find Keyword "pelvic" 65 results
  • Application of retrievable vena cava filter in patients with lower limb fractures complicated with deep venous thrombosis

    ObjectiveTo explore the value of recombinant inferior vena cava filter (IVCF) in the prevention of perioperative pulmonary embolism in patients with lower limb or pelvic fracture combined with deep venous thrombosis (DVT).MethodsThe clinical data of 168 patients with lower limb or pelvic fracture combined with DVT were analyzed retrospectively.ResultsThe filters were successfully implanted in 168 patients, and the recoverable filters were removed after (48.3±4.8) d (14–97 d). The filters were removed successfully in 159 cases, and the removal rate was 94.6%. Sixty-one cases were found to have thrombus on the filter after contrast examination or removal of vena cava filter, that is, the thrombus interception rate was 36.3%.ConclusionFor patients with lower limb or pelvic fracture combined with DVT, the rechargeable vena cava filter can effectively stop thrombosis and avoid pulmonary embolism.

    Release date:2019-03-18 05:29 Export PDF Favorites Scan
  • Treatment of unstable pelvic fractures by cannulated screw internal fixation with the assistance of three-dimensional printing insertion template

    ObjectiveTo evaluate the effectiveness of unstable pelvic fractures treated by cannulated screw internal fixation with the assistance of three-dimensional (3D) printing insertion template.MethodsThe clinical data of 10 patients who underwent surgical treatment for unstable pelvic fractures by cannulated screw internal fixation with the assistance of 3D printing insertion template between May 2015 and June 2016 were retrospectively analysed. There were 7 males and 3 females with an average age of 37.5 years (range, 20-58 years). The causes of injury included falling from height in 5 cases, crushing from heavy load in 1 case, and traffic accidents in 4 cases. The interval from injury to admission was 1-5 hours (mean, 3.1 hours). The fracture situation included 6 cases of sacral fracture, 1 case of right sacroiliac joint dislocation, and 3 cases of iliac bone fracture. There were 10 cases of superior and inferior pubic rami fracture, including 3 cases on the left side (2 cases of suprapubic fracture adjacent to symphysis pubis), 2 cases on the right side, and 5 cases on the bilateral. All fractures were classified according to the Tile system, there were 4 cases of type B2, 1 of type B3, 4 of type C1, and 1 of type C2. The radiological outcome was evaluated by Matta scale, and the positions of the iliosacral screw and superior pubic ramus screw were evaluated according to 3D reconstruction of CT postoperatively. The functional outcome was evaluated by Majeed function scale.ResultsThe average time of each screw implantation was 30 minutes, and the average blood loss per screw incision was 50 mL. The time of implantation of each sacroiliac screw was 24-96 seconds (mean, 62 seconds), and the time of implantation of each suprapubic screw was 42-80 seconds (mean, 63.2 seconds). The hospitalization duration was 17-90 days (mean, 43.7 days). All incisions healed by first intention. All patients were followed up 12-22 months (mean, 15.6 months). The radiological outcome was excellent in 8 cases and good in 2 cases according to Matta scale; and 3D reconstruction of CT demonstrated that all the 9 iliosacral screws were placed as type Ⅰ, and all the 13 suprapubic ramus screws were placed as grade 0 on the first postoperative day. No complication such as neurovascular injury, screw back out or rupture, or secondary fracture displacement was observed during the follow-up. At 6 months after operation, the X-ray films showed good fracture healing in all the 10 patients. The functional outcome was excellent in 9 cases and good in 1 case according to Majeed scale at 1 year after operation. One patient sustained Tile C2 pelvic disruption complicated with L5 nerve root injury achieved complete nervous functional recovery at last follow-up.ConclusionIt has advantages of precise screw insertion and lower risk of neurovascular injury to treat unstable pelvic fractures by cannulated screw internal fixation with the assistance of 3D printing insertion template, which can be a good alternative for the treatment of unstable pelvic fractures.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • Effectiveness analysis of 5G remote robotic surgery in pelvic fracture treatment

