west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "tibial plateau" 17 results
  • Efficacy and safety of multiple-dose intravenous tranexamic acid for reducing blood loss in complex tibial plateau fractures: A prospective randomized controlled trial

    ObjectiveTo investigate the efficacy and safety of multiple-dose intravenous tranexamic acid (TXA) for reducing blood loss in complex tibial plateau fractures with open reduction internal fixation by a prospective randomized controlled trial. MethodsA study was conducted on patients with Schatzker type Ⅳ-Ⅵ tibial plateau fractures admitted between August 2020 and December 2022. Among them, 88 patients met the selection criteria and were included in the study. They were randomly allocated into 3 groups, the control group (28 cases), single-dose TXA group (31 cases), and multiple-dose TXA group (29 cases), using a random number table method. There was no significant difference (P>0.05) in terms of age, gender, body mass index, the Schatzker type and side of fracture, laboratory examinations [hemoglobin (Hb), activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fib), international normalized ratio (INR), D-dimer, and interleukin 6 (IL-6)], and preoperative blood volume. The control group received intravenous infusion of 100 mL saline at 15 minutes before operation and 3, 6, and 24 hours after the first administration. The single-dose TXA group received intravenous infusion of 1 g TXA (dissolved in 100 mL saline) at 15 minutes before operation, followed by an equal amount of saline at each time point after the first administration. The multiple-dose TXA group received intravenous infusion of 1 g TXA (dissolved in 100 mL saline) at each time point. The relevant indicators were recorded and compared between groups to evaluate the effectiveness and safety of TXA, including hospital stays, operation time, occurrence of infection; the occurrence of lower extremity deep vein thrombosis, intermuscular vein thrombosis, and pulmonary embolism at 1 week after operation; the lowest postoperative Hb value and Hb reduction rate, the difference (change value) between pre- and post-operative APTT, PT, Fib, and INR; D-dimer and IL-6 at 24 and 72 hours after operation; total blood loss, intraoperative blood loss, hidden blood loss, drainage flow during 48 hours after operation, and postoperative blood transfusion. Results ① TXA efficacy evaluation: the lowest Hb value in the control group was significantly lower than that in the other two groups (P<0.05), and there was no significant difference between the single- and multiple-dose TXA groups (P>0.05). The Hb reduction rate, total blood loss, intraoperative blood loss, drainage flow during 48 hours after operation, and hidden blood loss showed a gradual decrease trend in the control group, single-dose TXA group, and multiple-dose TXA group. And differences were significant (P<0.05) in the Hb reduction rate and drainage flow during 48 hours after operation between groups, and the total blood loss and hidden blood loss between control group and other two groups. ② TXA safety evaluation: no lower extremity deep vein thrombosis or pulmonary embolism occurred in the three groups after operation, but 3, 4, and 2 cases of intermuscular vein thrombosis occurred in the control group, single-dose TXA group, and multiple-dose TXA group, respectively, and the differences in the incidences between groups were not significant (P>0.05). There was no significant difference in the operation time between groups (P>0.05). But the length of hospital stay was significantly longer in the control group than in the other groups (P<0.05); there was no significant difference between the single- and multiple-dose TXA groups (P>0.05). ③ Effect of TXA on blood coagulation and inflammatory response: the incisions of the 3 groups healed by first intention, and no infections occurred. The differences in the changes of APTT, PT, Fib, and INR between groups were not significant (P>0.05). The D-dimer and IL-6 in the three groups showed a trend of first increasing and then decreasing over time, and there was a significant difference between different time points in the three groups (P<0.05). At 24 and 72 hours after operation, there was no significant difference in D-dimer between groups (P>0.05), while there was a significant difference in IL-6 between groups (P<0.05). Conclusion Multiple intravenous applications of TXA can reduce perioperative blood loss and shorten hospital stays in patients undergoing open reduction and internal fixation of complex tibial plateau fractures, provide additional fibrinolysis control and ameliorate postoperative inflammatory response.

