west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "three-dimensional printing" 42 results
  • Utilization of Three-dimensional Printing Technology for Manufacture of Artificial Organs

    In this article, we introduce the principle, describe the utilization and discuss the future development of three-dimensional printing technology for manufacturing artificial organs.

    Release date: Export PDF Favorites Scan
  • Clinical study of three-dimensional printed navigation template assisted Ludloff osteotomy in treatment of moderate and severe hallux valgus

    ObjectiveTo explore the effectiveness and advantage of three-dimensional (3D) printed navigation templates assisted Ludloff osteotomy in treatment of moderate and severe hallux valgus.MethodsBetween April 2013 and February 2015, 28 patients (28 feet) with moderate and severe hallux valgus who underwent Ludloff osteotomy were randomly divided into 2 groups (n=14). In group A, the patients were treated with Ludloff osteotomy assissted with a 3D printed navigation template. In group B, the patients were treated with traditional Ludloff osteotomy. There was no significant difference in gender, age, affected side, and clinical classification between 2 groups (P>0.05). The operation time and intraoperative blood loss were recorded. The ankle function of the foot at preoperation, immediate after operation, and last follow-up were assessed by the American Orthopedic Foot and Ankle Society (AOFAS) score. Besides, the X-ray film were taken to assess the hallux valgus angle (HVA), intermetatarsal angle (IMA), and the first metatarsal length shortening.ResultsAll patients were followed up 18-40 months (mean, 26.4 months). The operation time and intraoperative blood loss in group A were significantly less than those in group B (P<0.05). The HVA, IMA, and AOFAS scores in groups A and B at immediate after operaton and last follow-up were sinificantly improved when compared with preoperative values (P<0.05); but no significant difference was found between at immediate after operation and at last follow-up (P>0.05). No significant difference was found in HVA and IMA between group A and group B at difference time points (P>0.05). There were significant differences in AOFAS score and the first metatarsal length shortening at immediate after operation and at last follow-up between 2 groups (P<0.05). Except 1 case of metastatic metatarsalgia in group B, there was no other operative complications in both groups.Conclusion3D printed navigation template assisted Ludloff osteotomy can provide accurate preoperative planning and intraoperative osteotomy. It is an ideal method for moderate and severe hallux valgus.

    Release date:2018-07-12 06:19 Export PDF Favorites Scan
  • Effectiveness of sacroiliac screw implantation assisted by three-dimensional printed faceted honeycomb guide plate in treatment of posterior pelvic ring fracture

    Objective To investigate the effectiveness of sacroiliac screw implantation assisted by three-dimensional (3D) printed faceted honeycomb guide plate in the treatment of posterior pelvic ring fracture. Methods The clinical data of 40 patients with posterior pelvic ring fractures treated with sacroiliac screw implantation between December 2019 and December 2022 were retrospectively analyzed. Among them, 18 cases were treated with sacroiliac screws fixation assisted by 3D printed faceted honeycomb guide plate (guide plate group), and 22 cases were treated with sacroiliac screws percutaneously fixation under fluoroscopy (conventional group). There was no significant difference in baseline data (P>0.05) such as gender, age, time from injury to operation, and Dennis classification between the two groups. The implantation time, frequency of C-arm X-ray fluoroscopy, frequency of guide pin adjustment of each sacroiliac screw, and postoperative complications and bone healing were recorded. Majeed score was used to evaluate the functional recovery at 6 months after operation, and CT was used to observe whether the screw penetrated the bone cortex. The deviation between the virtual position and the actual position of the screw tip, the sacral foramen, and the screw entry point was measured on the sagittal CT images of the guide plate group. Results The number of screws implanted in S1 and S2 vertebral bodies was 14 and 16 respectively in the guide plate group, and 17 and 18 respectively in the conventional group. The implantation time of each sacroiliac screw, the frequency of C-arm X-ray fluoroscopy, and the frequency of guide pin adjustment in S1, S2, and all vertebrae in the guide plate group were significantly less than those in the conventional group (P<0.05). Patients in both groups were followed up 8-48 months, with an average of 19.7 months. There was no incision infection, screw displacement, or internal fixation loosening in both groups. Callus growth was observed in all patients at 12 weeks after operation, and bone healing was achieved in all patients. The healing time ranged from 12 to 24 weeks, with an average of 15.7 weeks. No sacroiliac screw penetrated the bone cortex in the guide plate group; 2 patients in the conventional group had sacroiliac screws penetrating the bone cortex without damaging blood vessels or nerves. In the guide plate group, the deviation between the virtual position and the actual position of the screw tip, the sacral foramen, and the screw entry point were (2.91±1.01), (2.10±0.74), and (1.67±0.70) mm, respectively, with an average deviation of (2.19±1.22) mm. There was no significant difference in Majeed function evaluation between the two groups at 6 months after operation (P>0.05). Conclusion The application of 3D printed faceted honeycomb guide plate in sacroiliac screw implantation for posterior pelvic ring fracture can shorten the screw implantation time, reduce the frequency of fluoroscopy and guide pin adjustment, and reduce the risk of screw penetration through the bone cortex.