    Objective To investigate the effectiveness of 5G remote robotic surgery in the treatment of pelvic fractures. Methods A retrospective analysis was conducted on the clinical data of 160 patients with pelvic fractures admitted between July 2023 and June 2024 who met the selection criteria. Among these patients, 80 underwent internal fixation surgery with the assistance of 5G remote robotic surgery (5G group), while 80 received local robotic surgical assistance (control group). Baseline characteristics, including gender, age, body mass index, disease duration, cause of injury, and fracture classification, were compared between the two groups, and no significant difference was found (P>0.05). The incision length, operation time, intraoperative blood loss, hospital stay, accuracy of screw placement, maximum residual displacement postoperatively, quality of fracture reduction, incidence of complications, Majeed pelvic function score and classification at last follow-up were recorded and compared between the two groups. Results In the 5G group, 180 screws were implanted during surgery, while 213 screws were implanted in the control group. The 5G group demonstrated significantly reduced intraoperative blood loss and shorter incision length compared to the control group (P<0.05). No significant difference was observed between the two groups in terms of operation time or hospital stay (P>0.05). Radiographic evaluation revealed excellent and good reduction rates of 98.8% (79/80) in the 5G group and 97.5% (78/80) in the control group, while excellent and good screw placement accuracy rates were 98.3% (177/180) in the 5G group and 95.8% (204/213) in the control group. No significant difference was found between the two groups in maximum residual displacement, reduction quality, or screw placement accuracy (P>0.05). All patients were followed up 7-16 months (mean, 11.3 months), with no significant difference in follow-up duration between the groups (P>0.05). No perioperative or follow-up complication, such as wound infection, iatrogenic fractures, iatrogenic neurovascular injury, screw loosening or breakage, or nonunion, were observed in either group. The control group exhibited a worse degree of gait alteration compared to the 5G group (P<0.05), while no significant difference was found in incidences of squatting limitation or persistent pain (P>0.05). At last follow-up, no significant difference was observed between the groups in Majeed pelvic function scores or grading (P>0.05). Conclusion Compared with the local surgery group, 5G remote robotic surgery supported by remote expert technical guidance demonstrated smaller incision lengths, less intraoperative blood loss, and fewer postoperative complications, and was shown to be a precise, minimally invasive, safe, and reliable surgical method.

    Release date: Export PDF Favorites Scan
  • Treatment of Day type Ⅱ pelvic crescent fracture by using percutaneous cannulated screw fixation technique

    ObjectiveTo evaluate the feasibility and effectiveness of percutaneous cannulated screw fixation for the treatment of Day type Ⅱ pelvic crescent fracture.MethodsThe clinical data of 14 patients with Day type Ⅱ pelvic crescent fractures underwent closed reduction and percutaneous cannulated screw fixation between January 2009 and July 2016 were retrospectively analysed. There were 9 males and 5 females, aged 17-65 years (mean, 38 years). The causes of injury included traffic accident in 8 cases, falling from height in 3 cases, bruise injury in 3 cases; all were closed fractures. According to Tile classification, there were 8 cases of type B, 6 cases of type C. There were 13 cases combined with fracture of the anterior pelvic ring, including 8 cases of superior and inferior ramus of pubis fracture, 1 case of superior ramus of pubis fracture with symphysis separation, and 4 cases of symphysis separation. The interval of injury and admission was 1- 72 hours (mean, 16 hours), and the interval of injury and operation was 3-8 days (mean, 5 days). After operation, the reduction of fracture was evaluated by the Matta evaluation criteria, the clinical function was assessed by Majeed function assessment.ResultsThe operation time was 35-95 minutes (mean, 55 minutes), cumulative C-arm fluoroscopy time was 3-8 minutes (mean, 5 minutes), no iatrogenic vascular injury and pelvic organ damage occurred. Postoperative X-ray films at 2 days indicated that 2 cases of vertical shift and 2 cases of mild rotation were not completely corrected. Postoperative CT examination at 3 days indicated that 2 pubic joint screws broke through the obturator bone cortex. None of the pubic ramus screws entered into the acetabulum, but a screw of superior pubic branch broke through the posterior cortical of superior pubic branch, a screw of posterior ilium column broke through the medial bone cortex of the ilium, and no clinical symptom was observed. One patient suffered from wound infection in the pubic symphysis, then healed after 2 weeks of wound drainage, the other wounds healed by first intention. According to Matta criterion for fracture reduction, the results were excellent in 9 cases, good in 4 cases, and fair in 1 case with an excellent and good rate of 92.9%. All patients were followed up 8-24 months (mean, 14 months). All fractures healed at 4 months and restored to the normal walking at 6 months after operation, 3 patients suffered from slight pain in the sacroiliac joints and slight claudication when they were tired or walked for a long time and unnecessary for special treatment. One patient felt pain in the back of the iliac spine when he was lying down. During the follow-up, no screw loosening or other internal fixation failure occurred. At last follow-up, according to Majeed functional evaluation criteria, the results were excellent in 7 cases, good in 5 cases, and fair in 2 cases with an excellent and good rate of 85.7%.ConclusionThe percutaneous cannulated screw fixation is a safe treatment for Day type Ⅱ pelvic crescent fracture, which has a reliable fixation and good effectiveness.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • Application effect evaluation of reverse digital modeling combined with three-dimensional printed disease models in standardized clinical training and teaching of pelvic tumor

