west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "mesh" 44 results
  • Clinical Study of Laparoscopic Transabdominal Preperitoneal Inguinal Hernia Repair for Recurrent Inguinal Hernia after Inguinal Hernioplasty with Plug Prefix Mesh

    ObjectiveTo investigate the surgical skills and clinical effects of the laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair in treatment of recurrent inguinal hernia with plug prefix mesh. MethodsThe clinical data such as operation time, intraoperative blood loss, postoperative hospital stay, and postoperative complications of 87 patients with recurrent inguinal hernia reoperated in laparoscopic TAPP after inguinal hernioplasty with plug prefix mesh (recurrent hernia group), in the Department of Gastroenterology and Hernia surgery of the First Affiliated Hospital of Kunming Medical University from January 2011 to December 2013, were retrospectively analyzed, which were compared with the 834 incipient inguinal hernia patients operated first by TAPP (incipient hernia group) at the same time. ResultsThe operations were completed successfully in all of the 921 patients without conversion to open surgery. The operation time and intraoperative blood loss in the recurrent hernia group were significantly more than those in the incipient hernia group (P=0.000, P=0.000), the postoperative hospital stay had no signifcant difference between two groups (P=0.057). No recurrences were observed in the recurrent hernia group and incipient hernia group for following-up of (31±4) months and (28±6) months, respectively. Compared with the incipient hernia group, the rates of postoperative pain on day 30 and seroma on day 1 and 3 were higher in the recurrent hernia group (P=0.001, P=0.040, P=0.003, respectively). There were no severe complications such as collateral damage, foreign body sensation, incision infection, intestinal obstruction and so on in the two groups. ConclusionsThe laparoscopic TAPP inguinal hernia repair is safe and effective for patients with recurrent inguinal hernia with plug prefix mesh. More skills are required to reduce the complications. The operation time and intraoperative blood loss in reoperated patients with recurrent inguinal hernia are more than those in patients with incipient inguinal hernia. The rates of seroma on day 1 and 3 are also higher.

    Release date: Export PDF Favorites Scan
  • PREPARATION AND BIOMECHANICS STUDY OF BIOLOGICAL ARTIFICIAL KNEE JOINT PROSTHESIS WITH STEREO MESH SURFACE IN RABBIT

    Objective To develop a kind of biological artificial knee joint prosthesis with stereo mesh surface for rabbit, to observe its function after being implanted into rabbit knee joint and to evaluate its biomechanical property.Methods Thirty adult New Zealand rabbits were randomized into experimental and control groups (n=15), total left knee arthroplasty was performed in both groups, no patella replacement was performed. Biological artificial knee joint prosthesis with stereo mesh surface was self-designed. The adjacent 4/5 surface of femur and tibia stem of the prosthesis was covered by stainlesssteel stereo mesh, the inner surface of femur condyles and tibia plateau was welded with two layers of stainless steel stereo mesh, then the prosthesis underwent biological fixation in the experimental group. Meanwhile, prosthesis having smooth marrow internal stem, femoral condyle and tibial plateau internal surface and sharing the same shape and size with the experimental group were prepared and fixed with bone cement in the control group. The postoperative general condition of animal was observed. At 1, 3 and 6 months after operation, the rabbits were killed for gross observation, X-ray examination was conducted to observe the fixation condition of prosthesis and heal ing condition, the range of motion (ROM) of knee joints was tested, biomechanics test was carried out and the maximum shear strength of prosthesis bone interface was calculated. Results In each group, there was 1 rabbit died and new one was added during the second experiment. The others survived till the end of the experiment and crawled normally 7 days after operation. For the excellent and good rate concerning the recovery of ROM of the knee joint at 1, 3 and 6 months after operation, the experimental group was 60%, 80% and 80%, respectively, and the control group was 60%, 80% and 60%, respectively, indicating there were no significant differences between two groups (P gt; 0.05). For the experimental group, the gross observation showed large quantities of bone reconstruction, X-ray films indicated the prosthesis fitted well, with sol id fixation and without dislocation and lossening;while for the control group, the gross observation showed no bone reconstruction, X-ray films displayed the location of prosthesis was good, with sol id fixation and without dislocation and loosening. Radiolucent zone around the femur prosthesis and stress shileding occured 6 months after operation. For the maximum shear strength, the experimental group was less than the control group at 1 month after operation; and it was higher than the control group at 3 and 6 months after operation, indicating there were significant differences betweentwo groups (P lt; 0.01). Conclusion The fixation strength of the biological artificial knee joint prosthesis with stereo meshsurface is better than that of the bone cement prosthesis in rabbits at 3 and 6 months after operation.