    Release date:2024-12-13 10:50 Export PDF Favorites Scan
  • The progress of research on three-dimensional printed jaw scaffolds

    Large defects of jaw caused by tumor, trauma and so on in oral and maxillofacial region lead to facial deformity, language and chewing dysfunction, which severely damage the patient’s life quality. Three-dimensional printing (3DP) is also named additive manufacturing (AM), which can print materials layer by layer to create three-dimensional objects. The complex shape of jaw defects can be accurately reconstructed using 3DP scaffold combined with image data, computer-aided-design and manufacture. It has specific advantages compared with traditional way of jaw reconstruction and has attracted much attention in the field of jaw tissue engineering recently. This article presented the progress of 3DP scaffold and its application in jaw reconstruction, providing a new idea for jaw reconstruction.

    Release date:2017-12-21 05:21 Export PDF Favorites Scan
  • Accuracy analysis and clinical application of the progressive navigation template system to assist atlas-axial pedicle screw placement

    ObjectiveTo investigate the accuracy of progressive three-dimensional navigation template system (abbreviated as progressive template) to assist atlas-axial pedicle screw placement. MethodsThe clinical data of 33 patients with atlas-axial posterior internal fixation surgery between May 2015 and May 2017 were retrospectively analyzed. According to the different methods of auxiliary screw placement, the patients were divided into trial group (19 cases, screw placement assisted by progressive template) and control group (14 cases, screw placement assisted by single navigation template system, abbreviated as initial navigation template). There was no significant difference in gender, age, cause of injury, damage segments, damage types, and preoperative Frankel classification between the two groups (P>0.05). The operation time and intraoperative blood loss of the two groups were compared. The safety of screw placement was evaluated on postoperative CT by using the method from Kawaguchi et al, the deviation of screw insertion point were calculated, the angular deviation of the nailing on coordinate systems XOZ, XOY, YOZ were calculated according to Peng’s method. ResultsAll patients completed the operation successfully; the operation time and intraoperative blood loss in the trial group were significantly less than those in the control group (t=–2.360, P=0.022; t=–3.006, P=0.004). All patients were followed up 12–40 months (mean, 25.3 months). There was no significant vascular injury or nerve injury aggravation. Postoperative immediate X-ray film and CT showed the dislocation was corrected. Postoperative immediate CT showed that all 76 screws were of grade 0 in the trial group, and the safety of screw placement was 100%; 51 screws were of grade 0, 3 of gradeⅠ, and 2 of gradeⅡ in the control group, and the safety of screw placement was 91.1%; there was significant difference in safety of screw placement between the two groups (χ2=7.050, P=0.030). The screw insertion point deviation and angular deviation of the nailing on XOY and YOZ planes in the trial group were significantly less than those in the control group (P<0.05). There was no significant difference in angular deviation of the nailing on XOZ between the two groups (t=1.060, P=0.290). ConclusionCompared with the initial navigation template, the progressive navigation template assisting atlas-axial pedicle screw placement to treat atlas-axial fracture with dislocation, can reduce operation time and intraoperative blood loss, improve the safety of screw placement, and match the preoperative design more accurately.