    Objective To evaluated the application effect of reverse digital modeling combined with three-dimensional (3D)-printed disease models in the standardized training of orthopedic residents focusing on pelvic tumors. Methods From August 2022 to August 2023, 60 orthopedic residents from West China Hospital, Sichuan University were randomly assigned to a trial group (n=30) and a control group (n=30). The trial group received instruction using reverse digital modeling and 3D-printed pelvic tumor models, while the control group underwent traditional teaching methods. Teaching outcomes were evaluated and compared between groups through knowledge tests, practical skill assessments, and satisfaction surveys. Results Before training, there was no statistically significant difference in knowledge tests or practical skill assessments between the two groups (P>0.05). After training, the trial group showed significantly better performance than the control group in knowledge tests (90.5±5.2 vs. 78.4±6.8, P<0.05), skill assessments (92.7±4.9 vs. 81.3±6.2, P<0.05), and satisfaction surveys (9.40±1.10 vs. 7.60±1.20, P<0.05). One month after training, the trial group still showed significantly better performance than the control group in knowledge tests (88.1±6.4 vs. 72.3±7.1, P<0.05) and skill assessments (90.3±5.8 vs. 75.6±6.9, P<0.05). Conclusions Reverse digital modeling combined with 3D printing offers an intuitive and effective teaching approach that improves comprehension of pelvic tumor anatomy and strengthens clinical and technical competencies. This method significantly enhances learning outcomes in standardized residency training and holds promise for broader integration into medical education.

    Release date:2025-05-26 04:29 Export PDF Favorites Scan
  • Evaluation of closed multi-axial screws iliosacral fixation system combined with posterior segmental spinal fixation for treatment of unstable sacral fractures

