west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "prosthesis replacement" 5 results
  • Application of proximal tibial hemiprosthesis replacement and second-stage revision for proximal tibial osteosarcoma in three children

    ObjectiveTo investigate the feasibility and effectiveness of proximal tibial hemiprosthesis replacement in the first stage and prosthesis revision in the second stage in reducing the risk of length discrepancy of limbs in children with proximal tibial osteosarcoma.MethodsBetween 2009 and 2013, 3 children with conventional osteosarcoma at the proximal tibia (stage ⅡB) were treated. There were 2 boys and 1 girl. They were 12, 13, and 13 years old, respectively. After 4 courses of preoperative chemotherapy, the proximal tumor segmental resection and proximal tibial hemiprosthesis replacement were performed. Then the patients underwent prosthetic revision in the second stage when they were 20, 17, and 17 years old, respectively.ResultsAll patients successfully completed two stages of operations. The length discrepancy of lower limb after the second stage operation were 19, 7, and 21 mm, respectively. Three patients were followed up 13, 3, and 27 months after the second stage operation, and the lower extremities functions were satisfactory. The Musculoskeletal Tumor Society (MSTS) score was 26, 27, and 25, respectively.ConclusionThe proximal tibial hemiprosthesis replacement in the first stage combined with prosthesis revision in the second stage for treating the proximal tibia osteosarcoma in children can keep the distal femur growth ability, reduce the length discreapancy of lower limb, and obtain satisfactory stability and good function.

    Release date:2019-01-25 09:40 Export PDF Favorites Scan
  • SURGICAL TREATMENT OF INFRARENAL ABODOMINAL AORTIC ANEURYSMS

    Objective To explore the method of surgical treatment and endoluminal repairs of infrarenal abdominal aortic aneurysm (AAA)so as to improve the safety of surgical treatment. Methods The information of surgical treatment was analysed restrospectively in 195 cases of infrarenal AAA treated from January 1981 to December 2004. Of the patients, 155 were males, 40 were females with a mean age of 56.5 years. The diametersof the aneurysm were larger than 5 cm in 183 patients (93.8%) and 4 to 5 cm in12 patients (6.2%). Of the 175 patients who underwent selective operation, graft replacements were performed in 139 and endovascular aneurysmal repairs in 36. Twenty patients (10.3%) suffering from aneurysm rupture were given emergency operation. Results There were 6 deaths in the patients underdingselective operation(6/175, 4.3%) and in those undergoing emergengcy surgery (6/20, 30%) respectively within 30 days. The other patients were followed up from 1 month to 21 years ( 8.7 years on average), and there were 16 deaths (8.9%) during the follow-up. Nodeath was found in the endoluminal repaired group. Endoleak occurred in 8 patients, including 5 cases of type Ⅰand 3cases of type Ⅱ. After 6 months, CT scan showed that endoleak disappeared in 6 and rernained in 2. Late type Ⅱ endoleak occurred in 1 and endoleak disappearedafter endoluminal embolization. Conclusion With improvement of vascular surgical technique and development of endogafting, the safety of AAA both on surgicaland interventional means would be improved.

    Release date:2016-09-01 09:28 Export PDF Favorites Scan
  • APPLICATION OF PROSTHESIS REPLACEMENT IN LIMB SALVAGE TREATMENT OF MILD-MALIGNANT TUMORS AT THE ARTICULAR ENDS OF FEMURS

    ObjectiveTo investigate the clinical outcome of application of joint prosthesis in limb salvage treatment of mildmalignant tumor at the articular ends of femurs, with severe osteolysis. Methods The treatment of 15 cases of mildmalignant tumor at the articular ends of femurs with severe bone destruction, from 1978 to 1999, was reviewed. There were 10 cases of giant-cell bone tumor and 5 cases of chondrosarcoma, among which there were 5 cases at the stage ofⅠA, 9 cases at ⅠB, and 1 case at ⅡA, with 4 cases at the proximal end and 11cases at the distal end. The tumor was totally removed, with a massive bone defect left at the foci, and then the prosthesis replacement was performed to reconstruct the articular joint. All of the 15 patients were followed up for 9 monthsto 20 years, 4 years and 3 months on average, before clinical evaluation. Results All of the wound healed well, with primary healing. Local relapse occurred in one case and the patient died of lung metastasis; the amputation of the replaced knee joint was performed in one case due to severe infection after trauma; radiograph showed there was slight sunk of the prosthesis in 2 cases after replacement. The other 11 cases recovered well with satisfactory function. Conclusion The limb salvage treatment of mildmalignant tumor at the articular ends of femurswould be available, especially for those with massive bone destruction, when the tumor is removed by whole and rationally marginal resection, followed by properlyutilization of prosthesis and general post-operative exercise. 