    Release date:2019-01-25 09:40 Export PDF Favorites Scan
  • Application of a new point contact pedicle navigation template as an auxiliary screw implant in scoliosis correction surgery

    ObjectiveTo explore the effectiveness of a new point contact pedicle navigation template (referred to as “new navigation template” for simplicity) in assisting screw implantation in scoliosis correction surgery. MethodsTwenty-five patients with scoliosis, who met the selection criteria between February 2020 and February 2023, were selected as the trial group. During the scoliosis correction surgery, the three-dimensional printed new navigation template was used to assist in screw implantation. Fifty patients who had undergone screw implantation with traditional free-hand implantation technique between February 2019 and February 2023 were matched according to the inclusion and exclusion criteria as the control group. There was no significant difference between the two groups (P>0.05) in terms of gender, age, disease duration, Cobb angle on the coronal plane of the main curve, Cobb angle at the Bending position of the main curve, the position of the apical vertebrae of the main curve, and the number of vertebrae with the pedicle diameter lower than 50%/75% of the national average, and the number of patients whose apical vertebrae rotation exceeded 40°. The number of fused vertebrae, the number of pedicle screws, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were compared between the two groups. The occurrence of implant complications was observed. Based on the X-ray films at 2 weeks after operation, the pedicle screw grading was recorded, the accuracy of the implant and the main curvature correction rate were calculated. ResultsBoth groups successfully completed the surgeries. Among them, the trial group implanted 267 screws and fused 177 vertebrae; the control group implanted 523 screws and fused 358 vertebrae. There was no significant difference between the two groups (P>0.05) in terms of the number of fused vertebrae, the number of pedicle screws, the pedicle screw grading and accuracy, and the main curvature correction rate. However, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were significantly lower in trial group than in control group (P<0.05). There was no complications related to screws implantation during or after operation in the two groups. ConclusionThe new navigation template is suitable for all kinds of deformed vertebral lamina and articular process, which not only improves the accuracy of screw implantation, but also reduces the difficulty of operation, shortens the operation time, and reduces intraoperative bleeding.

    Release date:2023-06-07 11:13 Export PDF Favorites Scan
  • Effectiveness analysis of three-dimensional printing assisted surgery for unstable pelvic fracture

    ObjectiveTo evaluate the effectiveness of three-dimensional (3D) printing assisted internal fixation for unstable pelvic fractures.MethodsThe clinical data of 28 patients with unstable pelvic fractures admitted between March 2015 and December 2017 were retrospectively analyzed. The patients were divided into two groups according to different surgical methods. Eighteen cases in the control group were treated with traditional anterior and posterior open reduction and internal fixation with plate; 10 cases in the observation group were treated with 3D printing technology to make pelvic models and assist in shaping the subcutaneous steel plates of the anterior ring. Sacroiliac screw navigation template was designed and printed to assist posterior ring sacroiliac screw fixation. There was no significant difference between the two groups in gender composition, age, cause of injury, fracture type, and time interval from injury to surgery (P>0.05). The operation time, intraoperative blood loss, intraoperative fluoroscopy times, incision length, waiting time for weight-bearing exercise, and fracture healing time were recorded and compared between the two groups. Majeed score was used to evaluate the function at last follow-up. At immediate after operation, the reduction was evaluated according to Matta imaging scoring criteria, and the success of sacroiliac joint screw implantation in the observation group was evaluated. The deviation of screw entry point and direction between postoperative screws and preoperative simulated screws were compared in the observation group.ResultsAll the operation was successfully completed, and all patients were followed up 6-18 months (mean, 14.4 months). In the control group, 1 case had wound infection and 2 cases had deep vein thrombosis. No serious complication such as important blood vessels, and nerve injury and pulmonary embolism occurred in other patients in the two groups. No screw pulling out or steel plate breaking occurred. The operation time, intraoperative blood loss, fluoroscopy times, incision length, and waiting time for weight-bearing exercise of the control group were significantly more than those of the observation group (P<0.05); there was no significant difference in fracture healing time between the two groups (t=0.12, P=0.90). There was no significant difference in reduction quality between the two groups at immediate after operation (Z=–1.05, P=0.30); Majeed score of the observation group was significantly better than that of the control group at last follow-up (Z=–2.42, P=0.02). The success rate of sacroiliac joint screw implantation in the observation group reached category Ⅰ. In the observation group, the deviation angle of the direction of the screw path between the postoperative screw and the preoperative simulated screw implant was (0.09±0.22)°, and the deviation values of the entry points on the X, Y, and Z axes were (0.13±0.63), (0.14±0.58), (0.15±0.53) mm, respectively. There was no significant difference when compared with those before the operation (all values were 0) (P>0.05).ConclusionComputer design combined with 3D printing technology to make personalized pelvic model and navigation template applied to unstable pelvic fractures, is helpful to accurately place sacroiliac screw, reduce the operation time, intraoperative blood loss, and the fluoroscopy times, has good waiting time for weight-bearing exercise and function, and it is an optional surgical treatment for unstable fractures.

