west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "plasty" 807 results
  • A ANATOMIC SURVEY OF THE IMPLAN-TED PLANE OF IMPLANTATION ANDSTABILITY OF SILICONE NOSE IMPLANTIN AUGMENTATION RHINOPLASTY

    The noses of eight patients being dead for 2hours were dissected to investigate the layers andstructure of the nose, and the stability of theimplanted silicone noae prosthesis was tested.According to the structure and microstructure ofthe nose studied by us, we suggested a newconcept of nasal muscle and dorsal deepfasciacomplex. We confirmed the prcathesis should beimplanted in the space between the nasal boneand the complex. The reason for complicationhappened in this approach was that...

    Release date:2016-09-01 11:17 Export PDF Favorites Scan
  • Cardiac Valve Operation in Children

    Objective To report the experiences of cardiac valve operation in children. Methods Cardiac valve operations were performed in 87 children who were 58 male and 19 female between age of 4 to 14 years (mean 10.2 years). Of the 87 patients, 36 underwent mitral valve replacement, 13 aortic valve replacement, 6 mitral and aortic valve replacement, 13 aortic valvuloplasty, and 19 mitral valvuloplasty. Associated cardiac lesions were simultaneously managed. Results Postoperative complications included low car...

    Release date:2016-08-30 06:35 Export PDF Favorites Scan
  • REPLACEMENT OF INVERT-TYPE ARTIFICIAL TOTAL SCAPULA AND SHOULDER JOINT PROSTHESIS FOR MALIGNANT TUMOR

    Objective To estimate the clinical curative effect of replacement of inverttype artificial total scapula and shoulder joint prosthesis and reserving arm with rehabilitation of function in the treatment of malignant tumor in shoulder. Methods From February 2001 and November 2004, five youth patients with primary malignant shoulder tumors were treated operatively by resection of neoplasmsthoroughly, replacement of inverttype artificial total shoulder blade and joint prosthesis, the functional reconstruction. Of them, there were 4 males and 1 female, aging from 19 to 26 years with an average of 23.6 years. Two cases were diagnosed as having osteosarcoma, one as having chondrosarcoma, and 2 as having Ewing sarcoma. After operation, the upper limbs was immobilized for 3 weeks. The rehabilitation training including passive exercise and initiative exercise. Results The average operative time was 425 min (380 to 530 min), and the blood loss ranged from 1 250 ml to1 900 ml(1 540 ml on average). The follow-up ranged from 7 to52 onths,with an average of 24.6 months. Postoperative complication included 1 case of pneumothorax, one case of shoulder incision skin part necrosis and 1 case of clavicle stump raising and pierce skin with shallow infection. No complication of postoperative incision deeply infection, nerve damage and prosthesis exposure or dislocation occurred. According to the scoring system of JOA(Japan orthopaedics association), the average score was 65 (60 to 72). The flexion and extension function of elbow joint recovered to normal. Conclusion The replacement of inverttype artificial total scapula and shoulder joint prosthesis is an efficacious method for the treatment of malignant tumor in shoulder. There are advantages of numerous adaption, wide range of motion and goodstability. It can not only reserve arm but also rehabilitate function.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • A NEW METHOD TO REPAIR ARTERY INJURIES IN EXTREMITIES BY PHLEBOPLASTY OF BRANCHED VEIN GRAFT

    In order to develope a new method to overcome the difficulties in anastomosis of blood vessels with different diameter, phleboplasty was utilized at the join-point to expand the diameter of branched vein graft, with a funnel-shaped stoma formed consequently. After successfully experimented in fresh blood vessels in vitro, the method was practised clinically to repair injured arteries in extremities, with the outcome that phleboplasty of branched vein graft could enlarge the diameter by 1-1.25 times, and with satisfied effects in 3 clinic cases. So, the conclusion was that: phleboplasty of branched vein graft was a new effective and convinient method to repair injured arteries with different diameters

    Release date:2016-09-01 11:07 Export PDF Favorites Scan
  • Effectiveness of acetabular revision using a metal reconstruction cage

