find Keyword "valve disease" 38 results
  • Detection method of early heart valve diseases based on heart sound features

    Heart valve disease (HVD) is one of the common cardiovascular diseases. Heart sound is an important physiological signal for diagnosing HVDs. This paper proposed a model based on combination of basic component features and envelope autocorrelation features to detect early HVDs. Initially, heart sound signals lasting 5 minutes were denoised by empirical mode decomposition (EMD) algorithm and segmented. Then the basic component features and envelope autocorrelation features of heart sound segments were extracted to construct heart sound feature set. Then the max-relevance and min-redundancy (MRMR) algorithm was utilized to select the optimal mixed feature subset. Finally, decision tree, support vector machine (SVM) and k-nearest neighbor (KNN) classifiers were trained to detect the early HVDs from the normal heart sounds and obtained the best accuracy of 99.9% in clinical database. Normal valve, abnormal semilunar valve and abnormal atrioventricular valve heart sounds were classified and the best accuracy was 99.8%. Moreover, normal valve, single-valve abnormal and multi-valve abnormal heart sounds were classified and the best accuracy was 98.2%. In public database, this method also obtained the good overall accuracy. The result demonstrated this proposed method had important value for the clinical diagnosis of early HVDs.

    Release date:2023-12-21 03:53 Export PDF Favorites Scan
  • Tricuspid Valve Replacement: A Report of 13 Cases

    Abstract: Objective To summarize the clinical experience of 13 patients of tricuspid valve replacement and to investigate the indication and method. Methods From January 1994 to December 2005, the clinical datum of the thirteen patients suffering from tricuspid valve disease were reviewed, including rheumatic heart disease 6 cases, congenital heart disease 3 cases, infective endocarditis 3 cases and right ventricular tumor 1 case. All the cases underwent tricuspid valve replacement. Results Two reoperative rheumatic heart disease patients died early after operation and their cardiac function was New York Heart Association (NYHA) class Ⅳ before operation. The followup interval was 3 months to 12 years in 11 cases. There were 2 late death, one died of recurrence of infective endocarditis, and another died of the recurrence of the tumor. One Ebstein anomaly case’s NYHA functional recovered to class Ⅲ, eight cases’s recovered to NYHA classⅠ-Ⅱ. Conclusion The tricuspid valve disease may be a secondary lesion from many causes. Indication of tricuspid valve replacement must be strictly commanded. The late results of tricuspid valve mechanical prostheses replacement is satisfactory.

    Release date:2016-08-30 06:13 Export PDF Favorites Scan
  • Current Clinical Application of Ross Procedure

    Abstract:The use of pulmonary autograft was first reported in 1967 by Ross for the treatment of aortic valve disease in adults. Since that time, Ross procedure has been applied to a variety of forms of aortic stenosis and left ventricular outflow tract obstruction and mitral valve disease, Ross procedure has undergone several modifications, such as the root replacement method, inclusion cylinder technique, annular reduction, Konno root enlargement procedures and replacement of the mitral valve with a pulmonary autograft (Ross-Kabbani procedure or Ross Ⅱ procedure). Advantages of Ross procedure in women of childbearing age, children and young adults include freedom from anticoagulation, appropriate sizing, cellular viability with growth potential proportional to somatic growth, acceptable long-term durability, excellent hemodynamic performance and decreased susceptibility to endocarditis. Surgical technical aspects, indications, selection criteria for the Ross procedure and its modifications, their applicability in the surgical management of aortic stenosis, left ventricular outflow tract obstruction and mitral valve disease and clinical outcome of Ross procedure are reviewed in this article.

