west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "stretch" 25 results
  • EFFECTIVENESS OF DISTRACTION THERAPY ASSISTED BY ARTHROSCOPE IN TREATMENT OF ANKLE TRAUMATIC OSTEOARTHRITIS

    ObjectiveTo investigate the effectiveness of distraction therapy assisted by arthroscope in the treatment of ankle traumatic osteoarthritis. MethodsBetween October 2013 and October 2014, 13 patients with ankle traumatic osteoarthritis were treated, including 8 males and 5 females with an age range of 44-63 years (mean, 55.2 years). The left ankle and the right ankle were involved in 4 and 9 cases respectively. The disease duration was 1.5-10.0 years (median, 5 years). The American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hind foot scale score was 51.00±7.09; the short-form 36 health survey scale (SF-36) score was 40.82±4.62. According to Scranton grade system, 9 cases were rated as grade II and 4 cases as grade III. First, ankle hyperplasia osteophytes was removed under arthroscope, then Ilizarov apparatus was used to maintain distraction of 5-10 mm ankle space for 3 months. ResultsOne case had postoperative pin tract infection after removing the external fixation, and infection was controlled by dressing treatment; no related complications occurred in the other patients. All patients got follow-up of 12-18 months (mean, 14.7 months). Patients achieved disappearance of ankle swelling, pain relief, and were able to walk after rehabilitation. The ankle activity was obviously improved. At last follow-up, AOFAS ankel-hind foot scale score and SF-36 score were significantly increased to 85.23±6.41 and 56.29±6.20 respectively (t=20.756, P=0.025; t=11.647, P=0.018). According to AOFAS scores, the results were excellent in 4 cases, good in 8 cases, and fair in 1 case; the excellent and good rate was 92.3%. Postoperative X-ray film showed normal ankle position and alignment, osteophytes at the edges of the tibia and talus, articular surface sclerosis, normal joint space, and no joint swelling. ConclusionDistraction therapy assisted by arthroscope is an effective method for treating ankle traumatic osteoarthritis.

    Release date: Export PDF Favorites Scan
  • EXPERIMENTAL STUDY ON CLOSING THE FIREARM INJURED SOFT TISSUE DEFECT BY SKIN STRETCH

    OBJECTIVE: To investigate the availability and effect of skin stretch in closing the firearm injured soft tissue defect. METHODS: Eight white pigs with firearm injured soft tissue defect were divided into 3 groups. Each group I and group II had 3 pigs which were performed skin stretch. The control group had 2 pigs without stretch. The average diameter of the defect in three groups was (7.3 +/- 0.2) cm, (9.1 +/- 0.3) cm, (7.3 +/- 0.2) cm respectively, and the site of defect was on the lateral thigh and buttock. RESULTS: Skin stretch could make a visible reduction of the wound. It was possible to close the wound by direct traction when the diameter of the buttock wound was less than 7 cm, and when the diameter of the lateral thigh wound was less than the radius of thigh. The skin stretch should not last more than 7 days and the best effect appeared in 4 to 5 days after performing the skin stretch. CONCLUSION: The skin stretch can be applied in the repair of the firearm injured soft tissue defect. It has many advantage compared with the tradtional treatment.

    Release date:2016-09-01 10:20 Export PDF Favorites Scan
  • APPLICATION OF REDUCTION BY POSTERIOR APPROACH TO TREAT SEVERE SPONDYLOLISTHESIS