    Release date:2016-09-01 09:05 Export PDF Favorites Scan
  • REPAIR OF MAXILLARY DEFECTS BY FREE FOREARM FLAP AND TITANIUM MESH

    Objective To investigate the clinical effect of free forearm flap and titanium mesh in repairing maxillary defects. Methods From January 2002 to November 2002,partial maxillectomy or maxillectomy wereperformed in 3 patients with maxillary gingival carcinoma, in 1 patient with palatine mucoepicermoid carcinoma and in 1 patient with maxillary sinus carcinoma. Maxillary defects were reconstructed withfree forearm flaps ranging from 4 cm×5 cm to 6 cm×7 cm and titanium mesh.The effect was estimated by clinical examination, CT and nasopharyngoscope. Results Five cases were followed up 515 months. All the flaps were alive. Facial, alveolar process and palatal contours were restored well. Epithelium was found on the nostril surface of the titanium mesh. The functions of speech and chew were restored well. Conclusion A combination of the free forearm flap and titanium mesh is an ideal method in reconstruction of maxillary defects.

    Release date:2016-09-01 09:33 Export PDF Favorites Scan
  • CLINICAL RESEARCH OF LAPAROSCOPIC BUNDLED FASTIGIATED MESH IN REPAIRING INGUINAL HERNIA

    Objective To explore the method and effectiveness of laparoscopic bundled fastigiated mesh in repairing inguinal hernia. Methods Between January 2003 and December 2009, 1 215 patients (1 363 sides) with inguinal hernia were treated. There were 1 132 males (1 268 sides) and 83 females (95 sides), aged from 18 to 89 years (median, 58 years). The cases included 1 187 cases (1 329 sides) of primary hernia and 28 cases (34 sides) of recurrent hernia. There were indirect inguinal hernia in 728 cases (786 sides), direct inguinal hernia in 416 cases (499 sides), femoral hernia in 43 cases (45 sides), and unusual hernia in 28 cases (33 sides). According to the hernia classification criteria, there were 31 cases (38 sides) in type I, 683 cases (754 sides) of type II, 403 cases (452 sides) of type III, and 98 cases (119 sides) of type IV. The disease duration was 1 to 9 days with an average of 3.8 days. To repair the hernia, the bundled fastigiated mesh was patched through the internal inguinal ring and fixed on the internal inguinal fascia by three-point fixation. The mesh would be wrapped in the peritoneum by purse-string suture. Results The surgeries were performd successfully. The operative time ranged from 18-32 minutes (mean, 22 minutes). Postoperative tractional pain in the inguinal region occurred in 19 cases (21 sides), acute uroschesis in 8 cases, and far-end hernial sac effusion in 2 cases (2 sides); all were cured after symptomatic treatment. All incisions healed by first intention, and no complications of fever, infection, or hematoma occurred. A total of 1 095 cases (1 182 sides) were followed up 1 to 7 years (median, 3 years and 9 months). Five patients died of medical illnesses at 1-3 years after operation. Three cases recurred and then were cured by a second surgery. No intestinal adhesion or obstruction occurred. Conclusion The bundled fastigiated mesh in laparoscopic inguinal hernia repair has the advantages of minimal invasiveness, easy-to-operate, less complications, and lower recurrence rate.

    Release date:2016-08-31 05:45 Export PDF Favorites Scan
  • LAPAROSCOPIC Y-SHAPED POLYPROPYLENE MESH FOR UTERINE AND VAGINAL VAULT PROLAPSE

