west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "property" 37 results
  • EXPERIMENTAL RESEARCH IN VITRO ON ANTIBACTERIAL PROPERTY AND BIOCOMPATIBILITY OF ILVERCONTAINING HYDROXYAPATITE COATING

    Objective To prepare silver-containing hydroxyapatite coating (hydroxyapatite/Ag, HA/Ag) and investigate its antibacterial property and biocompatibil ity in vitro. Methods Vacuum plasma spraying technique was adopted to prepare HA/Ag coating on titanium alloy substrate (3% Ag). After incubating the HA/Ag and the HA coating under staphylococcus aureus and pseudomonas aeruginosa suspensions of 2% tryptic soy broth (TBS) medium for 2, 4 and 7 days, respectively, the biofilm on the coatings was examined by confocal laser scanning microscope, and the bacterial density and viable bacterial percentage of bacterial biofilm were calculated. Meanwhile, the micro-morphology of bacterial biofilm was observed by SEM, the cytotoxicity was detected via MTT and the biocompatibil ity of biofilm was evaluated by acute aemolysis test. Results Compared with HA coating, the bacterial biofilm’s thickness on the surface of HA/Ag coating witnessed no significant difference at 2 days after culture (Pgt; 0.05), but decreased obviously at 4 and 7 days after culture (P lt; 0.01). The bacterial density of the biofilm increased with time, but there was no significant difference between two coatings (P gt; 0.05) at 2, 4 and 7 days after culture. The viable bacterial percentage of the biofilms on the surface of HA/Ag coating decreased obviously compared with that of HA coating at 2, 4 and 7 days after cultureP lt; 0.01). The MTT notified the cytotoxic grade of both coatings was zero. The acute haemolysis assay showed that the hemolytic rate of HA/Ag and HA coating was 0.19% and 0.12%, respectively. Conclusion With good biocompatibil ity, significant antibacterial property against staphylococcus aureus and pseudomonas aeruginosa, no obvious cytotoxicity and no erythrocyte destruction, the vacuum plasma sprayed HA/Ag coating is a promising candidate for the surface of orthopedic metal implants to improve their osseointegration and antibacterial property.

    Release date:2016-09-01 09:05 Export PDF Favorites Scan
  • EFFECTS OF MULTIPLE FREEZE-THAW ON BIOMECHANICAL PROPERTIES OF HUMAN ALLOGRAFT TENDONS

    Objective To explore the biomechanic effects of multi ple freeze-thaw on human allograft tendons. Methods Thirty tendons (24 flexor digitorum superficial is tendons and 6 flexor poll icis longus tendons) were harvested from 3 fresh cadaver donors and were divided into 6 groups randomly (fresh group; 1 cycle, 2 cycle, 3 cycle, 5 cycle, and 10 cycle freeze-thaw groups). There was 4 flexor digitorum superficial is tendons and 1 flexor poll icis longus tendon in each group. The structural and mechanical properties as well as viscoelastic change were estimated. Results The results of the structural and mechanical properties in 1 cycle, 2 cycle, and 3 cycle freeze-thaw groups were similar to that of the fresh group (P gt;0.05). The tendons in 5 cycle and 10 cycle freeze-thaw groups showed a significantly lower ultimate load and maximum stress when compared with those of fresh group (P lt; 0.05), but there was no significant difference in maximum tensile or maximum strain (P gt; 0.05). Moreover, the tendons in 5 cycle and 10 cycle freeze-thaw groups had a significant increase in viscoelastic properties when compared with fresh group (P lt; 0.05). Conclusion In the cryopreservation of tendon allografts, the cycle of freeze-thaw should not exceed 3 times. Multiple cycle freeze-thaw will weaken the biomechanical properties of tendon allografts, which make grafts easier to fatigue or even rupture.

