west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "intensity" 56 results
  • The Application of High Intensity Focused Ultrasound in the Tumor Treatment

    bjectiveTo evaluate the efficacy and limits of high intensity focused ultrasound (HIFU) in tumor treatment. MethodsThe references about the application of HIFU in tumor treatment in recent years were reviewed.ResultsHIFU caused localized hyperthermia at predictable depth in a few seconds to make the tumor tissue coagulative necrosis without injuring surrounding tissue. HIFU treatment had the advantages of low morbidity, noninvasiveness, avoidance of systemic side effects, and repeatitiveness. However, the utilization of HIFU sometimes could be limited by some factors such as imaging technique, organ movement, incomplete tissue destruction, etc.ConclusionHIFU is a promising noninvasive therapy for tumor treatment, though there are lots of problems to be further studied.

    Release date:2016-08-28 05:10 Export PDF Favorites Scan
  • Differential diagnosis significance of 3.0T MRI united-sequence examination forbenign and malignant breast lesions

    Objective To explore the differential diagnosis significance of 3.0T MRI united-sequences examination in the diagnosis of benign and malignant breast lesions. Methods A total of 67 breast lesions of 59 patients were collected prospectively, which be treated at the Sichuan Provincial People’s Hospital during July 2015 to January 2017. All patients were underwent bilateral breast 3.0T magnetic resonance plain scan, diffusion weighted imaging, and dynamic enhanced scan successively before surgical operation. Analysis of morphological features of the benign and malignant breast lesions, the time-signal intensity curve (TIC), the apparent diffusion coefficient (ADC), and the combination diagnosis of them were performed. Results Of all 59 patients, 67 lesions were confirmed by histopathology, including 18 benign lesions and 49 malignant lesions. The morphological features (including margin, shape, border, and evenness), the types of TIC of dynamic enhancement, and ADC value between the benign lesions and malignant lesions were statistically significant (P<0.05). The sensitivity and specificity of Fischer scoring system was 89.8% (44/49) and 61.1% (11/18) respectively. The sensitivity and specificity of TIC types was 83.7% (41/49) and 77.8% (14/18) respectively. The diagnostic threshold of ADC value was 1.012×10–3 mm2/s, with the sensitivity and specificity for the diagnosis was 91.8% (45/49) and 83.3% (15/18) respectively. The sensitivity and specificity of the combination of Fischer scoring system and TIC type for diagnosis between benign and malignant breast lesions was 95.9% (47/49) and 72.2% (13/18) respectively. The sensitivity and specificity of the combination of Fischer scoring system, TIC type, and ADC value for benign and malignant breast lesions was 98.0% (48/49) and 83.3% (15/18) respectively. Conclusion The combination of Fischer scoring system, TIC type, and diffusion-weighted imaging for the differential diagnosis between benign lesions and malignant lesions was more effective than single imaging method.

    Release date:2018-07-18 01:46 Export PDF Favorites Scan
  • STUDY OF THE MAGNETIC PIECE DRESSINGS OF DIFFERENT INTENSITIES ON THE EFFECT OF SURVIVAL OF SKIN FLAPS AND HEALING OF INCISIONAL WOUNDS

    The comparative study of local application of magnetic piece dressings of different intensities (Gs) on the effect of survival of 48 skin flaps (2×5cm in size) and the healing of the incisional wornds was reported. Twelve Japanese long ear white rabbits were used for this study. It was noted that the magnetic field intensity of 200or 400 Gs showed remarkable increase of the area of survival of the skin flaps and enhancement of the healing of the incisional wounds.

    Release date:2016-09-01 11:38 Export PDF Favorites Scan
  • A Treatment Plan Dose Interpolation Algorithm Based on Gradient Feature in Intensity-modulated Radiation Therapy

    The dose data produced by treatment plan system (TPS) in intensity-modulated radiation therapy (IMRT) has many gradient edge points. Considering this feature we proposed a new interpolation algorithm called treatment plan dose interpolation algorithm based on gradient feature in intensity-modulated radiation therapy (TDAGI), which improves the Canny algorithm to detect the gradient edge points and non-edge points by using the gradient information in the dose data plane. For each gradient edge point, the corresponding gradient profile was traced and the profile's sharpness was calculated, and for each non-edge point, the dispersion was calculated. With the sharpness or dispersion, the kernel coefficients of bi-cubic interpolation can be obtained and can be used as the central point to complete the bi-cubic interpolation calculation. Compared with bi-cubic interpolation and bilinear interpolation, the TDAGI algorithm is more accurate. Furthermore, the TDAGI algorithm has the advantage of gradient keeping. Therefore, TDAGI can be used as an alternative method in the dose interpolation of TPS in IMRT.