    Objective To investigate the effectiveness of laparoscopic Y-shaped polypropylene mesh in the treatment of uterine and vaginal vault prolapse. Methods Between June 2010 and December 2012, 24 patients with uterine and vaginal vault prolapse were treated by laparoscopic pelvic reconstruction (vagina and uterus-sacral fixation) with Y-shaped polypropylene mesh. The age of patients was 35-60 years (mean, 48.6 years). The disease duration was 2-8 years (mean, 5 years). According to the pelvic organ prolapse quatitative (POP-Q) classification by International Continence Society (ICS), 16 cases were classified as uterine prolapsed degree II and 8 cases as degree III; 15 cases were classified as vaginal prolapse degree I, 7 cases as degree II, and 2 cases as degree III. All patients received postoperative follow-up regularly. Subjective evaluation was done based on prolapse quality of life questionnaire (P-QOL), and objective evaluation based on POP-Q classification. Results All the patients were operated successfully. The operation time was 22-68 minutes (mean, 33 minutes); the blood loss was 30-80 mL (mean, 51 mL); the indwelling urethral catheter remain was 3-7 days (mean, 4 days); and the hospitalization days were 4-9 days (mean, 6.8 days). Twenty-four patients were followed up 3-12 months (mean, 9 months), of whom, 2 were followed up less than 6 months. All patients had normal urination after withdrawal of urethral catheter, and the residual urine volume was in normal range. No patients had mesh erosion and discomfort during sex, vaginal and anal bearing down. The P-QOL scores at 3, 6, and 12 months after operation were significantly improved when compared with the preoperative value (P lt; 0.05); but there was no significant difference among 3, 6, and 12 months after operation (P gt; 0.05). The postoperative POP-Q classification was degree 0 in 19 cases and degree I in 3 cases, and the objective cure rate was 91.7%. No recurrence was found during follow-up. Conclusion Laparoscopic Y-shaped polypropylene mesh for treatment of uterine and vaginal vault prolapse is a safe and effective method, especially applicable to preserve the uterus, and higher requirements of sexual life of patients.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan
  • Laparoscopic mesh repair of Morgagni hernia: Two-case report

    Morgagni hernia is a rare form (accounting for 2%) of congenital diaphragmatic hernia. The traditional treatment for Morgagni hernia includes thoracotomy and laparotomy. However, surgical trauma limits its adoption. We reported the results of 2 patients with congenital Morgagni hernias in adults and described the operation methods of the patients. The 2 patients recovered uneventfully. No evidence of recurrence was found after 5 years follow-up. Laparoscopic repair for Morgagni hernia with mesh is applicable for obese, aged and bilateral Morgagni hernias patients.

    Release date:2021-07-28 10:02 Export PDF Favorites Scan
  • Vacuum sealing drainage in the treatment of mesh infection following inguinal hernia repair

    Objective To observe the clinical effect of vacuum sealing drainage (VSD) in the treatment of mesh infection following inguinal hernia repair. Methods A total of 24 patients who suffered form mesh infection following inguinal hernia repair and got treatment in our hospital from February 2012 to December 2015 were collected and divided into 2 groups according to the type of treatment, 12 patients (13 sides) of VSD group received treatment of VSD, and 12 patients (13 sides) of conventional group received conventional treatment. Comparison between the 2 groups in mesh retention rate, the wound healing time, hospitalization cost, and hospital stay was performed. Results There was significant difference in mesh retention rate〔76.9% (10/13)vs. 30.8% (4/13)〕, the wound healing time〔(20.5±4.4) dvs. (29.7± 6.7) d〕, hospitalization cost〔(18 430.1±7 180.2) RMBvs. (12 201.1±6 453.2) RMB〕, and hospital stay〔(23.5±4.1) dvs. (30.7±6.5) d〕between the VSD group and conventional group (P<0.050). Compared with conventional group, the mesh retention rate and hospitalization cost were higher, the wound healing time and hospital stay were shorter in VSD group. Conclusions VSD can effectively control the mesh infection following hernia repair, improve the mesh retention rate. The VSD can also promote growth of granulation tissue in cavity, shorten the wound healing time and hospital stay, but has a high hospitalization cost than conventional treatment.