    Release date:2023-09-07 04:22 Export PDF Favorites Scan
  • Correlation study on the influencing factors of semitendinosus insertion location

    Objective To investigate the relationship between the vertical distance from semitendinosus insertion to tibial plateau (S-T) and the physical characteristics of patients, in order to provide reference for incision design to expose the semitendinosus insertion. Methods The patients with ligament injury who underwent primary anterior cruciate ligament reconstruction between January 2022 and December 2022 were selected as the research subjects. The patients’ baseline data were collected, including age, gender, height, and body mass. During reconstruction operation, the S-T was measured. Considering the S-T as the dependent variable and baseline data as the independent variable, multiple linear regression analysis was used to establish a regression equation to determine the possible influencing factors of semitendinosus insertion location. Results According to the selection standard, a total of 214 patients were enrolled, including 156 males and 58 females, aged (27±9) years (14-49 years), with a height of (174.7±6.8) cm (range, 160-196 cm) and a body mass of (73.43±12.35) kg (range, 53-105 kg). The S-T was (56.36±3.61) mm (range, 47-67 mm). The multiple linear regression analysis results showed that the height was positively correlated with S-T (β=0.407, SE=0.055, t=7.543, P<0.001); the regression equation was S-T=−14.701+0.407×height, R2=0.690. ConclusionThere was a linear relationship between the height and semitendinosus insertion. The location of semitendinosus insertion estimated by the formula (S-T=−14.701+0.407×height) is reasonable, which provides a theoretical basis for rapid, accurate, and safe location of semitendinosus insertion and design of surgical incision in clinic.

    Release date:2023-08-09 01:37 Export PDF Favorites Scan
  • Treatment of posterolateral tibial plateau fractures with a novel lateral tibial plateau annular plate via fibular neck osteotomy approach

    Objective To investigate the effectiveness of a novel lateral tibial plateau annular plate (hereinafter referred to as the novel plate) fixation via fibular neck osteotomy approach for posterolateral tibial plateau fractures. Methods Between January 2015 and December 2018, 22 patients with posterolateral tibial plateau fractures were treated. There were 10 males and 12 females with an average age of 39.0 years (range, 25-56 years). Seven fractures were caused by falls, 10 by traffic accidents, and 5 by falling from height. The time from injury to hospitalization ranged from 3 to 12 days, with an average of 7.0 days. All patients were closed fractures. According to Schatzker classification, the fractures were classified as type Ⅱ in 8 cases, type Ⅲ in 9 cases, type Ⅴ in 1 case, and type Ⅵ in 4 cases. The fractures were fixed with the novel plates after reduction via fibular neck osteotomy approach. The fracture reduction and healing were observed by X-ray film after operation. The range of motion of the knee joint was recorded and the function was evaluated by modified American Hospital for Special Surgery (HSS) score. Results All operations were completed successfully. The operation time was 60-95 minutes (mean, 77.6 minutes). The intraoperative blood loss was 100-520 mL (mean, 214.5 mL). There was 1 case of common peroneal nerve injury during operation and 2 cases of fat liquefaction of incision after operation. All patients were followed up 13-32 months (mean, 19.4 months). Postoperative X-ray films showed that the fracture reduction was good in 17 cases and moderate in 5 cases, and all fractures healed with a healing time of 10-18 weeks (mean, 13.0 weeks). At last follow-up, the range of motion of the knee joint ranged from 100° to 145° in flexion (mean, 125.5°) and from 0° to 4° in extension (mean, 1.2°). The modified HSS score was 82-95 (mean, 86.3). There was no complications such as plate deformation, screw fracture, fracture reduction loss, skin necrosis, and so on. Conclusion For posterolateral tibial plateau fractures, the novel plate fixation via fibular neck osteotomy approach has the advantages of clear intraoperative field, firm fracture fixation, and less postoperative complications, which is beneficial to the recovery of knee joint function.