    Release date:2019-05-06 04:46 Export PDF Favorites Scan
  • Clinical application of split three-dimensional printing patient-specific instrumentation in medial open-wedge high tibial osteotomy

    Objective To investigate the accuracy of split three-dimensional (3D) printing patient-specific instrumentation (PSI) in medial open-wedge high tibial osteotomy (MOWHTO) and its effectiveness in treating medial knee osteoarthritis.MethodsClinical data of 14 patients with medial knee osteoarthritis and treated with split 3D printing PSI-assisted MOWHTO between August 2019 and August 2020 were retrospectively analyzed. There were 5 males and 9 females with an average age of 61 years (range, 43-68 years). The disease duration ranged from 1 to 16 years, with an average of 4.7 years. Preoperative Kellgren-Lawrence grading of knee osteoarthritis included grade Ⅰ in 2 cases, grade Ⅱ in 6 cases, and grade Ⅲ in 6 cases. The Hospital for Special Surgery (HSS) score was 59.1±4.9. The weight bearing line ratio (WBL), hip-knee-ankle angle (HKA), medial proximal tibial angle (MPTA), posterior tibial slope angle (PTSA), and actual correction angle of the lower limbs were measured on postoperative imaging data, and compared with the preoperative measurements and the designed target values to evaluate the accuracy of the PSI-assisted surgery. The patients’ knee function were evaluated with the HSS score at 3 and 6 months postoperatively, and at last follow-up.ResultsOne patient suffered from an incision exudation at 2 weeks postoperatively, and the incision healed after symptomatic treatment. The incisions of other patients healed by first intention. All patients were followed up 7-19 months (mean, 14.8 months). There was no neural injuries, hinge fracture, plate or screw fractures, loosening, or other complications. The WBL was maintained at the postoperative level according to the X-ray examination during the follow-up period. The WBL, HKA, MPTA, and PTSA were all within a satisfactory range after operation. The WBL, HKA, and MPTA were significantly improved when compared with the preoperative measurements (P<0.05). There was no significant difference between preoperative and postoperative PTSA (P>0.05). The differences in postoperative WBL, HKA, MPTA, and correction angle compared with the preoperative designed target values were not significant (P>0.05). The HSS scores were 69.2±4.7, 77.7±4.3, and 88.1±5.4 at 3 and 6 months postoperatively, and last follow-up, respectively. The differences between time points were significant (P<0.05).ConclusionFor patients with medial knee osteoarthritis, the split 3D printing PSI can assist the surgeon in MOWHTO with accurate osteotomy orthopedics and achieve favorable effectiveness.

