ObjectiveTo systematically evaluate the efficacy of different interventions in preventing rocuroniuminduced injection pain or withdrawal movements, so as to provide references for preventing adverse reactions induced by rocuronium injection in clinical practice. MethodsWe electronically searched PubMed, EMbase, The Cochrane Library (Issue 3, 2014), CBM, and CNKI databases to collect randomized controlled trials (RCTs) about the prevention of rocuronium-induced injection pain or withdrawal movements from inception to March 2014. Two reviewers independently screened literature, extracted data, and assessed the risk of bias of included studies. Then, meta-analysis was performed using RevMan 5.2.8 software. ResultsA total of 43 RCTs involving 6 034 patients were include. The results of meta-analysis showed that compared with the placebo/blank group, lidocaine pretreatment with venous occlusion (RR=0.37, 95%CI 0.29 to 0.48, P<0.000 01), opioid drug pretreatment with venous occlusion (RR=0.77, 95%CI 0.68 to 0.87, P<0.000 1), lidocaine pretreatment with venous injection (RR=0.51, 95%CI 0.44 to 0.59, P<0.000 01), opioid drug pretreatment with venous injection (OR=0.03, 95%CI 0.02 to 0.05, P<0.000 01), ketamine pretreatment with venous injection (RR=0.36, 95%CI 0.23 to 0.54, P<0.000 01), mixing sodium bicarbonate (NaHCO3) with rocuronium (OR=0.02, 95%CI 0.01 to 0.04, P<0.000 01) and local heating (RR=0.74, 95%CI 0.63 to 0.88, P=0.000 6) were all effective in decreasing the incidence of rocuronium-induced injection pain or withdrawal movements. ConclusionThe intravenous injection of opioid drugs was effective in preventing rocuronium-induced injection pain or withdrawal movements, while local heating needs further research. Due to the limited quantity and quality of the induced studies, the above conclusion still needs to be verified by more high quality studies.
Objective To verify the effect of palatoplasty with or without velopharyngeal muscular reconstruction on the velar movement through the lateral radiography. Methods From October 1988 to October 2000, 62 patients with cleft palate and velopharyngeal insufficiency were treated. Of them, 32 were repaired by velopharyngeal muscular reconstruction (group A) and 30 by modified von Langenbeck’s procedure (group B). The lateral radiographs and cephalometric analysis were taken. The velopharyngeal closure, velar extensibility, the angle changes of velar elevation, the distance changes of velar levator eminence based on anatomy (LEA) to velopharyngeal closure line (VCL), the varieties in LEA, the comparison of LEA and velar levator eminence based on phonation (LEP), the distance comparison between posterior nasal spine (PNS) to LEA and LEP through soft palate line (SPL) were measured. Results During the phonation, group A was significantly greater than group B in the velopharyngeal closure rate(Plt;0.01), the velar extensibility(Plt;0.05) and the location comparison between LEA and LEP(Plt;0.01); group B was significantly greater than group A in velar elevation angle (Plt;0.05), the varieties in LEA(Plt;0.05). In velar rest position, the distance of LEA to VCL was greater inB group than in A group(Plt;0.01). There was significant difference in thedistance comparison between LEA and LEP(Plt;0.05), difference between LEA and LEP(Plt;0.01) and the distance PNS-SPL-LEA and PNSSPL-LEP(Plt;0.05) within group B; contrary to the results within group A(P>0.05). Conclusion The velopharyngeal muscular reconstruction in palatoplasty can result in a near normalizationof anatomic measurement of velar levator muscles and improve the velar functionand velopharyngeal competence. Repositioning of velar muscles in a more anatomic correct, transverse position is more important to improve the velar length andaccordant velar movement with velopharyngeal muscles in functional palatoplasty. The velar angle change and velar elevation during phonation are not determinative factors for velopharyngeal competence.