    Release date:2022-09-30 09:59 Export PDF Favorites Scan
  • Evaluation and diagnosis of knee joint diagonal lesion and surgical strategy and effectiveness

    Objective To investigate the evaluation, diagnosis, and surgical treatment of knee joint diagonal lesion and to observe its effectiveness. Methods A retrospective analysis was performed on 9 patients with knee joint diagonal lesion admitted between November 2011 and November 2019, including 7 males and 2 females, aged 18-61 years, with an average age of 38.3 years. According to the clinical staging criteria of multiple ligament injury of knee joint, 6 patients with acute stage injury (≤3 weeks), the time from injury to operation was 5-16 days, with an average of 9.3 days; 3 patients with old stage injury (>3 weeks), the time from injury to operation was 7, 12, 144 months, respectively. Posterolateral complex injuries were all type C according to Fanelli classification, and the posterior cruciate ligament injury was grade 3 according to American Medical Association (AMA) classification. According to the three columns classification of tibial plateau fracture, there were 2 cases of zero column fracture and 7 cases of medial column fracture. Patients with acute injury were treated with posterior cruciate ligament reconstruction, posterolateral complex repair and/or reinforcement reconstruction, and tibial plateau fracture was treated with conservative treatment or internal fixation. Patients with malunion of tibial plateau in old stage were treated with limited osteotomy, bone grafting, and internal fixation; the stability of the knee joint was further evaluated during operation, then the posterior cruciate ligament reconstruction and/or posterolateral complex repair and reconstruction were performed as needed. Lysholm score and the International Knee Documentation Committee (IKDC) score before and after operation were used to evaluate knee function and effectiveness. Results All patients were followed up 24-119 months, with an average of 51.7 months. All the incisions healed by first intention, and no complication such as incision infection, deep venous thrombosis of lower extremities occurred, and there was no reoperation during follow-up. The full-length X-ray films of both lower extremities at 6 months and 1, 2 years after operation showed that the alignment of both lower extremities returned to normal, and the stress position X-ray films showed that the stability in all directions recovered well. The X-ray films of the knee joint at 6 months after operation showed that the fracture of the tibial plateau healed well. At 1 year after operation, MRI showed that the signal of the repaired and reconstructed ligament was good, and there was no reconstruction failure such as ligament absorption or rupture occurred. At 1 year after operation, the muscle strength of the affected limbs was all rated as grade Ⅴ, and the active and passive range of motion of the knee joint recovered to 0°-130°. At 2 years after operation, the Lysholm score and IKDC score significantly improved when compared with those before operation (P<0.05). Conclusion Knee joint diagonal lesion is a special type of posterior cruciate ligament and posterolateral complex injury with anteromedial split and collapse fracture of tibial plateau, which requires correct evaluation and diagnosis of the injured structure, and detailed surgical and rehabilitation programs to achieve better effectiveness.

    Release date:2022-09-30 09:59 Export PDF Favorites Scan
  • Biomechanical study of nickel-titanium three-dimensional memory alloy mesh and autologous bone in treatment of canine tibial plateau collapse fracture

    ObjectiveTo evaluate the biomechanical effect of a nickel-titanium (Ni-Ti) three-dimensional memory alloy mesh in treating a canine tibial plateau collapse fracture model and to lay a foundation for further experiments in vivo.MethodsSixteen tibial plateau specimens of 8 adult Beagle dogs were harvested. Twelve specimens were taken to prepare canine tibial plateau collapse fracture models (Schatzker type Ⅲ) and randomly divided into groups A, B, and C, with 4 specimens in each group. Four normal tibia specimens were used as blank control group (group D). In groups A and B, the bone defects were repaired with Ni-Ti three-dimensional shape memory alloy mesh combined with autologous bone and simple autologous bone respectively, and fixed with the lateral plate and screw. In group C, the bone defect was directly fixed with the lateral plate and screw. By using a biomechanical tester, a progressive load (0-1 700 N) was loaded vertically above the femoral condyle. The maximum failure load was recorded and the stiffness was calculated according to the load-displacement curve.ResultsThe maximum failure loads in groups A, B, C, and D were (1 624.72±7.02), (1 506.57±3.37), (1 102.00±1.83), and (1 767.64±24.56) N, respectively; and the stiffnesses were (129.72±20.83), (96.54±27.05), (74.96±17.70), and (169.01±35.62) N/mm, respectively. The maximum failure load and stiffness in group A were significantly higher than those in groups B and C, but which were significantly lower than those in group D (P<0.05).ConclusionNi-Ti three-dimensional memory alloy mesh combined with autologous bone can repair the Schatzker type Ⅲ tibial plateau collapse fracture, which has better biomechanical properties than simple autologous bone grafting.