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
  • Structure design of a new video laryngoscope image sensor

    In order to overcome the influence of stray light and impurity on the image of video laryngoscope, we designed an optical structure by using TracePro, a simulation software, to imitate optical path status. Images are captured by CMOS sensor which has the size of 4.5 mm×18 mm and the pixel size is 1.75 μm×1.75 μm. The sensor is placed in the elbow of the laryngoscope, and the elbow has the size of 9 mm×10 mm. As a result, the video laryngoscope could meet the requirements, including wide viewing angle (80°), short focal length (2.8 mm), long working distance (10 cm), and least impurity. In the test, the image was clear and there was no facula or impurity in the condition of required illumination, and thus stray light and image impurity were eliminated and the image quality was improved.

    Release date:2017-04-01 08:56 Export PDF Favorites Scan
  • STUDY OF RHEOLOGIC PROPERTY OF BILE FLOW BETWEEN GALLBLADDER AND DUCT DURING EXPERIMENTAL BILIARY OBSTRUCTION

    In order to study rheologic property of bile flow between gallbladder and biliary duct during biliary obstruction,we made a model of complete biliary obstruction(CBO)in dogs.The results showed that:①The behavior of bile flow between gallbladder and biliary duct in noemal dogs belonged to Casson flow;②When the duration of CBO prolonged,the behavior of bile flow between gallbladder and biliary tract in the CBO dogs still belonged to Casson flow.The changes of yield stress and apparent viscosity at high or low shear rate in bile flow of the biliary duct were similar to that in bile flow of the gallbladder.

    Release date:2016-08-29 03:24 Export PDF Favorites Scan
  • Comparative study on Sichuan yak pericardium and Australian cattle pericardium

    Currently, as the key raw material of artificial biological heart valve, bovine pericardium is mainly depend on import and has become a “bottleneck” challenge, greatly limiting the development of domestic biological heart valve. Therefore, the localization of bovine pericardium is extremely urgent. In this study, the pericardium of Sichuan yak was compared with that of Australian cattle in terms of fundamental properties and anti-calcification performance. The results demonstrated that the appearance and thickness of yak pericardium were more advantageous than the Australian one. Sichuan yak pericardium and Australian cattle pericardium had comparable performance in shrinkage temperature, mechanical test and anti-calcification test. This study preliminarily verifies the feasibility of substitution of Australian cattle pericardium by Sichuan yak pericardium and promotes the progression of bovine pericardium localization with data support.

    Release date:2022-08-22 03:12 Export PDF Favorites Scan
  • Study on antibacterial properties of titanium metallic surface due to synergistic action of micro/nano-structure and antimicrobial peptides

    ObjectiveTo investigate the effects of micro/nano-structure and antimicrobial peptides (AMPs) on antibacterial properties of titanium (Ti) metallic surface.MethodsTi disks were treated via sandblasted large-grit acid-etched (SLA) and alkali-heat treatment (AHT) to build the micro/nano-structure, on which AMPs were spin-coated with a certain amount (10, 30, 50, 70, and 90 μg). Scanning electron microscope (SEM) and energy dispersive spectroscopy (EDS) were used to observe the surface structure and characterize the surface elements (i.e. contents of C, N, O, and Ti). Ti disks loaded with AMPs of difference amounts were co-cultured with Staphylococcus aureus (S. aureus) for 24 hours. After that, the formation and dimension of antibacterial circle were measured. Furthermore, the Ti disks treated with different approaches (untreated, SLA treatment, SLA+THA treatment, and 90 μg AMPs-loaded samples) were co-cultured with S. aureus and Escherichia coli (E.coli) for 3 hours, bacterial adhesion on the disks were evaluated by using SEM. The antibacterial performances in solution were quantitatively evaluated by immersing the Ti disks in bacterial solutions and measuring the absorbance (A) values.ResultsIt was found that the nanoporous structure could be easily constructed by SLA+AHT approach. After spin-coating AMPs, the nanopores with the diameter less than 200 nm were almost covered. According to the element analysis, with the increase of AMPs, the C content gradually increased; the N content was not detected until AMPs amount reached 70 μg on the disks. The diameter of antibacterial circle clearly depended on the AMPs amount. The Ti disks loaded with 90 μg AMPs had significantly larger antibacterial circles than the other Ti disks (P<0.05). Based on the SEM observation, the Ti disks loaded with 90 μg AMPs has the least bacterial attachment compared with the other Ti disks (P<0.05). TheA value of bacterial solution immersed with the Ti disks loaded with 90 μg AMPs was much lower than the other Ti disks (P<0.05).ConclusionThe approach of micro/nano-structure and AMPs can improve the antibacterial properties of Ti metallic surface.

