To investigate the effects of postoperative fusion implantation on the mesoscopic biomechanical properties of vertebrae and bone tissue osteogenesis in idiopathic scoliosis, a macroscopic finite element model of the postoperative fusion device was developed, and a mesoscopic model of the bone unit was developed using the Saint Venant sub-model approach. To simulate human physiological conditions, the differences in biomechanical properties between macroscopic cortical bone and mesoscopic bone units under the same boundary conditions were studied, and the effects of fusion implantation on bone tissue growth at the mesoscopic scale were analyzed. The results showed that the stresses in the mesoscopic structure of the lumbar spine increased compared to the macroscopic structure, and the mesoscopic stress in this case is 2.606 to 5.958 times of the macroscopic stress; the stresses in the upper bone unit of the fusion device were greater than those in the lower part; the average stresses in the upper vertebral body end surfaces were ranked in the order of right, left, posterior and anterior; the stresses in the lower vertebral body were ranked in the order of left, posterior, right and anterior; and rotation was the condition with the greatest stress value in the bone unit. It is hypothesized that bone tissue osteogenesis is better on the upper face of the fusion than on the lower face, and that bone tissue growth rate on the upper face is in the order of right, left, posterior, and anterior; while on the lower face, it is in the order of left, posterior, right, and anterior; and that patients’ constant rotational movements after surgery is conducive to bone growth. The results of the study may provide a theoretical basis for the design of surgical protocols and optimization of fusion devices for idiopathic scoliosis.
This study aims to investigate the range of motion (ROM) and the stress variation in the intervertebral disc and the vertebral body on adjacent segments and the influence of force transmission mode after the dynamic cervical implant (DCI) surgery. Two types of surgery, DCI implantation and interbody fusion were used to establish the finite element model of the cervical C5, 6 segment degeneration treatment. The ROM and the adjacent discs and vertebral body stresses of two procedures under flexion, extension, lateral bending and axial rotation working conditions were analyzed. The results showed that ROM of the surgical segment in DCI model was well preserved and could restore to the normal ROM distributions (reduction of the amplitude was less than 25%), and the kinetic characteristics of adjacent segments was less affected. In fusion surgery model, however, ROM of the surgical segment was reduced by 86%-91%, while ROM, disc stress and vertebral stress of adjacent segments were increased significantly, and stress of the C5 vertebral body was increased up to 171.21%. Therefore DCI surgery has relatively small influence on cervical ROM and stress. The study provides a theoretical basis for DCI and fusion surgery in clinic.
Lower extremity movement is a complex and large range of limb movement. Arterial stents implanted in lower extremity are prone to complex mechanical deformation, so the stent is required to have high comprehensive mechanical properties. In order to evaluate the mechanical property of different stents, in this paper, finite element method was used to simulate and compare the mechanical properties of six nitinol stents (Absolute Pro, Complete SE, Lifestent, Protégé EverFlex, Pulsar-35 and New) under different deformation modes, such as radial compression, axial compression/tension, bending and torsion, and the radial support performance of the stents was verified by experiments. The results showed that the comprehensive performance of New stent was better than other stents. Among which the radial support performance was higher than Absolute Pro and Pulsar-35 stent, the axial support performance was better than Complete SE, Lifestent and Protégé EverFlex stent, the flexibility was superior to Protégé Everflex stent, and the torsion performance was better than Complete SE, Lifestent and Protégé Everflex stent. The TTR2 type radial support force tester was used to test the radial support performance of 6 types, and the finite element analysis results were verified. The mechanical properties of the stent are closely related to the structural size. The result provides a reference for choosing a suitable stent according to the needs of the diseased location in clinical applications.