    Release date:2018-05-30 04:28 Export PDF Favorites Scan
  • Posterolateral minimal incision, poking reduction, and simple internal fixation in treatment of collapsed fractures of posterolateral tibial plateau

    Objective To explore the effectiveness of limited incision, poking reduction, and simple internal fixation in the treatment of collapsed fractures of the posterolateral tibial plateau. Methods Between October 2010 and January 2016, 16 patients with collapsed fractures of the posterolateral tibial plateau underwent posterolateral incision, poking reduction, and simple internal fixation. There were 10 males and 6 females with the age of 22-63 years (mean, 43.5 years). The injury was caused by falling in 5 cases, traffic accident in 7 cases, and falling from height in 4 cases. All cases had closed fractures. The left knee was involved in 9 cases and the right knee in 7 cases. The injury-to-admission time was 2 hours to 3 days (mean, 10 hours). X-ray films showed that the articular surface collapsing was more than 2 mm. According to Schatzker criteria, 6 cases were rated as type II and 10 cases as type III. Twelve cases had fracture of fibular head. The incision length, operation time, intraoperative blood loss, and incision healing were recorded; fracture healing was observed, and tibial plateau angle and posterior slope angle were measured on X-ray films; loss of articular surface reduction was observed by CT scan; and American Hospital for Special Surgery (HSS) score was used to evaluate the knee joint function. Results The incision length was 7-10 cm (mean, 8.6 cm); operation time was 35-55 minutes (mean, 46 minutes); intraoperative blood loss was 10-35 mL (mean, 28 mL). Primary healing of incision was obtained. Skin pain occurred in 1 case at 2 months because Kirschner wire retracted. Fifteen cases were followed up 8-21 months (mean, 13.5 months). The fracture healing time was from 3 to 6 months (mean, 4.8 months). There was no significant difference in tibial plateau angle and posterior slope angle between at immediate after operation and at last follow-up (t=–1.500, P=0.156; t=–1.781, P=0.097). The anatomic reduction rate of articular surface was 93.8% (15/16) at immediate after operation. At last follow-up, the recollapse height of articular surface was 0.1-1.2 mm (mean, 0.36 mm). According to the HSS score system, the results were excellent in 12 cases, good in 2 cases, and fair in 1 case, and the excellent and good rate was 93.3%. Conclusion The limited incision by posterolateral approach, poking reduction, and simple internal fixation have the advantages of small injury, full exposure, and easy operation in the treatment of simple posterolateral tibial plateau fractures; bone graft support and simple internal fixation can prevent recollapse of the articular surface and achieve satisfactory knee function.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
  • Effectiveness analysis of Zhang’s double reverse traction reducer in minimally invasive treatment of bilateral tibial plateau fractures