    Release date:2021-09-28 03:00 Export PDF Favorites Scan
  • Application of three-dimensional printed porous titanium alloy cage and poly-ether-ether-ketone cage in posterior lumbar interbody fusion

    Objective To compare the effectiveness between three-dimensional (3D) printed porous titanium alloy cage (3D Cage) and poly-ether-ether-ketone cage (PEEK Cage) in the posterior lumbar interbody fusion (PLIF). Methods A total of 66 patients who were scheduled to undergo PLIF between January 2018 and June 2019 were selected as the research subjects, and were divided into the trial group (implantation of 3D Cage, n=33) and the control group (implantation of PEEK Cage, n=33) according to the random number table method. Among them, 1 case in the trial group did not complete the follow-up exclusion study, and finally 32 cases in the trial group and 33 cases in the control group were included in the statistical analysis. There was no significant difference in gender, age, etiology, disease duration, surgical segment, and preoperative Japanese Orthopaedic Association (JOA) score between the two groups (P>0.05). The operation time, intraoperative blood loss, complications, JOA score, intervertebral height loss, and interbody fusion were recorded and compared between the two groups. Results The operations of two groups were completed successfully. There was 1 case of dural rupture complicated with cerebrospinal fluid leakage during operation in the trial group, and no complication occurred in the other patients of the two groups. All incisions healed by first intention. There was no significant difference in operation time and intraoperative blood loss between groups (P>0.05). All patients were followed up 12-24 months (mean, 16.7 months). The JOA scores at 1 year after operation in both groups significantly improved when compared with those before operation (P<0.05); there was no significant difference between groups (P>0.05) in the difference between pre- and post-operation and the improvement rate of JOA score at 1 year after operation. X-ray film reexamination showed that there was no screw loosening, screw rod fracture, Cage collapse, or immune rejection in the two groups during follow-up. At 3 months and 1 year after operation, the rate of intervertebral height loss was significantly lower in the trial group than in the control group (P<0.05). At 3 and 6 months after operation, the interbody fusion rating of trial group was significantly better in the trial group than in the control group (P<0.05); and at 1 year after operation, there was no significant difference between groups (P>0.05). ConclusionThere is no significant difference between 3D Cage and PEEK Cage in PLIF, in terms of operation time, intraoperative blood loss, complications, postoperative neurological recovery, and final intervertebral fusion. But the former can effectively reduce vertebral body subsidence and accelerate intervertebral fusion.

    Release date:2022-09-30 09:59 Export PDF Favorites Scan
  • Application effect evaluation of reverse digital modeling combined with three-dimensional printed disease models in standardized clinical training and teaching of pelvic tumor

    Objective To evaluated the application effect of reverse digital modeling combined with three-dimensional (3D)-printed disease models in the standardized training of orthopedic residents focusing on pelvic tumors. Methods From August 2022 to August 2023, 60 orthopedic residents from West China Hospital, Sichuan University were randomly assigned to a trial group (n=30) and a control group (n=30). The trial group received instruction using reverse digital modeling and 3D-printed pelvic tumor models, while the control group underwent traditional teaching methods. Teaching outcomes were evaluated and compared between groups through knowledge tests, practical skill assessments, and satisfaction surveys. Results Before training, there was no statistically significant difference in knowledge tests or practical skill assessments between the two groups (P>0.05). After training, the trial group showed significantly better performance than the control group in knowledge tests (90.5±5.2 vs. 78.4±6.8, P<0.05), skill assessments (92.7±4.9 vs. 81.3±6.2, P<0.05), and satisfaction surveys (9.40±1.10 vs. 7.60±1.20, P<0.05). One month after training, the trial group still showed significantly better performance than the control group in knowledge tests (88.1±6.4 vs. 72.3±7.1, P<0.05) and skill assessments (90.3±5.8 vs. 75.6±6.9, P<0.05). Conclusions Reverse digital modeling combined with 3D printing offers an intuitive and effective teaching approach that improves comprehension of pelvic tumor anatomy and strengthens clinical and technical competencies. This method significantly enhances learning outcomes in standardized residency training and holds promise for broader integration into medical education.

    Release date:2025-05-26 04:29 Export PDF Favorites Scan
5 pages Previous 1 2 3 4 5 Next

Format

Content