    Objective To investigate the technique of reduction by posterior approach for severe spondylolisthesis, and to discuss the method to prevent nerve stretch injury. Methods Between July 2007 and April 2011, 17 patients with severe spondylolisthesis underwent reduction, fixation, and fusion by posterior approach. There were 2 males and 15 females with a median age of 15 years (range, 8-67 years) and a median disease duration of 18 months (range, 5 months-16 years and 4 months). The level of spondylolisthesis was at L4 in 1 case and L5 in 16 cases; the spondylolisthesis was at degree III in 12 cases and degree IV in 5 cases according to Meyerding classification. There were 16 cases of developmental spondylolisthesis (high- dysplastic and low-dysplasia spondylolisthesis in 9 and 7 cases, respectively) and 1 case of traumatic spondylolisthesis; 16 cases of developmental spondylolisthesis at L5 level included 6 cases of type 4, 9 case of type 5, and 1 case of type 6 according to Spinal Deformity Study Group (SDSG) classification. All cases underwent posterior spinal decompression, Schanz screw fixation for the slipped vertebrae, the intervertebral and posterolateral fusion and reduction of the slipped vertebrae, and correction of the lumbosacral kyphosis. The reductive degree of slipped vertebrae was modulated according to the strain of exiting spinal root. The slip degree should be reduced within Meyerding degree II. The anteroposterior and lateral radiographs of whole spine were taken in a standardized standing position to observe the correction of displacement severity and lumbosacral angle. The nerve function and pain score of lower extremity were evaluated by neurological Frankel grade and visual analogue scale (VAS). Bony fusion was assessed by followed-up CT three-dimentional reconstruction. Results Exiting nerve root paralysis occurred in 1 case after operation, and released at 4 weeks after operation; no aggravation of nerve damage was observed in the other patients. The incisions primarily healed. All the patients were followed up 12-48 months (mean, 25 months). The slip percentage, the lumbosacral angle, and VAS score of lower extremity were improved from 72% ± 10%, (18.2 ± 3.5)°, and 7.0 ± 1.5 at preoperation to 12% ± 6%, ( — 7.3 ± 2.9)°, and 1.5 ± 1.3 at 12 months after operation respectively, all showing significant differences (P lt; 0.05). Osteosynthesis was seen at the bone grafting area by CT three-dimentional reconstruction at 12 months after operation. No breakage of screw and rod or reduction loss occurred. Conclusion It can obtain satisfactory clinical result to use spinal canal decompression by posterior approach, the Schanz screw fixation of the slipped vertebrae, the intervertebral and posterolateral fusion for severe spondylolisthesis. The risk of nerve stretch injury can be prevented by choosing the lowest height of intervertebral cage, modulating the reductive degree of slipped vertebrae according to the strain of exiting spinal root, and correcting lumbosacral kyphosis.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • Value of stretched exponential model diffusion-weighted imaging in diagnosis of advanced liver fibrosis

    ObjectiveTo investigate the utility of stretched exponential model diffusion-weighted imaging (DWI) for diagnosing of advanced liver fibrosis.MethodsThe patients with chronic liver disease complicated with vary degrees of fibrosis confirmed by pathological examination underwent DWI using different b-values (0, 50, 600 s/mm2) at the First Affiliated Hospital of Chengdu Medical College from June 2015 to February 2020 were collected. In addition, patients who underwent upper abdominal MRI examination in the same hospital at the same time and had no liver disease or disease affecting liver function were collected as a control group. The apparent diffusion coefficient (ADC) was calculated by using a mono-exponential model. The distributed diffusion coefficient (DDC) and water molecular diffusion heterogeneity index (α) were calculated by using a stretched exponential model. The fibrosis stage was evaluated by using the Metavir scoring system. The ADC, DDC, and α among different fibrosis groups were compared. The receiver operating characteristic (ROC) curve was used to analyze the diagnostic efficacy of these three quantitative parameters for advanced liver fibrosis.ResultsA total of 42 patients with chronic liver disease were collected in this study, including mild liver fibrosis (S1–S2, n=16) and advanced liver fibrosi (≥S3, n=24); 15 patients in the control group. The values of ADC, DDC, and α of the patients with mild liver fibrosis and advanced liver fibrosis were significantly lower than those of the control patients (P<0.05). The area under the ROC curve of ADC, DCC, and α in diagnosing liver fibrosis (≥S1) was 0.915, 0.974, and 0.835, respectively, which in diagnosing advanced liver fibrosis (≥S3) was 0.744, 0.869, and 0.758, respectively. However, further the area under ROC curve among these three metrics had no statistical differences (P>0.05).ConclusionDDC based on stretched exponential model is valuable for diagnosis of advanced liver fibrosis.