    Objective To evaluate the effectiveness and safety of minimally invasive treatment for bilateral tibial plateau fractures using the double reverse traction reducer. Methods The clinical data of 4 patients with bilateral tibial plateau fractures who met the selection criteria and treated between January 2016 and April 2024 were retrospectively analyzed. The cohort included 3 males and 1 female, aged 30-65 years (mean, 52.5 years). Injury mechanisms comprised traffic accidents (2 cases) and falls (2 cases). According to the Schatzker classification, 2 limbs were type Ⅱ and 6 were type Ⅵ. The time from injury to surgery ranged from 5 to 9 days (mean, 7 days). All patients underwent minimally invasive reduction using the double reverse traction reducer. Surgical duration, intraoperative blood loss, and hospitalization time were recorded. Functional outcomes were assessed at last follow-up using the Hospital for Special Surgery (HSS) knee score and range of motion (ROM), while fracture reduction quality was evaluated using the Rasmussen radiological score. Results All 4 patients successfully completed the procedure without conversion to open reduction. The total mean operation time was 80.25 minutes (range, 73-86 minutes), with a mean total intraoperative blood loss of 132.5 mL (range, 100-150 mL). The mean hospitalization time was 13.5 days (range, 11-16 days). All incisions healed primarily without neurovascular complications. X-ray film at 1 day after operation confirmed satisfactory reduction and articular surface alignment. Follow-up time ranged from 12 to 26 months (mean, 17.0 months). Fractures achieved clinical union at an average of 13 weeks (range, 12-16 weeks). No complication, such as deep vein thrombosis, joint stiffness, post-traumatic arthritis, or implant failure, was observed. At last follow-up, the mean HSS score was 92.9 (range, 90-97), mean knee ROM was 128.1° (range, 115°-135°), and mean Rasmussen radiological score was 16.4 (range, 15-19), with 2 limbs rated as excellent and 6 as good. Conclusion The double reverse traction reducer facilitates minimally invasive treatment of bilateral tibial plateau fractures with advantages including minimal trauma, shorter surgical duration, precise reduction, and fewer complications, effectively promoting fracture healing and functional recovery of the knee joint.

    Release date: Export PDF Favorites Scan
  • Application of modified anterolateral supra-fibular-head approach in treatment of tibial plateau fractures involving posterolateral column

    ObjectiveTo explore effectiveness of reduction and internal fixation via modified anterolateral supra-fibular-head approach in treatment of tibial plateau fractures involving posterolateral column.MethodsBetween January 2016 and September 2018, 19 patients diagnosed as tibial plateau fractures involving posterolateral column were treated with reduction and internal fixation via modified anterolateral supra-fibular-head approach. There were 11 males and 8 females with an average age of 43.2 years (range, 28-65 years). The causes of tibial fracture were traffic accident (12 patients), falling injury (5 patients), and falling from height (2 patients). According to the Schatzker typing, the tibial fractures were rated as type Ⅱ in 9 cases, type Ⅲ in 4 cases, type Ⅴ in 4 cases, and type Ⅵ in 2 cases. The time from injury to operation was 5-13 days (mean, 8.5 days). There were 2 patients with osteoporosis. The operation time, intraoperative blood loss, and postoperative complications were recorded. The knee X-ray film was reviewed regularly to observe the fracture healing. At last follow-up, the fracture reductions were evaluated by Rasmussen radiological score. The knee joint function was evaluated by Hospital for Special Surgery (HSS) score system.ResultsThe average operation time was 95 minutes (range, 65-130 minutes). The average intraoperative blood loss was 220 mL (range, 150-350 mL). All incisions healed by first intention. No complications such as infection or deep venous thrombosis occurred. All patients were followed up 12-20 months (mean, 15.4 months). X-ray films showed that the fractures healed with the healing time of 12-20 weeks (mean, 14.5 weeks). No complications such as loosening or breakage of internal fixation occurred. At last follow-up, according to the Rasmussen radiological score, the fracture reductions were evaluated as excellent in 13 cases, good in 4 cases, fair in 1 case, and poor in 1 case. HSS scores of knee joint function were excellent in 14 cases, good in 3 cases, fair in 1 case, and poor in 1 case. The knee joint range of motion was 90°-135°, with an average of 113.4°.ConclusionApplication of modified anterolateral supra-fibular-head approach in reduction and internal fixation for tibial plateau fractures involving posterolateral column has the advantages of full exposure, less trauma, safety, and reliable reduction and fixation.