    Release date:2016-08-30 06:23 Export PDF Favorites Scan
  • Effect of pulmonary hypertension on clinical efficacy of Cox Maze Ⅳ procedure in treating atrial fibrillation patients with valvular heart disease: A retrospective cohort study

    ObjectiveTo explore the effect of pulmonary hypertension on the clinical efficacy of Cox Maze Ⅳ procedure in treating atrial fibrillation (AF) patients with valvular heart disease.MethodsThe clinical data of 84 patients who received cardiac valve replacement and Cox Maze Ⅳ ablation in our hospital from July 2017 to January 2020 were retrospectively analyzed. According to the estimation of pulmonary artery pressure (PAP) by ultrasound, the patients were divided into two groups: a group A (PAP<45 mm Hg, 20 males, 26 females with an average age of 59.1±7.8 years) and a group B (PAP≥45 mm Hg, 15 males and 23 females with an average age of 58.5±8.5 years). The PAP was less than 70 mm Hgin all patients. A systematic follow-up review was performed for 6 months after operation. The recovery and recurrence rate of sinus rhythm after surgical ablation were compared between the two groups, and the efficacy was analyzed.Results(1) All the patients completed the operation successfully, and there was no statistical difference in the ablation time between the two groups (P>0.05); no patients died of pulmonary infection after the operation, and one patient underwent implantation of a permanent pacemaker due to conduction block. (2) At the end of the operation and 3 months after the operation, the conversion rate of AF in the group A was 91.3% (42 patients) and 82.6% (38 patients), respectively, and in the group B was 89.5% (34 patients) and 73.7% (28 patients), respectively (P>0.05). The conversion rate of AF was 82.6% (38 patients) in the group A and 63.2% (24 patients) in the group B at 6 months after operation (P=0.043). Binary logistic regression analysis showed that PAP≥45 mm Hg had a significant effect on the long-term effect of surgical Maze procedure in treating AF patients with valvular heart disease [P=0.014, OR=5.661, 95%CI (1.429, 22.432)].ConclusionPAP may be an influencing factor for the long-term effect of surgical Maze procedure in treating AF patients with valvular heart disease. Although the long-term recurrence rate of AF in the moderate pulmonary hypertension group is higher than that in the group A, the overall effect is still safe and effective; therefore it is still worth promoting in clinical application.

    Release date:2021-12-27 11:31 Export PDF Favorites Scan
  • Novel Modified Epicardial Radiofrequency Ablation for Preoperative Atrial Fibrillation Combined with Aortic Valve Disease

    ObjectiveTo assess the effect of a novel modified epicardial radiofrequency (RF) ablation for preoperative atrial fibrillation (AF) combined with aortic valve disease. MethodsWe retrospectively analyzed the clinical data of 28 patients with AF and aortic valve disease underwent the novel modified epicardial RF ablation combined with aortic valve replacement (AVR) in our hospital between December 2009 and December 2014. There were 18 males and 10 females at age of 53-73 (64.9±4.8) years. The patients were performed epicardial atrial fibrillation RF ablation plus aortic valve replacement. ResultsThe modified epicardial RF ablation and AVR were performed successfully in all the patients. The maintenance of sinus rhythm was 96.4% (27/28) at discharge. There were no early death and permanent pacemaker implantation in perioperation. At a mean following-up of 29.2±17.7 months, 26 of 28 (92.9%) patients were in sinus rhythm. Following-up transthoracic echocardiography(TTE) at 6 months postoperatively showed that left atrial diameter was significantly reduced and left ventricular ejection fraction was significantly increased. ConclusionThe novel modified epicardial RF ablation procedure is safe, feasible, and effective. It may be useful in selecting the best ablation approaches for patients with AF and aortic valve disease.

    Release date:2016-10-02 04:56 Export PDF Favorites Scan
  • Clinical Analysis of Surgical Treatment of NonIschemic Heart Valve Disease Combined with Coronary Artery Disease 