Objective To review the research progress of design of bone scaffolds with different single cell structures. Methods The related literature on the study of bone scaffolds with different single cell structures at home and abroad in recent years was extensively reviewed, and the research progress was summarized. ResultsThe single cell structure of bone scaffold can be divided into regular cell structure, irregular cell structure, cell structure designed based on topology optimization theory, and cell structure designed based on triply periodic minimal surface. Different single cell structures have different structural morphology and geometric characteristics, and the selection of single cell structure directly determines the mechanical properties and biological properties of bone scaffold. It is very important to choose a reasonable cell structure for bone scaffold to replace the original bone tissue. Conclusion Bone scaffolds have been widely studied, but there are many kinds of bone scaffolds at present, and the optimization of single cell structure should be considered comprehensively, which is helpful to develop bone scaffolds with excellent performance and provide effective support for bone tissue.
【Abstract】 Objective To investigate the feasibil ity of applying enzymatic method to prepare decellularizedporcine aorta and to evaluate its biomechanical properties, immunogenicity and cell compatibil ity. Methods 0.1% trypsin- 0.01% EDTA was appl ied to extract cells from porcine aorta under 37 continuously vibrating condition and its histology and microstructure were observed. The thickness, stress-strain curve, ultimate tension stress (UTS) and strain of failure (SOF) were compared before and after decellularization for 48, 96 and 120 hours under uniaxial tensile tests, respectively. The histological change was observed at 1, 3 and 6 weeks after the decellularized tissue was implanted subcutaneously in 3 dogs. According to the HE stains and a semi-quantitative Wakitani grading method, gross changes, category and amounts of infiltrated cells and neo-capillaries were compared between pre- and post-decellularization of porcine aortae. Endothel ial cells from canine external jugular vein were seeded onto the decellularized patches to observe the cell compatibil ity. Results Microscopy and electron microscopies examination identified that cell components was completely removed from the fresh porcine aorta and Masson’ strichrome showed that the structure of matrix (fibrins) was maintained intact at 96 hours using the decellularization method. There were no significant differences in the thickness, UTS and SOF between before and after decellularization (P gt; 0.05). However, The UTS values showed a decrease tendency and SOF showed an increase tendency. The stress-strain curve also verified a decrease tendency in mechanical intensity and an increase one in ductil ity after decellularization. After implanting the acellularized matrix subcutaneously in canine, moderately lymphocyte infiltration was seen at the 1st week and the infiltration was replaced by fibroblasts accompanied by neocapillary formation at the 6th week. A semi-quantity histological evaluation showed that there were differences in gross observation, category and the numbers of the infiltrated cells between decellularized and non-decellularized tissues(P lt; 0.05). A cell monolayer was identified by HE staining and scanning electron microscopywhen the endothel ial cells were seeded onto the inner luminal surface of the scaffold, al igned at the same direction on the whole. Conclusion The decellularized porcine aortic scaffold, prepared by trypsin-EDTA extraction under continuously vibrating condition, could meet the requirements of tissue-engineering graft in biomechanical properties, immunogenicity and cell compatibil ity.
Focusing on the poor mechanical strength of porous bioceramics bone scaffold, and taking into account of the good mechanical properties of biodegradable magnesium alloy, we proposed a novel method to fabricate magnesium alloy/bioceramics composite bone scaffold with stereolithography double channels. Firstly, a scaffold structure without mutually connected double channels was designed. Then, an optimized bioceramics scaffold was fabricated according to stereolithography and gel-casing. Molten AZ31 magnesium alloy was perfused into the secondary channel of scaffold by low-pressure casting, and magnesium alloy/bioceramics composite bone scaffold was obtained when magnesium alloy was solidified. The compression test showed that the strength of bioceramics scaffold with only one channel and without magnesium alloy was (9.76±0.64) MPa, while the strength of magnesium alloy/bioceramics composite scaffold with double channels was (17.25±0.88) MPa. It can be concluded that the magnesium alloy/bioceramics composite is obviously able to improve the scaffold strength.
