangioma was calculated. Most discriminating features (MDF) of LDA was applied to K nearest neighbor classification (KNN); NDA to extract the data used in artificial neural network (ANN) for differential diagnosis. Results The NDA/ANN-POE+ACC was the best for identifying liver cancer and hepatic hemangioma, and the minimum error probability was the lowest as compared with the LDA/KNN-Fisher, LDA/KNN-POE+ACC, LDA/KNN-MI, NDA/ANN-Fisher, and NDA/ANN-MI respectively, the differences were statistically significant (χ2=4.56, 4.26, 3.14, 3.14, 3.33;P=0.020, 0.018, 0.026, 0.026, 0.022). Conclusions The minimum error probability is low for different texture feature selection methods and different analysis methods of Mazda texture analysis software in identifying liver cancer and hepatic hemangioma, and NDA/ANN-POE+ACC method is best. So it is feasible to use texture analysis of non-enhanced CT images to identify liver cancer and hepatic hemangioma.

    Release date:2017-02-20 06:43 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content