    Objective To evaluate the effectiveness of lumbopelvic fixation using the combination of closed multi-axial screws (CMAS) iliosacral fixation system and the posterior segmental spinal fixation for unstable sacral fractures. Methods Between January 2013 and November 2014, 25 patients (39 sides) with unstable sacral fractures were treated with lumbopelvic fixation using the combination of CMAS iliosacral fixation system and the posterior segmental spinal fixation. There were 17 males and 8 females, aged 19-55 years (mean, 33.9 years). The causes were traffic accident injury in 15 cases, falling injury from height in 8 cases, and crushing injury in 2 cases. The interval of injury and operation was 1-13 days (mean, 3.5 days). Fracture was classified as Denis type I in 2 sides, type II in 20 sides, and type III in 17 sides; nerve injury was rated as Gibbons grade I in 2 cases, grade II in 2 cases, grade III in 7 cases, and grade IV in 9 cases. The reduction quality was evaluated by Matta criterion, the clinical function outcome by Majeed, and nerve function by Gibbons criterion. Results The average operation time was 110 minutes (range, 80-150 minutes). The average blood loss was 570 mL (range, 250-1 400 mL). Superficial wound infection occurred in 2 patients, and was cured after debridement and antibiotic therapy. All patients were followed up for an average of 18 months (range, 15-22 months). Postoperative X-ray and CT examination showed clinical healing of sacral fractures at 8-12 weeks after operation (mean, 10 weeks). The mean removal time of internal fixation was 13 months (range, 12-20 months). No screw loosening and fracture, adhesion of internal fixation to surrounding tissue, and obvious electrolysis phenomenon occurred. According to Matta criterion, reduction was rated as excellent in 32 sides, good in 6 sides, fair in 1 side, and the excellent and good rate was 97.5%. According to Majeed functional scoring at last follow-up, the mean score was 84.7 (range, 64-98); the results were excellent in 18 cases, good in 5 cases, and fair in 2 cases, and the excellent and good rate was 92.0%. The nerve function was significantly improved when compared with preoperative one; nerve injury was rated as Gibbons grade I in 8 cases, grade II in 8 cases, grade III in 3 cases, and grade IV in 1 case. Conclusion Lumbopelvic fixation using the combination of CMAS iliosacral fixation system and the posterior segmental spinal fixation is a relatively effective fixation for unstable sacral fractures. Not only is the fracture fixation rigid for early full weight-bearing, but also nerve decompression can be performed which facilitates nerve function recovery.

    Release date:2017-04-01 08:56 Export PDF Favorites Scan
  • RECONSTRUCTION OF THE PELVIE FLOOR AFTER EXCISION OF HUGE SACROCOCCYGEAL TERATOMAS

    A retrospective study of 65 cases of huge sacrococcygcal teratomas were surveyed. The long term functional prospect of the benign tumor was excellent. The characteristics of the normal and pathological anatomy of the pelvic floor were mentioncd. Based on these, the authors described some personal experiences of the procedures, and discussed some problems of the reconstruction of the pelvic floor.

    Release date:2016-09-01 11:38 Export PDF Favorites Scan
  • Surgical technique and effectiveness of titanium elastic nail assisted retrograde channel screw implantation in superior pubic branch

    Objective To investigate the surgical technique and effectiveness of titanium elastic nail (TEN) assisted retrograde channel screw implantation of superior pubic branch. Methods The clinical data of 31 patients with pelvic or acetabular fractures treated with retrograde channel screw implantation in superior pubic branch between January 2021 and April 2022 were retrospectively analyzed. Among them, 16 cases were implanted with assistance of TEN (study group) and 15 cases were implanted under the guidance of C-arm X-ray machine (control group). There was no significant difference in gender, age, cause of injury, Tile classification of pelvic fracture, Judet-Letournal classification of acetabular fracture, and time from injury to operation between the two groups (P>0.05). The operation time, fluoroscopy times, and intraoperative blood loss of each superior pubic branch retrograde channel screw were recorded during operation. X-ray films and three-dimensional CT were reexamined after operation, the quality of fracture reduction was evaluated by Matta score standard, and the position of channel screw was evaluated by screw position classification standard. The fracture healing time was recorded during the follow-up, and the postoperative functional recovery was evaluated by Merle D’Aubigne Postel score system at last follow-up. Results Nineteen and 20 retrograde channel screws of superior pubic branch were implanted in the study group and the control group, respectively. The operation time, fluoroscopy times, and intraoperative blood loss of each screw in the study group were significantly less than those in the control group (P<0.05). According to the postoperative X-ray films and three-dimensional CT, none of the 19 screws in the study group penetrated out of the cortical bone or into the joint, and the excellent and good rate was 100% (19/19); in the control group, there were 4 screws of cortical bone penetration, and the excellent and good rate was 80% (16/20); the difference between the two groups was significant (P<0.05). Matta score standard was used to evaluate the quality of fracture reduction, there was no patient in the two groups with poor reduction results, and the difference was not significant between the two groups (P>0.05). The incisions of the two groups healed by first intention, and there was no complication such as incision infection, skin margin necrosis, and deep infection. All patients were followed up 8-22 months, with an average of 14.7 months. There was no significant difference in healing time between the two groups (P>0.05). At last follow-up, the difference in functional recovery evaluated by the Merle D’Aubigne Postel scoring system between the two groups was not significant (P>0.05). Conclusion TEN assisted implantation technique can significantly shorten the operation time of retrograde channel screw implantation of superior pubic branch, reduce the times of fluoroscopy, and have less intraoperative blood loss and accurate screw implantation, which provides a new safe and reliable method for minimally invasive treatment of pelvic and acetabular fractures.