The pediatric cadaver impact experiments were reconstructed using the validated finite element(FE) models of the 3-year-old and 6-year-old children. The effect of parameters, such as hammer size, material parameters and thorax anatomical structure characteristics, on the impact mechanical responses of 3-year-old and 6-year-old pediatric thorax was discussed by designing reasonable finite element simulation experiments. The research results showed that the variation of thorax contact peak force for 3-year-old group was far larger than that of 6-year-old group when the child was impacted by hammers with different size, which meant that 3-year-old child was more sensitive to hammer size. The mechanical properties of thoracic organs had little influence on the thorax injury because of the small difference between 3-year-old and 6-year-old child in this research. During the impact, rib deformation led to different impact location and deformation of internal organs because the 3-year-old and 6-year-old children had different geometrical anatomical structures, such as different size of internal organs. Therefore, the injury of internal organs in the two groups was obviously different. It is of great significance to develop children finite element models with high biofidelity according to its real anatomical structures.
Objective To investigate the biological and biomechanical characteristics of acellular porcine aortic valve with dye mediated photo oxidation so that a new and better bioprosthetic valve materials can be obtained. Methods Thirty porcine aortic valves were divided into three groups with random number table. Acellular valves (n=10) were stabilized by dye mediated photo oxidation in dye mediated photo oxidation group; acellular valves (n=10) were stabilized by glutaraldehyde in glutaraldehyde group; and acellular valves (n=10) were acellularized only in acellular valves group. Thickness, appearance, histology, water content, shrinkage temperature, breaking strength and soluble protein level of acellular porcine aortic in three groups were tested respectively. Results There were light blue, soft, flexible and unshrinking valves in dye mediated photo oxidation group. Compared to valves in glutaraldehyde group, valves in dye mediated photo oxidation group had lighter thickness(0.26±0.09mm vs. 0.38±0.08mm,Plt;0.05), more water content(86.30%±4.03% vs. 71.10%±3.23%,Plt;0.05), and lower shrinkage temperature (76.30±0.70℃ vs. 87.70±0.30℃,Plt;0.05); while these indexes had no statistically significant differences compared to those in acellular valves group. At the same time, compared to valves in acellular valves group, valves in dye mediated photo oxidation group had more breaking strength(17.33±2.65 mPa vs. 9.11±0.95 mPa,Plt;0.05) and lower soluble protein level(0.039%±0.013% vs. 0.107%±0.024%,Plt;0.05); while these indexes had no statistically significant differences compared to those in glutaraldehyde group. Conclusion Acellular porcine aortic valve stabilized by dye mediated photo oxidation has nice biological and biomechanical characteristics.
Coronary artery diseases (CAD) have always been serious threats to human health. The measurement, constitutive modeling, and analysis of mechanical properties of the blood vessel wall can provide a tool for disease diagnosis, stent implantation, and artificial artery design. The vessel wall has both active and passive mechanical properties. The passive mechanical properties are mainly determined by elastic and collagen fibers, and the active mechanical properties are determined by the contraction of vascular smooth muscle cells (VSMC). Substantial studies have shown that, the two-layer model of the vessel wall can feature the mechanical properties well, and the circumferential, axial and radial strain and stress are of great significance in arterial wall mechanics. This study reviewed recent investigations of mechanical properties of the vessel wall. Challenges and opportunities in this area are discussed relevant to the clinical treatment of coronary artery diseases.
The effect of parasitic ions on the results of ultraviolet A (UVA) cross-linking in iontophoresis was still not clear. In this work, the porcine sclera was cross-linked by riboflavin lactate Ringer’s solution (group A) and riboflavin normal saline (group B) in vitro, respectively. The concentration of parasitic ions in the solution was calculated. In addition, the average fluorescence intensity, penetration depth and concentration after the introduction of riboflavin and the mechanical properties of cross-linked sclera tissue were measured. The ranges of diffusion coefficient of the two solutions were also calculated, respectively. The results showed that more kinds of parasitic ions were detected in group A compared with group B, while the average fluorescence intensity, penetration depth and concentration of riboflavin and scleral elastic modulus in group B were significantly higher than those in group A when the penetration time was 10 minutes. Besides, the diffusion coefficient of riboflavin in group B was about 1.5 times larger than that in group A. The results suggested that the species of parasitic ions has a great impact on the permeability of riboflavin, and affects the mechanical properties of cross-linked sclera. The above results could provide a reference for improving the efficiency of riboflavin introduction and optimizing the formula of riboflavin in iontophoresis scleral cross-linking.