    Release date:2020-12-25 06:09 Export PDF Favorites Scan
  • REACTION OF HUMAN FIBROBLASTS FROM DIFFERENT SITES TO THE MECHANICAL STRESS

    ObjectiveTo explore the reaction of normal skin fibroblasts from different sites of human body to cyclic stretch. MethodsThe normal skin tissues from scapular upper back and medial side of upper arm of 3 patients were cultured in vitro. Fibroblasts of experimental group were loaded by cyclic stretch with 10% amplitude for 24, 36, and 48 hours respectively. Fibroblasts of control group were cultured without cyclic stretch. The morphologic changes were observed using inverted microscope. CCK-8 method was used to detect the proliferation of the fibroblasts. The expressions of integrin β1 mRNA, p130Crk-associated substance (P130Cas) mRNA, transform growth factor β1 (TGF-β1) mRNA, and collagen type Ⅰ α1 chain (COL1A1) mRNA were detected by real-time quantitative PCR. The protein levels of collagen type Ⅰ and TGF-β1 were detected by ELISA. ResultsThe cultured cells showed a significantly increased cell proliferation ability, and apparent orientation after the applied strain. The proliferation activity, mRNA expression levels of integrin β1, P130Cas, and TGF-β1, protein levels of TGF-β1 in back skin were significantly higher than those in arm skin (P<0.05) when the fibroblasts were loaded for 36 and 48 hours, but no significant difference between back skin and arm skin at 24 hours (P>0.05). There was no significant difference in mRNA expression level of COL1A1 and protein level of collagen type Ⅰ between back skin and arm skin at 24, 36, and 48 hours (P>0.05). There was no significant difference in all above indexes between back skin and arm skin in control group (P>0.05). ConclusionFibroblasts from scapular upper back and medial side of upper arm display different reactions to cyclic stretch, which indicates that there exists site difference in the reactions of fibroblasts to cyclic stretch. It might be related with the incidence of hypertrophic scar in different sites of the body.

    Release date: Export PDF Favorites Scan
  • Application of delayed skin-stretching device in treatment of skin and soft tissue defects

    ObjectiveTo summarize the effectiveness of delayed skin-stretching device in treatment of skin and soft tissue defects.MethodsBetween December 2014 and December 2016, 10 cases of skin and soft tissue defects were treated with delayed skin-stretching device. There were 6 males and 4 females with an average age of 53 years (range, 42-64 years). The skin and soft tissue defects were caused by acute trauma in 6 cases. The incision could not be closed directly after making incisions because of osseous fascia syndrome in 3 cases. The skin soft tissue defect caused after huge carbuncle incision and drainage in 1 case. The defect located at thigh in 4 cases, lower leg in 3 cases, upper arm in 2 cases, back in 1 case. The defect area ranged from 10 cm×4 cm to 22 cm×12 cm. Pinch test was performed on the wound margin, which confirmed that the wound could not be closed directly.ResultsTension blisters were found in 3 cases during traction, and no complications such as impaired blood circulation or skin necrosis occurred in all cases. Skin defects closed directly after continuously stretching for 7-18 days. No skin graft or free flap repair was performed in all patients. The wound healed well after operation. All the 10 patients were followed up 5-8 months (mean, 6.5 months). There was no necrosis around the wound margin and the scar was linear. The sensation and function were not affected.ConclusionDelayed skin-stretching device is an effective method to treat skin and soft tissue defects, which has the advantages of simple operation, lower risk of operation, less complications, and reliable effectiveness.

    Release date:2018-10-09 10:34 Export PDF Favorites Scan
  • Comparison of the value of bedside lung ultrasound and lung stretch index in guiding optimal positive end-expiratory pressure during lung recruitment in patients with acute respiratory distress syndrome