    Objective To summarize the outcomes and clinical features for surgical treatment of nonischemic heart valve disease(HVD) combined with coronary artery disease(CAD), so that to get better surgical result. Methods From January 2000 to June 2007, 105 patients with the mean age of 61.96±7.61 years (range 36-79 years), underwent the combined procedures.The etiology of HVD included: 59 rheumatic valve disease, 24 degenerative mitral lesion, 13 calcified aortic valve lesion, and 9 other aortic valve disease. CAD was preoperatively diagnosed by coronary arteriongraphy in 98 patients, and intraoperatively identified in 7 patients. Left ventricular ejection fraction was 50% or less in 45 patients. The total number of bypass grafts was 216 with the mean of 2.06 grafts per patient. Valve procedures included: 36 mitral valve valve replacement, 15 mitral repair,43 aortic valve replacement, 11 mitral valve and aortic valve replacement. Results There were 6 postoperative deaths with the mortality of 5.7%. The causes of death were 3 low cardiac output syndrome, 2 renal failure, and 1 heart arrest resulting in multiple organs failure. Ninety-three survivals were followed up from 1 month to 7 years, 6 patients were missed on follow-up. There were no late death. New York Heart Association class Ⅰ was observed in 25 patients, class Ⅱ53, class Ⅲ 10 and class Ⅳ 5. One patient still had existential chest pain. Conclusion There were no typical angina in majority of patients with nonischemic HVD combined with CAD, coronary arteriongraphy must be taken in patients with the age of 50 years and more, or with the risk factors for CAD.Intraoperative myocardial protection is very important because CAD further deteriorates myocardial dysfunction caused by HVD.The decreased left ventricular function is the important factor affecting the surgical results and it is hard to evaluate the underlying cause before the operation.

    Release date:2016-08-30 06:09 Export PDF Favorites Scan
  • Nontransplantation Surgical Cardiac Remodeling Operation for Endstage Cardiac Valve Disease

    Objective To evaluate the effectiveness and prospect of nontransplantation surgical cardiac remodeling for endstage cardiac valve disease by performing the remodeling operation (including anatomical and functional remodeling) after strict perioperative adjustment for endstage cardiac valve disease. Methods We retrospectively analyzed the clinical data of 31 patients, including 14 males and 17 females, with endstage cardiac valve disease who were treated with surgical cardiac remodeling operation from December 2005 to July 2009 in the 2nd Hospital of Anhui Medical University . Their age ranged from 27 to 74 years with an average age of 40.4 years. Continuous renal replacement therapy (CRRT) was carried out 3 days before surgery in all patients and intraaortic balloon pumping (IABP) was performed 1-3 days before operation in 9 patients. Among the patients, there were 13 patients of mitral valve replacement (MVR), 7 patients of aortic valve replacement (AVR), 4 patients of tricuspid valve replacement (TVR), and 7 patients of double valve replacement (DVR). At the same time, all patients underwent ventricular or atrial volume reduction operation, including 19 patients of left atrial partial excision or plication, 7 patients of partial left ventricular excision, 5 patients of left atrial and left ventricular volume reduction operation, 21 patients of partial right atrial excision, and 3 patients of partial right ventricular excision. Besides, there were 5 patients of De Vega plasty, 14 patients of annuloplasty and3 patients of coronary artery bypass grafting (CABG). The echocardiogram was used to observe the change of heart function, atrium and ventricular in patients on postoperative and follow -up period. Results After surgery, one patient died of low cardiac output syndrome, and one other patient gave -up because of incision and mediastinum infection after reoperation for hemorrhage. Twentynine patients were followed -up for 3 to 12 months with 1 case lost. During the follow- -up, 3 patients died, of whom 2 died of deterioration of heart function and 1 died of sudden stroke. In the 12th month during the follow -up, heart function of all other 25 patients showed obvious improvements with 12 classⅠ, 7 classⅡ, 3 classⅢ and 3 classⅣ heart function according to NYHA classification. At the end of the follow -up, ejection fraction (5400%±800% vs. 2500%±300%) and cardiac index [3.30±0.50 L/(min·m2) vs. 1.10±0.30 L/(min·m2)] were significantly higher than those before operation (P<0.05), whereas left ventricular end diastolic diameter (5200±1000 mm vs. 9500±1200 mm) and left atrial diameter (3900±800 mm vs. 7000±1200 mm) both decreased significantly than those before operation (P<0.05). Conclusion Cardiac remodeling operation for endstage cardiac valve disease after active adjustment and preparation can achieve similar results to operation for severe valve diseases, providing a new choice for endstage heart disease.