    ObjectiveTo explore the clinical outcomes of acetabular revision using a metal reconstruction cage. MethodsBetween October 2006 and October 2013, 16 patients (16 hips) underwent acetabular revision with a metal reconstruction cage. There were 4 males and 12 females, with the mean age of 62.7 years (range, 49-78 years). The time from total hip arthroplasty to revision was 3-15 years (mean, 8.2 years). The causes for revision were aseptic acetabular loosening in 15 cases, and femoral periprosthetic fracture (Vancouver type B3) in 1 case. According to the American Academy of Orthopaedic Surgeons (AAOS) classification, there were 12 cases of type III and 4 cases of type IV; according to the Paprosky classification, there were 12 cases of type IIIA and 4 cases of type IIIB. Harris score was used for hip function evaluation, and visual analogue scale (VAS) for pain in the thigh. X-ray films were taken for imaging evaluation. ResultsHealing of incision by first intention was obtained in all patients. Deep venous thrombosis occurred in 1 patient, and was cured after anticoagulation therapy. No complications of infection, neurovascular injury, and prosthetic dislocation were found. Sixteen patients were followed up 6.8 years on average (range, 2-9 years). The Harris score was significantly increased from preoperative 42.44±4.66 to 91.88±3.28 at last follow-up (t=–106.30, P=0.00). Two patients had mild pain in the thigh, but pain disappeared at 1 year after operation. At immediate after operation, the abduction angle was 37-54° (mean, 42.9°). The distance between acetabular rotation centre and teardrop line was (33.67±12.19) mm for preoperative value and was (20.67±9.63) mm for postoperative value, showing significant difference (t=–9.60, P=0.00). The distance between acetabular rotation centre and lateral teardrop was (34.98±12.30) mm for preoperative value and was (40.04±6.61) mm for postoperative value, showing significant difference (t=–3.15, P=0.00). X-ray film results showed bony fusion at the osteotomy sites at 4 to 12 months after operation. No continuous radiolucent line, prosthetic dislocation, or osteolysis was found, and bony ingrowth was observed in all patients. No patient received re-revision due to prosthetic loosening. ConclusionThe metal reconstruction cage for acetabular revision can achieve good effectiveness for patients with serious bone defect.

    Release date:2017-06-15 10:04 Export PDF Favorites Scan
  • TOTAL HIP ARTHROPLASTY FOR TREATMENT OF DEVELOPMENTAL DYSPLASIA OF THE HIP

    Objective To summarize the techniques of the total hip arthroplasty in the treatment of osteoarthritis secondary to developmental dysplasia of the hip joint(DDH). Methods Between February 1986 and November2004, a total of 32 hips in 24 patients with advanced osteoarthritis secondary to DDH underwent the total hip arthroplasty. Among the patients, 4 were male and 20 were female, with their ages ranging from33 to 59 years and an average age of 47 years. The bilateral arthroplasty was performed in 8 patients and the unilateral arthroplasty in 16 patients. The patients mainly suffered from pain and claudication. According to the Hartofilakidis classification, semi-dislocation occurred in 2 hips, lowdislocation in 21 hips,and high-dislocation in 9 hips; and the Harris scores before operation were 56.70±2.75, 36.09±4.16, and 29.45±2.16, respectively. Results All the patients were followed up for 6 months to 8 years (averaged 3 yearsand 4 months). The Harris scores after operation were 93.10±2.10,92.7±3.20,and 88.09±3.67,respectively. The differences between peroperation and postoperation were significant(P<0.01). All the patients were pain-free and there wasno sign of aseptic loosening and subsidence. Conclusion The total hip arthroplasty is an effective method for the treatment of osteoarthritis secondary to DDH. The key techniques for the total hip arthroplasty are as follows: deepening the medial wall of the acetabulum, improving the techniques of the bone graft, and firmly placing the acetabular component in the true acetabulum. 

    Release date:2016-09-01 09:26 Export PDF Favorites Scan
  • RELATIONSHIP BETWEEN INITIAL STABILITY AND INFECTED LOOSENING OF TOTAL HIP ARTHROPLASTY PROSTHESIS

    Objective To investigate the relationship between the initial stabil ity and infected loosening of the total hip arthroplasty (THA) prosthesis. Methods From January 2000 to December 2008, 110 cases (110 hips) were treated with THA revision. Among them, 15 cases (15 hips) were confirmed infected loosening. There were 8 males and 7 females with anaverage age of 62 years (range 42-75 years). The infected signs were found from 6 months to 2 years after initial THA. All of them had Tsukayama type IV and late infection, including 6 cases of acetabular infected loosening (5 cases of one-stage and 1 case of two-stage acetabular revision), 7 cases of simple infected loosening of femoral prosthesis (4 cases of one-stage and 3 cases of twostage femoral prosthesis revision), and 2 cases of joint capsule infection and sinus without prosthesis loosening (debridement and continuous irrigation). Results All incisions healed by first intention. Fifteen patients were followed up for 12 to 36 months (average 24 months). In 13 cases of revision, postoperative X-ray films showed that femoral acetabular prostheses were in good position, and had no cl inical and imaging infective signs of loosening. In 2 cases of joint capsule infection, sinus recurred 6 months postoperation without hip joint pain, the function of weight-bearing and walking of hip joint was normal. Harris score increased from preoperative average of 42 to postoperative average of 85; the results were excellent in 4 cases, good in 7 cases, and fair in 4 cases. Conclusion The infection of THA may occur in the whole joint, half-joint or just in joint capsule. The initial stabil ity of the prosthesis would affect the long-term survival of the prothesis. If the prosthesis initial stabil ity is obtained, even if there are infective factors, infections would also be l imited.