    Release date: Export PDF Favorites Scan
  • Effectiveness evaluation of three-dimensional printed customized hemi-pelvic prosthesis for pelvic reconstruction after resection of massive pelvic tumor

    Objective To investigate the effectiveness of three-dimensional (3D) printed customized hemi-pelvic prosthesis for pelvic reconstruction after resection of massive pelvic tumors. Methods A retrospective analysis was conducted on 26 patients with massive pelvic tumors who met the selection criteria and were treated between November 2021 and May 2025. The cohort included 11 males and 15 females, with a mean age of 52.65 years (range, 17-73 years). Histopathological diagnoses were as follows: 9 cases of chondrosarcoma, 2 of undifferentiated pleomorphic sarcoma, 4 of spindle cell sarcoma, 2 of osteosarcoma, 1 of solitary fibrous tumor, 1 of myxoid chondroma, 1 of malignant peripheral nerve sheath tumor, 1 of chondromyxoid epithelioma, and 5 of metastatic malignant tumors. According to the Enneking classification, tumor involvement was distributed as 4 cases in zones Ⅰ+Ⅱ, 9 in zones II+III, 3 in zones Ⅰ+Ⅳ, 8 in zones Ⅰ+Ⅱ+ⅢI, and 2 in zones Ⅰ+Ⅱ+Ⅳ. The disease duration ranged from 3 to 40 months, with a mean of 9.85 months. All patients underwent reconstruction with customized 3D-printed hemi-pelvic prostheses. The effectiveness was evaluated by Musculoskeletal Tumor Society (MSTS) score and Harris hip score before operation and at last follow-up, and pain levels were evaluated by visual analogue scale (VAS) score before operation, at 3 months after operation, and at last follow-up. ResultsThe operation time ranged from 186 to 528 minutes, with a mean of 334.58 minutes. The intraoperative blood ranged from 1 400 to 4 000 mL, with a mean of 2173.08 mL, and the transfusion volume ranged from 750 to 3 500 mL, with a mean of 1 659.62 mL. All 26 patients were followed up 10-42 months (mean, 18.5 months). Postoperative complications included prosthetic dislocation in 2 cases, which were attributed to improper positioning during home care and an accidental fall, respectively. One patient developed a vesicocutaneous fistula and poor wound healing due to pre-existing tumor invasion into the bladder. One patient experienced failure and loosening of the internal fixation at 8 months after operation caused by local tumor recurrence, and subsequently died at 14 months postoperatively due to progression of brain metastases. Postoperative complications such as poor healing of incisions, prosthetic dislocation, or failure of internal fixation were not observed in the remaining patients. At last follow-up, the walking ability of most patients recovered to varying degrees. The VAS scores at 3 months and at last follow-up significantly improved when compared with those before operation, and the scores at last follow-up further improved when compared with 3 months after operation, all showing significant differences (P<0.05). The MSTS scores and Harris scores at last follow-up were significantly higher than those before operation (P<0.05). Conclusion 3D printed customized hemi-pelvic prosthesis is effective for reconstruction of massive pelvic tumors after resection, but there are still some limitations, and soft tissue reconstruction should be paid attention to.

    Release date: Export PDF Favorites Scan
  • Reoperation after Mechanical Valve Prosthesis Replacement: An Analysis of 105 Cases

    Abstract: Objective To summarize our operative experiences of cardiac reoperation after mechanical valve prosthesis replacement and investigate the causes of reoperation and the perioperative techniques and operation methods. Methods From January 2001 to December 2008, we performed reoperation on 105 patients (59 males and 46 females, aged 50.2±10.6 years old) who had undergone mechanical valve prosthesis replacement. Among the patients, there were 31 cases of mitral valvular replacement (+ tricuspid valvular plasticity), 38 cases of aortic valvular replacement (+ tricuspid valvular plasticity), 11 cases of Bentall procedure, 7 cases of mitral and aortic bivalvular replacement (+tricuspid valvular plasticity), 8 cases of tricuspid valvular replacement, 6 cases of repairing of prosthetic leakage, and 4 others cases. The time interval between two operations was 3 months to 18 years (46.3 ±31.9 months). Before reoperation, the cardiac function (NYHA) of the patients was class Ⅱ in 27 patients, class Ⅲ in 53 patients, and class Ⅳ in 25 patients. Results There were 6 hospital deaths with a mortality of 5.71%(6/105). All others recovered to NYHA class ⅠⅡ. The causes of mortality included 1 case of multiple organ failure, 1 case of low cardiac output after operation, 1 case of aortic pseudoaneurysm rupture, 1 case of severe infection due to brain complication and 2 cases of prosthetic valve endocarditis (PVE). The causes for cardiac reoperation after mechanical valve prosthesis replacement were 67 cases of prosthetic leakage (63.80%), 16 cases of PVE (15.23%), 14 cases of prosthetic thrombosis (13.33%) and 8 cases of other valvular anomalies. Followup was done for 11 to 107 months, which showed two cases late deaths of cardiac arrest and cerebral hemorrhage. Conclusion Patients who have received mechanical valve prosthesis replacement may undergo cardiac reoperation due to paravalvular prosthetic leakage, paravalvular endocarditis, and prosthetic thrombosis. The keys to a successful cardiac reoperation include appropriate preoperative preparations, operational timing, and suitable choosing of cardiopulmonary bypass and operational skills. 

    Release date:2016-08-30 06:02 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content