Objective To observe the effect of epidermal growth factor (EGF) on integrin alpha;5 expression and its influence on human retinal pigment epithelium (RPE) cells.Methods Human RPE cells were treated in vitro with 0.1,1.0,10.0,20.0 and 100.0 ng/ml of EGF, the mRNA and protein of integrin alpha;5 was measured by reverse transcription polymerase chain reaction(RT-PCR)and flow cytometry. Human RPE cells were cultured under 4 conditions including DMEM/F12,DMEM/F12+10 ng/ml EGF, DMEM/F12+10 ng/ml EGF+rabbit antihuman integrin alpha;5 antibody (1∶100),DMEM/F12+10 ng/ml EGF+rabbit antihuman vimentin antibody (1∶100), and their proliferation and migration were measured by methylthiazole tetrazolium(MTT)and Boyden chamber.Results The integrin alpha;5 mRNA level of human RPE cells was not changed after 12 hours of EGF stimulation (F=0.618, P=0.687), however it was induced in a dosedependent manner after 24 and 48 hours of EGF stimulation (F=465.303, 212.340; P=0.000,0.000).The protein level of integrinalpha;5 was higher in 10 ng/ml EGF stimulation compared with the control group and 0.1 ng/ml group(P<0.01).MTT and Boyden chamber showed that the integrin alpha;5 expression increased the proliferation and migration of human RPE cells. Conclusion EGF can induce integrin alpha;5 expression,thus increase the proliferation and migration of human RPE cells.
The surgical installation accuracy of the components in unicompartmental knee arthroplasty (UKA) is an important factor affecting the joint function and the implant life. Taking the ratio of the medial-lateral position of the femoral component relative to the tibial insert (a/A) as a parameter, and considering nine installation conditions of the femoral component, this study established the musculoskeletal multibody dynamics models of UKA to simulate the patients’ walking gait, and investigated the influences of the medial-lateral installation positions of the femoral component in UKA on the contact force, joint motion and ligament force of the knee joint. The results showed that, with the increase of a/A ratio, the medial contact force of the UKA implant was decreased and the lateral contact force of the cartilage was increased; the varus rotation, external rotation and posterior translation of the knee joint were increased; and the anterior cruciate ligament force, posterior cruciate ligament force and medial collateral ligament force were decreased. The medial-lateral installation positions of the femoral component in UKA had little effect on knee flexion-extension movement and lateral collateral ligament force. When the a/A ratio was less than or equalled to 0.375, the femoral component collided with the tibia. In order to prevent the overload on the medial implant and lateral cartilage, the excessive ligament force, and the collision between the femoral component and the tibia, it is suggested that the a/A ratio should be controlled within the range of 0.427−0.688 when the femoral component is installed in UKA. This study provides a reference for the accurate installation of the femoral component in UKA.
ObjectiveTo review the current status and progress of locking plate for the treatment of distal femoral comminuted fractures.MethodsThe related literature was extensively reviewed to summarize the current status and progress in the treatment of distal femoral comminuted fracture with locking plate from four aspects: the current treatment situation, the shortcomings of locking plate and countermeasures, the progress of locking technology, locking plate and digital orthopedic technology.ResultsTreatment of distal femoral comminuted fractures is challenging. Locking plates, the most commonly used fixation for distal femoral comminuted fractures, still face a high rate of treatment failure. Double plates can improve the mechanical stability of comminuted fractures, but specific quantitative criteria are still lacking for when to choose double plates for fixation. The far cortial locking screw has shown good application value in improving the micro-movement and promoting the growth of callus. The biphasic plating is a development of the traditional locking plate, but needs further clinical examination. As an auxiliary means, digital orthopedic technology shows a good application prospect.ConclusionThe inherent defect of locking plate is a factor that affects the prognosis of distal femoral comminuted fracture. The optimization of locking technology combined with digital orthopedic technology is expected to reduce the failure rate of treatment of distal femoral comminuted fracture.
ObjectiveTo explore the nature of micromovement and the biomechanical staging of fracture healing.MethodsThrough literature review and theoretical analysis, the difference in micromovement research was taken as the breakthrough point to try to provide a new understanding of the role of micromovement and the mechanical working mode in the process of fracture healing.ResultsThe process of fracture healing is the process of callus generation and connection. The micromovement is the key to start the growth of callus, and the total amount of callus should be matched with the size of the fracture space. The strain at the fracture end is the key to determine the callus connection. The strain that can be tolerated by different tissues in the fracture healing process will limit the micromovement. According to this, the fracture healing process can be divided into the initiation period, perfusion period, contradiction period, connection period, and physiological period, i.e., the biomechanical staging of fracture healing.ConclusionBiomechanical staging of fracture healing incorporates important mechanical parameters affecting fracture healing and introduces the concepts of time and space, which helps to understand the role of biomechanics, and its significance needs further clinical test and exploration.