    Release date:2018-09-03 10:13 Export PDF Favorites Scan
  • MECHANICAL PROPERTIES OF POLYLACTIC ACID/β-TRICALCIUM PHOSPHATE COMPOSITE SCAFFOLD WITH DOUBLE CHANNELS BASED ON THREE-DIMENSIONAL PRINTING TECHNIQUE

    ObjectiveTo improve the poor mechanical strength of porous ceramic scaffold, an integrated method based on three-dimensional (3-D) printing technique is developed to incorporate the controlled double-channel porous structure into the polylactic acid/β-tricalcium phosphate (PLA/β-TCP) reinforced composite scaffolds (double-channel composite scaffold) to improve their tissue regeneration capability and the mechanical properties. MethodsThe designed double-channel structure inside the ceramic scaffold consisted of both primary and secondary micropipes, which parallel but un-connected. The set of primary channels was used for cell ingrowth, while the set of secondary channels was used for the PLA perfusion. Integration technology of 3-D printing technique and gel-casting was firstly used to fabricate the double-channel ceramic scaffolds. PLA/β-TCP composite scaffolds were obtained by the polymer gravity perfusion process to pour PLA solution into the double-channel ceramic scaffolds through the secondary channel set. Microscope, porosity, and mechanical experiments for the standard samples were used to evaluate the composite properties. The ceramic scaffold with only the primary channel (single-channel scaffold) was also prepared as a control. ResultsMorphology observation results showed that there was no PLA inside the primary channels of the double-channel composite scaffolds but a dense interface layer between PLA and β-TCP obviously formed on the inner wall of the secondary channels by the PLA penetration during the perfusion process. Finite element simulation found that the compressive strength of the double-channel composite scaffold was less than that of the single-channel scaffold; however, mechanical tests found that the maximum compressive strength of the double-channel composite scaffold[(21.25±1.15) MPa] was higher than that of the single-channel scaffold[(9.76±0.64) MPa]. ConclusionThe double-channel composite scaffolds fabricated by 3-D printing technique have controlled complex micropipes and can significantly enhance mechanical properties, which is a promising strategy to solve the contradiction of strength and high-porosity of the ceramic scaffolds for the bone tissue engineering application.

    Release date: Export PDF Favorites Scan
  • Study on the preparation of polycaprolactone/typeⅠcollagen tissue engineered meniscus scaffold by three-dimensional printing and its physiochemical properties