    Release date:2016-08-30 05:56 Export PDF Favorites Scan
  • Minimally Invasive and Routine Mitral Valve Repair or Replacement for Patients with Single Mitral Valve Disease:A Case Control Study

    Objective To compare the clinical outcomes and safety of minimally invasive and routine mitral valve repair or replacement for patients with single mitral valve disease. Methods We retrospectively analyzed the clinical data of 67 patients with single mitral valve disease (without aortic valve and tricuspid valve lesion or other heart diseases including atrial septal defect) who underwent mitral valve repair or replacement in the First Affiliated Hospital of China Medical University between January and July 2011. The patients were divided into two groups according to different surgical approaches:the minimally invasive surgery group (n=29,8 males and 21 females,age 51.4±9.4 years) underwent minimally invasive mitral valve repair or replacement via right mini-thoractomy;and the routine surgery group (n=38,11 males and 27 females,age 53.6±11.9 years) underwent mitral valve repair or replacement via middle sternotomy. In the minimally invasive surgery group,9 patients underwent mitral valve repair while the other 20 patients underwent mitral valve replacement. And no patient underwent transition to routine operation. In the routine surgery group,15 patients underwent mitral valve repair and 23 patients underwent mitral valve replacement. Clinical outcomes and safety of the operations were compared between the two groups. Results There was no statistical difference in operation time between the two groups (207.9±18.1 min versus 198.4±27.5 min,P=0.076). The amount of postoperative drainage (126.7±34.5 ml versus 435.6±87.2 ml,P=0.000) and blood transfusion (red blood cell 1.4±0.8 U versus 2.3±1.1 U,P=0.000;blood plasma 164.3±50.4 ml versus 405.6±68.9 ml,P=0.000) of the minimally invasive surgery group were significantly lower than those of the routine surgery group. The cardiopulmonary bypass time (81.7±23.9 min versus 58.7±13.6 min,P=0.000) and aortic-clamping time (51.6±12.7 min versus 38.4±11.7 min,P=0.000) of the minimally invasive surgery group were significantly longer than those of the routine surgery group. The length of ICU stay (22.5±3.6 h versus 31.7±8.5 h,P=0.000),mechanical ventilation (7.4±3.2 h versus 11.2±5.1 h,P=0.000) and postoperative hospitalization (7.1±1.6 d versus 13.5±2.4 d,P=0.000) of the minimally invasive surgery group were significantly shorter than those of the routine surgery group. There was no statistical difference in postoperative complications between the two groups. Minimally invasive surgery group patients were followed up for 5.3±2.4 months with a follow-up rate of 72.4%(21/29). Routine surgery group patients were followed up for 5.5±3.8 months with a follow-up rate of 71.0%(27/38). There was no significant complication during follow-up in both two groups. Conclusion Minimally invasive mitral valve operation via right mini-thoracotomy is effective and safe with a good cosmetic result. Compared with routine operation,patients undergoing minimally invasive operation recover better and faster.

    Release date:2016-08-30 05:46 Export PDF Favorites Scan
  • Surgical Therapy for Valve Diseases Combined with Coronary Heart Diseases in Patients Over or Below 70 Years Old