Functional electronic stimulation (FES) may provide a means to restore motor function in patients with spinal cord injuries. The goal of this study is to determine the regions in the spinal cord controlling different hindlimb movements in the rats. Normalization was used for the regions dominating the corresponding movements. It has been verified that FES can be used in motor function recovery of the hindlimb. The spinal cord was stimulated by FES with a three-dimensional scan mode in experiments. The results show that stimulation through the electrodes implanted in the ventral locations of the lumbosacral enlargement can produce coordinated single- and multi-joint hindlimb movements. A variety of different hindlimb movements can be induced with the appropriate stimulation sites, and movement vectors of the hindlimb cover the full range of movement directions in the sagittal plane of the hindlimb. This article drew a map about spinal cord motor function of the rat. The regions in the spinal cord which control corresponding movements are normalized. The data in the study provide guidance about the location of electrode tips in the follow-up experiments.
Aiming at the limitations of clinical diagnosis of Parkinson’s disease (PD) with rapid eye movement sleep behavior disorder (RBD), in order to improve the accuracy of diagnosis, an intelligent-aided diagnosis method based on few-channel electroencephalogram (EEG) and time-frequency deep network is proposed for PD with RBD. Firstly, in order to improve the speed of the operation and robustness of the algorithm, the 6-channel scalp EEG of each subject were segmented with the same time-window. Secondly, the model of time-frequency deep network was constructed and trained with time-window EEG data to obtain the segmentation-based classification result. Finally, the output of time-frequency deep network was postprocessed to obtain the subject-based diagnosis result. Polysomnography (PSG) of 60 patients, including 30 idiopathic PD and 30 PD with RBD, were collected by Nanjing Brain Hospital Affiliated to Nanjing Medical University and the doctor’s detection results of PSG were taken as the gold standard in our study. The accuracy of the segmentation-based classification was 0.902 4 in the validation set. The accuracy of the subject-based classification was 0.933 3 in the test set. Compared with the RBD screening questionnaire (RBDSQ), the novel approach has clinical application value.
Existing emotion recognition research is typically limited to static laboratory settings and has not fully handle the changes in emotional states in dynamic scenarios. To address this problem, this paper proposes a method for dynamic continuous emotion recognition based on electroencephalography (EEG) and eye movement signals. Firstly, an experimental paradigm was designed to cover six dynamic emotion transition scenarios including happy to calm, calm to happy, sad to calm, calm to sad, nervous to calm, and calm to nervous. EEG and eye movement data were collected simultaneously from 20 subjects to fill the gap in current multimodal dynamic continuous emotion datasets. In the valence-arousal two-dimensional space, emotion ratings for stimulus videos were performed every five seconds on a scale of 1 to 9, and dynamic continuous emotion labels were normalized. Subsequently, frequency band features were extracted from the preprocessed EEG and eye movement data. A cascade feature fusion approach was used to effectively combine EEG and eye movement features, generating an information-rich multimodal feature vector. This feature vector was input into four regression models including support vector regression with radial basis function kernel, decision tree, random forest, and K-nearest neighbors, to develop the dynamic continuous emotion recognition model. The results showed that the proposed method achieved the lowest mean square error for valence and arousal across the six dynamic continuous emotions. This approach can accurately recognize various emotion transitions in dynamic situations, offering higher accuracy and robustness compared to using either EEG or eye movement signals alone, making it well-suited for practical applications.
Robot rehabilitation has been a primary therapy method for the urgent rehabilitation demands of paralyzed patients after a stroke. The parameters in rehabilitation training such as the range of the training, which should be adjustable according to each participant’s functional ability, are the key factors influencing the effectiveness of rehabilitation therapy. Therapists design rehabilitation projects based on the semiquantitative functional assessment scales and their experience. But these therapies based on therapists’ experience cannot be implemented in robot rehabilitation therapy. This paper modeled the global human-robot by Simulink in order to analyze the relationship between the parameters in robot rehabilitation therapy and the patients’ movement functional abilities. We compared the shoulder and elbow angles calculated by simulation with the angles recorded by motion capture system while the healthy subjects completed the simulated action. Results showed there was a remarkable correlation between the simulation data and the experiment data, which verified the validity of the human-robot global Simulink model. Besides, the relationship between the circle radius in the drawing tasks in robot rehabilitation training and the active movement degrees of shoulder as well as elbow was also matched by a linear, which also had a remarkable fitting coefficient. The matched linear can be a quantitative reference for the robot rehabilitation training parameters.