    Objective To investigate the guiding value of bedside lung ultrasound and lung stretch index for optimal positive end-expiratory pressure (PEEP) in lung recruitment of patients with acute respiratory distress syndrome (ARDS). Methods From February 2020 to October 2023, 90 patients with ARDS requiring invasive mechanical ventilation were selected from the Department of Critical Care Medicine, the Second Affiliated Hospital of Zhengzhou University. According to the setting method of PEEP after lung recruitment, they were randomly divided into an ultrasound group (45 cases) and a stretch group (45 cases). Both groups were treated with PEEP incremental method for lung recruitment, and the ultrasound group was treated with bedside ultrasound-guided method to set PEEP after lung recruitment. PEEP was set by lung stretch index method in the stretch group. The dynamic changes of oxygenation index (PaO2/FiO2), dynamic compliance (Cdyn), mean airway pressure and peak airway pressure were monitored before lung recruitment and 15 min, 1 h, 6 h and 24 h after lung recruitment. Heart rate, mean arterial pressure and central venous pressure were monitored before and 24 h after lung recruitment in the two groups. The optimal PEEP value and the corresponding volume at the end of recruitment were explored. The mechanical ventilation time, ICU hospitalization time, incidence of barotrauma, incidence of extrapulmonary organ failure, and 28-day mortality were recorded as well. Results After lung recruitment, the oxygenation index, Cdyn, mean airway pressure, and peak airway pressure in the ultrasound group were higher than those in the stretch group at 15 min, 1 h, 6 h, and 24 h after recruitment (all P<0.05). There was no significant difference in heart rate, mean arterial pressure or central venous pressure between the two groups at 24 h after lung recruitment (all P>0.05). After lung recruitment, the optimal PEEP value and the corresponding volume at the end of recruitment in the ultrasound group were higher than those in the distraction group (both P<0.05). The mechanical ventilation time and ICU stay in the ultrasound group were shorter than those in the stretch group (both P<0.05). There was no significant difference in the incidence of barotrauma, extrapulmonary organ failure rate or 28-day mortality between the two groups (all P>0.05). Conclusions Both bedside lung ultrasound-guided PEEP and lung stretch index-guided PEEP can improve oxygenation and respiratory compliance, and have no adverse effects on hemodynamics. Bedside lung ultrasound-guided PEEP can make the alveoli fully expand, which is more conducive to improving patients’ oxygenation and respiratory compliance, and the guiding value is higher than the lung stretch index.

    Release date:2024-07-29 01:12 Export PDF Favorites Scan
  • Application of modified adjustable skin stretching and secure wound-closure system in repairing of skin and soft tissue defect

    Objective To investigate the application of modified adjustable skin stretching and secure wound-closure system in repairing of skin and soft tissue defect. Methods Between March 2016 and April 2017, 21 cases of skin and soft tissue defects were repaired with the modified adjustable skin stretching and secure wound-closure system (the size of regulating pressure and the times of adjustment were determined according to the color, temperature, capillary response, and swelling degree of the skin edge). There were 11 males and 10 females, with an average age of 49.2 years (range, 21-67 years). Among them, 1 case was the residual wound after amputation of leg; 18 cases were the wounds after traumatic injury operation, including 4 cases in the lower leg, 3 cases in the knee joint, 7 cases in the upper limb, and 4 cases in the foot; and 2 cases were diabetic feet. The skin defect area ranged from 4.0 cm×2.5 cm to 21.0 cm×10.0 cm. Results Skin defect wounds closed directly in one stage in 4 cases; 12 cases were closed after continuously stretching for 5-14 days (mean, 10 days); 5 cases were reduced to less than one-half area, and the wound healed after the second skin grafting or flap repairing. All the 21 patients were followed up 3-12 months (mean, 5.2 months). The wound was linear healing with small scar, and no invasive margin, poor blood flow, necrosis, and poor sensory function happened. Conclusion The modified adjustable skin stretching and secure wound-closure system can reduce the skin and soft tissue defects or close the wound directly, and even replace the skin graft and skin flap repairing. It was a good method for the treatment of skin and soft tissue defect.