    Release date:2020-07-07 07:58 Export PDF Favorites Scan
  • Application of Allgöwer-Donati suture in internal fixation of Schatzker type Ⅴand Ⅵ tibial plateau closed fractures

    Objective To investigate the effectiveness of Allgöwer-Donati suture in open reduction and internal fixation of Schatzker type Ⅴ and Ⅵ tibial plateau closed fractures. Methods A clinical data of 60 patients with Schatzker type type Ⅴ and Ⅵ tibial plateau closed fractures, who met the selection criteria and admitted between May 2022 and May 2023, was retrospectively analyzed. After open reduction and internal fixation via double incisions, the incisions were closed with conventional mattress suture in 30 cases (control group) and Allgöwer-Donati suture in 30 cases (observation group). There was no significant difference in gender, age, fracture side and type, time from injury to operation, body mass index, and other baseline data between the two groups (P>0.05). The incidence of incision-related complications after operation, visual analogue scale (VAS) score of incision at 3 days and 1 and 2 weeks after operation, and the short-form 36 health survey scale (SF-36) [physical functioning (PF), role physical (RP), bodily pain (BP), and general health (GH)] at 12 weeks after operation were compared between the two groups. Results All operations of the two groups successfully completed. All patients were followed up 6-14 months (mean, 12 months). Incision fluid leakage occurred in 1 case of observation group and 7 cases of control group within 1 week after operation, and the incisions healed after symptomatic treatment. The incisions of other patients healed by first intention. The incidence of early incision complications in observation group was significantly lower than that in control group (P<0.05). No late incision complications was found in the two groups. There was no significant difference in VAS scores at each time point between the two groups (P>0.05). The VAS score significantly decreased with the increase of time in the two groups, showing significant differences between the different time points (P<0.05). There was no significant difference in SF-36 scores (PF, RP, BP, and GH) between the two groups at 12 weeks after operation (P>0.05). Conclusion Compared with conventional mattress suture, Allgöwer-Donati suture is effective in open reduction and internal fixation via double incisions for Schatzker type Ⅴand Ⅵ tibial plateau closed fractures, which can reduce the incidence of early incision complications.

    Release date:2024-06-14 09:52 Export PDF Favorites Scan
  • CORRECTION OF VARUS KNEE WITH REDUCTION OSTEOTOMY DURING TOTAL KNEE ARTHROPLASTY

    ObjectiveTo evaluate the effectiveness of reduction osteotomy for correction of varus knee during total knee arthroplasty. MethodsA retrospective analysis was made on the clinical data of 16 patients (24 knees) who received reduction osteotomy for correcting varus knee during total knee arthroplasty between May 2010 and July 2012. There were 2 males (3 knees) and 14 females (21 knees), with an average age of 67 years (range, 57-79 years). The disease duration ranged from 3 to 15 years (mean, 9.1 years). The Knee Society Score (KSS) was 38.71±10.04 for clinical score and 50.31±14.31 for functional score. The range of motion (ROM) of the knee was (91.88±13.01)°. The tibiofemoral angle was (9.04±4.53)° of varus deformity. Reduction osteotomy was applied to correct varus knee. ResultsThe operation time was 85-245 minutes (mean, 165.5 minutes); the obvious blood loss was 10-800 mL (mean, 183.1 mL); the hospitalization time was 8-22 days (mean, 13.6 days). All incisions healed by first intention. No neurovascular injury or patellar fracture occurred. The follow-up duration ranged from 37 to 62 months (mean, 48 months). The tibiofemoral angle was corrected to (3.92±1.89)° of valgus at 48 hours after operation. The lower limb alignment recovered to normal. The X-ray films showed no evidence of obvious radiolucent line, osteolysis, or prosthesis subsidence. The results of KSS were significantly improved to 84.21±6.49 for clinical score and 85.31±6.95 for functional score (t=20.665, P=0.000; t=9.585, P=0.000); and ROM of the knee was significantly increased to (105.83±11.29)° (t=8.333, P=0.000) at last follow-up. ConclusionThe effectiveness of reduction osteotomy for varus knee deformity during total knee arthroplasty is satisfactory. Proper alignment, ROM, and function of knee can be achieved.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content