    Release date:2016-08-31 05:47 Export PDF Favorites Scan
  • APPLICATION OF SARTORIUS MUSCLE IN THE QUADRICEPSPLASTY

    OBJECTIVE: Extension stiffness of knee joint is always treated by the quadricepsplasty, but the main deficiency of this method is that patient feels weakness of lower limb and easily kneels down. The aim of this article is to explore the method to resolve the complications after quadricepsplasty. METHODS: Since 1978 to 1997, on the basis of traditional procedures of quadricepsplasty, sartorius muscle was used to reinforce the extension of knee joint. The lower 2/3 of sartorius muscle was fully dissociated only with its insertion intact. A tendon-periosteal-bone flap, about 2 cm in width, was managed on the anterior surface of patella, with its pedicle on the medial edge of patella. The tendon-periosteal-bone flap was used to fix the dissociated sartorious into patella to reinforce the extension of knee joint. The very lower part of sartorius was mainly aponeurosis, with the help of an aponeurosis bundle of iliotibial tract, it was fixed into the insertion of patellar ligament, through a bony tunnel chiseled adjacent to the insertion of patellar ligament. By now the movement of knee joint extension was strengthened by the transferred sartorius muscle. Postoperatively, every patient was required to extend and flex knee joint actively and/or passively. Altogether 12 patients were treated, 9 of them were followed up with an average of 14 months. RESULTS: The average movement was increased from 15 degrees to 102 degrees, and the average myodynamia was improved from grade II to grade IV. CONCLUSION: Traditional quadricepsplasty co-operated with transfer of sartorius muscle can strengthen the myodynamia of knee joint extension. It is simple method and can really achieve good function.

    Release date:2016-09-01 11:05 Export PDF Favorites Scan
  • USE OF SMARTPHONE IN ACETABULAR COMPONENT ANGLE MEASUREMENT DURING TOTAL HIP ARTHROPLASTY

    ObjectiveTo evaluate the accuracy of using smartphone to measure the angle of acetabular component in total hip arthroplasty (THA). MethodsBetween June 2012 and September 2015, the acetabular abduction and anteversion angles were measured in 50 patients undergoing THA. There were 24 males and 26 females, aged 37 to 83 years (mean, 71 years). The left hip was involved in 22 cases and the right hip in 28 cases. Of 50 patients, 34 suffered from fracture of the femoral neck, and 16 suffered from avascular necrosis of the femoral head. Acetabular dysplasia was excluded in all cases. A smartphone was used to measure the acetabular abduction and anteversion angles during operation; standard Picture Archiving and Communication Systems (PACS) was used to measured the acetabular abduction and anteversion angles on the X-ray film at 1 week after operation. It was defined as positive that the component angle values by PACS measurement were greater than those by the smartphone measurement, whereas as negative. The two measurement methods were compared, and intra-observer variability was assessed by analyzing the intraclass correlation coefficient (ICC), the Mann-Whitney U-test was used to analyze difference. ResultsThe ICC was 0.84 in the acetabular component angles by smartphone and PACS measurement methods. The acetabular component abduction angle was (44.02±1.33)° and the anteversion angle was (17.62±2.20)° by smartphone measurement. The acetabular component abduction angle was (44.74±4.05)° and the anteversion angle was (17.22±5.57)° by PACS measurement. There was no significant difference between two measurement methods (Z=-1.977, P=0.482; Z=-0.368, P=0.713). The acetabular component angle was in the safe zone in 44 cases; and the acetabular component anteversion angle was beyond safe range of 1 to 5°, and the abduction angle was beyond safe range of 1 to 3° in 6 cases. Intra-measurement variability was -21 to +10° for the anteversion angle and -10 to + 9° for the abduction angle, indicating that the acetabular component anteversion angle by smartphone measurement was greater than that by the PACS measurement, and the abduction angle was less than that by PACS measurement. ConclusionSmartphone is a convenient tool to measure the acetabular component angle in THA.

    Release date:2016-10-02 04:55 Export PDF Favorites Scan
  • MODIFIED ROBOTIZED HYDRAULIC TENSOR FOR LIGAMENT BALANCE IN TOTAL KNEE ARTHROPLASTY

    Objective To investigate a modified robotized hydraulictensor for management of the ligament balance in the total knee arthroplasty. Methods The effect of the modified robotized hydraulic tensor on the mechanical behaviour of the ligament system balance in the total knee arthroplasty was analyzed andthe related information was obtained. Results The robotized hydraulic tensor acted as a tensorsensor system, which could assist the surgeon by providing thequantitative information to align the lower limb in extension, equalize the articular spaces in extension and flexion, balance the internal and external forces, and define the femoral component rotation, and by providing the information toplan the releasing of the soft tissues and the rotating of the femoral component. Conclusion The modified robotized hydraulic tensor can enable the surgeon to properly manage the ligament balance in the total knee arthroplasty.

    Release date:2016-09-01 09:20 Export PDF Favorites Scan
81 pages Previous 1 2 3 ... 81 Next

Format

Content