    ObjectiveTo manufacture a polycaprolactone (PCL)/type Ⅰ collagen (COL Ⅰ) tissue engineered meniscus scaffold (hereinafter referred to as PCL/COL Ⅰ meniscus scaffold) by three-dimensional (3D) printing with low temperature deposition technique and to study its physicochemical properties.MethodsFirst, the 15% PCL/4% COLⅠ composite solution and 15% PCL simple solution were prepared. Then, 15% PCL/4% COL Ⅰmeniscus scaffold and 15% PCL meniscal scaffold were prepared by using 3D printing with low temperature deposition techniques. The morphology and microstructure of the scaffolds were observed by gross observation and scanning electron microscope. The compression modulus and tensile modulus of the scaffolds were measured by biomechanical test. The components of the scaffolds were analyzed by Fourier transform infrared spectroscopy (FTIR). The contact angle of the scaffold surface was measured. The meniscus cells of rabbits were cultured with the two scaffold extracts and scaffolds, respectively. After cultured, the cell proliferations were detected by cell counting kit 8 (CCK-8), and the normal cultured cells were used as controls. Cell adhesion and growth of scaffold-cell complex were observed by scanning electron microscope.ResultsAccording to the gross and scanning electron microscope observations, two scaffolds had orientated 3D microstructures and pores, but the surface of the PCL/COLⅠ meniscus scaffold was rougher than the PCL meniscus scaffold. Biomechanical analysis showed that the tensile modulus and compression modulus of the PCL/COL Ⅰ meniscus scaffold were not significantly different from those of the PCL meniscus scaffold (P>0.05). FTIR analysis results showed that COL Ⅰ and PCL were successful mixed in PCL/ COL Ⅰ meniscus scaffolds. The contact angle of PCL/COLⅠ meniscus scaffold [(83.19±7.49)°] was significantly lower than that of PCL meniscus scaffold [(111.13±5.70)°] (t=6.638, P=0.000). The results of the CCK-8 assay indicated that with time, the number of cells cultured in two scaffold extracts showed an increasing trend, and there was no significant difference when compared with the control group (P>0.05). Scanning electron microscope observation showed that the cells attached on the PCL/ COL Ⅰ meniscus scaffold more than that on the PCL scaffold.ConclusionPCL/COLⅠmeniscus scaffolds are prepared by 3D printing with low temperature deposition technique, which has excellent physicochemical properties without cytotoxicity. PCL/COLⅠmeniscus scaffold is expected to be used as the material for meniscus tissue engineering.

    Release date:2018-09-03 10:13 Export PDF Favorites Scan
  • EFFECT OF SURFACE PROPERTY OF DIFFERENT POLYETHER-ESTER COPOLYMERS ON GROWTH OF SMOOTH MUSCLE CELLS AND ENDOTHELIAL CELLS

    Objective To investigate the effect of surface propertyof different polyether-ester block copolymers[poly(ethylene glycol-terephthalate)/poly(butylene terephthalate), PEGT/PBT] on the growth of smooth muscle cells (SMCs) and endothelial cells(ECs). Methods Three kinds of copolymers were synthesized, which were 1000-T20 (group A), 1000PEGT70/PBT30 (group B) and 600PEGT70/PBT30 (group C). The water-uptake and contact angle of three polyether-ester membranes were determined. The canine aorta smooth muscle cells and external jugular vein endothelial cells were primarily harvested, subcultured, and then identified. The proliferation of SMCs and ECs on the different polyether-ester membranes were investigated. Results The water-uptake of three copolymers arranged as the sequence of group C<group A<group B, and contact angle as the sequence of group C>group A>group B, indicating group B being more hydrophilic. However, smooth musclecells andendothelial cells grew poorly on the membrane of group B after low density seeding, but proliferated well on the membranes of group A and group C. Conclusion In contrast with more hydrophilic 1000PEGT70/PBT30, moderately hydrophilic 1000-T20 and 600PEGT70/PBT30 has better compatibility with vascular cells. The above results indicate that the vascular cells can grow well on moderately hydrophilic PEGT/PBT and that PEGT/PBT can be used in vascular tissue engineering. 

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • Methods of improving the mechanical properties of hydrogels and their research progress in bone tissue engineering

    ObjectiveTo review the methods of improving the mechanical properties of hydrogels and the research progress in bone tissue engineering. MethodsThe recent domestic and foreign literature on hydrogels in bone tissue engineering was reviewed, and the methods of improving the mechanical properties of hydrogels and the effect of bone repair in vivo and in vitro were summarized. ResultsHydrogels are widely used in bone tissue engineering, but their mechanical properties are poor. Improving the mechanical properties of hydrogels can enhance bone repair. The methods of improving the mechanical properties of hydrogels include the construction of dual network structures, inorganic nanoparticle composites, introduction of conductive materials, and fiber network reinforcement. These methods can improve the mechanical properties of hydrogels to various degrees while also demonstrating a significant bone repair impact. ConclusionThe mechanical properties of hydrogels can be effectively improved by modifying the system, components, and fiber structure, and bone repair can be effectively promoted.

    Release date:2022-01-12 11:00 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content