    Surgical Therapy for Valve Diseases Combined with Coronary Heart Diseases in Patients Over or Below 70 Years Old YU Lei, GU Tianxiang, SHI Enyi, XIU Zongyi, FANG Qin, ZHANG Yuhai. (Department of Cardiac Surgery, The No. 1 Hospital of China Medical University, Shenyang 110001, P.R. China)Corresponding author: GU Tianxiang, Email: cmugtx@sina.comAbstract: Objective To summarize the experiences of valve replacement combined with coronary artery bypass grafting (CABG) in senile patients by comparing clinical outcomes of valve diseases combined with coronary heart diseases in patients over or below 70 years old. Methods We retrospectively analyzed the clinical data of 49 patients who received valve replacement combined with CABG in our department from May 1999 to December 2007. Based on the age, the patients were divided into ≥70 years group (17 cases) with its patients at or above 70 years old and lt;70 years group (32 cases) with its patients younger than 70. The percentage of chronic obstructive pulmonary diseases (COPD) before surgery in ≥70 years group was higher than that in lt;70 years group(Plt;0.05). No significant difference was found in the other relevant factors between the two groups. The clinical index of patients in the two groups were compared and analyzed. Results There were significant differences between the two groups in such factors as the percentage of biovalve use (82.4% vs. 12.5%, χ2=23.311, P=0.000), the time of mechanic ventilation (34.5±29.3 h vs. 18.0±16.1 h, t=-2.542,P=0.014), the time of ICU stay (4.4±1.5 d vs. 3.3±0.7 d, t=-3.522, P=0.001), the time of hospital stay (21.4±7.7 d vs. 18.1±1.8 d, t=-2.319, P=0.025), the percentage of IABP use (29.4% vs. 6.3%, χ2=4.862, P=0.037), the percentage of pulmonary function failure (35.3% vs. 6.3%, χ2=6.859, P=0.009), the percentage of acute renal failure (23.5% vs. 3.1%, χ2=5.051, P=0.025), and the percentage of cerebrovascular accident (11.8% vs. 0.0%, χ2=3.933, P=0.048). There was no significant difference between the two groups in factors like the anastomosis of distal graft (2.5±3.1 vs. 2.4±14, t=0.301, P=0.758), the time of aortic occlusion (89.3±25.4 min vs. 88.5±31.0 min, t=0.108,P=0.913), the time of cardiopulmonary bypass (144.6±44.8 min vs. 138.3±52.9 min, t=0.164, P=0.871) and the mortality (5.9% vs. 6.3%, χ2=0.002,P=0.959). The perioperative myocardial infarction rate was zero in both groups. ≥70 years group patients were followed up for 2 months to 9 years with only 1 case missing. One patient who had undergone mechanic valve replacement died of cerebral hemorrhage 1.5 years after operation. Two died of heart failure and lung cancer 3 months and 6 years after operation respectively. For all the others, the cardiac function was at class Ⅰ to Ⅱ and their life quality was significantly improved. The follow up time of lt;70 years group was 1 month to 6 years and 5 cases were missing. Four patients who had undergone mechanic valve replacement died of complications in relation to anticoagulation treatment. One died of severe low cardiac output. Another died of traffic accident. Conclusion Surgery operation and effective perioperative treatment are key elements in improving surgery successful rate and decreasing mortality in patients with valve and coronary artery diseases. Valve replacement combined with CABG is safe for patients older than 70 years old.

    Release date:2016-08-30 06:02 Export PDF Favorites Scan
  • Intraoperative Saline-irrigated Radiofrequency Modified Maze Procedure for Chronic Atrial Fibrillation in Mitral Valve Diseases

    Objective To report the preliminary results of intraoperative saline-irrigated radiofrequency modified maze procedure for chronic atrial fibrillation (AF) in mitral valve diseases. Methods From May 2003 to April 2004 forty-one patients underwent intraoperative saline-irrigated modified maze procedure. The patients included 13 male and 28 female. Their age ranged from 27-65 years (46±10 years). The duration of AF varied from 5 months to 15 years (4.5±3.6 years).The left atrial diameter varied from 37-93 mm (54±11mm). There were mitral stenosis 20, mitral regurgitation 1 and mitral stenosis with regurgitation 20 cases. Cardiopulmonary bypass (CPB) was established as usual. Ablation lines were made with Cardioblate (Medtronic, 25-30 W, 180-240ml/h). Having finished right-sided maze procedure, the aorta was cross-clamped and cold crystalloid or blood cardioplegia were used for myocardial protection. Left atrial incision was performed through the interatrial groove. The ablation lines were created to encircle the orifices of the left and right pulmonary veins respectively. The ablation lines were also performed from the left encircling line to the posterior mitral valvular annulus and to the orifice of left atrial appendage respectively. A ablation line was used to connect left and right pulmonary veins circumferential line. Concomitant procedures were performed (there were double valve replacement 10 cases, mitral valve replacement 31 cases, tricuspid annuloplasty 6 cases, removing the left atrial thrombi 6 cases). Results CPB time varied from 71-160 min (105±24 min) and cross-clamping time varied from 32-106 min (62±20 min). The ablation time varied from 4-22 min (11±4 min). One patient died during hospitalization and the death was caused by acute mechanic valve obstruction. During follow-up at discharge and 3 months 35% patients (14/40) were free of AF and the others were not. But at 6 months 67% patients (10/15) were free of AF. Conclusion The intraoperative saline-irrigated radiofrequency modified maze procedure is comparatively simpler and its efficacy is satisfactory.

    Release date:2016-08-30 06:25 Export PDF Favorites Scan