    Release date:2017-12-11 12:15 Export PDF Favorites Scan
  • Application of skin stretching device in repair of diabetic foot wound

    ObjectiveTo evaluate the clinical value of skin stretching device in repair of diabetic foot wound.MethodsA retrospective analysis was made on the clinical data of 48 cases with diabetic foot wound who were treated with skin stretching device (trial group, n=24) and with the vacuum sealing drainage combined with skin graft (control group, n=24) respectively between October 2015 and July 2016. There was no significant difference in gender, age, side, course of disease, TEXAS stage between 2 groups (P>0.05). Both patients in 2 groups were treated with sensitive antibiotics according to the results of bacterial culture.ResultsOne case in control group was infected and the skin graft failed, and 1 case in trial group was infected after the treatment, and the two wounds healed after symptomatic treatment. The wounds of the other patients healed successfully, and the healing time of the trial group was significantly shorter than that of the control group [(12.8±11.6) days vs. (22.3±10.4) days; t=2.987, P=0.005). All patients were followed up 3-12 months after operation, and no wound dehiscence or recurrence occurred during follow-up.ConclusionCompared with the vacuum sealing drainage combined with skin graft, the application of skin stretching device in the repair of diabetic foot wound has advantages, such as easy to operate, shorten the wound healing time, and the appearance of wound was similar with the adjacent skin.

    Release date:2018-05-02 02:41 Export PDF Favorites Scan
  • Effect of cyclic stretch on expression of c-fos gene in rat Achilles-derived tendon stem cells

    Objective To investigate whether mechanical stretch stimulation affects the expression of the immediate early gene c-fos mRNA in rat Achilles-derived tendon stem cells (TSCs)in vitro. Methods TSCs were isolated from the Achilles tendons of 8 weeks old male Sprague Dawley rats by enzymatic digestion method and cultured for 3 passages. The TSCs were stimulated by a uniaxial cyclic stretching loading system under the condition of 1 Hz, respectively with 4% or 8% stretch intensity for 0, 5, 15, 30, 60, and 120 minutes. At each time point, TSCs were collected to detect c-fos mRNA expressions and to find the best time-point Tmax by real-time fluorescence quantitative PCR. Then, TSCs were simulated with 2%, 4%, 6%, 8%, or 12% stretch intensity for Tmax to observe the relative expressions of c-fos mRNA under different stretch intensities. Next, TSCs were stretched for 0, 5, or 15 minutes respectively and followed by incubation at relax status up to Tmax to observe the changes of c-fos mRNA expressions after short period stimulation. Finally, TSCs were stimulated with 4% or 8% stretch intensity respectively for 0, Tmax, or 120 minutes to detect the expressions of the tenogenic differentiation related genes [collagen type I, tenomodulin (TNMD)], the osteogenic differentiation related genes [runt related transcription factor 2 (Runx2), distal-less homeobox 5 (Dlx5)], and the adipogenic differentiation related gene [fatty acid binding protein 4 (FABP4)]. Results Under 4% or 8% stretch intensity, the relative expressions of c-fos mRNA significantly increased at 15 minutes (P<0.05), reached the maximum at 30 minutes (P<0.05), and returned to baseline at 60 minutes (P>0.05) when compared with expression at 0 minute. Therefore, Tmax was 30 minutes. The stretch intensity of 2% was enough to cause the expression of c-fos mRNA at 30 minutes, and the expression was significantly higher under the stretch intensity of 6%, 8%, and 12% than 2% and 4% (P<0.05). Even for a short period stimulation of 5 minutes, c-fos mRNA expression could still significantly increase at 30 minutes (P<0.05). The relative expressions of differentiation related genes at 30 and 120 minutes showed no significant difference when compared with the expression at 0 minute under 4% stretch intensity (P>0.05); but the relative expression of Runx2 gene significantly increased at 30 minutes, and the relative expressions of collagen type I, TNMD, Dlx5, and Runx2 increased at 120 minutes under 8% stretch intensity (P<0.05). Conclusion Mechanical stretch stimulation can affect the relative expression of the immediate early gene c-fos mRNA of rat Achilles-derived tendon stem cellsin vitro, and there is time- and intensity-dependence. It is suggested that the mechanical stimulation with different time or intensity may affect the differentiation of TSCs at early stage. This study is meaningful for the further study on TSCs intracellular mechanical signal transfer mechanism.

    Release date:2017-02-15 09:26 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content