    Release date:2023-04-11 09:43 Export PDF Favorites Scan
  • Interpretation of “European Society for Vascular Surgery (ESVS) 2022 Clinical Practice Guidelines on the Management of Chronic Venous Disease of the Lower Limbs”

    On January 11, 2022, the European Society of Vascular Surgery (ESVS) completed its first update in the “European Society for Vascular Surgery 2022 Clinical Practice Guidelines on the Management of Chronic Venous Disease of the Lower Limbs” since 2015. Based on the existing literatures and expert consensus, the guidelines added and revised the treatment strategies, postoperative monitoring, and postoperative anticoagulation of superficial venous insufficiency of the lower extremities and pelvic venous diseases. The new and modified parts will be interpreted.

    Release date:2022-04-13 08:53 Export PDF Favorites Scan
  • Anterior subcutaneous internal fixation combined with posterior percutaneous iliosacral screw for treatment of unstable pelvic fractures

    ObjectiveTo assess the effectiveness of anterior subcutaneous internal fixation (INFIX) combined with posterior percutaneous iliosacral screw for the treatment of unstable pelvic fractures.MethodsBetween August 2016 and November 2017, 19 cases of unstable pelvic fractures were treated with anterior subcutaneous INFIX combined with posterior percutaneous iliosacral screw. There were 14 males and 5 females, with an average age of 40.6 years (range, 17-69 years). Causes of injury included traffic accident injury in 11 cases, falling from height in 5 cases, bruise injury by heavy object in 3 cases. According to Tile classification, there were 2 cases of type B1, 6 cases of type B2, and 11 cases of type C. Anterior ring injuries included bilateral pubic ischial ramus fractures in 12 cases, unilateral pubic ischial ramus fractures in 5 cases, and symphysis pubis separation in 2 cases. Posterior ring injuries included sacroiliac ligament injuries in 2 cases, unilateral iliac bone fractures in 3 cases, unilateral sacral fractures in 11 cases, unilateral sacroiliac joint dislocation in 2 cases, and bilateral sacral fracture in 1 case. The intraoperative blood loss and operation time were recorded, and the fracture healing and postoperative complications were observed. Matta score was used to evaluate the reduction of fracture, and Majeed score was used to evaluate the postoperative function of patients.ResultsThe operation time was 47-123 minutes (mean, 61.4 minutes) and the intraoperative blood loss was 50-115 mL (mean, 61.1 mL). One case had superficial infection at the site of screw implantation, and 1 case had unilateral cutaneous nerve stimulation, which were cured after corresponding treatment. There was no damage of urinary system, reproductive system, and intestine. All cases were followed up 12-25 months (mean, 18.1 months). All the fractures healed after operation, the average healing time was 9.5 weeks (range, 8-13 weeks); no nonunion, delayed healing, internal fixation loosening, fracture, and other situations occurred. Of the 2 patients with lumbosacral plexus injury before operation, 1 recovered completely and 1 had residual mild claudication. At last follow-up, the reduction of fracture was evaluated by Matta scoring standard, the results were excellent in 13 cases and good in 6 cases, with an excellent and good rate of 100%; the function was evaluated by Majeed scoring standard, the results were excellent in 15 cases and good in 4 cases, with an excellent and good rate of 100%.ConclusionMinimally invasive pelvic stabilization by using anterior subcutaneous INFIX and posterior percutaneous iliosacral screw for treatment of unstable pelvic fractures, can achieve good fracture reduction and definitive stabilization with minimum complications and obtain excellent functional outcomes.

    Release date:2020-02-18 09:10 Export PDF Favorites Scan