    Release date:2017-04-01 08:56 Export PDF Favorites Scan
  • STUDY ON BIOLOGICAL FIXATION OF FEMORAL STEM PROSTHESIS WITH MULTILAYER MACROPORES COATING BY COMBINED USE OF AUTOGENOUS BONE GRAFTING

    Objective To observe the effect of biological fixation of femoral stem prosthesis with multilayer macropores coating by combined use of autologousbone grafting. Methods The reconstructing femoral stem prostheses were designed personally, proximal 2/3 surfaces of which were reformed by thick multilayer stereo pore structure. Twentyfour adult mongrel canines underwent right femoralhead replacement and were divided randomly into two groups. The autogenous bonemud of femoral head and neck were not used in the control group. The histologicexamination, roentgenograms and biomechanical test were carried out in the 1st,3rd and 6th month after operation to observe the bone formation and fixation inthe exterior and interior sides of the prostheses. Results Onthe whole view,bone reconstruction occurred in experimental group in the 3rd and 6th month. Roentgenograms also proved to be superior to the control group. Histological examinationshowed that both the maximum bone inserting depth(μm) and average engorging ratio(%) of newly formed bone in experimental group surpassed those in the control group. The maximum shear strength of prosthesisbone interface in experimental group was significantly higher than that in the control group(Plt;0.01). Conclusion Intensity of biological fixation can be strengthened remarkably by using femoral stem prothesis with multilayer macropores coating by combined use of autologous bone grafting.

    Release date:2016-09-01 09:28 Export PDF Favorites Scan
  • BIOMECHANICAL EVALUATION OF TITANIUM MESH WITH ANTERIOR PLATE FIXATION OR ILIUM AUTOGRAFT IN ANTERIOR CERVICAL DECOMPRESSIONZHAO

    Objective To evaluate the biomechanical characteristicsof titanium mesh with anterior plate fixation or ilium autograft in anterior cervical decompression.Methods Six fresh cervical spine specimens(C3-7) of young cadaver were used in the biomechanical test. After C5, C5,6 and C4-6 were given vertebrectomy,ilium autograft and titanium mesh with anterior plate fixation were performed. Their stabilities of flexion,bilateral axial rotation,the lateral bending and the extension were tested. Intact cervical spine specimens served as control group. Results Ilium autograft improved the stability of the unstable cervical vertebrae and decreased the flexion, the lateral bending or the extension, showing a significant difference when compared with control group(Plt;0.05). Whereas, axial rotational motion was decreased insignificantly(Pgt;0.05). Titanium meshwith anterior plate fixation improved the stability of the unstable spine and decreased the flexion,the bilateral axial rotation,the lateral bending or the extension, showing a significant difference when compared with control group(Plt;0.05). Conclusion The vertebrectomy and anterior cervical fusion by ilium autograft was the least stable construct of all modes tested,and the titanium mesh implantation is stabler than the intact cervical sample.

    Release date:2016-09-01 09:24 Export PDF Favorites Scan
  • EFFECTIVENESS OF PREPERITONEAL HERNIORRHAPHY WITH Ultrapro Plug MESH FOR UMBILICAL HERNIA REPAIR IN ADULTS

    Objective To explore the effectiveness of preperitoneal herniorrhaphy with Ultrapro Plug (UPP) mesh for umbilical hernia repair in adults. Methods Between September 2011 and June 2015, 71 patients with umbilical hernia underwent preperitoneal herniorrhaphy with UPP mesh. There were 26 males and 45 females, aged 19-92 years (mean, 54.3 years). The disease duration was 45 days to 30 years (median, 18 months). Umbilical hernia was diagnosed through physical examination, ultrasound, and other relevant auxiliary examination. According to American Society of Anesthesiologists (ASA) classification, 12 cases were rated as grade Ⅰ, 34 cases as grade Ⅱ, 21 cases as grade Ⅲ, and 4 cases as grade Ⅳ. The operation time, postoperative hospitalization time, complication, and recurrence were recorded. Results The diameter of hernia ring ranged 0.5-3.0 cm (mean, 1.8 cm). There was no vessel or intestine injury. The operation time was 12-35 minutes (mean, 22.4 minutes); postoperative hospitalization time was 12-48 hours (mean, 16.3 hours). Fat liquefaction of incision occurred in 2 cases, and primary healing of incision was obtained in the other cases. Sixty-nine patients were followed up 8-51 months (median, 28 months). Hernia recurrence and patch infection occurred in 1 case respectively during follow-up. No postoperative foreign body sensation and chronic pain occurred. Conclusion Repairing umbilical hernia in adults with UPP mesh should be safe and reliable, because it has the advantages of short operation time, short hospital stay, less complication, and lower incidence of recurrence.

    Release date: Export PDF Favorites Scan
5 pages Previous 1 2 3 4 5 Next

Format

Content