    Release date:2016-12-19 11:20 Export PDF Favorites Scan
  • A meta-analysis of the comparison of intervention effects of high-intensity interval training and moderate-intensity continuous training on patients with metabolic syndrome

    Objective To explore the difference of intervention effect between high-intensity interval training (HIIT) and moderate-intensity continuous training (MICT) on patients with metabolic syndrome (MetS). Methods China National Knowledge Infrastructure, WanFang Data, PubMed, Web of Science and EBSCO were searched for randomized controlled trials (RCTs) till May 2022. Two reviewers independently reviewed the literature, extracted data, and assessed the risk of bias of included RCTs. Comprehensive Meta-Analysis software was used for meta-analysis. Result A total of 5 RCTs were included, including 216 patients. The results of meta-analysis showed that: except fasting blood glucose, high-density lipoprotein cholesterol, systolic blood pressure, waist circumference, body mass index and body fat percentage (P>0.005), low-density lipoprotein cholesterol [mean difference (MD)=−7.487 mg/dL, 95% confidence interval (CI) (−12.543, −2.431) mg/dL, P=0.004], total cholesterol [MD=−11.487 mg/dL, 95%CI (−16.523, −6.452) mg/dL, P<0.001], triglycerides [MD=−26.296 mg/dL, 95%CI (−50.557, −2.035) mg/dL, P=0.034] and diastolic blood pressure [MD=−2.770 mm Hg (1 mm Hg=0.133 kPa), 95%CI (−5.131, −0.409) mm Hg, P=0.021] of HIIT were better than MICT. Conclusion In terms of blood glucose indicators and morphological indicators, the effect of HIIT group and MICT group was similar, but the effect of HIIT on blood lipid indicators and blood pressure indicators of patients with MetS was better than MICT.

    Release date:2023-02-14 05:33 Export PDF Favorites Scan
  • Broadband subharmonic active cavitation imaging with high cavitation to tissue ratio

    To improve the cavitation-to-tissue ratio (CTR) of cavitation imaging during the treatment with high-intensity focused ultrasound (HIFU), we proposed a pulse inversion based broadband subharmonic cavitation imaging method (PIBSHI). Due to the fact that the subharmonic signal is a unique nonlinear vibration characteristic of cavitation bubbles, we extracted the broadband subharmonic signal to get a high-CTR cavitation imaging. The simulation showed that the subharmonic signal produced by cavitating bubbles with different sizes varied, and the signal was stronger than other subharmonics when the bubbles’ resonant frequency was close to 1/2 subharmonic frequency. Further experiment results demonstrated that compared with the conventional B-mode images, broadband subharmonic cavitation imaging (BSHI) has improved the CTR by 5.7 dB, and the CTR was further improved by 3.4 dB when combined with pulse inversion (PI) technology. Moreover, when the bandwidth was set to 100%~140% of the 1/2 subharmonic frequency in PIBSHI, the CTR was the highest and the imaging showed the optimal quality. The study may have reference value for the development of precise cavitation imaging during HIFU treatment, and contribute to improve the safety of HIFU treatment.

    Release date:2020-02-18 09:21 Export PDF Favorites Scan
  • Effect of High Intensity Focused Ultrasound on Immunity of Patients with Advanced Primary Liver Cancer

    【Abstract】ObjectiveTo investigate the effect of high intensity focused ultrasound (HIFU) on the immunity of patients with advanced primary liver cancer (PLC). MethodsForty cases of PLC admitted to our institution from Mar. 2003 to Dec. 2003 were included in this study. Patients were divided into 2 groups and received either HIFU or radiofrequency ablation (RFA) treatment randomly. CD3, CD4, CD8, CD4/CD8, NK, IL-2, TNF were chosen to assess the immune status before and after treatment. The results were compared statistically. ResultsThe survival rate after HIFU was 80.0%, 61.1%, 42.9%, 33.3% at 3 months, 6 months, 9 months and 1 year respectively, which was similar to that after RFA treatment. The changes of immunity parameters of CD3, CD4, CD8, CD4/CD8, NK, IL-2 and TNF were not significant after HIFU treatment. In addition, the differences of those parameters between HIFU group and RFA group were insignificant. ConclusionThere are no detrimental effects on immunity in the early period after HIFU treatment.

    Release date:2016-09-08 11:52 Export PDF Favorites Scan
  • Study on the regulatory effect of low intensity retinal ultrasound stimulation on the neural activity of visual cortex

    Low-intensity ultrasound stimulation of the retina has the ability to modulate neural activity in the primary visual cortex (V1), however, it is currently unclear how different intensities and durations of ultrasonic stimulation of the retina modulate neural activity in V1. In this paper, we recorded local field potential (LFP) signals in the V1 brain region of mice under different ultrasound intensities and different stimulation times. The amplitude of LFP corresponding to 1 s before ultrasound stimulation to 2 s after stimulation (–1–2 s) was analyzed, including the power and sample entropy of delta, theta, alpha beta, and low gamma frequency bands. The experimental results showed that, as the stimulation intensity increased, the peak value of the LFP in the visual cortex showed a linear upward trend; the power in the delta and theta frequency bands showed a linear upward trend, and the sample entropy showed a linear downward trend. With increases of stimulation duration, the peak value of the LFP in the visual cortex showed an upward trend, and the upward trend gradually weakened; the power in the delta frequency band showed an upward trend, the sample entropy showed a linear upward trend, and the sample entropy in the theta frequency band showed a downward trend. The results show that low-intensity ultrasonic stimulation of the retina has a significant modulatory effect on neural activity in the visual cortex. The study provides insights into the mechanisms by which ultrasonic stimulation regulates visual system function. Furthermore, it clarifies the patterns of parameter selection, facilitating the development of personalized multi-parameter modulation for the treatment of visual neural degeneration, retinal disorders and related research areas.

    Release date:2024-12-27 03:50 Export PDF Favorites Scan
  • Research progress on magnetic resonance guided focused ultrasound therapy for drug-resistant epilepsy

    Magnetic resonance-guided focused ultrasound (MRgFUS) is an emerging therapeutic ultrasound modality that integrates the precise localization capabilities of magnetic resonance imaging with the non-invasive therapeutic properties of focused ultrasound (FUS). This technology enables accurate targeting of deep brain structures and facilitates the treatment of various central nervous system disorders, including essential tremor, Parkinson's disease, and chronic neuropathic pain, through mechanisms such as ablation of diseased tissue, modulation of neural activity, and disruption of the blood-brain barrier. However, its efficacy and safety in the treatment of drug-resistant epilepsy (DRE) remain subjects of ongoing research. Consequently, MRgFUS is under investigation to ascertain its effectiveness and safety profile for treating DRE. This review aims to summarize the current progress in the application of MRgFUS for DRE therapy.

    Release date:2025-03-19 01:37 Export PDF Favorites Scan
  • The prospective clinical controlled study of high intensity focused ultrasound and uterine artery embolization in the treatment of cesarean scar pregnancy

    Objective To investigate the clinical effect of high intensity focused ultrasound (HIFU) and uterine artery embolization (UAE) in the treatment of cesarean scar pregnancy (CSP). Methods A total of 152 patients with CSP diagnosed by B-type ultrasonography were enrolled prospectively in this study from June 2014 to May 2016 in Chengdu Women and Children’s Central Hospital and Suining Central Hospital. Six patients from Chengdu Women and Children’s Central Hospital and 84 from Suining Central Hospital for Volunteered HIFU treatment were regarded as observation group. The other 62 patients from Chengdu Women and Children’s Central Hospital were selected to accept UAE treatment voluntarily were designated as control group. The clinical efficacy and therapeutic safety of the two groups were compared after the treatment. Results Eighty-two patients (91.1%) in the observation group and 32 (51.6%) in the control group had a bleeding volume equal to 100 mL or lower during complete curettage of uterine cavity (P<0.05). The hospitalization expenses of the above two groups were respectively (25 126.51±1 473.49) and (32 928.42 ±1 579.35) yuan (P<0.05). The hospitalization time was (11.03±1.52) and (10.65±1.87) days respectively, and the difference was not statistically significant (P>0.05). There was no significant difference in the normal rate of human chorionic gonadotropin recovery between the observation group and the control group at 14 days after treatment (P>0.05). Eighty-seven patients (96.7%) in the observation group and 51 (82.3%) in the control group had their menstrual recovery to normal level at 2 months after treatment, and the difference was statistically significant (P<0.05). The incidence of postoperative complications was 1.1% and 6.4% in the observation group and the control group, respectively, and the difference was not statistically significant (P>0.05). Conclusions HIFU in the treatment of CSP is safe and effective. Compared with UAE, HIFU requires less cost with fewer complications, which is worth promoting.

    Release date:2017-05-18 01:09 Export PDF Favorites Scan
6 pages Previous 1 2 3 ... 6 Next

Format

Content